127 resultados para LESS-THAN -5.0
Resumo:
Isofraxidin is one of the main bioactive constituents in the root of Acanthopanax senticosus, which has antifatigue, antistress, and immuno-accommondating effects. In this study, an ultraperformance LC (UPLC)-ESI MS method was developed for analyzing isofraxidin and its metabolites in rat plasma. The analysis was performed on a UPLC coupled with ESI MS (quadropole MS tandem TOF MS). The lower LOD (LLOD) for isofraxidin was 0.25 ng/mL, the intraday precision was less than 10%, the interday precision was less than 10%, and the extraction recovery was more than 80%. Isofraxidin and two metabolites (M1 and M2) were detected in rat plasma after oral administration of isofraxidin, and the molecular polarities of M1 and M2 were both increased compared to isofraxidin. The metabolites were identified as 5,6-dihydroxyl-7-methoxycoumarin and 5-hydroxyl-6,7-dimethoxycoumarin when subjected to parent ion spectra, product ion spectra, and extract mass and element composition analyses.
Resumo:
Traditionally, infectious diseases and under-nutrition have been considered major health problems in Sri Lanka with little attention paid to obesity and associated non-communicable diseases (NCDs). However, the recent Sri Lanka Diabetes and Cardiovascular Study (SLDCS) reported the epidemic level of obesity, diabetes and metabolic syndrome. Moreover, obesity-associated NCDs is the leading cause of death in Sri Lanka and there is an exponential increase in hospitalization due to NCDs adversely affecting the development of the country. Despite Sri Lanka having a very high prevalence of NCDs and associated mortality, little is known about the causative factors for this burden. It is widely believed that the global NCD epidemic is associated with recent lifestyle changes, especially dietary factors. In the absence of sufficient data on dietary habits in Sri Lanka, successful interventions to manage these serious health issues would not be possible. In view of the current situation the dietary survey was undertaken to assess the intakes of energy, macro-nutrients and selected other nutrients with respect to socio demographic characteristics and the nutritional status of Sri Lankan adults especially focusing on obesity. Another aim of this study was to develop and validate a culturally specific food frequency questionnaire (FFQ) to assess dietary risk factors of NCDs in Sri Lankan adults. Data were collected from a subset of the national SLDCS using a multi-stage, stratified, random sampling procedure (n=500). However, data collection in the SLDCS was affected by the prevailing civil war which resulted in no data being collected from Northern and Eastern provinces. To obtain a nationally representative sample, additional subjects (n=100) were later recruited from the two provinces using similar selection criteria. Ethical Approval for this study was obtained from the Ethical Review Committee, Faculty of Medicine, University of Colombo, Sri Lanka and informed consent was obtained from the subjects before data were collected. Dietary data were obtained using the 24-h Dietary Recall (24HDR) method. Subjects were asked to recall all foods and beverages, consumed over the previous 24-hour period. Respondents were probed for the types of foods and food preparation methods. For the FFQ validation study, a 7-day weight diet record (7-d WDR) was used as the reference method. All foods recorded in the 24 HDR were converted into grams and then intake of energy and nutrients were analysed using NutriSurvey 2007 (EBISpro, Germany) which was modified for Sri Lankan food recipes. Socio-demographic details and body weight perception were collected from interviewer-administrated questionnaire. BMI was calculated and overweight (BMI ≥23 kg.m-2), obesity (BMI ≥25 kg.m-2) and abdominal obesity (Men: WC ≥ 90 cm; Women: WC ≥ 80 cm) were categorized according to Asia-pacific anthropometric cut-offs. The SPSS v. 16 for Windows and Minitab v10 were used for statistical analysis purposes. From a total of 600 eligible subjects, 491 (81.8%) participated of whom 34.5% (n=169) were males. Subjects were well distributed among different socio-economic parameters. A total of 312 different food items were recorded and nutritionists grouped similar food items which resulted in a total of 178 items. After performing step-wise multiple regression, 93 foods explained 90% of the variance for total energy intake, carbohydrates, protein, total fat and dietary fibre. Finally, 90 food items and 12 photographs were selected. Seventy-seven subjects completed (response rate = 65%) the FFQ and 7-day WDR. Estimated mean energy intake (SD) from FFQ (1794±398 kcal) and 7DWR (1698±333 kcal, P<0.001) was significantly different due to a significant overestimation of