89 resultados para Equilibrium Thickness
Resumo:
High mechanical stress in atherosclerotic plaques at vulnerable sites, called critical stress, contributes to plaque rupture. The site of minimum fibrous cap (FC) thickness (FCMIN) and plaque shoulder are well-documented vulnerable sites. The inherent weakness of the FC material at the thinnest point increases the stress, making it vulnerable, and it is the big curvature of the lumen contour over FC which may result in increased plaque stress. We aimed to assess critical stresses at FCMIN and the maximum lumen curvature over FC (LCMAX) and quantify the difference to see which vulnerable site had the highest critical stress and was, therefore, at highest risk of rupture. One hundred patients underwent high resolution carotid magnetic resonance (MR) imaging. We used 352 MR slices with delineated atherosclerotic components for the simulation study. Stresses at all the integral nodes along the lumen surface were calculated using the finite-element method. FCMIN and LCMAX were identified, and critical stresses at these sites were assessed and compared. Critical stress at FC MIN was significantly lower than that at LCMAX (median: 121.55 kPa; inter quartile range (IQR) = [60.70-180.32] kPa vs. 150.80 kPa; IQR = [91.39-235.75] kPa, p < 0.0001). If critical stress at FCMIN was only used, then the stress condition of 238 of 352 MR slices would be underestimated, while if the critical stress at LCMAX only was used, then 112 out of 352 would be underestimated. Stress analysis at FCMIN and LCMAX should be used for a refined mechanical risk assessment of atherosclerotic plaques, since material failure at either site may result in rupture.
Resumo:
Background and Purpose Acute cerebral ischemic events are associated with rupture of vulnerable carotid atheroma and subsequent thrombosis. Factors such as luminal stenosis and fibrous cap thickness have been thought to be important risk factors for plaque rupture. We used a flow-structure interaction model to simulate the interaction between blood flow and atheromatous plaque to evaluate the effect of the degree of luminal stenosis and fibrous cap thickness on plaque vulnerability. Methods A coupled nonlinear time-dependent model with a flow-plaque interaction simulation was used to perform flow and stress/strain analysis in a stenotic carotid artery model. The stress distribution within the plaque and the flow conditions within the vessel were calculated for every case when varying the fibrous cap thickness from 0.1 to 2 mm and the degree of luminal stenosis from 10% to 95%. A rupture stress of 300 kPa was chosen to indicate a high risk of plaque rupture. A 1-sample t test was used to compare plaque stresses with the rupture stress. Results High stress concentrations were found in the plaques in arteries with >70% degree of stenosis. Plaque stresses in arteries with 30% to 70% stenosis increased exponentially as fibrous cap thickness decreased. A decrease of fibrous cap thickness from 0.4 to 0.2 mm resulted in an increase of plaque stress from 141 to 409 kPa in a 40% degree stenotic artery. Conclusions There is an increase in plaque stress in arteries with a thin fibrous cap. The presence of a moderate carotid stenosis (30% to 70%) with a thin fibrous cap indicates a high risk for plaque rupture. Patients in the future may be risk stratified by measuring both fibrous cap thickness and luminal stenosis.
Resumo:
This paper is concerned with the study of the equilibrium exchange of ammonium ions with two natural zeolite samples sourced in Australia from Castle Mountain Zeolites and Zeolite Australia. A range of sorption models including Langmuir Vageler, Competitive Langmuir, Freundlich, Temkin, Dubinin Astakhov and Brouers–Sotolongo were applied in order to gain an insight as to the exchange process. In contrast to most previous studies, non-linear regression was used in all instances to determine the best fit of the experimental data. Castle Mountain natural zeolite was found to exhibit higher ammonium capacity than Zeolite Australia material when in the freshly received state, and this behavior was related to the greater amount of sodium ions present relative to calcium ions on the zeolite exchange sites. The zeolite capacity for ammonium ions was also found to be dependent on the solution normality, with 35–60% increase inuptake noted when increasing the ammonium concentration from 250 to 1000 mg/L. The optimal fit ofthe equilibrium data was achieved by the Freundlich expression as confirmed by use of Akaikes Information Criteria. It was emphasized that the bottle-point method chosen influenced the isotherm profile in several ways, and could lead to misleading interpretation of experiments, especially if the constant zeolite mass approach was followed. Pre-treatment of natural zeolite with acid and subsequently sodium hydroxide promoted the uptake of ammonium species by at least 90%. This paper highlighted the factors which should be taken into account when investigating ammonium ion exchange with natural zeolites.
