122 resultados para INTRAVASCULAR ULTRASOUND ELASTOGRAPHY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Understanding the mechanical properties of tendon is an important step to guiding the process of improving athletic performance, predicting injury and treating tendinopathies. The speed of sound in a medium is governed by the bulk modulus and density for fluids and isotropic materials. However, for tendon,which is a structural composite of fluid and collagen, there is some anisotropy requiring an adjustment for Poisson’s ratio. In this paper, these relationships are explored and modelled using data collected, in vivo, on human Achilles tendon. Estimates for elastic modulus and hysteresis based on speed of sound data are then compared against published values from in vitro mechanical tests. Methods: Measurements using clinical ultrasound imaging, inverse dynamics and acoustic transmission techniques were used to determine dimensions, loading conditions and longitudinal speed of sound for the Achilles tendon during a series of isometric plantar flexion exercises against body weight. Upper and lower bounds for speed of sound versus tensile stress in the tendon were then modelled and estimates derived for elastic modulus and hysteresis. Results: Axial speed of sound varied between 1850 to 2090 m.s−1 with a non-linear, asymptotic dependency on the level of tensile stress in the tendon 5–35 MPa. Estimates derived for the elastic modulus ranged between 1–2 GPa. Hysteresis derived from models of the stress-strain relationship, ranged from 3–11%. These values agree closely with those previously reported from direct measurements obtained via in vitro mechanical tensile tests on major weight bearing tendons. Discussion: There is sufficiently good agreement between these indirect (speed of sound derived) and direct (mechanical tensile test derived) measures of tendon mechanical properties to validate the use of this non-invasive acoustic transmission technique. This non-invasive method is suitable for monitoring changes in tendon properties as predictors of athletic performance, injury or therapeutic progression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Axial acoustic wave propagation has been widely used in evaluating the mechanical properties of human bone in vivo. However, application of this technique to monitor soft tissues, such as tendon, has received comparatively little scientific attention. Laboratory-based research has established that axial acoustic wave transmission is not only related to the physical properties of equine tendon but is also proportional to tensile load to which it is exposed (Miles et al., 1996; Pourcelot et al., 2005). The reproducibility of the technique for in vivo measurements in human tendon, however, has not been established. The aim of this study was to evaluate the limits of agreement for repeated measures of the speed of sound (SoS) in human Achilles tendon in vivo. Methods: A custom built ultrasound device, consisting of an A-mode 1MHz emitter and two regularly spaced receivers, was used to measure the SoS in the mid-portion of the Achilles tendon in ten healthy males and ten females (mean age: 33.8 years, range 23-56 yrs; height: 1.73±0.08 m; weight: 68.4±15.3 kg). The emitter and receivers were held at fixed positions by a polyethylene frame and maintained in close contact with the skin overlying the tendon by means of elasticated straps. Repeated SoS measurements were taken with the subject prone (non-weightbearing and relaxed Achilles tendon) and during quiet bipedal and unipedal stance. In each instance, the device was detached and repositioned prior to measurement. Results: Limits of agreement for repeated SoS measures during non-weightbearing and bipedal and unipedal stance were ±53, ±28 and ±21 m/s, respectively. The average SoS in the non-weightbearing Achilles tendon was 1804±198 m/s. There was a significant increase in the average SoS during bilateral (2122±135 m/s) (P < 0.05) and unilateral (2221±79 m/s) stance (P < 0.05). Conclusions: Repeated SoS measures in human Achilles tendon were more reliable during stance than under non-weightbearing conditions. These findings are consistent with previous research in equine tendon in which lower variability in SoS was observed with increasing tensile load (Crevier-Denoix et al, 2009). Since the limits of agreement for Achilles tendon SoS are nearly 5% of the changes previously observed during walking and therapeutic heel raise exercises, acoustic wave transmission provides a promising new non-invasive method for determining tendon properties during sports and rehabilitation related activities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monitoring fetal wellbeing is a compelling problem in modern obstetrics. Clinicians have become increasingly aware of the link between fetal activity (movement), well-being, and later developmental outcome. We have recently developed an ambulatory accelerometer-based fetal activity monitor (AFAM) to record 24-hour fetal movement. Using this system, we aim at developing signal processing methods to automatically detect and quantitatively characterize fetal movements. The first step in this direction is to test the performance of the accelerometer in detecting fetal movement against real-time ultrasound imaging (taken as the gold standard). This paper reports first results of this performance analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The human patellar tendon is highly adaptive to changes in habitual loading but little is known about its acute mechanical response to exercise. This research evaluated the immediate transverse strain response of the patellar tendon to a bout of resistive quadriceps exercise. Methods: Twelve healthy adult males (mean