151 resultados para Osseointegrated implant


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mechanically well-defined stabilization systems have only recently become available, providing standardized conditions for studying the role of the mechanical environment on mouse bone fracture healing. The aim of this study was to characterize the time course of strength recovery and callus development of mouse femoral osteotomies stabilized with either low or high flexibility (in bending and torsion) internal fixation plates. Animals were euthanized and femora excised at 14, 21, and 28 days post-osteotomy for microCT analysis and torsional strength testing. While a larger mineralized callus was observed in osteotomies under more flexible conditions at all time points, the earlier bridging of the mineralized callus under less flexible conditions by 1 week resulted in an earlier recovery of torsional strength in mice stabilized with low flexibility fixation. Ultimate torque values for these bones were significantly higher at 14 and 21 days post-osteotomy compared to bones with the more flexible stabilization. Our study confirms the high reproducibility of the results that are achieved with this new implant system, therefore making it ideal for studying the influence of the mechanical environment on murine fracture healing under highly standardized conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adolescent idiopathic scoliosis (AIS) is a complex 3D deformity of the spine, which may require surgical correction in severe cases. Computer models of the spine provide a potentially powerful tool to virtually ‘test’ various surgical scenarios prior to surgery. Using patient-specific computer models of seven AIS patients who had undergone a single rod anterior procedure, we have recently found that the majority of the deformity correction occurs at the apical joint or the joint immediately cephalic to the apex. In the current paper, we investigate the biomechanics of the apical joint for these patients using clinically measured intra-operative compressive forces applied during implant placement. The aim of this study is to determine a relationship between the compressive joint force applied intra-operatively and the achievable deformity correction at the apical joint.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Use of patient-specific computer models as a pre-operative planning tool permits predictions of the likely deformity correction and allows a more detailed investigation of the biomechanical influence of different surgical procedures on the scoliotic spinal anatomy. In this paper, patient-specific computer models are used of adolescent idiopathic scoliosis patients who underwent a single rod anterior procedure at the Mater Children’s Hospital in Brisbane, to predict deformity correction and to investigate the change in biomechanics of the scoliotic spine due to surgical compressive forces applied during implant placement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Demineralized freeze-dried bone allografts (DFDBAs) have been proposed as a useful adjunct in periodontal therapy to induce periodontal regeneration through the induction of new bone formation. The presence of bone morphogenetic proteins (BMPs) within the demineralized matrix has been proposed as a possible mechanism through which DFDBA may exert its biologic effect. However, in recent years, the predictability of results using DFDBA has been variable and has led to its use being questioned. One reason for the variability in tissue response may be attributed to differences in the processing of DFDBA, which may lead to loss of activity of any bioactive substances within the DFDBA matrix. Therefore, the purpose of this investigation was to determine whether there are detectable levels of bone morphogenetic proteins in commercial DFDBA preparations. METHODS: A single preparation of DFDBA was obtained from three commercial sources. Each preparation was studied in triplicate. Proteins within the DFDBA samples were first extracted with 4M guanidinium HCI for seven days at 40 degrees celsius and the residue was further extracted with 4M guanidinium HCL/EDTA for seven days at 40 degrees celsius. Two anti-human BMP-2 and -4 antibodies were used for the detection of the presence of BMP's in the extracts. RESULTS: Neither BMP-2 nor BMP-4 was detected in any of the extracts. When recombinant human BMP-2 and -4 were added throughout the extraction process of DFDBA extraction, not only were intact proteins detected but smaller molecular weight fragments were also noted in the extract. CONCLUSIONS: These results indicate that all of the DFDBA samples tested had no detectable amounts of BMP-2 and -4. In addition, an unknown substance present in the DFDBA may be responsible for degradation of whatever BMPs might be present.