86 resultados para Immunization, Passive
Resumo:
Technology is not always introduced into educational contexts in ways that position pedagogy to the fore. In optimizing learning, forward looking approaches require that we question what it means to be an educated person in the 21st Century and how individuals should engage with technologies to be suitably equipped for emergent knowledge age work. Responses to such ideas typically emphasize collaborative knowledge building where technology is employed as a tool to think with and allows for the active messing with and the development of ideas, rather than merely being a passive window to information. This paper discusses a very deliberate attempt to address a range of imperatives and competing demands within a high school setting where wireless handheld technologies integrated with a learning management system (Moodle) are used to scaffold and implement knowledge sharing and knowledge-building within the school community.
Resumo:
AC motors are largely used in a wide range of modern systems, from household appliances to automated industry applications such as: ventilations systems, fans, pumps, conveyors and machine tool drives. Inverters are widely used in industrial and commercial applications due to the growing need for speed control in ASD systems. Fast switching transients and the common mode voltage, in interaction with parasitic capacitive couplings, may cause many unwanted problems in the ASD applications. These include shaft voltage and leakage currents. One of the inherent characteristics of Pulse Width Modulation (PWM) techniques is the generation of the common mode voltage, which is defined as the voltage between the electrical neutral of the inverter output and the ground. Shaft voltage can cause bearing currents when it exceeds the amount of breakdown voltage level of the thin lubricant film between the inner and outer rings of the bearing. This phenomenon is the main reason for early bearing failures. A rapid development in power switches technology has lead to a drastic decrement of switching rise and fall times. Because there is considerable capacitance between the stator windings and the frame, there can be a significant capacitive current (ground current escaping to earth through stray capacitors inside a motor) if the common mode voltage has high frequency components. This current leads to noises and Electromagnetic Interferences (EMI) issues in motor drive systems. These problems have been dealt with using a variety of methods which have been reported in the literature. However, cost and maintenance issues have prevented these methods from being widely accepted. Extra cost or rating of the inverter switches is usually the price to pay for such approaches. Thus, the determination of cost-effective techniques for shaft and common mode voltage reduction in ASD systems, with the focus on the first step of the design process, is the targeted scope of this thesis. An introduction to this research – including a description of the research problem, the literature review and an account of the research progress linking the research papers – is presented in Chapter 1. Electrical power generation from renewable energy sources, such as wind energy systems, has become a crucial issue because of environmental problems and a predicted future shortage of traditional energy sources. Thus, Chapter 2 focuses on the shaft voltage analysis of stator-fed induction generators (IG) and Doubly Fed Induction Generators DFIGs in wind turbine applications. This shaft voltage analysis includes: topologies, high frequency modelling, calculation and mitigation techniques. A back-to-back AC-DC-AC converter is investigated in terms of shaft voltage generation in a DFIG. Different topologies of LC filter placement are analysed in an effort to eliminate the shaft voltage. Different capacitive couplings exist in the motor/generator structure and any change in design parameters affects the capacitive couplings. Thus, an appropriate design for AC motors should lead to the smallest possible shaft voltage. Calculation of the shaft voltage based on different capacitive couplings, and an investigation of the effects of different design parameters are discussed in Chapter 3. This is achieved through 2-D and 3-D finite element simulation and experimental analysis. End-winding parameters of the motor are also effective factors in the calculation of the shaft voltage and have not been taken into account in previous reported studies. Calculation of the end-winding capacitances is rather complex because of the diversity of end winding shapes and the complexity of their geometry. A comprehensive analysis of these capacitances has been carried out with 3-D finite element simulations and experimental studies to determine their effective design parameters. These are documented in Chapter 4. Results of this analysis show that, by choosing appropriate design parameters, it is possible to decrease the shaft voltage and resultant bearing current in the primary stage of generator/motor design without using any additional active and passive filter-based techniques. The common mode voltage is defined by a switching pattern and, by using the appropriate pattern; the common mode voltage level can be controlled. Therefore, any PWM pattern which eliminates or minimizes the common mode voltage will be an effective shaft voltage reduction technique. Thus, common mode voltage reduction of a three-phase AC motor supplied with a single-phase diode rectifier is the focus of Chapter 5. The proposed strategy is mainly based on proper utilization of the zero vectors. Multilevel inverters are also used in ASD systems which have more voltage levels and switching states, and can provide more possibilities to reduce common mode voltage. A description of common mode voltage of multilevel inverters is investigated in Chapter 6. Chapter 7 investigates the elimination techniques of the shaft voltage in a DFIG based on the methods presented in the literature by the use of simulation results. However, it could be shown that every solution to reduce the shaft voltage in DFIG systems has its own characteristics, and these have to be taken into account in determining the most effective strategy. Calculation of the capacitive coupling and electric fields between the outer and inner races and the balls at different motor speeds in symmetrical and asymmetrical shaft and balls positions is discussed in Chapter 8. The analysis is carried out using finite element simulations to determine the conditions which will increase the probability of high rates of bearing failure due to current discharges through the balls and races.
