126 resultados para Employees -- Rating of
Resumo:
Voltage Unbalance (VU) is a power quality issue arising within the low voltage residential distribution networks due to the random location and rating of single-phase rooftop photovoltaic cells (PVs). In this paper, an analysis has been carried out to investigate how PV installations, their random location and power generation capacity can cause an increase in VU. Several efficient practical methods are discussed for VU reduction. Based on this analysis, it has been shown that the installation of a DSTATCOM can reduce VU. In this paper, the best possible location for DSTATCOM and its efficient control method to reduce VU will be presented. The results are verified through PSCAD/EMTDC and Monte Carlo simulations.
Resumo:
INTRODUCTION: Recent events have heightened awareness of disaster health issues and the need to prepare the health workforce to plan for and respond to major incidents. This has been reinforced at an international level by the World Association for Disaster and Emergency Medicine, which has proposed an international educational framework. ----------- OBJECTIVE: The aim of this paper is to outline the development of a national educational framework for disaster health in Australia. ----------- METHODS: The framework was developed on the basis of the literature and the previous experience of members of a National Collaborative for Disaster Health Education and Research. The Collaborative was brought together in a series of workshops and teleconferences, utilizing a modified Delphi technique to finalize the content at each level of the framework and to assign a value to the inclusion of that content at the various levels. ----------- FRAMEWORK: The framework identifies seven educational levels along with educational outcomes for each level. The framework also identifies the recommended contents at each level and assigns a rating of depth for each component. The framework is not intended as a detailed curriculum, but rather as a guide for educationalists to develop specific programs at each level. ----------- CONCLUSIONS: This educational framework will provide an infrastructure around which future educational programs in Disaster Health in Australia may be designed and delivered. It will permit improved articulation for students between the various levels and greater consistency between programs so that operational responders may have a consistent language and operational approach to the management of major events.
Resumo:
Introduction: Previous studies investigating mothers’ sleep in the postpartum period commonly demonstrated elevated levels of sleepiness in this population. A Karolinska Sleepiness Scale (KSS) rating of 5 or above is associated with an exponential increase in vehicle crash risk. To date, no studies have investigated the relationship between mothers’ sleep in the postpartum period and their driving behaviour. Methods: Sleep-wake diary data was collected from 14 mother-infant dyads during two 7-day assessment periods when the infants were 6 and 12 weeks old. The mothers’ indicated all driving episodes during these weeks and their respective sleepiness level using the KSS. Semi-structured interviews were conducted with the mothers when their infant was 12 weeks old. Results: The infants slept significantly more than their mothers at 6 weeks and 12 weeks of age. During both time points, mothers and infants had a similar number of night awakenings (waking between 22:00 and 06:00), with some mothers experiencing greater than 19 awakenings over 7 nights. Notably, 36% of the mothers did not experience a continuous sleep period longer than 4.5 hours when their infant was 6 weeks old. A total of 141 driving episodes were reported during the 7 day assessment period when the infants were 6 weeks old. Over 50% of the driving episodes were denoted with a KSS score of 5 or above. Strategies mothers cited they employed during this period included only driving when feeling alert, postponing driving until another person is present, and driving in the morning when less sleepy. Conclusion: Mothers are experiencing disrupted sleep at night and some mothers do not obtain more than 4.5 hours of continuous sleep during the early postpartum weeks. In this sample, some mothers reported self-regulating driving behaviour, however over half of the driving episodes were undertaken with a sleepiness rating linked with elevated crash risk.
Resumo:
Purpose To compare self-reported driving ability with objective measures of on-road driving performance in a large cohort of older drivers. Methods 270 community-living adults aged 70 – 88 years recruited via the electoral roll completed a standardized assessment of on-road driving performance and questionnaires determining perceptions of their own driving ability, confidence and driving difficulties. Retrospective self-reported crash data over the previous five years were recorded. Results Participants reported difficulty with only selected driving situations, including driving into the sun, in unfamiliar areas, in wet conditions, and at night or dusk. The majority of participants rated their own driving as good to excellent. Of the 47 (17%) of drivers who were rated as potentially unsafe to drive, 66% rated their own driving as good to excellent. Drivers who made critical errors, where the driving instructor had to take control of the vehicle, had no lower self-rating of driving ability then the rest of the group. The discrepancy in self-perceptions of driving and participants’ safety rating on the on-road assessment was significantly associated with self-reported retrospective crash rates, where those drivers who displayed greater overconfidence in their own driving were significantly more likely to report a crash. Conclusions This study demonstrates that older drivers with the greatest mismatch between actual and self-rated driving ability pose the greatest risk to road safety. Therefore licensing authorities should not assume that when older individuals’ driving abilities begin to decline they will necessarily be aware of these changes and adopt appropriate compensatory driving behaviours; rather, it is essential that evidence-based assessments are adopted.