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This longitudinal analysis examines how patterns of contraceptive use changed over 11 years among Australian women born between 1973 and 1978. Study Design: The analysis included 6708 women sampled from the Australian universal health insurance database who completed four self-report postal surveys between 1996 and 2006. Change over time in use of any method of contraception and the common single methods of the oral contraceptive pill and condom was examined using a longitudinal logistic regression model. Results: The oral contraceptive pill was the most commonly used single method at each survey (27-44%) but decreased over time. Over time, contraceptive users were increasingly more likely to be single or in a de facto relationship or to have had two or more births. Conclusions: Women's contraceptive use and the factors associated with contraceptive use change over time as women move into relationships, try to conceive, have babies and complete their families.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

3D models of long bones are being utilised for a number of fields including orthopaedic implant design. Accurate reconstruction of 3D models is of utmost importance to design accurate implants to allow achieving a good alignment between two bone fragments. Thus for this purpose, CT scanners are employed to acquire accurate bone data exposing an individual to a high amount of ionising radiation. Magnetic resonance imaging (MRI) has been shown to be a potential alternative to computed tomography (CT) for scanning of volunteers for 3D reconstruction of long bones, essentially avoiding the high radiation dose from CT. In MRI imaging of long bones, the artefacts due to random movements of the skeletal system create challenges for researchers as they generate inaccuracies in the 3D models generated by using data sets containing such artefacts. One of the defects that have been observed during an initial study is the lateral shift artefact occurring in the reconstructed 3D models. This artefact is believed to result from volunteers moving the leg during two successive scanning stages (the lower limb has to be scanned in at least five stages due to the limited scanning length of the scanner). As this artefact creates inaccuracies in the implants designed using these models, it needs to be corrected before the application of 3D models to implant design. Therefore, this study aimed to correct the lateral shift artefact using 3D modelling techniques. The femora of five ovine hind limbs were scanned with a 3T MRI scanner using a 3D vibe based protocol. The scanning was conducted in two halves, while maintaining a good overlap between them. A lateral shift was generated by moving the limb several millimetres between two scanning stages. The 3D models were reconstructed using a multi threshold segmentation method. The correction of the artefact was achieved by aligning the two halves using the robust iterative closest point (ICP) algorithm, with the help of the overlapping region between the two. The models with the corrected artefact were compared with the reference model generated by CT scanning of the same sample. The results indicate that the correction of the artefact was achieved with an average deviation of 0.32 ± 0.02 mm between the corrected model and the reference model. In comparison, the model obtained from a single MRI scan generated an average error of 0.25 ± 0.02 mm when compared with the reference model. An average deviation of 0.34 ± 0.04 mm was seen when the models generated after the table was moved were compared to the reference models; thus, the movement of the table is also a contributing factor to the motion artefacts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Owing to the successful use of non-invasive vibration analysis to monitor the progression of dental implant healing and stabilization, it is now being considered as a method to monitor femoral implants in transfemoral amputees. This study uses composite femur-implant physical models to investigate the ability of modal analysis to detect changes at the interface between the implant and bone simulating those that occur during osseointegration. Using electromagnetic shaker excitation, differences were detected in the resonant frequencies and mode shapes of the model when the implant fit in the bone was altered to simulate the two interface cases considered: firm and loose fixation. The study showed that it is beneficial to examine higher resonant frequencies and their mode shapes (rather than the fundamental frequency only) when assessing fixation. The influence of the model boundary conditions on the modal parameters was also demonstrated. Further work is required to more accurately model the mechanical changes occurring at the bone-implant interface in vivo, as well as further refinement of the model boundary conditions to appropriately represent the in vivo conditions. Nevertheless, the ability to detect changes in the model dynamic