Resumo:
In the fields of organic electronics and biotechnology, applications for organic polymer thin films fabricated using low-temperature non-equilibrium plasma techniques are gaining significant attention because of the physical and chemical stability of thin films and the low cost of production. Polymer thin films were fabricated from non-synthetic terpinen-4-ol using radiofrequency polymerization (13.56 MHz) on low loss dielectric substrates and their permittivity properties were ascertained to determine potential applications for these organic films. Real and imaginary parts of permittivity as a function of frequency were measured using the variable angle spectroscopic ellipsometer. The real part of permittivity (k) was found to be between 2.34 and 2.65 in the wavelength region of 400–1100 nm, indicating a potential low-k material. These permittivity values were confirmed at microwave frequencies. Dielectric properties of polyterpenol films were measured by means of split post dielectric resonators (SPDRs) operating at frequencies of 10 GHz and 20 GHz. Permittivity increased for samples deposited at higher RF energy – from 2.65 (25 W) to 2.83 (75 W) measured by a 20-GHz SPDR and from 2.32 (25 W) to 2.53 (100 W) obtained using a 10-GHz SPDR. The error in permittivity measurement was predominantly attributed to the uncertainty in film thickness measurement.
Resumo:
Purpose To examine whether anterior scleral and conjunctival thickness undergoes significant diurnal variation over a 24-hour period. Methods Nineteen healthy young adults (mean age 22 ± 2 years) with minimal refractive error (mean spherical equivalent refraction -0.08 ± 0.39 D), had measures of anterior scleral and conjunctival thickness collected using anterior segment optical coherence tomography (AS-OCT) at seven measurement sessions over a 24-hour period. The thickness of the temporal anterior sclera and conjunctiva were determined at 6 locations (each separated by 0.5 mm) at varying distances from the scleral spur for each subject at each measurement session. Results Both the anterior sclera and conjunctiva were found to undergo significant diurnal variations in thickness over a 24-hour period (both p <0.01). The sclera and conjunctiva exhibited a similar pattern of diurnal change, with a small magnitude thinning observed close to midday, and a larger magnitude thickening observed in the early morning immediately after waking. The amplitude of diurnal thickness change was larger in the conjunctiva (mean amplitude 69 ± 29 μm) compared to the sclera (21 ± 8 μm). The conjunctiva exhibited its smallest magnitude of change at the scleral spur location (mean amplitude 56 ± 17 μm) whereas the sclera exhibited its largest magnitude of change at this location (52 ± 21 μm). Conclusions This study provides the first evidence of diurnal variations occurring in the thickness of the anterior sclera and conjunctiva. Studies requiring precise measures of these anatomical layers should therefore take time of day into consideration. The majority of the observed changes occurred in the early morning immediately after waking and were of larger magnitude in the conjunctiva compared to the sclera. Thickness changes at other times of the day were of smaller magnitude and generally not statistically significant.
Resumo:
Thickness measurements derived from optical coherence tomography (OCT) images of the eye are a fundamental clinical and research metric, since they provide valuable information regarding the eye’s anatomical and physiological characteristics, and can assist in the diagnosis and monitoring of numerous ocular conditions. Despite the importance of these measurements, limited attention has been given to the methods used to estimate thickness in OCT images of the eye. Most current studies employing OCT use an axial thickness metric, but there is evidence that axial thickness measures may be biased by tilt and curvature of the image. In this paper, standard axial thickness calculations are compared with a variety of alternative metrics for estimating tissue thickness. These methods were tested on a data set of wide-field chorio-retinal OCT scans (field of view (FOV) 60° x 25°) to examine their performance across a wide region of interest and to demonstrate the potential effect of curvature of the posterior segment of the eye on the thickness estimates. Similarly, the effect of image tilt was systematically examined with the same range of proposed metrics. The results demonstrate that image tilt and curvature of the posterior segment can affect axial tissue thickness calculations, while alternative metrics, which are not biased by these effects, should be considered. This study demonstrates the need to consider alternative methods to calculate tissue thickness in order to avoid measurement error due to image tilt and curvature.
