140 resultados para RADIATION DOSES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Prior to 2009, one of the problems faced by radiation therapists who supervised and assessed students on placement in Australian clinical centres, was that each of the six Australian universities where Radiation Therapy (RT) programmes were conducted used different clinical assessment and reporting criteria. This paper describes the development of a unified national clinical assessment and reporting form that was implemented nationally by all six universities in 2009. Methods: A four phase methodology was used to develop the new assessment form and user guide. Phase 1 included university consensus around domains of student practice and assessment, and alignment with national competency standards; Phase 2 was a national consensus workshop attended by radiation therapists involved in student supervision and assessment; Phase 3 was an action research re-iterative Delphi technique involving two rounds of a mail-out to gain further expert consensus; and stage 4 was national piloting of the developed assessment form. Results: The new assessment form includes five main domains of practice and 19 sub-domain criteria which students are assessed against during placement. Feedback from the pilot centre participants was positive, with the new form being assessed to be comprehensive and complemented by the accompanying user guide. Conclusion: The new assessment form has improved both the formative and summative assessment of students on placement, as well as enhancing the quality of feedback to students and the universities. The new national form has high acceptance from the Australian universities and has been subject to wide review by the profession.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The aim of this case study is to describe clinical staff perceptions of implementing a person-centred model of nursing in an outpatient radiotherapy treatment department, using a Primary Nursing/Collaborative Practice framework. The questions are: 1) what are the nursing and radiotherapy staff perspectives of the changed model of care, 2) what factors impacted on aspects of the evolving model?, and 3) how was interdisciplinary collaboration influenced by the new model? Methods An instrumental case study addressed the multiple perspectives of several radiotherapy health professionals, within a qualitative approach, to assess the new model of nursing care. Interview data were obtained from thirteen clinical staff over a six month period approximately one year after the model was implemented. Results The new model supports nurses to work more closely with the individual patient, with some perceived positive patient outcomes. Nurses reported increased satisfaction with their work, more autonomy and responsibility, and improved working relationships with medical staff. They also became more aware of the holistic approach to support positive patient outcomes. However, this study acknowledged that education was required for nurses to provide holistic care, especially in the context of complex interdisciplinary relationships. Conclusions A person-centred nursing approach in radiotherapy represents a radical change to the functional approach, providing some benefits for patients. However, the challenges of providing holistic care in the context of complex interdisciplinary relationships are evident, and this study acknowledges the importance of a team approach to addressing changes in practice in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The appropriateness of applying drink driving legislation to motorcycle riding has been questioned as there may be fundamental differences in the effects of alcohol on these two activities. For example, while the distribution of blood alcohol content (BAC) levels among fatally injured male drivers compared to riders is similar, a greater proportion of motorcycle fatalities involve levels in the lower (0 to .10% BAC) range. Several psychomotor and higher-order cognitive skills underpinning riding performance appear to be significantly influenced by low levels of alcohol. For example, at low levels (.02 to .046% BAC), riders show significant increases in reaction time to hazardous stimuli, inattention to the riding task, performance errors such as leaving the roadway and a reduced ability to complete a timed course. It has been suggested that alcohol may redirect riders’ focus from higher-order cognitive skills to more physical skills such as maintaining balance. As part of a research program to investigate the potential benefits of introducing a zero, or reduced, BAC for all riders in Queensland regardless of their licence status, the effects of low doses of alcohol on balance ability were investigated in a laboratory setting. The static balance of ten experienced riders was measured while they performed either no secondary