Resumo:
The human knee acts as a sophisticated shock absorber during landing movements. The ability of the knee to perform this function in the real world is remarkable given that the context of the landing movement may vary widely between performances. For this reason, humans must be capable of rapidly adjusting the mechanical properties of the knee under impact load in order to satisfy many competing demands. However, the processes involved in regulating these properties in response to changing constraints remain poorly understood. In particular, the effects of muscle fatigue on knee function during step landing are yet to be fully explored. Fatigue of the knee muscles is significant for 2 reasons. First, it is thought to have detrimental effects on the ability of the knee to act as a shock absorber and is considered a risk factor for knee injury. Second, fatigue of knee muscles provides a unique opportunity to examine the mechanisms by which healthy individuals alter knee function. A review of the literature revealed that the effect of fatigue on knee function during landing has been assessed by comparing pre and postfatigue measurements, with fatigue induced by a voluntary exercise protocol. The information is limited by inconsistent results with key measures, such as knee stiffness, showing varying results following fatigue, including increased stiffness, decreased stiffness or failure to detect any change in some experiments. Further consideration of the literature questions the validity of the models used to induce and measure fatigue, as well as the pre-post study design, which may explain the lack of consensus in the results. These limitations cast doubt on the usefulness of the available information and identify a need to investigate alternative approaches. Based on the results of this review, the aims of this thesis were to: • evaluate the methodological procedures used in validation of a fatigue model • investigate the adaptation and regulation of post-impact knee mechanics during repeated step landings • use this new information to test the effects of fatigue on knee function during a step-landing task. To address the aims of the thesis, 3 related experiments were conducted that collected kinetic, kinematic and electromyographic data from 3 separate samples of healthy male participants. The methodologies involved optoelectronic motion capture (VICON), isokinetic dynamometry (System3 Pro, BIODEX) and wireless surface electromyography (Zerowire, Aurion, Italy). Fatigue indicators and knee function measures used in each experiment were derived from the data. Study 1 compared the validity and reliability of repetitive stepping and isokinetic contractions with respect to fatigue of the quadriceps and hamstrings. Fifteen participants performed 50 repetitions of each exercise twice in randomised order, over 4 sessions. Sessions were separated by a minimum of 1 week’s rest, to ensure full recovery. Validity and reliability depended on a complex interaction between the exercise protocol, the fatigue indicator, the individual and the muscle of interest. Nevertheless, differences between exercise protocols indicated that stepping was less effective in eliciting valid and reliable changes in peak power and spectral compression, compared with isokinetic exercise. A key finding was that fatigue progressed in a biphasic pattern during both exercises. The point separating the 2 phases, known as the transition point, demonstrated superior between-test reliability during the isokinetic protocol, compared with stepping. However, a correction factor should be used to accurately apply this technique to the study of fatigue during landing. Study 2 examined alterations in knee function during repeated landings, with a different sample (N =12) performing 60 consecutive step landing trials. Each landing trial was separated by 1-minute rest periods. The results provided new information in relation to the pre-post study design in the context of detecting adjustments in knee function during landing. First, participants significantly increased or decreased pre-impact muscle activity or post-impact mechanics despite environmental and task constraints remaining unchanged. This is the 1st study to demonstrate this effect in healthy individuals without external feedback on performance. Second, single-subject analysis was more effective in detecting alterations in knee function compared to group-level analysis. Finally, repeated landing trials did not reduce inter-trial variability of knee function in some participants, contrary to assumptions underpinning previous studies. The results of studies 1 and 2 were used to modify the design of Study 3 relative to previous research. These alterations included a modified isokinetic fatigue protocol, multiple pre-fatigue measurements and singlesubject analysis to detect fatigue-related changes in knee function. The study design incorporated new analytical approaches to investigate fatiguerelated alterations in knee function during landing. Participants (N = 16) were measured during multiple pre-fatigue baseline trial blocks prior to the fatigue model. A final block of landing trials was recorded once the participant met the operational fatigue definition that was identified in Study 1. The analysis revealed that the effects of fatigue in this context are heavily dependent on the compensatory response of the individual. A continuum of responses was observed within the sample for each knee function measure. Overall, preimpact preparation and post-impact mechanics of the knee were altered with highly individualised patterns. Moreover, participants used a range of active or passive pre-impact strategies to adapt post-impact mechanics in response to quadriceps fatigue. The unique patterns identified in the data represented an optimisation of knee function based on priorities of the individual. The findings of these studies explain the lack of consensus within the literature regarding the effects of fatigue on knee function during landing. First, functional fatigue protocols lack validity in inducing fatigue-related changes in mechanical output and spectral compression of surface electromyography (sEMG) signals, compared with isokinetic exercise. Second, fatigue-related changes in knee function during landing are confounded by inter-individual variation, which limits the sensitivity of group-level analysis. By addressing these limitations, the 3rd study demonstrated the efficacies of new experimental and analytical approaches to observe fatigue-related alterations in knee function during landing. Consequently, this thesis provides new perspectives into the effects of fatigue in knee function during landing. In conclusion: • The effects of fatigue on knee function during landing depend on the response of the individual, with considerable variation present between study participants, despite similar physical characteristics. • In healthy males, adaptation of pre-impact muscle activity and postimpact knee mechanics is unique to the individual and reflects their own optimisation of demands such as energy expenditure, joint stability, sensory information and loading of knee structures. • The results of these studies should guide future exploration of adaptations in knee function to fatigue. However, research in this area should continue with reduced emphasis on the directional response of the population and a greater focus on individual adaptations of knee function.
