83 resultados para Lecture capture
Resumo:
Interstitial fibrosis, a histological process common to many kidney diseases, is the precursor state to end stage kidney disease, a devastating and costly outcome for the patient and the health system. Fibrosis is historically associated with chronic kidney disease (CKD) but emerging evidence is now linking many forms of acute kidney disease (AKD) with the development of CKD. Indeed, we and others have observed at least some degree of fibrosis in up to 50% of clinically defined cases of AKD. Epithelial cells of the proximal tubule (PTEC) are central in the development of kidney interstitial fibrosis. We combine the novel techniques of laser capture microdissection and multiplex-tandem PCR to identify and quantitate “real time” gene transcription profiles of purified PTEC isolated from human kidney biopsies that describe signaling pathways associated with this pathological fibrotic process. Our results: (i) confirm previous in-vitro and animal model studies; kidney injury molecule-1 is up-regulated in patients with acute tubular injury, inflammation, neutrophil infiltration and a range of chronic disease diagnoses, (ii) provide data to inform treatment; complement component 3 expression correlates with inflammation and acute tubular injury, (iii) identify potential new biomarkers; proline 4-hydroxylase transcription is down-regulated and vimentin is up-regulated across kidney diseases, (iv) describe previously unrecognized feedback mechanisms within PTEC; Smad-3 is down-regulated in many kidney diseases suggesting a possible negative feedback loop for TGF-β in the disease state, whilst tight junction protein-1 is up-regulated in many kidney diseases, suggesting feedback interactions with vimentin expression. These data demonstrate that the combined techniques of laser capture microdissection and multiplex-tandem PCR have the power to study molecular signaling within single cell populations derived from clinically sourced tissue.
Resumo:
Animal models of critical illness are vital in biomedical research. They provide possibilities for the investigation of pathophysiological processes that may not otherwise be possible in humans. In order to be clinically applicable, the model should simulate the critical care situation realistically, including anaesthesia, monitoring, sampling, utilising appropriate personnel skill mix, and therapeutic interventions. There are limited data documenting the constitution of ideal technologically advanced large animal critical care practices and all the processes of the animal model. In this paper, we describe the procedure of animal preparation, anaesthesia induction and maintenance, physiologic monitoring, data capture, point-of-care technology, and animal aftercare that has been successfully used to study several novel ovine models of critical illness. The relevant investigations are on respiratory failure due to smoke inhalation, transfusion related acute lung injury, endotoxin-induced proteogenomic alterations, haemorrhagic shock, septic shock, brain death, cerebral microcirculation, and artificial heart studies. We have demonstrated the functionality of monitoring practices during anaesthesia required to provide a platform for undertaking systematic investigations in complex ovine models of critical illness.
Resumo:
Traditional comparisons between the capture efficiency of sampling devices have generally looked at the absolute differences between devices. We recommend that the signal-to-noise ratio be used when comparing the capture efficiency of benthic sampling devices. Using the signal-to-noise ratio rather than the absolute difference has the advantages that the variance is taken into account when determining how important the difference is, the hypothesis and minimum detectable difference can be made identical for all taxa, it is independent of the units used for measurement, and the sample-size calculation is independent of the variance. This new technique is illustrated by comparing the capture efficiency of a 0.05 m(2) van Veen grab and an airlift suction device, using samples taken from Heron and One Tree lagoons, Australia.
Resumo:
Security models for two-party authenticated key exchange (AKE) protocols have developed over time to capture the security of AKE protocols even when the adversary learns certain secret values. Increased granularity of security can be modelled by considering partial leakage of secrets in the manner of models for leakage-resilient cryptography, designed to capture side-channel attacks. In this work, we use the strongest known partial-leakage-based security model for key exchange protocols, namely continuous after-the-fact leakage eCK (CAFL-eCK) model. We resolve an open problem by constructing the first concrete two-pass leakage-resilient key exchange protocol that is secure in the CAFL-eCK model.
Resumo:
On 30 March 2015 the Australian Federal Government launched its "Re-Think" initiative with the objective of achieving a better tax system which delivers taxes that are lower, simpler and fairer. The discussion paper released as part of the "Re:think" initiative is designed to start a national conversation on tax reform. However, inquiries into Australia's future tax system, subsequent reforms and the introduction of new taxes are nothing new. Unfortunately, recent history also demonstrates that reform initiatives arising from reviews of the Australian tax system are often deemed a failure. The most prominent of these failures in recent times is the Minerals Resource Rent Tax (MRRT), which lasted a mere 16 months before its announced repeal. Using the established theoretic framework of regulatory capture to interpret publically observable data, the purpose of this article is to explain the failure of this arguably sound tax. It concludes that the MRRT legislation itself, through the capture by the mining companies, provided internal subsidization in the form of reduced tax and minimal or no rents. In doing so, it offers an opportunity to understand and learn from past experiences to ensure that recommendations coming out of the Re:think initiative do not suffer the same fate.