carbohydrate (~10 g/d, P<0.001) and to some extent fat (~5 g/d, NS). Significant positive correlations were found between the FFQ and 7DWR for energy (r = 0.39), carbohydrate (r = 0.47), protein (r = 0.26), fat (r =0.17) and dietary fiber (r = 0.32). Bland-Altman graphs indicated fairly good agreement between methods with no relationship between bias and average intake of each nutrient examined. The findings from the nutrition survey showed on average, Sri Lankan adults consumed over 14 portions of starch/d; moreover, males consumed 5 more portions of cereal than females. Sri Lankan adults consumed on average 3.56 portions of added sugars/d. Moreover, mean daily intake of fruit (0.43) and vegetable (1.73) portions was well below minimum dietary recommendations (fruits 2 portions/d; vegetables 3 portions/d). The total fruit and vegetable intake was 2.16 portions/d. Daily consumption of meat or alternatives was 1.75 portions and the sum of meat and pulses was 2.78 portions/d. Starchy foods were consumed by all participants and over 88% met the minimum daily recommendations. Importantly, nearly 70% of adults exceeded the maximum daily recommendation for starch (11portions/d) and a considerable proportion consumed larger numbers of starch servings daily, particularly men. More than 12% of men consumed over 25 starch servings/d. In contrast to their starch consumption, participants reported very low intakes of other food groups. Only 11.6%, 2.1% and 3.5% of adults consumed the minimum daily recommended servings of vegetables, fruits, and fruits and vegetables combined, respectively. Six out of ten adult Sri Lankans sampled did not consume any fruits. Milk and dairy consumption was extremely low; over a third of the population did not consume any dairy products and less than 1% of adults consumed 2 portions of dairy/d. A quarter of Sri Lankans did not report consumption of meat and pulses. Regarding protein consumption, 36.2% attained the minimum Sri Lankan recommendation for protein; and significantly more men than women achieved the recommendation of ≥3 servings of meat or alternatives daily (men 42.6%, women 32.8%; P<0.05). Over 70% of energy was derived from carbohydrates (Male:72.8±6.4%, Female:73.9±6.7%), followed by fat (Male:19.9±6.1%, Female:18.5±5.7%) and proteins (Male:10.6±2.1%, Female:10.9±5.6%). The average intake of dietary fiber was 21.3 g/day and 16.3 g/day for males and females, respectively. There was a significant difference in nutritional intake related to ethnicities, areas of residence, education levels and BMI categories. Similarly, dietary diversity was significantly associated with several socio-economic parameters among Sri Lankan adults. Adults with BMI ≥25 kg.m-2 and abdominally obese Sri Lankan adults had the highest diet diversity values. Age-adjusted prevalence (95% confidence interval) of overweight, obesity, and abdominal obesity among Sri Lankan adults were 17.1% (13.8-20.7), 28.8% (24.8-33.1), and 30.8% (26.8-35.2), respectively. Men, compared with women, were less overweight, 14.2% (9.4-20.5) versus 18.5% (14.4-23.3), P = 0.03, less obese, 21.0% (14.9-27.7) versus 32.7% (27.6-38.2), P < .05; and less abdominally obese, 11.9% (7.4-17.8) versus 40.6% (35.1-46.2), P < .05. Although, prevalence of obesity has reached to epidemic level body weight misperception was common among Sri Lankan adults. Two-thirds of overweight males and 44.7% of females considered themselves as in "about right weight". Over one third of both male and female obese subjects perceived themselves as "about right weight" or "underweight". Nearly 32% of centrally obese men and women perceived that their waist circumference is about right. People who perceived overweight or very overweight (n = 154) only 63.6% tried to lose their body weight (n = 98), and quarter of adults seek advices from professionals (n = 39). A number of important conclusions can be drawn from this research project. Firstly, the newly developed FFQ is an acceptable tool for assessing the nutrient intake of Sri Lankans and will assist proper categorization of individuals by dietary exposure. Secondly, a substantial proportion of the Sri Lankan population does not consume a varied and balanced diet, which is suggestive of a close association between the nutrition-related NCDs in the country and unhealthy eating habits. Moreover, dietary diversity is positively associated with several socio-demographic characteristics and obesity among Sri Lankan adults. Lastly, although obesity is a major health issue among Sri Lankan adults, body weight misperception was common among underweight, healthy weight, overweight, and obese adults in Sri Lanka. Over 2/3 of overweight and 1/3 of obese Sri Lankan adults believe that they are in "right weight" or "under-weight" categories.