properties demonstrates the potential of modal analysis in this application and warrants further investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Currently available volar locking plates for the treatment of distal radius fractures incorporate at least two distal screw rows for fixation of the metaphyseal fragment and have a variable-angle locking mechanism which allows placement of the screws in various directions There is, however no evidence that these plates translate into better outcomes or have superior biomechanical properties to first generation plates, which had a single distal screw row and fixed-angle locking. The aim of our biomechanical study was to compare fixed-angle single-row plates with variable-angle multi-row plates to clarify the optimal number of locking screws. MATERIALS AND METHODS: Five different plate-screw combinations of three different manufacturers were tested, each group consisting of five synthetic fourth generation distal radius bones. An AO type C2 fracture was created and the fractures were plated according to each manufacturer's recommendations. The specimens then underwent cyclic and load-to-failure testing. An optical motion analysis system was used to detect displacement of fragments. RESULTS: No significant differences were detected after cyclic loading as well as after load-to-failure testing, neither in regard to axial deformation, implant rigidity or maximum displacement. The fixed-angle single-row plate showed the highest pre-test rigidity, least increase in post-testing rigidity and highest load-to-failure rigidity and least radial shortening. The radial shortening of plates with two distal screw rows was 3.1 and 4.3 times higher, respectively, than that of the fixed-angle single-row plate. CONCLUSION: The results of our study indicate that two distal screw rows do not add to construct rigidity and resistance against loss of reduction. Well conducted clinical studies based on the findings of biomechanical studies are necessary to determine the optimal number of screws necessary to achieve reproducibly good results in the treatment of distal radius fractures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Articular cartilage defects are common after joint injuries. When left untreated, the biomechanical protective function of cartilage is gradually lost, making the joint more susceptible to further damage, causing progressive loss of joint function and eventually osteoarthritis (OA). In the process of translating promising tissue-engineering cartilage repair approaches from bench to bedside, pre-clinical animal models including mice, rabbits, goats, and horses, are widely used. The equine species is becoming an increasingly popular model for the in vivo evaluation of regenerative orthopaedic approaches. As there is also an increasing body of evidence suggesting that successful lasting tissue reconstruction requires an implant that mimics natural tissue organization, it is imperative that depth-dependent characteristics of equine osteochondral tissue are known, to assess to what extent they resemble those in humans. Therefore, osteochondral cores (4-8 mm) were obtained from the medial and lateral femoral condyles of equine and human donors. Cores were processed for histology and for biochemical quantification of DNA, glycosaminoglycan (GAG) and collagen content. Equine and human osteochondral tissues possess similar geometrical (thickness) and organizational (GAG, collagen and DNA distribution with depth) features. These comparable trends further underscore the validity of the equine model for the evaluation of regenerative approaches for articular cartilage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chapter 3: Use of contraception. p15-32 Key findings: This section examines trends in the use of contraception between 1996 and 2006 by women who participated in the surveys for the 1973-1978 cohort of the Australian Longitudinal Study on Women’s Health. 1. The oral contraceptive pill was the most commonly used method of contraception at each survey, but its use decreased over time. 2.Of women who consistently used contraception, 40% used the oral contraceptive pill as their only method of contraception in at least three out of four surveys. 3. The proportion of women using condoms as their only method of contraception remained steady over time (15-18%) but only 3% of all women used condoms only at every survey. 4. The proportion of women using both condoms and the oral contraceptive pill remained steady at 13-14% of all women from Survey 1 to 3, but decreased to 8% of all women at Survey 4. 5. The use of methods other than the oral contraceptive pill and/or condoms increased at Survey 4. 6. The proportion of women using an implant (e.g. Implanon) remained steady between Surveys 3 and 4, with 3% of women using an implant only. Around one third of implant users at Survey 3 continued to use this method at Survey 4. 