Resumo:
Introduction Markerless motion capture systems are relatively new devices that can significantly speed up capturing full body motion. A precision of the assessment of the finger’s position with this type of equipment was evaluated at 17.30 ± 9.56 mm when compare to an active marker system [1]. The Microsoft Kinect was proposed to standardized and enhanced clinical evaluation of patients with hemiplegic cerebral palsy [2]. Markerless motion capture systems have the potential to be used in a clinical setting for movement analysis, as well as for large cohort research. However, the precision of such system needs to be characterized. Global objectives • To assess the precision within the recording field of the markerless motion capture system Openstage 2 (Organic Motion, NY). • To compare the markerless motion capture system with an optoelectric motion capture system with active markers. Specific objectives • To assess the noise of a static body at 13 different location within the recording field of the markerless motion capture system. • To assess the smallest oscillation detected by the markerless motion capture system. • To assess the difference between both systems regarding the body joint angle measurement. Methods Equipment • OpenStage® 2 (Organic Motion, NY) o Markerless motion capture system o 16 video cameras (acquisition rate : 60Hz) o Recording zone : 4m * 5m * 2.4m (depth * width * height) o Provide position and angle of 23 different body segments • VisualeyezTM VZ4000 (PhoeniX Technologies Incorporated, BC) o Optoelectric motion capture system with active markers o 4 trackers system (total of 12 cameras) o Accuracy : 0.5~0.7mm Protocol & Analysis • Static noise: o Motion recording of an humanoid mannequin was done in 13 different locations o RMSE was calculated for each segment in each location • Smallest oscillation detected: o Small oscillations were induced to the humanoid mannequin and motion was recorded until it stopped. o Correlation between the displacement of the head recorded by both systems was measured. A corresponding magnitude was also measured. • Body joints angle: o Body motion was recorded simultaneously with both systems (left side only). o 6 participants (3 females; 32.7 ± 9.4 years old) • Tasks: Walk, Squat, Shoulder flexion & abduction, Elbow flexion, Wrist extension, Pronation / supination (not in results), Head flexion & rotation (not in results), Leg rotation (not in results), Trunk rotation (not in results) o Several body joint angles were measured with both systems. o RMSE was calculated between signals of both systems. Results Conclusion Results show that the Organic Motion markerless system has the potential to be used for assessment of clinical motor symptoms or motor performances However, the following points should be considered: • Precision of the Openstage system varied within the recording field. • Precision is not constant between limb segments. • The error seems to be higher close to the range of motion extremities.
Resumo:
To evaluate the underreporting rate of death -cause data in Shandong province during 2012 to 2013 by capture -mark -recapture method and to provide the base for health strategy. Methods All counties were divided into 5 stratifications according the death rates of 2012, and 14 counties were selected, then 3 towns or streets were selected in each country, 10 villages or neighborhood committees were selected in each town (street). The death data collected from security bureau and civil affairs bureau were compared with the reporting death data from the National Cause of Death Surveillance, and the underreporting rate was calculated. Results In present study, 6 929 death cases were collected, it was found that 1 556 cases were underreported. The death cases estimated by CMR method were 6 227 cases (95%CI: 7 593-7 651), and the average underreporting rate was 23.15%. There were significantly differences between different stratifications (P<0.01). The underreporting rate in 0-4 years old group was 56.93%, the male underreporting rate was 22.31% and the female underreporting rate was 24.09%. There was no significant difference between male and female groups (P>0.05). Conclusion There is an obvious underreport in the cause of death surveillance of Shandong province, and the underreporting rates are different among the 5 stratifications. The underreporting rate is higher in 0-4 years old group, and the investigation of the death cause surveillance for young residents is not perfect in some countries. The investigation quality of the death cause surveillance should be improved, increasing the integrity of the report data and adjusting the mortalities in different stratifications for obtaining a accurate mortality in Shandong province.
Resumo:
Network data packet capture and replay capabilities are basic requirements for forensic analysis of faults and security-related anomalies, as well as for testing and development. Cyber-physical networks, in which data packets are used to monitor and control physical devices, must operate within strict timing constraints, in order to match the hardware devices' characteristics. Standard network monitoring tools are unsuitable for such systems because they cannot guarantee to capture all data packets, may introduce their own traffic into the network, and cannot reliably reproduce the original timing of data packets. Here we present a high-speed network forensics tool specifically designed for capturing and replaying data traffic in Supervisory Control and Data Acquisition systems. Unlike general-purpose "packet capture" tools it does not affect the observed network's data traffic and guarantees that the original packet ordering is preserved. Most importantly, it allows replay of network traffic precisely matching its original timing. The tool was implemented by developing novel user interface and back-end software for a special-purpose network interface card. Experimental results show a clear improvement in data capture and replay capabilities over standard network monitoring methods and general-purpose forensics solutions.