Resumo:
Background Commercially available instrumented treadmill systems that provide continuous measures of temporospatial gait parameters have recently become available for clinical gait analysis. This study evaluated the level of agreement between temporospatial gait parameters derived from a new instrumented treadmill, which incorporated a capacitance-based pressure array, with those measured by a conventional instrumented walkway (criterion standard). Methods Temporospatial gait parameters were estimated from 39 healthy adults while walking over an instrumented walkway (GAITRite®) and instrumented treadmill system (Zebris) at matched speed. Differences in temporospatial parameters derived from the two systems were evaluated using repeated measures ANOVA models. Pearson-product-moment correlations were used to investigate relationships between variables measured by each system. Agreement was assessed by calculating the bias and 95% limits of agreement. Results All temporospatial parameters measured via the instrumented walkway were significantly different from those obtained from the instrumented treadmill (P < .01). Temporospatial parameters derived from the two systems were highly correlated (r, 0.79–0.95). The 95% limits of agreement for temporal parameters were typically less than ±2% of gait cycle duration. However, 95% limits of agreement for spatial measures were as much as ±5 cm. Conclusions Differences in temporospatial parameters between systems were small but statistically significant and of similar magnitude to changes reported between shod and unshod gait in healthy young adults. Temporospatial parameters derived from an instrumented treadmill, therefore, are not representative of those obtained from an instrumented walkway and should not be interpreted with reference to literature on overground walking.
Resumo:
Aim: To explore weight status perception and its relation to actual weight status in a contemporary cohort of 5- to 17-year-old children and adolescents. Methods: Body mass index (BMI), derived from height and weight measurements, and perception of weight status (‘too thin’, ‘about right’ and ‘too fat’) were evaluated in 3043 participants from the Healthy Kids Queensland Survey. In children less than 12 years of age, weight status perception was obtained from the parents, whereas the adolescents self-reported their perceived weight status. Results: Compared with measured weight status by established BMI cut-offs, just over 20% of parents underestimated their child's weight status and only 1% overestimated. Adolescent boys were more likely to underestimate their weight status compared with girls (26.4% vs. 10.2%, P < 0.05) whereas adolescent girls were more likely to overestimate than underestimate (11.8% vs. 3.4%, P < 0.05). Underestimation was greater by parents of overweight children compared with those of obese children, but still less than 50% of parents identified their obese child as ‘too fat’. There was greater recognition of overweight status in the adolescents, with 83% of those who were obese reporting they were ‘too fat’. Conclusion: Whilst there was a high degree of accuracy of weight status perception in those of healthy weight, there was considerable underestimation of weight status, particularly by parents of children who were overweight or obese. Strategies are required that enable parents to identify what a healthy weight looks like and help them understand when intervention is needed to prevent further weight gain as the child gets older.
Resumo:
Purpose: Changes in pupil size and shape are relevant for peripheral imagery by affecting aberrations and how much light enters and/or exits the eye. The purpose of this study is to model the pattern of pupil shape across the complete horizontal visual field and to show how the pattern is influenced by refractive error. Methods: Right eyes of thirty participants were dilated with 1% cyclopentolate and images were captured using a modified COAS-HD aberrometer alignment camera along the horizontal visual field to ±90°. A two lens relay system enabled fixation at targets mounted on the wall 3m from the eye. Participants placed their heads on a rotatable chin rest and eye rotations were kept to less than 30°. Best-fit elliptical dimensions of pupils were determined. Ratios of minimum to maximum axis diameters were plotted against visual field angle. Results: Participants’ data were well fitted by cosine functions, with maxima at (–)1° to (–)9° in the temporal visual field and widths 9% to 15% greater than predicted by the cosine of the field angle . Mean functions were 0.99cos[( + 5.3)/1.121], R2 0.99 for the whole group and 0.99cos[( + 6.2)/1.126], R2 0.99 for the 13 emmetropes. The function peak became less temporal, and the width became smaller, with increase in myopia. Conclusion: Off-axis pupil shape changes are well described by a cosine function which is both decentered by a few degrees and flatter by about 12% than the cosine of the viewing angle, with minor influences of refraction.
