114 resultados para Illinois. Division of Air Pollution Control


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Windows are one of the most significant elements in the design of buildings. Whether there are small punched openings in the facade or a completely glazed curtain wall, windows are usually a dominant feature of the building's exterior appearance. From the energy use perspective, windows may also be regarded as thermal holes for a building. Therefore, window design and selection must take both aesthetics and serviceability into consideration. In this paper, using building computer simulation techniques, the effects of glass types on the thermal and energy performance of a sample air-conditioned office building in Australia are studied. It is found that a glass type with lower shading coefficient will have a lower building cooling load and total energy use. Through the comparison of results between current and future weather scenarios, it is identified that the pattern found from the current weather scenario would also exist in the future weather scenario, although the scale of change would become smaller. The possible implication of glazing selection in face of global warming is also examined. It is found that compared with its influence on building thermal performance, its influence on the building energy use is relatively small or insignificant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Exposure to traffic pollution is increasing worldwide as people move to cities, and as more vehicles join the roads, creating longer journeys and more traffic jams. Most traffic pollutants are odourless and invisible, which hides exposure from the public. If traffic pollution had a distinctive smell it would enable people to avoid exposure, and increase the political will for difficult policy changes. A smell may also instigate longer-term changes, such as switching to active transport for school pick-ups. A smell could be added using a fuel additive or a temporary device attached to vehicle exhausts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For many people, a relatively large proportion of daily exposure to a multitude of pollutants may occur inside an automobile. A key determinant of exposure is the amount of outdoor air entering the cabin (i.e. air change or flow rate). We have quantified this parameter in six passenger vehicles ranging in age from 18 years to <1 year, at three vehicle speeds and under four different ventilation settings. Average infiltration into the cabin with all operable air entry pathways closed was between 1 and 33.1 air changes per hour (ACH) at a vehicle speed of 60 km/h, and between 2.6 and 47.3 ACH at 110 km/h, with these results representing the most (2005 Volkswagen Golf) and least air-tight (1989 Mazda 121) vehicles, respectively. Average infiltration into stationary vehicles parked outdoors varied between ~0 and 1.4 ACH and was moderately related to wind speed. Measurements were also performed under an air recirculation setting with low fan speed, while airflow rate measurements were conducted under two non-recirculate ventilation settings with low and high fan speeds. The windows were closed in all cases, and over 200 measurements were performed. The results can be applied to estimate pollutant exposure inside vehicles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The lack of satisfactory consensus for characterizing the system intelligence and structured analytical decision models has inhibited the developers and practitioners to understand and configure optimum intelligent building systems in a fully informed manner. So far, little research has been conducted in this aspect. This research is designed to identify the key intelligent indicators, and develop analytical models for computing the system intelligence score of smart building system in the intelligent building. The integrated building management system (IBMS) was used as an illustrative example to present a framework. The models presented in this study applied the system intelligence theory, and the conceptual analytical framework. A total of 16 key intelligent indicators were first identified from a general survey. Then, two multi-criteria decision making (MCDM) approaches, the analytic hierarchy process (AHP) and analytic network process (ANP), were employed to develop the system intelligence analytical models. Top intelligence indicators of IBMS include: self-diagnostic of operation deviations; adaptive limiting control algorithm; and, year-round time schedule performance. The developed conceptual framework was then transformed to the practical model. The effectiveness of the practical model was evaluated by means of expert validation. The main contribution of this research is to promote understanding of the intelligent indicators, and to set the foundation for a systemic framework that provide developers and building stakeholders a consolidated inclusive tool for the system intelligence evaluation of the proposed components design configurations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The deterioration of air quality is a significant issue in large and growing cities. This work investigates particulate emissions from transport, the largest source of air pollution in cities today. Emitters such as busy roads and diesel trains are investigated, with specific reference to the evolution of particles over time and distance. Diesel trains are investigated as an alternative to road traffic in investigating evolutionary processes. Higher emissions and solitary sources mean that the emitted plume can be observed over time in a single location. These results represent the first investigation of the evolution of fine and ultrafine aerosol particles from this type of source. Aerosols near a busy road are investigated, with the result that a dependence of total number concentration on distance from the road is shown to be related to the fragmentation of nanoparticle clusters. Local meteorological conditions are also monitored and humidity is shown to vary with distance from the road in a nonmonotonic way. Particles from a busy road were also examined using a scanning electron microscope, with the intention of understanding the make up of the emitted aerosol plume. It was determined that due to significant surface behaviour post-deposition, this method of analysis could not directly classify airborne pollutants. Some interesting results were obtained however, particularly in terms of composite particles and the analysis of deposited patterns. This thesis introduces new work in terms of the analysis of diesel train particulate emissions, as well as adding further evidence towards the fragmentation process of aerosol evolution in both background concentrations and emitted aerosol plumes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As global warming entails new conditions for the built environment, the thermal behavior of existing air conditioned office buildings, which are typically designed based on current weather data, may also change. Through building computer simulations, this paper evaluates the impact of global warming on the design and performance of air-conditioned office buildings in Australia, including the increased cooling