7. The main reasons for not using contraception at Surveys 3 and 4 were pregnancy, trying to conceive, or no male sexual partners. 8. Women who used contraception were more likely to be in de facto relationships or single, be up to date with Pap tests and have had two or more births. 9. Women who did not use contraception were more likely to be non-drinkers and/or do low levels of exercise, have had one birth and have experienced miscarriage. 10. Contraception changed in expected ways according to reproductive events: women who reported only miscarriages between surveys also stopped using contraception in the same period; most women who did not report reproductive events continued to use the same method of contraception; and women who had a termination tended to switch methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Several new types of contraception became available in Australia over the last twelve years (the implant in 2001, progestogen intra-uterine device (IUD) in 2003, and vaginal contraceptive ring in 2007). Most methods of contraception require access to health services. Permanent sterilisation and the insertion of an implant or IUD involve a surgical procedure. Access to health professionals providing these specialised services may be more difficult in rural areas. This paper examines uptake of permanent or long-acting reversible contraception (LARCs) among Australian women in rural areas compared to women in urban areas. Method: Participants in the Australian Longitudinal Study on Women's Health born in 1973-78 reported on their contraceptive use at three surveys: 2003, 2006 and 2009. Contraceptive methods included permanent sterilisation (tubal ligation, vasectomy), non-daily or LARC methods (implant, IUD, injection, vaginal ring), and other methods including daily, barrier or "natural" methods (oral contraceptive pills, condoms, withdrawal, safe period). Sociodemographic, reproductive history and health service use factors associated with using permanent, LARC or other methods were examined using a multivariable logistic regression analysis. Results: Of 9,081 women aged 25-30 in 2003, 3% used permanent methods and 4% used LARCs. Six years later in 2009, of 8,200 women (aged 31-36), 11% used permanent methods and 9% used LARCs. The fully adjusted parsimonious regression model showed that the likelihood of a woman using LARCs and permanent methods increased with number of children. Women whose youngest child was school-age were more likely to use LARCs (OR=1.83, 95%CI 1.43-2.33) or permanent methods (OR=4.39, 95%CI 3.54-5.46) compared to women with pre-school children. Compared to women living in major cities, women in inner regional areas were more likely to use LARCs (OR=1.26, 95%CI 1.03-1.55) or permanent methods (OR=1.43, 95%CI 1.17-1.76). Women living in outer regional and remote areas were more likely than women living in cities to use LARCs (OR=1.65, 95%CI 1.31-2.08) or permanent methods (OR=1.69, 95%CI 1.43-2.14). Women with poorer access to GPs were more likely to use permanent methods (OR=1.27, 95%CI 1.07-1.52). Conclusions: Location of residence and access to health services are important factors in women's choices about long-acting contraception in addition to the number and age of their children. There is a low level of uptake of non-daily, long-acting methods of contraception among Australian women in their mid-thirties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. We develop a sheep thoracic spine interbody fusion model to study the suitability of polycaprolactone-based scaffold and recombinant human bone morphogenetic protein-2 (rhBMP-2) as a bone graft substitute within the thoracic spine. The surgical approach is a mini- open thoracotomy with relevance to minimally invasive deformity correction surgery for adolescent idiopathic scoliosis. To date there are no studies examining the use of this biodegradable implant in combination with biologics in a sheep thoracic spine model. Methods. In the present study, six sheep underwent a 3-level (T6/7, T8/9 and T10/11) discectomy with randomly allocated implantation of a different graft substitute at each of the three levels; (i) calcium phosphate (CaP) coated polycaprolactone based scaffold plus 0.54µg rhBMP-2, (ii) CaP coated PCL- based scaffold alone or (iii) autograft (mulched rib head). Fusion was assessed at six months post-surgery. Results. Computed Tomographic scanning demonstrated higher fusion grades in the rhBMP-2 plus PCL- based scaffold group in comparison to either PCL-based scaffold alone or autograft. These results were supported by histological evaluations of the respective groups. Biomechanical testing revealed significantly higher stiffness for the rhBMP-2 plus PCL- based scaffold group in all loading directions in comparison to the other two groups. Conclusions. The results of this study demonstrate that rhBMP-2 plus PCL-based scaffold is a viable bone graft substitute, providing