Resumo:
Cancer-associated proteases promote peritoneal dissemination and chemoresistance in malignant progression. In this study, kallikrein-related peptidases 4, 5, 6, and 7 (KLK4-7)-cotransfected OV-MZ-6 ovarian cancer cells were embedded in a bioengineered three-dimensional (3D) microenvironment that contains RGD motifs for integrin engagement to analyze their spheroid growth and survival after chemotreatment. KLK4-7-cotransfected cells formed larger spheroids and proliferated more than controls in 3D, particularly within RGD-functionalized matrices, which was reduced upon integrin inhibition. In contrast, KLK4-7-expressing cell monolayers proliferated less than controls, emphasizing the relevance of the 3D microenvironment and integrin engagement. In a spheroid-based animal model, KLK4-7-overexpression induced tumor growth after 4 weeks and intraperitoneal spread after 8 weeks. Upon paclitaxel administration, KLK4-7-expressing tumors declined in size by 91% (controls: 87%) and showed 90% less metastatic outgrowth (controls: 33%, P<0.001). KLK4-7-expressing spheroids showed 53% survival upon paclitaxel treatment (controls: 51%), accompanied by enhanced chemoresistance-related factors, and their survival was further reduced by combination treatment of paclitaxel with KLK4/5/7 (22%, P=0.007) or MAPK (6%, P=0.006) inhibition. The concomitant presence of KLK4-7 in ovarian cancer cells together with integrin activation drives spheroid formation and proliferation. Combinatorial approaches of paclitaxel and KLK/MAPK inhibition may be more efficient for late-stage disease than chemotherapeutics alone as these inhibitory regimens reduced cancer spheroid growth to a greater extent than paclitaxel alone.
Resumo:
We wished to determine whether changing our centre's practice of using Acticoat instead of Silvazine as our first-line burns dressing provided a better standard of care in terms of efficacy, cost and ease of use. A retrospective cohort study was performed examining 328 Silvazine treated patients from January 2000 to June 2001 and 241 Acticoat treated patients from July 2002 to July 2003. During those periods the respective dressings were used exclusively. There was no significant difference in age, %BSA and mechanism of burn between the groups. In the Silvazine group, 25.6% of children required grafting compared to 15.4% in the Acticoat group (p=0.001). When patients requiring grafting were excluded, the time taken for re-epithelialisation in the Acticoat group (14.9 days) was significantly less than that for the Silvazine group (18.3 days), p=0.047. There were more wounds requiring long term scar management in the Silvazine group (32.6%) compared to the Acticoat group (29.5%), however this was not significant. There was only one positive blood culture in each group, indicating that both Silvazine and Acticoat are potent antimicrobial agents. The use of Acticoat as our primary burns dressing has dramatically changed our clinical practice. Inpatients are now only 18% of the total admissions, with the vast majority of patients treated on an outpatient basis. In terms of cost, Acticoat was demonstrated to be less expensive over the treatment period than Silvazine . We have concluded that Acticoat is a safe, cost-effective, efficacious dressing that reduces the time for re-epithelialisation and the requirement for grafting and long term scar management, compared to Silvazine.