age 34.0+/-12.1 years, height 1.75+/-0.09 m and weight 76.7+/-12.3 kg) free of knee pain participated in the research. A 10-5 MHz linear-array transducer was used to acquire standardised sagittal sonograms of the right patellar tendon immediately prior to and following 90 repetitions of a double-leg parallel-squat exercise performed against a resistance of 175% bodyweight. Tendon thickness was determined 20-mm distal to the pole of the patellar and transverse Hencky strain was calculated as the natural log of the ratio of post- to pre-exercise tendon thickness and expressed as a percentage. Measures of tendon echotexture (echogenicity and entropy) were also calculated from subsequent gray-scale profiles. Results: Quadriceps exercise resulted in an immediate decrease in patellar tendon thickness (P<.05), equating to a transverse strain of -22.5+/-3.4%, and was accompanied by increased tendon echogenicity (P<.05) and decreased entropy (P<.05). The transverse strain response of the patellar tendon was significantly correlated with both tendon echogenicity (r = -0.58, P<.05) and entropy following exercise (r=0.73, P<.05), while older age was associated with greater entropy of the patellar tendon prior to exercise (r=0.79, P<.05) and a reduced transverse strain response (r=0.61, P<.05) following exercise. Conclusions: This study is the first to show that quadriceps exercise invokes structural alignment and fluid movement within the matrix that are manifest by changes in echotexture and transverse strain in the patellar tendon., (C)2012The American College of Sports Medicine

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While Magentic Resonance Imaging and Ultrasound are used extensively for non-acute shoulder imaging, plain images are regularly required as a first investigation. This paper presents a snapshot of the diversity of projections performed and a review of the current evidence of the most appropriate projections. The projections recommended are suitable as a first investigation, and also to complement more advanced imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background—Palpation is an important clinical test for jumper's knee. Objectives—To (a) test the reproducibility of palpation tenderness, (b) evaluate the sensitivity and specificity of palpation in subjects with clinical symptoms of jumper's knee, and (c) determine whether tenderness to palpation may serve as a useful screening test for patellar tendinopathy. The yardstick for diagnosis of patellar tendinopathy was ultrasonographic abnormality. Methods—In 326 junior symptomatic and asymptomatic athletes' tendons, palpation was performed by a single examiner before ultrasonographic examination by a certified ultrasound radiologist. In 58 tendons, palpation was performed twice to test reliability. Tenderness to palpation was scored on a scale from 0 to 3 where 0 represented no pain, and 1, 2, and 3 represented mild, moderate, and severe tenderness respectively. Results—Patellar tendon palpation was a reliable examination for a single examiner (Pearson r = 0.82). In symptomatic tendons, the positive predictive value of palpation was 68%. As a screening examination in asymptomatic subjects, the positive predictive value of tendon palpation was 36–38%. Moderate and severe palpation tenderness were better predictors of ultrasonographic tendon pathology than absent or mild tenderness (p<0.001). Tender and symptomatic tendons were more likely to have ultrasound abnormality than tenderness alone (p<0.01). Conclusions—In this age group, palpation is a reliable test but it is not cost effective in detecting patellar tendinopathy in a preparticipation examination. In symptomatic tendons, palpation is a moderately sensitive but not specific test. Mild tenderness in the patellar tendons in asymptomatic jumping athletes should be considered normal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main contribution of this project was to investigate power electronics technology in designing and developing high frequency high power converters for industrial applications. Therefore, the research was conducted at two levels; first at system level which mainly encapsulated the circuit topology and control scheme and second at application level which involves with real-world applications. Pursuing these objectives, varied topologies have been developed and proposed within this research. The main aim was to resolving solid-state switches limited power rating and operating speed while increasing the system flexibility considering the application characteristics. The developed new power converter configurations were applied to pulsed power and high power ultrasound applications for experimental validation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To compare patellar tendon sonographic findings in active, currently asymptomatic, elite athletes with those in nonathletic controls. DESIGN: Cross-sectional cohort study with convenience control sample. SETTING: The Victorian Institute of Sport Tendon Study Group, an institutional elite athlete study group in Australia. PATIENTS AND PARTICIPANTS: Two hundred elite male and female athletes from the sports of basketball, cricket, netball, and Australian rules football. Forty athletes who had current symptoms of jumper's knee were excluded from analysis, leaving 320 subject tendons in athletes who were currently asymptomatic. Twenty-seven nonathletic individuals served as controls. MAIN OUTCOME MEASURE: Sonographic patellar tendon appearance. We measured the dimensions of subject tendons and noted the presence or absence of hypoechoic regions and tendon calcification. Dimensions of hypoechoic regions were measured, and approximate cross-sectional areas were calculated. Chi-squared analysis