an optimal environment for thoracic interbody spinal fusion in a large animal model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There has been much discussion and controversy in the media recently regarding metal toxicity following large head metal on metal (MoM) total hip replacement (THR). Patients have been reported as having hugely elevated levels of metal ions with, at times, devastating systemic, neurolgical and/or orthopaedic sequelae. However, no direct correlation between metal ion level and severity of metallosis has yet been defined. Normative levels of metal ions in well functioning, non Cobalt-Chrome hips have also not been defined to date. The Exeter total hip replacement contains no Cobalt-Chrome (Co-Cr) as it is made entirely from stainless steel. However, small levels of these metals may be present in the modular head of the prosthesis, and their effect on metal ion levels in the well functioning patient has not been investigated. We proposed to define the “normal” levels of metal ions detected by blood test in 20 well functioning patients at a minimum 1 year post primary Exeter total hip replacement, where the patient had had only one joint replaced. Presently, accepted normal levels of blood Chromium are 10–100 nmol/L and plasma Cobalt are 0–20 nmol/L. The UK Modern Humanities Research Association (MHRA) has suggested that levels of either Cobalt or Chromium above 7 ppb (equivalent to 135 nmol/L for Chromium and 120 nmol/L for Cobalt) may be significant. Below this level it is indicated that significant soft tissue reaction and tissue damage is less likely and the risk of implant failure is reduced. Hips were a mixture of cemented and hybrid procedures performed by two experienced orthopaedic consultants. Seventy percent were female, with a mixture of head sizes used. In our cohort, there were no cases where the blood Chromium levels were above the normal range, and in more than 70% of cases, levels were below recordable levels. There were also no cases of elevated plasma Cobalt levels, and in 35% of cases, levels were negligible. We conclude that the implantation with an Exeter total hip replacement does not lead to elevation of blood metal ion levels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The giant freshwater prawn (Macrobrachium rosenbergii) or GFP is one of the most important freshwater crustacean species in the inland aquaculture sector of many tropical and subtropical countries. Since the 1990’s, there has been rapid global expansion of freshwater prawn farming, especially in Asian countries, with an average annual rate of increase of 48% between 1999 and 2001 (New, 2005). In Vietnam, GFP is cultured in a variety of culture systems, typically in integrated or rotational rice-prawn culture (Phuong et al., 2006) and has become one of the most common farmed aquatic species in the country, due to its ability to grow rapidly and to attract high market price and high demand. Despite potential for expanded production, sustainability of freshwater prawn farming in the region is currently threatened by low production efficiency and vulnerability of farmed stocks to disease. Commercial large scale and small scale GFP farms in Vietnam have experienced relatively low stock productivity, large size and weight variation, a low proportion of edible meat (large head to body ratio), scarcity of good quality seed stock. The current situation highlights the need for a systematic stock improvement program for GFP in Vietnam aimed at improving economically important traits in this species. This study reports on the breeding program for fast growth employing combined (between and within) family selection in giant freshwater prawn in Vietnam. The base population was synthesized using a complete diallel cross including 9 crosses from two local stocks (DN and MK strains) and a third exotic stock (Malaysian strain - MY). In the next three selection generations, matings were conducted between genetically unrelated brood stock to produce full-sib and (paternal) half-sib families. All families were produced and reared separately until juveniles in each family were tagged as a batch using visible implant elastomer (VIE) at a body size of approximately 2 g. After tags were verified, 60 to 120 juveniles chosen randomly from each family were released into two common earthen ponds of 3,500 m2 pond for a grow-out period of 16 to 18 weeks. Selection applied at harvest on body weight was a combined (between and within) family selection approach. 