Resumo:
Purpose The goal of this work was to set out a methodology for measuring and reporting small field relative output and to assess the application of published correction factors across a population of linear accelerators. Methods and materials Measurements were made at 6 MV on five Varian iX accelerators using two PTW T60017 unshielded diodes. Relative output readings and profile measurements were made for nominal square field sizes of side 0.5 to 1.0 cm. The actual in-plane (A) and cross-plane (B) field widths were taken to be the FWHM at the 50% isodose level. An effective field size, defined as FSeff=A·B, was calculated and is presented as a field size metric. FSeffFSeff was used to linearly interpolate between published Monte Carlo (MC) calculated kQclin,Qmsrfclin,fmsr values to correct for the diode over-response in small fields. Results The relative output data reported as a function of the nominal field size were different across the accelerator population by up to nearly 10%. However, using the effective field size for reporting showed that the actual output ratios were consistent across the accelerator population to within the experimental uncertainty of ±1.0%. Correcting the measured relative output using kQclin,Qmsrfclin,fmsr at both the nominal and effective field sizes produce output factors that were not identical but differ by much less than the reported experimental and/or MC statistical uncertainties. Conclusions In general, the proposed methodology removes much of the ambiguity in reporting and interpreting small field dosimetric quantities and facilitates a clear dosimetric comparison across a population of linacs
Resumo:
Whole-body cryotherapy (WBC) involves short exposures to air temperatures below –100°C. WBC is increasingly accessible to athletes, and is purported to enhance recovery after exercise and facilitate rehabilitation postinjury. Our objective was to review the efficacy and effectiveness of WBC using empirical evidence from controlled trials. We found ten relevant reports; the majority were based on small numbers of active athletes aged less than 35 years. Although WBC produces a large temperature gradient for tissue cooling, the relatively poor thermal conductivity of air prevents significant subcutaneous and core body cooling. There is weak evidence from controlled studies that WBC enhances antioxidant capacity and parasympathetic reactivation, and alters inflammatory pathways relevant to sports recovery. A series of small randomized studies found WBC offers improvements in subjective recovery and muscle soreness following metabolic or mechanical overload, but little benefit towards functional recovery. There is evidence from one study only that WBC may assist rehabilitation for adhesive capsulitis of the shoulder. There were no adverse events associated with WBC; however, studies did not seem to undertake active surveillance of predefined adverse events. Until further research is available, athletes should remain cognizant that less expensive modes of cryotherapy, such as local ice-pack application or cold-water immersion, offer comparable physiological and clinical effects to WBC.
Resumo:
Dynamic light scattering (DLS) has become a primary nanoparticle characterization technique with applications from materials characterization to biological and environmental detection. With the expansion in DLS use from homogeneous spheres to more complicated nanostructures, comes a decrease in accuracy. Much research has been performed to develop different diffusion models that account for the vastly different structures but little attention has been given to the effect on the light scattering properties in relation to DLS. In this work, small (core size < 5 nm) core-shell nanoparticles were used as a case study to measure the capping thickness of a layer of dodecanethiol (DDT) on Au and ZnO nanoparticles by DLS. We find that the DDT shell has very little effect on the scattering properties of the inorganic core and hence can be ignored to a first approximation. However, this results in conventional DLS analysis overestimating the hydrodynamic size in the volume and number weighted distributions. By introducing a simple correction formula that more accurately yields hydrodynamic size distributions a more precise determination of the molecular shell thickness is obtained. With this correction, the measured thickness of the DDT shell was found to be 7.3 ± 0.3 Å, much less than the extended chain length of 16 Å. This organic layer thickness suggests that on small nanoparticles, the DDT monolayer adopts a compact disordered structure rather than an open ordered structure on both ZnO and Au nanoparticle surfaces. These observations are in agreement with published molecular dynamics results.
Resumo:
Activation of β2-adrenergic receptors inhibits osteoblastic bone formation and enhances osteoclastic bone resorption. Whether β-blockers inhibit ovariectomy-induced bone loss and decrease fracture risk remains controversial. To further explore the role of β-adrenergic signaling in skeletal acquisition and response to estrogen deficiency, we evaluated mice lacking the three known β-adrenergic receptors (β-less). Body weight, percent fat, and bone mineral density were significantly higher in male β-less than wild-type (WT) mice, more so with increasing age. Consistent with their greater fat mass, serum leptin was significantly higher in β-less than WT mice. Mid-femoral cross-sectional area and cortical thickness were significantly higher in adult β-less than WT mice, as were femoral biomechanical properties (+28 to +49%, P < 0.01). Young male β-less had higher vertebral (1.3-fold) and distal femoral (3.5-fold) trabecular bone volume than WT (P < 0.001 for both) and lower osteoclast surface. With aging, these differences lessened, with histological evidence of increased osteoclast surface and decreased bone formation rate at the distal femur in β-less vs. WT mice. Serum tartrate-resistance alkaline phosphatase-5B was elevated in β-less compared with WT mice from 8–16 wk of age (P < 0.01). Ovariectomy inhibited bone mass gain and decreased trabecular bone volume/total volume similarly in β-less and WT mice. Altogether, these data indicate that absence of β-adrenergic signaling results in obesity and increased cortical bone mass in males but does not prevent deleterious effects of estrogen deficiency on trabecular bone microarchitecture. Our findings also suggest direct positive effects of weight and/or leptin on bone turnover and cortical bone structure, independent of adrenergic signaling.