was used to test the prevalence of hypoechoic regions in subjects and controls and men and women. RESULTS: In currently asymptomatic subjects, hypoechoic regions were more prevalent in athlete tendons (22%) than in controls (4%), in male subject tendons (30%) than in female subjects (14%), and in basketball players (32%) than in other athletes (9%) (all p < 0.01). Bilateral tendon abnormalities were equally prevalent in men and women but more prevalent in basketball players (15%) than in other athletes (3%) (p < 0.05). Sonographic hypoechoic regions were present in 35 of 250 (14%) patellar tendons in athletes who had never had anterior knee pain. CONCLUSIONS: Patellar tendon sonographic hypoechoic areas were present in asymptomatic patellar tendons of a proportion of elite athletes but rarely present in controls. This has implications for clinicians managing athletes with anterior knee pain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the ability of ultrasonography to predict eventual symptoms in an at-risk population, 52 elite junior basketball players' patellar tendons were studied at baseline and again 16 months later. The group consisted of 10 study tendons (ultrasonographically hypoechoic at baseline) and 42 control tendons (ultrasonographically normal at baseline). By design, all tendons were asymptomatic at baseline. No differences were noted between subjects and controls at baseline for age, height, weight, training hours, and vertical jump. Functional (P < 0.01) and symptomatic outcome (P < 0.05) were poorer for subjects' tendons than for controls. Relative risk for developing symptoms of jumper's knee was 4.2 times greater in case tendons than in control tendons. Men were more likely to develop ultrasonographic changes than women (P < 0.025), and they also had significantly increased training hours per week (P < 0.01) in the study period. Half (50%) of abnormal tendons in women became ultrasonographically normal in the study period. Our data suggest that presence of an ultrasonographic hypoechoic area is associated with a greater risk of developing jumper's knee symptoms. Ultrasonographic patellar tendon changes may resolve, but this is not necessary for an athlete to become asymptomatic. Qualitative or quantitative analysis of baseline ultrasonographic images revealed it was not possible to predict which tendons would develop symptoms or resolve ultrasonographically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background No study relating the changes obtained in the architecture of erector spinae (ES) muscle were registered with ultrasound and different intensities of muscle contraction recorded by surface EMG (electromyography) on the ES muscle was found. The aim of this study was analyse the relationship in the response of the ES muscle during isometric moderate and light lumbar isometric extension considering architecture and functional muscle variables. Methods Cross-sectional study. 46 subjects (52% men) with a group mean age of 30.4 (±7.78). The participants developed isometric lumbar extension while performing moderate and low isometric trunk and hip extension in a sitting position with hips flexed 90 degrees and the lumbar spine in neutral position. During these measurements, electromyography recordings and ultrasound images were taken bilaterally. Bilaterally pennation angle, muscle thickness, torque and muscle activation were measured. This study was developed at the human movement analysis laboratory of the Health Science Faculty of the University of Malaga (Spain). Results Strong and moderate correlations were found at moderate and low intensities contraction between the variable of the same intensity, with correlation values ranging from 0.726 (Torque Moderate – EMG Left Moderate) to 0.923 (Angle Left Light – Angle Right Light) (p < 0.001). This correlation is observed between the variables that describe the same intensity of contraction, showing a poor correlation between variables of different intensities. Conclusion There is a strong relationship between architecture and function variables of ES muscle when describe an isometric lumbar extension at light or moderate intensity. Keywords: Ultrasonography; Surface electromyography; Thickness; Pennation angle; Erector spinae

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present an electrochemical exfoliation method to produce controlled thickness graphene flakes by ultrasound assistance. Bilayer graphene flakes are dominant in the final product by using sonication during the electrochemical exfoliation process, while without sonication the product contains a larger percentage of four-layer graphene flakes. Graphene sheets prepared by using the two procedures are processed into films to measure their respective sheet resistance and optical transmittance. Solid-state electrolyte supercapacitors are made using the two types of graphene films. Our study reveals that films with a higher content of multilayer graphene flakes are more conductive, and their resistance is more easily reduced by thermal annealing, making them suitable as transparent conducting films. The film with higher content of bilayer graphene flakes shows instead higher capacitance when used as electrode in a supercapacitor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives The purpose of the study was to establish regression equations that could be used to predict muscle thickness and pennation angle at different intensities from electromyography (EMG) based measures of muscle activation during isometric contractions. Design Cross-sectional study. Methods Simultaneous ultrasonography and EMG were used to measure pennation angle, muscle thickness and muscle activity of the rectus femoris and vastus lateralis muscles, respectively, during