task, a visual search task, or a cognitive (arithmetic) task following the administration of alcohol (0; 0.02, and 0.05% BAC). Subjective ratings of intoxication and balance impairment increased in a dose-dependent manner; however, objective measures of static balance were negatively affected only at the .05% BAC dose. Performance on a concurrent secondary visual search task, but not a purely cognitive (arithmetic) task, improved postural stability across all BAC levels. Finally, the .05% BAC dose was associated with impaired performance on the cognitive (arithmetic) task, but not the visual search task, when participants were balancing, but neither task was impaired by alcohol when participants were standing on the floor. Implications for road safety and future ‘drink riding’ policy considerations are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research developed and scientifically validated a new ultrasound transmission computed tomography system with the aim of quantitative assessment of a polymer gel dosimeter including dose response verification of ultrasonic parameters of attenuation, velocity and broadband ultrasound attenuation (BUA). This work was the first to investigate and report ultrasound frequency dependent attenuation in a gel dosimeter, demonstrating a dose dependence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organ motion as a result of respiration is an important field of research for medical physics. Knowledge of magnitude and direction of this motion is necessary to allow for more accurate radiotherapy treatment planning. This will result in higher doses to the tumour whilst sparing healthy tissue. This project involved human trials, where the radiation therapy patient's kidneys were CT scanned under three different conditions; whilst free breathing (FB), breath-hold at normal tidal inspiration (BHIN), and breath-hold at normal tidal expiration (BHEX). The magnitude of motion was measured by recording the outline of the kidney from a Beam's Eye View (BEV). The centre of mass of this 2D shape was calculated for each set using "ImageJ" software and the magnitude of movement determined from the change in the centroid's coordinates between the BHIN and BHEX scans. The movement ranged from, for the left and right kidneys, 4-46mm and 2-44mm in the superior/inferior (axial) plane, 1-21mm and 2- 16mm in the anterior/posterior (coronal) plane, and 0-6mm and 0-8mm in the lateral/medial (sagittal) plane. From exhale to inhale, the kidneys tended to move inferiorly, anteriorly and laterally. A standard radiotherapy plan, designed to treat the para-aortics with opposed lateral fields was performed on the free breathing (planning) CT set. The field size and arrangement was set up using the same parameters for each subject. The prescription was to deliver 45 Gray in 25 fractions. This field arrangement and prescription was then copied over to the breath hold CT sets, and the dosimetric differences were compared using Dose Volume Histograms (DVH). The point of comparison for the three sets was recorded as the percentage volume of kidney receiving less than or equal to 10 Gray. The QUASAR respiratory motion phantom was used with the range of motion determined from the human study. The phantom was imaged, planned and treated with a linear accelerator with dose determined by film. The effect of the motion was measured by the change in the penumbra of the film and compared to the penumbra from the treatment planning system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Ondansetron is a 5-HT3 receptor antagonist commonly used as an anti-emetic to prevent the nausea and vomiting associated with anti-cancer drugs, cancer radiotherapy, or postoperatively. Recently, the US Food and Drug Administration (FDA) issued a warning for ondansetron due to a potential for prolongation of the QT interval of the electrocardiogram (ECG), a phenomenon that is associated with an increased risk of the potentially fatal arrhythmia torsade de pointes. Areas covered: We undertook a review of the cardiac safety of ondansetron. Our primary sources of information were PubMed (with downloading of full articles), and the internet. Expert opinion: The dose of ondansetron that the FDA has concerns about is 32 mg iv (or several doses that are equivalent to this), which is only used in preventing nausea and vomiting associated with cancer chemotherapy. This suggests that ondansetron may be safe in the lower doses used to prevent the nausea and vomiting in radiation treatment or postoperatively. However, as there is a report that a lower dose of ondansetron prolonged the QT interval in healthy volunteers, this needs to be clarified by the FDA. More research needs to be undertaken of the relationship between QT prolongation and torsades in order that the FDA can produce clear-cut evidence of pro-arrhythmic risk when introducing warnings for this.