Resumo:
Recent developments in chemical pretreatments of lignocellulosic biomass using polyols as co-solvents (e.g., glycerol and ethylene glycol) at temperatures less than 100 °C may allow the effective use of thermostable and non-thermostable cellulases in situ during the saccharification process. The potential of biomass saccharifying enzymes, endoglucanases (EG) from a thermophilic bacterium (Thermotoga maritima) and a mesophilic fungus (Trichoderma longibrachiatum), to retain their activity in aqueous buffer, acidified glycerol, and acidified ethylene glycol used as co-solvents at pretreatment temperatures at or below 100 °C were examined. The results show that despite its origin, T. longibrachiatum EG (Tl-EG) retained 75% of its activity after exposure to 100 °C for 5 min in aqueous buffer while T. maritima EG (Tm-EG) retained only 5% activity. However, at 90 °C both enzymes retained over 87% of their activity. In acidified (0.1% (w/w) H2SO4) glycerol, Tl-EG retained similar activity (80%) to that obtained in glycerol alone, while Tm-EG retained only 35%. With acidified ethylene glycol under these conditions, both Tl-EG and Tm-EG retained 36% of their activity. The results therefore show that Tl-EG is more stable in both acidified glycerol and ethylene glycol than Tm-EG. A preliminary kinetic study showed that pure glycerol improved the thermal stability of Tl-EG but destabilized Tm-EG, relative to the buffer solution. The half-lives of both Tl-EG and Tm-EG are 4.5 min in acidified glycerol, indicating that the effectiveness of these enzymes under typical pretreatment times of greater than 15 min will be considerably diminished. Attempts have been made to explain the differences in the results obtained between the two enzymes.
Resumo:
Introduction The consistency of measuring small field output factors is greatly increased by reporting the measured dosimetric field size of each factor, as opposed to simply stating the nominal field size [1] and therefore requires the measurement of cross-axis profiles in a water tank. However, this makes output factor measurements time consuming. This project establishes at which field size the accuracy of output factors are not affected by the use of potentially inaccurate nominal field sizes, which we believe establishes a practical working definition of a ‘small’ field. The physical components of the radiation beam that contribute to the rapid change in output factor at small field sizes are examined in detail. The physical interaction that dominates the cause of the rapid dose reduction is quantified, and leads to the establishment of a theoretical definition of a ‘small’ field. Methods Current recommendations suggest that radiation collimation systems and isocentre defining lasers should both be calibrated to permit a maximum positioning uncertainty of 1 mm [2]. The proposed practical definition for small field sizes is as follows: if the output factor changes by ±1.0 % given a change in either field size or detector position of up to ±1 mm then the field should be considered small. Monte Carlo modelling was used to simulate output factors of a 6 MV photon beam for square fields with side lengths from 4.0 to 20.0 mm in 1.0 mm increments. The dose was scored to a 0.5 mm wide and 2.0 mm deep cylindrical volume of water within a cubic water phantom, at a depth of 5 cm and SSD of 95 cm. The maximum difference due to a collimator error of ±1 mm was found by comparing the output factors of adjacent field sizes. The output factor simulations were repeated 1 mm off-axis to quantify the effect of detector misalignment. Further simulations separated the total output factor into collimator scatter factor and phantom scatter factor. The collimator scatter factor was further separated into primary source occlusion effects and ‘traditional’ effects (a combination of flattening filter and jaw scatter etc.). The phantom scatter was separated in photon scatter and electronic disequilibrium. Each of these factors was plotted as a function of field size in order to quantify how each affected the change in small field size. Results The use of our practical definition resulted in field sizes of 15 mm or less being characterised as ‘small’. The change in field size had a greater effect than that of detector misalignment. For field sizes of 12 mm or less, electronic disequilibrium was found to cause the largest change in dose to the central axis (d = 5 cm). Source occlusion also caused a large change in output factor for field sizes less than 8 mm. Discussion and conclusions The measurement of cross-axis profiles are only required for output factor measurements for field sizes of 15 mm or less (for a 6 MV beam on Varian iX linear accelerator). This is expected to be dependent on linear accelerator spot size and photon energy. While some electronic disequilibrium was shown to occur at field sizes as large as 30 mm (the ‘traditional’ definition of small field [3]), it has been shown that it does not cause a greater change than photon scatter until a field size of 12 mm, at which point it becomes by far the most dominant effect.