graded isometric knee extension contractions performed on a Cybex dynamometer. Data form fifteen male soccer players were collected in increments of approximately 25% intensity of the maximum voluntary contraction (MVC) ranging from rest to MVC. Results There was a significant correlation (P < 0.05) between ultrasound predictors and EMG measures for the muscle thickness of rectus femoris with an R2 value of 0.68. There was no significant correlation (P > 0.05) between ultrasound pennation angle for the vastus lateralis predictors for EMG muscle activity with an R2 value of 0.40. Conclusions The regression equations can be used to characterise muscle thickness more accurately and to determine how it changes with contraction intensity, this provides improved estimates of muscle force when using musculoskeletal models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Contrast enhanced echocardiography (CEE) is utilised when sub-optimal image quality results in non-diagnostic echocardiograms. However, there have been numerous safety notices issued by regulatory authorities regarding rare but potentially serious adverse reactions (AR). This multi-centre, retrospective analysis was performed to assess the short-term safety of CEE in a broad range of indications. Methods All CEE performed over 58 months at three institutions were assessed for AR within 30 min. Results A total of 5956 CEE were performed in 5576 patients. A total of 4903 were stress CEE and 1053 resting CCE.Bolus administration in 5719, infusion in 237 cases; 89.9% of CCE were outpatients. Commonest CEE indication was functional stress testing (82.3%). There were 16 AR related to CEE (0.27%). All AR were mild, transient and all patients made a full recovery. No cases of serious anaphylaxis or death within 30 min of contrast administration. Comparing those with and without an AR, there were no significant differences in age, gender, BMI, LVEF, patient location, exam type or RVSP. There was a slightly increased likelihood of an AR during infusion versus bolus dosing (p = 0.02). Conclusion CEE is a safe investigation in a broad range of indications and clinical scenarios. AR are very rare, mild and transient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Ankle joint equinus, or restricted dorsiflexion range of motion (ROM), has been linked to a range of pathologies of relevance to clinical practitioners. This systematic review and meta-analysis investigated the effects of conservative interventions on ankle joint ROM in healthy individuals and athletic populations. METHODS: Keyword searches of Embase Medline Cochrane and CINAHL databases were performed with the final search being run in August 2013. Studies were eligible for inclusion if they assessed the effect of a non-surgical intervention on ankle joint dorsiflexion in healthy populations. Studies were quality rated using a standard quality assessment scale. Standardised mean differences (SMDs) and 95% confidence intervals (CIs) were calculated and results were pooled where study methods were homogenous. RESULTS: Twenty-three studies met eligibility criteria, with a total of 734 study participants. Results suggest that there is some evidence to support the efficacy of static stretching alone (SMDs: range 0.70 to 1.69) and static stretching in combination with ultrasound (SMDs: range 0.91 to 0.95), diathermy (SMD 1.12), diathermy and ice (SMD 1.16), heel raise exercises (SMDs: range 0.70 to 0.77), superficial moist heat (SMDs: range 0.65 to 0.84) and warm up (SMD 0.87) in improving ankle joint dorsiflexion ROM. CONCLUSIONS: Some evidence exists to support the efficacy of stretching alone and stretching in combination with other therapies in increasing ankle joint ROM in healthy individuals. There is a paucity of quality evidence to support the efficacy of other non-surgical interventions, thus further research in this area is warranted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. In isotropic materials, the speed of acoustic wave propagation is governed by the bulk modulus and density. For tendon, which is a structural composite of fluid and collagen, however, there is some anisotropy requiring an adjustment for Poisson's ratio. This paper explores these relationships using data collected, in vivo, on human Achilles tendon and then compares estimates of elastic modulus and hysteresis against published values from in vitro mechanical tests. Methods. Measurements using conventional B-model ultrasound imaging, inverse dynamics and acoustic transmission techniques were used to determine dimensions, loading conditions and longitudinal speed of sound in the Achilles tendon during a series of isometric plantar flexion exercises against body weight. Upper and lower bounds for speed of sound versus tensile stress in the tendon were then modelled and estimates of the elastic modulus and hysteresis of the Achilles tendon derived. Results. Axial speed of sound varied between 1850 and 2090 ms-1 with a non-linear, asymptotic dependency on the level of tensile stress (5-35 MPa) in the tendon. Estimates derived for the elastic modulus of the Achilles tendon ranged between 1-2 GPa. Hysteresis derived from models of the stress-strain relationship, ranged from 3-11%. Discussion. Estimates of elastic modulus agree closely with those previously reported from direct measurements obtained via mechanical tensile tests on major weight bearing tendons in vitro [1,2]. Hysteresis derived from models of the stress-strain relationship is consistent with direct measures from various mamalian tendon (7-10%) but is lower than previous estimates in human tendon (17-26%) [3]. This non-invasive method would appear suitable for monitoring changes in tendon properties during dynamic sporting activities.