81, 89, 96 and 114 families were produced for the Selection line in the F0, F1, F2 and F3 generations, respectively. In addition to the Selection line, 17 to 42 families were produced for the Control group in each generation. Results reported here are based on a data set consisting of 18,387 body and 1,730 carcass records, as well as full pedigree information collected over four generations. Variance and covariance components were estimated by restricted maximum likelihood fitting a multi-trait animal model. Experiments assessed performance of VIE tags in juvenile GFP of different size classes and individuals tagged with different numbers of tags showed that juvenile GFP at 2 g were of suitable size for VIE tags with no negative effects evident on growth or survival. Tag retention rates were above 97.8% and tag readability rates were 100% with a correct assignment rate of 95% through to mature animal size of up to 170 g. Across generations, estimates of heritability for body traits (body weight, body length, cephalothorax length, abdominal length, cephalothorax width and abdominal width) and carcass weight traits (abdominal weight, skeleton-off weight and telson-off weight) were moderate and ranged from 0.14 to 0.19 and 0.17 to 0.21, respectively. Body trait heritabilities estimated for females were significantly higher than for males whereas carcass weight trait heritabilities estimated for females and males were not significantly different (P > 0.05). Maternal and common environmental effects for body traits accounted for 4 to 5% of the total variance and were greater in females (7 to 10%) than in males (4 to 5%). Genetic correlations among body traits were generally high in both sexes. Genetic correlations between body and carcass weight traits were also high in the mixed sexes. Average selection response (% per generation) for body weight (transformed to square root) estimated as the difference between the Selection and the Control group was 7.4% calculated from least squares means (LSMs), 7.0% from estimated breeding values (EBVs) and 4.4% calculated from EBVs between two consecutive generations. Favourable correlated selection responses (estimated from LSMs) were detected for other body traits (12.1%, 14.5%, 10.4%, 15.5% and 13.3% for body length, cephalothorax length, abdominal length, cephalothorax width and abdominal width, respectively) over three selection generations. Data in the second selection generation showed positive correlated responses for carcass weight traits (8.8%, 8.6% and 8.8% for abdominal weight, skeleton-off weight and telson-off weight, respectively). Data in the third selection generation showed that heritability for body traits were moderate and ranged from 0.06 to 0.11 and 0.11 to 0.22 at weeks 10 and 18, respectively. Body trait heritabilities estimated at week 10 were not significantly lower than at week 18. Genetic correlations between body traits within age and genetic correlations for body traits between ages were generally high. Overall our results suggest that growth rate responds well to the application of family selection and carcass weight traits can also be improved in parallel, using this approach. Moreover, selection for high growth rate in GFP can be undertaken successfully before full market size has been reached. The outcome of this study was production of an improved culture strain of GFP for the Vietnamese culture industry that will be trialed in real farm production environments to confirm the genetic gains identified in the experimental stock improvement program.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The treatment for deep surgical site infection (SSI) following primary total hip arthroplasty (THA) varies internationally and it is at present unclear which treatment approaches are used in Australia. The aim of this study is to identify current treatment approaches in Queensland, Australia, show success rates and quantify the costs of different treatments. METHODS: Data for patients undergoing primary THA and treatment for infection between January 2006 and December 2009 in Queensland hospitals were extracted from routinely used hospital databases. Records were linked with pathology information to confirm positive organisms. Diagnosis and treatment of infection was determined using ICD-10-AM and ACHI codes, respectively. Treatment costs were estimated based on AR-DRG cost accounting codes assigned to each patient hospital episode. RESULTS: A total of n=114 patients with deep surgical site infection were identified. The majority of patients (74%) were first treated with debridement, antibiotics and implant retention (DAIR), which was successful in eradicating the infection in 60.3% of patients with an average cost of $13,187. The remaining first treatments were 1-stage revision, successful in 89.7% with average costs of $27,006, and 2-stage revisions, successful in 92.9% of cases with average costs of $42,772. Multiple treatments following 'failed DAIR' cost on average $29,560, for failed 1-stage revision were $24,357, for failed 2-stage revision were $70,381 and were $23,805 for excision arthroplasty. CONCLUSIONS: As treatment costs in Australia are high primary prevention is important and the economics of competing treatment choices should be carefully considered. These currently vary greatly across international settings.