Resumo:
Introduction Total scatter factor (or output factor) in megavoltage photon dosimetry is a measure of relative dose relating a certain field size to a reference field size. The use of solid phantoms has been well established for output factor measurements, however to date these phantoms have not been tested with small fields. In this work, we evaluate the water equivalency of a number of solid phantoms for small field output factor measurements using the EGSnrc Monte Carlo code. Methods The following small square field sizes were simulated using BEAMnrc: 5, 6, 7, 8, 10 and 30 mm. Each simulated phantom geometry was created in DOSXYZnrc and consisted of a silicon diode (of length and width 1.5 mm and depth 0.5 mm) submersed in the phantom at a depth of 5 g/cm2. The source-to-detector distance was 100 cm for all simulations. The dose was scored in a single voxel at the location of the diode. Interaction probabilities and radiation transport parameters for each material were created using custom PEGS4 files. Results A comparison of the resultant output factors in the solid phantoms, compared to the same factors in a water phantom are shown in Fig. 1. The statistical uncertainty in each point was less than or equal to 0.4 %. The results in Fig. 1 show that the density of the phantoms affected the output factor results, with higher density materials (such as PMMA) resulting in higher output factors. Additionally, it was also calculated that scaling the depth for equivalent path length had negligible effect on the output factor results at these field sizes. Discussion and conclusions Electron stopping power and photon mass energy absorption change minimally with small field size [1]. Also, it can be seen from Fig. 1 that the difference from water decreases with increasing field size. Therefore, the most likely cause for the observed discrepancies in output factors is differing electron disequilibrium as a function of phantom density. When measuring small field output factors in a solid phantom, it is important that the density is very close to that of water.
Resumo:
Introduction Given the known challenges of obtaining accurate measurements of small radiation fields, and the increasing use of small field segments in IMRT beams, this study examined the possible effects of referencing inaccurate field output factors in the planning of IMRT treatments. Methods This study used the Brainlab iPlan treatment planning system to devise IMRT treatment plans for delivery using the Brainlab m3 microMLC (Brainlab, Feldkirchen, Germany). Four pairs of sample IMRT treatments were planned using volumes, beams and prescriptions that were based on a set of test plans described in AAPM TG 119’s recommendations for the commissioning of IMRT treatment planning systems [1]: • C1, a set of three 4 cm volumes with different prescription doses, was modified to reduce the size of the PTV to 2 cm across and to include an OAR dose constraint for one of the other volumes. • C2, a prostate treatment, was planned as described by the TG 119 report [1]. • C3, a head-and-neck treatment with a PTV larger than 10 cm across, was excluded from the study. • C4, an 8 cm long C-shaped PTV surrounding a cylindrical OAR, was planned as described in the TG 119 report [1] and then replanned with the length of the PTV reduced to 4 cm. Both plans in each pair used the same beam angles, collimator angles, dose reference points, prescriptions and constraints. However, one of each pair of plans had its beam modulation optimisation and dose calculation completed with reference to existing iPlan beam data and the other had its beam modulation optimisation and dose calculation completed with reference to revised beam data. The beam data revisions consisted of increasing the field output factor for a 0.6 9 0.6 cm2 field by 17 % and increasing the field output factor for a 1.2 9 1.2 cm2 field by 3 %. Results The use of different beam data resulted in different optimisation results with different microMLC apertures and segment weightings between the two plans for each treatment, which led to large differences (up to 30 % with an average of 5 %) between reference point doses in each pair of plans. These point dose differences are more indicative of the modulation of the plans than of any clinically relevant changes to the overall PTV or OAR doses. By contrast, the maximum, minimum and mean doses to the PTVs and OARs were smaller (less than 1 %, for all beams in three out of four pairs of treatment plans) but are more clinically important. Of the four test cases, only the shortened (4 cm) version of TG 119’s C4 plan showed substantial differences between the overall doses calculated in the volumes of interest using the different sets of beam data and thereby suggested that treatment doses could be affected by changes to small field output factors. An analysis of the complexity of this pair of plans, using Crowe et al.’s TADA code [2], indicated that iPlan’s optimiser had produced IMRT segments comprised of larger numbers of small microMLC leaf separations than in the other three test cases. Conclusion: The use of altered small field output factors can result in substantially altered doses when large numbers of small leaf apertures are used to modulate the beams, even when treating relatively large volumes.