Resumo:
In this paper, two different high bandwidth converter control strategies are discussed. One of the strategies is for voltage control and the other is for current control. The converter, in each of the cases, is equipped with an output passive filter. For the voltage controller, the converter is equipped with an LC filter, while an output has an LCL filter for current controller. The important aspect that has been discussed the paper is to avoid computation of unnecessary references using high-pass filters in the feedback loop. The stability of the overall system, including the high-pass filters, has been analyzed. The choice of filter parameters is crucial for achieving desirable system performance. In this paper, the bandwidth of achievable performance is presented through frequency (Bode) plot of the system gains. It has been illustrated that the proposed controllers are capable of tracking fundamental frequency components along with low-order harmonic components. Extensive simulation results are presented to validate the control concepts presented in the paper.
Resumo:
Recent developments in technology, globalization, and consumer activism have challenged the "broadcasting model" of natonally bounded, vertically integrated, monopolistic, expert-paradigm media industries, dedicated to supplying leisure entertainment to more or less passive consumers. Instead, attention has turned to globally traded formats, social network markets, consumer-created content, multiplatform "publication," and a semiotic long tail where niche representations can be as valuable as blockbusters. Such chenges are just as much a challenge to education as they are to business models. And education, both formal and informal, is a dynamic agent in these processes, participation, and creative content require a rethink of "studies" just as much as of "media."
Resumo:
An attempt was made to produce sensitive and specific polyclonal antisera against the viruses causing rice tungro disease, and to assess their potential for use in simple diagnostic tests. Using a multiple, sequential injection procedure, seven batches of polyclonal antisera against rice tungro bacilliform virus (RTBV) and rice tungro spherical virus (RTSV) were produced. These were characterized for their sensitivity and specificity using ring-interface precipitin test and double antibody sandwich (DAS) ELISA. Thirty-one weeks after the first immunization, antiserum batch B6b for RTBV showed the highest ring interface titer (DEP = 1:1920). For RTSV, batches S3, S4b and S5b all had similar titres (DEP = 1:640). In DAS-ELISA, however, significant differences among purified antisera (IgG) batches were observed only at IgG dilution of 10-3. At that dilution, IgGB4b showed the greatest sensitivity, while IgGS3 showed greatest sensitivity for RTSV. When all IgG batches were tested against 11 tungro field isolates (dual RTBV-RTSV infections) at sample dilution of 1:10, IgGB4b and IgGB6b for RTBV and IgGS3 and IgGS6b for RTSV performed equally well. However, after cross adsorption with healthy plant extracts in a specially prepared healthy plant-Sepharose affinity column, only IgGB6b could be used specifically to detect RTBV in a simple tissue-print assay.
Resumo:
Information behaviour (IB) is an area within Library and Information Science that studies the totality of human behaviour in relation to information, both active and passive, along with the explicit and the tacit mental states related to information. This study reports on a recently completed dissertation research that integrates the different models of information behaviours using a diary study where 34 participants maintained a daily journal for two weeks through a web log or paper diary. This resulted in thick descriptions of IB, which were manually analysed using the Grounded Theory method of inquiry, and then cross-referenced through both text-analysis and statistical analysis programs. Among the many key findings of this study, one is the focus this paper: how participants express their feelings of the information seeking process and their mental and affective states related specifically to the sense-making component which co-occurs with almost every other aspect of information behaviour. The paper title – Down the Rabbit Hole and Through the Looking Glass – refers to an observation that some of the participants made in their journals when they searched for, or avoided information, and wrote that they felt like they have fallen into a rabbit hole where nothing made sense, and reported both positive feelings of surprise and amazement, and negative feelings of confusion, puzzlement, apprehensiveness, frustration, stress, ambiguity, and fatigue. The study situates this sense-making aspects of IB within an overarching model of information behaviour that includes IB concepts like monitoring information, encountering information, information seeking and searching, flow, multitasking, information grounds, information horizons, and more, and proposes an integrated model of information behaviour illuminating how these different concepts are interleaved and inter-connected with each other, along with it's implications for information services.