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The incidences of skin cancers resulting from chronic ultraviolet radiation (UVR) exposure are on the incline both in Australia and globally. Hence, the cellular and molecular pathways associated with UVR-induced photocarcinogenesis urgently need to be elucidated, in order to develop more robust preventative and treatment strategies against skin cancers. In vitro investigations into the effects of UVR (in particular the highly-mutagenic UVB wavelength) have, to date, mainly involved the use of cell culture and animal models. However, these models possess biological disparities to native skin, which to some extent have limited their relevance to the in vivo situation. To address this, we characterised a 3-dimensional, tissue-engineered human skin equivalent (HSE) model (consisting of primary human keratinocytes cultured on a dermal-derived scaffold) as a representation of a more physiologically-relevant platform to study keratinocyte responses to UVB. Significantly, we demonstrate that this model retains several important epidermal properties of native skin. Moreover, UVB-irradiation of the HSE constructs was shown to induce key markers of photodamage in the HSE keratinocytes, including the formation of cyclobutane pyrimidine dimers, the activation of apoptotic pathways, the accumulation of p53 and the secretion of inflammatory cytokines. Importantly, we also demonstrate that the UVB-exposed HSE constructs retain the capacity for epidermal repair and regeneration following photodamage. Together, our results demonstrate the potential of this skin equivalent model as a tool to study various aspects of the acute responses of human keratinocytes to UVB radiation damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Radiation-induced skin reaction (RISR) is a common side effect that affects the majority of cancer patients receiving radiation treatment. RISR is often characterised by swelling,redness, pigmentation, fibrosis, and ulceration, pain, warmth, burning, and itching of the skin. The aim of this systematic review was to assess the effects of interventions which aim to prevent or manage RISR in people with cancer. Methods We searched the following databases up to November 2012: Cochrane Skin Group Specialised Register, CENTRAL (2012, Issue 11), MEDLINE (from 1946), EMBASE (from 1974), PsycINFO (from 1806), CINAHL (from 1981) and LILACS (from 1982). Randomized controlled trials evaluating interventions for preventing or managing RISR in cancer patients were included. The primary outcomes were development of RISR, and levels of RISR and symptom severity. Secondary outcomes were time taken to develop erythema or dry desquamation; quality of life; time taken to heal, a number of skin reaction and symptom severity measures; cost, participant satisfaction; ease of use and adverse effects. Where appropriate, we pooled results of randomized controlled trials using mean differences (MD) or odd ratios (OR) with 95% confidence intervals (CI). Results Forty-seven studies were included in this review. These evaluated six types of interventions (oral systemic medications; skin care practices; steroidal topical therapies; non-steroidal topical therapies; dressings and other). Findings from two meta-analyses demonstrated significant benefits of oral Wobe-Mugos E for preventing RISR (OR 0.13 (95% CI 0.05 to 0.38)) and limiting the maximal level of RISR (MD −0.92 (95% CI −1.36 to −0.48)). Another meta-analysis reported that wearing deodorant does not influence the development of RISR (OR 0.80 (95% CI 0.47 to 1.37)). Conclusions Despite the high number of trials in this area, there is limited good, comparative research that provides definitive results suggesting the effectiveness of any single intervention for reducing RISR. More research is required to demonstrate the usefulness of a wide range of products that are being used for reducing RISR. Future efforts for reducing RISR severity should focus on promising interventions, such as Wobe-Mugos E and oral zinc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In vitro studies indicate that folate in collected human blood is vulnerable to degradation after exposure to ultraviolet (UV) radiation. This has raised concerns about folate depletion in individuals with high sun exposure. Here, we investigate the association between personal solar UV radiation exposure and serum folate concentration, using a three-week prospective study that was undertaken in females aged 18–47 years in Brisbane, Australia (153 E, 27 S). Following two weeks of supplementation with 500 μg of folic acid daily, the change in serum folate status was assessed over a 7-day period of measured personal sun exposure. Compared to participants with personal UV exposures of <200 Joules per day, participants with personal UV exposures of 200–599 and >600 Joules per day had significantly