80 resultados para Occupancy
Resumo:
Sheona Thomson writes about the transformation of a public institution in relation to a study on post-occupancy. "Brisbanites like me, with memories of long hours of study in the former buildings of the State Library of Queensland, can only marvel at the living institution we have in our city today. For most of the 80s, our bookish pursuits were hosted in the fustily intimate reading rooms of Centennial Hall, the late 1950s extension to the nineteenth-century building (formerly housing the state museum) by F. D. G. Stanley in William Street on the north bank of the Brisbane River. At the time, the wheels of an expansive cultural ambition were turning, and piece by piece on the south bank of the river the rambling Queensland Cultural Centre was realized. The fourth stage of the complex opened in 1988 as the new home for the State Library and for many years after, countless studious, transient folk whiled away time in the deep interiors of the straight-faced concrete and glass edifice by Robin Gibson and Partners..."
Resumo:
This paper develops theory that quantifies transit route passenger-relative load factor and distinguishes it from occupancy load factor. The ratio between these measures is defined as the load diversity coefficient, which as a single measure characterizes the diversity of passenger load factor between route segments according to the origin-destination profile. The relationship between load diversity coefficient and route coefficient of variation in occupancy load factor is quantified. Two tables are provided that enhance passenger capacity and quality of service (QoS) assessment regarding onboard passenger load. The first expresses the transit operator’s perspective of load diversity and the passengers’ perspective of load factor relative to the operator’s, across six service levels corresponding to ranges of coefficient of variation in occupancy load factor. The second interprets the relationships between passenger average travel time and each of passenger-relative load factor and occupancy load factor. The application of this methodology is illustrated using a case study of a premium radial bus route in Brisbane, Australia. The methodology can assist in benchmarking and decision making regarding route and schedule design. Future research will apply value of time to QoS measurement, reflecting perceived passenger comfort through crowding and average time spent aboard. This would also assist in transit service quality econometric modeling.
Resumo:
This poster introduces Passenger Relative Load Factor for a route or individual bus service as a capacity and quality of service measure, distinguishing it from Occupancy Load Factor. It introduces Load Diversity Coefficient as the ratio of Passenger Relative Load Factor to Occupancy Load Factor, and relates Load Diversity Coefficient to Coefficient of Variation in Occupancy Load Factor. It qualifies the operator’s and passengers’ perspectives of load factor based on Coefficient of Variation in Occupancy Load Factor along a route. A case study using weekday Automatic Fare Collection (AFC) data on a premium bus line in Brisbane, Australia illustrates the methodology. The compendium paper also qualifies the operator’s and passengers’ perspectives of these load factors along with Passengers’ Average Travel Time for capacity and quality of service assessment.
Resumo:
In many parts of the world, uncontrolled fires in sparsely populated areas are a major concern as they can quickly grow into large and destructive conflagrations in short time spans. Detecting these fires has traditionally been a job for trained humans on the ground, or in the air. In many cases, these manned solutions are simply not able to survey the amount of area necessary to maintain sufficient vigilance and coverage. This paper investigates the use of unmanned aerial systems (UAS) for automated wildfire detection. The proposed system uses low-cost, consumer-grade electronics and sensors combined with various airframes to create a system suitable for automatic detection of wildfires. The system employs automatic image processing techniques to analyze captured images and autonomously detect fire-related features such as fire lines, burnt regions, and flammable material. This image recognition algorithm is designed to cope with environmental occlusions such as shadows, smoke and obstructions. Once the fire is identified and classified, it is used to initialize a spatial/temporal fire simulation. This simulation is based on occupancy maps whose fidelity can be varied to include stochastic elements, various types of vegetation, weather conditions, and unique terrain. The simulations can be used to predict the effects of optimized firefighting methods to prevent the future propagation of the fires and greatly reduce time to detection of wildfires, thereby greatly minimizing the ensuing damage. This paper also documents experimental flight tests using a SenseFly Swinglet UAS conducted in Brisbane, Australia as well as modifications for custom UAS.
Resumo:
Cool roof coatings have a beneficial impact on reducing the heat load of a range of building types, resulting in reduced cooling energy loads. This study seeks to understand the extent to which cool roof coatings could be used as a residential demand side management (DSM) strategy for retrofitting existing housing in a constrained network area in tropical Australia where peak electrical demand is heavily influenced by residential cooling loads. In particular this study seeks to determine whether simulation software used for building regulation purposes can provide networks with the ‘impact certainty’ required by their DSM principles. The building simulation method is supported by a field experiment. Both numerical and experimental data confirm reductions in total consumption (kWh) and energy demand (kW). The nature of the regulated simulation software, combined with the diverse nature of residential buildings and their patterns of occupancy, however, mean that simulated results cannot be extrapolated to quantify benefits to a broader distribution network. The study suggests that building data gained from regulatory simulations could be a useful guide for potential impacts of widespread application of cool roof coatings in this region. The practical realization of these positive impacts, however, would require changes to the current business model for the evaluation of DSM strategies. The study provides seven key recommendations that encourage distribution networks to think beyond their infrastructure boundaries, recognising that the broader energy system also includes buildings, appliances and people.