Resumo:
This chapter sets out the debates about the changing role of audiences in relation to user-created content as they appear in New Media and Cultural Studies. The discussion moves beyond the simple dichotomies between active producers and passive audiences, and draws on empirical evidence, in order to examine those practices that are most ordinary and widespread. Building on the knowledge of television’s role in facilitating public life, and the everyday, affective practices through which it is experienced and used, I focus on the way in which YouTube operates as a site of community, creativity and cultural citizenship; and as an archive of popular cultural memory.
Resumo:
In a randomized, double-blind study, 202 healthy adults were randomized to receive a live, attenuated Japanese encephalitis chimeric virus vaccine (JE-CV) and placebo 28 days apart in a cross-over design. A subgroup of 98 volunteers received a JE-CV booster at month 6. Safety, immunogenicity, and persistence of antibodies to month 60 were evaluated. There were no unexpected adverse events (AEs) and the incidence of AEs between JE-CV and placebo were similar. There were three serious adverse events (SAE) and no deaths. A moderately severe case of acute viral illness commencing 39 days after placebo administration was the only SAE considered possibly related to immunization. 99% of vaccine recipients achieved a seroprotective antibody titer ≥ 10 to JE-CV 28 days following the single dose of JE-CV, and 97% were seroprotected at month 6. Kaplan Meier analysis showed that after a single dose of JE-CV, 87% of the participants who were seroprotected at month 6 were still protected at month 60. This rate was 96% among those who received a booster immunization at month 6. 95% of subjects developed a neutralizing titer ≥ 10 against at least three of the four strains of a panel of wild-type Japanese encephalitis virus (JEV) strains on day 28 after immunization. At month 60, that proportion was 65% for participants who received a single dose of JE-CV and 75% for the booster group. These results suggest that JE-CV is safe, well tolerated and that a single dose provides long-lasting immunity to wild-type strains
Resumo:
A randomized, double-blind, study was conducted to evaluate the safety, tolerability and immunogenicity of a live attenuated Japanese encephalitis chimeric virus vaccine (JE-CV) co-administered with live attenuated yellow fever (YF) vaccine (YF-17D strain; Stamaril(®), Sanofi Pasteur) or administered successively. Participants (n = 108) were randomized to receive: YF followed by JE-CV 30 days later, JE followed by YF 30 days later, or the co-administration of JE and YF followed or preceded by placebo 30 days later or earlier. Placebo was used in a double-dummy fashion to ensure masking. Neutralizing antibody titers against JE-CV, YF-17D and selected wild-type JE virus strains was determined using a 50% serum-dilution plaque reduction neutralization test. Seroconversion was defined as the appearance of a neutralizing antibody titer above the assay cut-off post-immunization when not present pre-injection at day 0, or a least a four-fold rise in neutralizing antibody titer measured before the pre-injection day 0 and later post vaccination samples. There were no serious adverse events. Most adverse events (AEs) after JE vaccination were mild to moderate in intensity, and similar to those reported following YF vaccination. Seroconversion to JE-CV was 100% and 91% in the JE/YF and YF/JE sequential vaccination groups, respectively, compared with 96% in the co-administration group. All participants seroconverted to YF vaccine and retained neutralizing titers above the assay cut-off at month six. Neutralizing antibodies against JE vaccine were detected in 82-100% of participants at month six. These results suggest that both vaccines may be successfully co-administered simultaneously or 30 days apart.
Resumo:
As part of a larger indoor environmental study, residential indoor and outdoor levels of nitrogen dioxide (NO2) were measured for 14 houses in a suburb of Brisbane, Queensland, Australia. Passive samplers were used for 48-h sampling periods during the winter of 1999. The average indoor and outdoor NO2 levels were 13.8 ± 6.3 and 16.7 ± 4.2 ppb, respectively. The indoor/outdoor NO2 concentration ratio ranged from 0.4 to 2.3, with a median value of 0.82. The results of statistic analyses indicated that there was no significant correlation between indoor and outdoor NO2 concentrations, or between indoor and fixed site NO2 monitoring station concentrations. However, there was a significant correlation between outdoor and fixed site NO2 monitoring station concentrations. There was also a significant correlation between indoor NO2 concentration and indoor submicrometre (0.007–0.808 μm) aerosol particle number concentrations. The results in this study indicated indoor NO2 levels are significantly affected by indoor NO2 sources, such as a gas stove and cigarette smoking. It implies that the outdoor or fixed site monitoring concentration alone is a poor predictor of indoor NO2 concentration.