loads imposed by potential global warming and probable indoor temperature increases due to possible undersized air-conditioning system, as well as the possible change in energy use and CO2 emission of Australian office buildings. It is found that the existing office buildings would generally be able to adapt to the increasing warmth of 2030 year Low and High scenarios projections and 2070 year Low scenario projection. However, for the 2070 year High scenario, the study indicates that the existing office buildings, in all capital cities except for Hobart, will suffer from overheating problems. If the energy source is assumed to be the electricity, it is found that in comparison with current weather scenario, the increased energy uses would translate into the increase of CO2 emissions by 0 to 34.6 kg CO2 equivalent/m2, varying with different future weather scenarios and with different locations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The National Morbidity, Mortality, and Air Pollution Study (NMMAPS) was designed to examine the health effects of air pollution in the United States. The primary question was whether particulate matter was responsible for the associations between air pollution and daily mortality. Secondary questions concerned measurement error in air pollution and mortality displacement.1 Since then, NMMAPS has been used to answer many important questions in environmental epidemiology...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unsteady numerical simulation of Rayleigh Benard convection heat transfer from a 2D channel is performed. The oscillatory behavior is attributed to recirculation of ascending and descending flows towards the core of the channel producing organized rolled motions. Variation of the parameters such as Reynolds number, channel outlet flow area and inclination of the channel are considered. Increasing Reynolds number (for a fixed Rayleigh number), delays the generation of vortices. The reduction in the outflow area leads to the later and the less vortex generation. As the time progresses, more vortices are generated, but the reinforced mean velocity does not let the eddies to enter the core of the channel. Therefore, they attach to the wall and reduce the heat transfer area. The inclination of the channel (both positive and negative) induces the generated vortices to get closer to each other and make an enlarged vortex.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infection control practitioners (ICPs) work across the full spectrum of health care settings and carry out a broad range of practice activities. Whilst several studies have reported on the role of the ICP, there has been little investigation of the scope of infection control practice. This knowledge is essential to inform the professional, legal, educational and financial implications of this specialist role. One hundred and thirteen ICPs from a range of health care settings across Queensland were surveyed. Respondents were asked to rate the extent to which they were and should be engaging in the range of practices identified by Gardner, Jones & Olesen (1999). Significant differences were evident between what ICPs said was their actual practice versus what they thought they should be doing. Overall, the respondents consistently reported that they should be engaging in more of the range of infection control activities than they were, particularly with regard to management practices. A number of differences were found according to the context in which the practitioners worked, such as the type and size of facility and their employment status. The results of this study indicate that the scope of infection control practice has clearly moved beyond those practices that are confined by the hospital wall and defined by surveillance activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This chapter explores the political economy of air pollution. It draws on discourses of power, harm and violence to analyse air pollution within emerging frameworks of 'eco-crime' and atmospheric justice' (see Vanderheiden 2008; Walters 2010). In doing so, it identifies how green criminology continues to push new boundaries by engaging with issues of both global and local concern.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new optimal control model of the interactions between a growing tumour and the host immune system along with an immunotherapy treatment strategy is presented. The model is based on an ordinary differential equation model of interactions between the growing tu- mour and the natural killer, cytotoxic T lymphocyte and dendritic cells of the host immune system, extended through the addition of a control function representing the application of a dendritic cell treat- ment to the system. The numerical solution of this model, obtained from a multi species Runge–Kutta forward-backward sweep scheme, is described. We investigate the effects of varying the maximum al- lowed amount of dendritic cell vaccine administered to the system and find that control of the tumour cell population is best effected via a high initial vaccine level, followed by reduced treatment and finally cessation of treatment. We also found that increasing the strength of the dendritic cell vaccine causes an increase in the number of natural killer cells and lymphocytes, which in turn reduces the growth of the tumour.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the first oil crisis in 1974, economic reasons placed energy saving among the top priorities in most industrialised countries. In the decades that followed, another, equally strong driver for energy saving emerged: climate change caused by anthropogenic emissions, a large fraction of which result from energy generation. Intrinsically linked to energy consumption and its related emissions is another problem: indoor air quality. City dwellers in industrialised nations spend over 90% of their time indoors and exposure to indoor pollutants contributes to ~2.6% of global burden of disease and nearly 2 million premature deaths per year1. Changing climate conditions, together with human expectations of comfortable thermal conditions, elevates building energy requirements for heating, cooling, lighting and the use of other electrical equipment. We believe that these changes elicit a need to understand the nexus between energy consumption and its consequent impact on indoor air quality in urban buildings. In our opinion the key questions are how energy consumption is distributed between different building services, and how the resulting pollution affects indoor air quality. The energy-pollution nexus has clearly been identified in qualitative terms; however the quantification of such a nexus to derive emissions or concentrations per unit energy consumption is still weak, inconclusive and requires forward thinking. Of course, various aspects of energy consumption and indoor air quality have been studied in detail separately, but in-depth, integrated studies of the energy-pollution nexus are hard to come by. We argue that such studies could be instrumental in providing sustainable solutions to maintain the trade-off between the energy efficiency of buildings and acceptable levels of air pollution for healthy living.