Resumo:
PURPOSE To examine longitudinal changes in choroidal thickness and axial length in a population of children with a range of refractive errors. METHODS One hundred and one children (41 myopes and 60 nonmyopes) aged 10 to 15 years participated in this prospective, observational longitudinal study. For each child, 6-month measures of choroidal thickness (using enhanced depth imaging optical coherence tomography) and axial ocular biometry were collected four times over an 18-month period. Linear mixed-models were used to examine the longitudinal changes in choroidal thickness and the relationship between changes in choroidal thickness and axial eye growth over the study period. RESULTS A significant group mean increase in subfoveal choroidal thickness was observed over 18 months (mean increase 13 6 22 lm, P < 0.001). Myopic children exhibited significantly thinner choroids compared with nonmyopic children (P < 0.001), although there was no significant time by refractive group interaction (P ¼ 0.46), indicating similar changes in choroidal thickness over time in myopes and nonmyopes. However, a significant association between the change in choroidal thickness and the change in axial length over time was found (P < 0.001, β = −0.14). Children showing faster axial eye growth exhibited significantly less choroidal thickening over time compared with children showing slower axial eye growth. CONCLUSIONS A significant increase in choroidal thickness occurs over an 18-month period in normal 10- to 15-year-old children. Children undergoing faster axial eye growth exhibited less thickening and, in some cases, a thinning of the choroid. These findings support a potential role for the choroid in the mechanisms regulating eye growth in childhood.
Resumo:
To develop and compare a set of metrics for calculating tissue thickness in wide-field OCT data.
Resumo:
• Evidence from cross-sectional studies1,2 suggests that choroidal thickness (ChT) varies with age and refractive error in childhood. However, to date there have been no longitudinal studies examining changes in pediatric ChT. • In this prospective study, the longitudinal changes in ChT and its relationship with eye growth were examined in a population of normal children with a range of refractive errors.
Resumo:
This study reports an investigation of the ion exchange treatment of sodium chloride solutions in relation to use of resin technology for applications such as desalination of brackish water. In particular, a strong acid cation (SAC) resin (DOW Marathon C) was studied to determine its capacity for sodium uptake and to evaluate the fundamentals of the ion exchange process involved. Key questions to answer included: impact of resin identity; best models to simulate the kinetics and equilibrium exchange behaviour of sodium ions; difference between using linear least squares (LLS) and non-linear least squares (NLLS) methods for data interpretation; and, effect of changing the type of anion in solution which accompanied the sodium species. Kinetic studies suggested that the exchange process was best described by a pseudo first order rate expression based upon non-linear least squares analysis of the test data. Application of the Langmuir Vageler isotherm model was recommended as it allowed confirmation that experimental conditions were sufficient for maximum loading of sodium ions to occur. The Freundlich expression best fitted the equilibrium data when analysing the information by a NLLS approach. In contrast, LLS methods suggested that the Langmuir model was optimal for describing the equilibrium process. The Competitive Langmuir model which considered the stoichiometric nature of ion exchange process, estimated the maximum loading of sodium ions to be 64.7 g Na/kg resin. This latter value was comparable to sodium ion capacities for SAC resin published previously. Inherent discrepancies involved when using linearized versions of kinetic and isotherm equations were illustrated, and despite their widespread use, the value of this latter approach was questionable. The equilibrium behaviour of sodium ions form sodium fluoride solution revealed that the sodium ions were now more preferred by the resin compared to the situation with sodium chloride. The solution chemistry of hydrofluoric acid was suggested as promoting the affinity of the sodium ions to the resin.
Resumo:
INTRODUCTION There is a paucity of research investigating the scar outcome of children with partial thickness burns. The aim of this study was to assess the scar outcome of children with partial thickness burns who received a silver dressing acutely. METHOD Children aged 0-15 years with an acute partial thickness burn, ≤10% TBSA were included. Children were originally recruited for an RCT investigating three dressings for partial thickness burns. Children were assessed at 3 and 6 months after re-epithelialization. 3D photographs were taken of the burn site, POSAS was completed and skin thickness was measured using ultrasound imaging. RESULTS Forty-three children returned for 3 and 6 month follow-ups or returned a photo. Days to re-epithelialization was a significant predictor of skin/scar quality at 3 and 6 months (p<0.01). Patient-rated color and observer-rated vascularity and pigmentation POSAS scores were comparable at 3 months (color vs. vascularity 0.88, p<0.001; color vs. pigmentation 0.64, p<0.001), but patients scored higher than the observer at 6 months (color vs. vascularity 0.57, p<0.05; color vs. pigmentation 0.15, p=0.60). Burn depth was significantly correlated with skin thickness (r=0.51, p<0.01). Hypopigmentation of the burn site was present in 25.8% of children who re-epithelialized in ≤2 weeks. CONCLUSION This study has provided information on outcomes for children with partial thickness burns and highlighted a need for further education of this population.