higher depletion of serum folate (p = 0.015). Multivariable analysis revealed personal UV exposure as the strongest predictor accounting for 20% of the overall change in serum folate (Standardised B = −0.49; t = −3.75; p = <0.01). These data show that increasing solar UV radiation exposures reduces the effectiveness of folic acid supplementation. The consequences of this association may be most pronounced for vulnerable individuals, such as women who are pregnant or of childbearing age with high sun exposures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Radiation Therapy students at Queensland University of Technology undertake clinical placement across a wide range of sites Interpersonal skills with clinical staff and patients are an essential component: – Lectures – Role playing – Expert patient input

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Personal ultraviolet dosimeters have been used in epidemiological studies to understand the risks and benefits of individuals' exposure to solar ultraviolet radiation (UVR). We investigated the types and determinants of non-compliance associated with a protocol for use of polysulphone UVR dosimeters. In the AusD Study, 1,002 Australian adults (aged 18-75 years) were asked to wear a new dosimeter on their wrist each day for 10 consecutive days to quantify their daily exposure to solar UVR. Of the 10,020 dosimeters distributed, 296 (3%) were not returned or used (Type I non-compliance) and other usage errors were reported for 763 (8%) returned dosimeters (Type II non-compliance). Type I errors were more common in participants with predominantly outdoor occupations. Type II errors were reported more frequently on the first day of measurement; weekend days or rainy days; and among females; younger people; more educated participants or those with outdoor occupations. Half (50%) the participants reported a non-compliance error on at least one day during the 10-day period. However, 92% of participants had at least 7 days of usable data without any apparent non-compliance issues. The factors identified should be considered when designing future UVR dosimetry studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Quantitative Assessment of Solar UV [ultraviolet] Exposure for Vitamin D Synthesis in Australian Adults (AusD) Study aimed to better define the relationship between sun exposure and serum 25-hydroxyvitamin D (25(OH)D) concentration. Cross-sectional data were collected between May 2009 and December 2010 from 1,002 participants aged 18-75 years in 4 Australian sites spanning 24° of latitude. Participants completed the following: 1) questionnaires on sun exposure, dietary vitamin D intake, and vitamin D supplementation; 2) 10 days of personal ultraviolet radiation dosimetry; 3) a sun exposure and physical activity diary; and 4) clinical measurements and blood collection for 25(OH)D determination. Our multiple regression model described 40% of the variance in 25(OH)D concentration; modifiable behavioral factors contributed 52% of the explained variance, and environmental and demographic or constitutional variables contributed 38% and 10%, respectively. The amount of skin exposed was the single strongest contributor to the explained variance (27%), followed by location (20%), season (17%), personal ultraviolet radiation exposure (8%), vitamin D supplementation (7%), body mass index (weight (kg)/height (m)2) (4%), and physical activity (4%). Modifiable behavioral factors strongly influence serum 25(OH)D concentrations in Australian adults. In addition, latitude was a strong determinant of the relative contribution of different behavioral factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stereotactic radiosurgery treatments involve the delivery of very high doses for a small number of fractions. To date, there is limited data in terms of the skin dose for the very small field sizes used in these treatments. In this work, we determine relative surface doses for small size circular collimators as used in stereotactic radiosurgery treatments. Monte Carlo calculations were performed using the BEAMnrc code with a model of the Novalis 15 Trilogy linear accelerator and the BrainLab circular collimators. The surface doses were calculated at the ICRU skin dose depth of 70 m all using the 6 MV SRS x-ray beam. The calculated surface doses varied between 15 – 12% with decreasing values as the field size increased from 4 to 30 mm. In comparison, surface doses were measured using Gafchromic EBT3 film positioned at the surface of a Virtual Water phantom. The absolute agreement between calculated and measured surface doses was better than 2.5% which is well within the 20 uncertainties of the Monte Carlo calculations and the film measurements. Based on these results, we have shown that the Gafchromic EBT3 film is suitable for surface dose estimates in very small size fields as used in SRS.