Resumo:
BACKGROUND This study compared the effects of three silver dressing combinations on small to medium size acute partial thickness burns in children, focusing on re-epithelialization time, pain and distress during dressing changes. METHOD Children (0-15 years) with clean, ≤ 10% total body surface area (TBSA) partial thickness burns who met the inclusion criteria were included in the study. Children received either (1) Acticoat™; (2) Acticoat™ with Mepitel™; or (3) Mepilex Ag™ dressings. Measures of burn re-epithelialization, pain, and distress were recorded at dressing changes every 3-5 days until full re-epithelialization occurred. RESULTS One hundred and three children were recruited with 96 children included for analysis. No infections were detected for the course of the study. When adjusted for burn depth, Acticoat™ significantly increased the expected days to full re-epithelialization by 40% (IRR = 1.40; 95% CI: 1.14-1.73, p < 0.01) and Acticoat™ with Mepitel™ significantly increased the expected days to full re-epithelialization by 33% (IRR = 1.33; 95% CI: 1.08-1.63, p ≤ 0.01) when compared to Mepilex Ag™. Expected FLACC scores in the Mepilex Ag™ group were 32% lower at dressing removal (p = 0.01) and 37% lower at new dressing application (p = 0.04); and scores in the Acticoat™ with Mepitel™ group were 23% lower at dressing removal (p = 0.04) and 40% lower at new dressing application (p < 0.01), in comparison to the Acticoat™ group. Expected Visual Analog Scale-Pain (VAS-P) scores were 25% lower in the Mepilex Ag™ group at dressing removal (p = 0.04) and 34% lower in the Acticoat™ with Mepitel™ group (p = 0.02) at new dressing application in comparison to the Acticoat™ group. There was no significant difference between the Mepilex Ag™ and the Acticoat™ with Mepitel™ groups at all timepoints and with any pain measure. CONCLUSION Mepilex Ag™ is an effective silver dressing, in terms of accelerated wound re-epithelialization time (compared to Acticoat™ and Acticoat™ with Mepitel™) and decreased pain during dressing changes (compared to Acticoat™), for clean, < 10% TBSA partial thickness burns in children.
Resumo:
The aim of this paper is to assess the heritability of cerebral cortex, based on measurements of grey matter (GM) thickness derived from structural MR images (sMRI). With data acquired from a large twin cohort (328 subjects), an automated method was used to estimate the cortical thickness, and EM-ICP surface registration algorithm was used to establish the correspondence of cortex across the population. An ACE model was then employed to compute the heritability of cortical thickness. Heritable cortical thickness measures various cortical regions, especially in frontal and parietal lobes, such as bilateral postcentral gyri, superior occipital gyri, superior parietal gyri, precuneus, the orbital part of the right frontal gyrus, right medial superior frontal gyrus, right middle occipital gyrus, right paracentral lobule, left precentral gyrus, and left dorsolateral superior frontal gyrus.
Resumo:
Mobile applications are being increasingly deployed on a massive scale in various mobile sensor grid database systems. With limited resources from the mobile devices, how to process the huge number of queries from mobile users with distributed sensor grid databases becomes a critical problem for such mobile systems. While the fundamental semantic cache technique has been investigated for query optimization in sensor grid database systems, the problem is still difficult due to the fact that more realistic multi-dimensional constraints have not been considered in existing methods. To solve the problem, a new semantic cache scheme is presented in this paper for location-dependent data queries in distributed sensor grid database systems. It considers multi-dimensional constraints or factors in a unified cost model architecture, determines the parameters of the cost model in the scheme by using the concept of Nash equilibrium from game theory, and makes semantic cache decisions from the established cost model. The scenarios of three factors of semantic, time and locations are investigated as special cases, which improve existing methods. Experiments are conducted to demonstrate the semantic cache scheme presented in this paper for distributed sensor grid database systems.