Resumo:
The aim of this study was to investigate the effect of court surface (clay v hard-court) on technical, physiological and perceptual responses to on-court training. Four high-performance junior male players performed two identical training sessions on hard and clay courts, respectively. Sessions included both physical conditioning and technical elements as led by the coach. Each session was filmed for later notational analysis of stroke count and error rates. Further, players wore a global positioning satellite device to measure distance covered during each session; whilst heart rate, countermovement jump distance and capillary blood measures of metabolites were measured before, during and following each session. Additionally a respective coach and athlete rating of perceived exertion (RPE) were measured following each session. Total duration and distance covered during of each session were comparable (P>0.05; d<0.20). While forehand and backhands stroke volume did not differ between sessions (P>0.05; d<0.30); large effects for increased unforced and forced errors were present on the hard court (P>0.05; d>0.90). Furthermore, large effects for increased heart rate, blood lactate and RPE values were evident on clay compared to hard courts (P>0.05; d>0.90). Additionally, while player and coach RPE on hard courts were similar, there were large effects for coaches to underrate the RPE of players on clay courts (P>0.05; d>0.90). In conclusion, training on clay courts results in trends for increased heart rate, lactate and RPE values, suggesting sessions on clay tend towards higher physiological and perceptual loads than hard courts. Further, coaches appear effective at rating player RPE on hard courts, but may underrate the perceived exertion of sessions on clay courts.
Resumo:
Series reactors are used in distribution grids to reduce the short-circuit fault level. Some of the disadvantages of the application of these devices are the voltage drop produced across the reactor and the steep front rise of the transient recovery voltage (TRV), which generally exceeds the rating of the associated circuit breaker. Simulations were performed to compare the characteristics of a saturated core High-Temperature Superconducting Fault Current Limiter (HTS FCL) and a series reactor. The design of the HTS FCL was optimized using the evolutionary algorithm. The resulting Pareto frontier curve of optimum solution is presented in this paper. The results show that the steady-state impedance of an HTS FCL is significantly lower than that of a series reactor for the same level of fault current limiting. Tests performed on a prototype 11 kV HTS FCL confirm the theoretical results. The respective transient recovery voltages (TRV) of the HTS FCL and an air core reactor of comparable fault current limiting capability are also determined. The results show that the saturated core HTS FCL has a significantly lower effect on the rate of rise of the circuit breaker TRV as compared to the air core reactor. The simulations results are validated with shortcircuit test results.
Resumo:
This study examined the effects of personal and social resources, coping strategies and appraised stress on employees' levels of anxiety and depression. In relation to the effects of resources and coping strategies, two different models were tested. The main effects model proposes that, irrespective of the level of stress, coping resources and coping strategies have direct effects on well-being. In contrast, the buffering model predicts that the buffering effects of coping resources and strategies are only evident at high levels of stress. One hundred lawyers completed a structured self-administered questionnaire that measured their personal and social resources, use of problem-focused and emotion-focused coping strategies, and appraisals of the stressfulness of the situation. Results revealed generally strong support for the main effects model in the prediction of employee levels of anxiety and depression. Lower levels of anxiety were linked to judgements of lower levels of organizational change, greater self-confidence, greater internality of control beliefs and less use of emotion-focused coping strategies. Lower levels of depression in employees were also linked to judgements of lower levels of organizational change, greater use of resources and less appraised stress. There was only limited support for the buffering effects model. Due to the small size of the sample, the findings need to be explored further in other contexts.
Resumo:
A global, online quantitative study among 300 consumers of digital technology products found the most reliable information sources were friends, family or word of mouth (WOM) from someone they knew, followed by expert product reviews, and product reviews written by other consumers. The most unreliable information sources were advertising or infomercials, automated recommendations based on purchasing patterns or retailers. While a very small number of consumers evaluated products online, rating of products and online discussions were more frequent activities. The most popular social media websites for reviews were Facebook, Twitter, Amazon and e-Bay, indicating the importance of WOM in social networks and online media spaces that feature product reviews as it is the most persuasive piece of information in both online and offline social networks. These results suggest that ‘social customers’ must be considered as an integral part of a marketing strategy.
Resumo:
In order to develop more inclusive products and services, designers need a means of assessing the inclusivity of existing products and new concepts. Following previous research on the development of scales for inclusive design at University of Cambridge, Engineering Design Centre (EDC) [1], this paper presents the latest version of the exclusion audit method. For a specific product interaction, this estimates the proportion of the Great British population who would be excluded from using a product or service, due to the demands the product places on key user capabilities. A critical part of the method involves rating of the level of demand placed by a task on a range of key user capabilities, so the procedure to perform this assessment was operationalised and then its reliability was tested with 31 participants. There was no evidence that participants rated the same demands consistently. The qualitative results from the experiment suggest that the consistency of participants’ demand level ratings could be significantly improved if the audit materials and their instructions better guided the participant through the judgement process.
Resumo:
An ironless motor for use as direct wheel drive is presented. The motor is intended for use in a lightweight (600kg), low drag, series hybrid commuter vehicle under development at The University of Queensland. The vehicle will utilise these ironless motors in each of its rear wheels, with each motor producing a peak torque output of 500Nm and a maximum rotational speed of 1500rpm. The axial flux motor consists of twin Ironless litz wire stators with a central magnetic ring and simplified Halbach magnet arrays on either side. A small amount of iron is used to support the outer Halbach arrays and to improve the peak magnetic flux density. Ducted air cooling is used to remove heat from the motor and will allow for a continuous torque rating of 250Nm. Ironless machines have previously been shown to be effective in high speed, high frequency applications (+1000Hz). They are generally regarded as non-optimal for low speed applications as iron cores allow for better magnet utilisation and do not significantly increase the weight of a machine. However, ironless machines can also be seen to be effective in applications where the average torque requirement is much lower than the peak torque requirement such as in some vehicle drive applications. The low spinning losses in ironless machines are shown to result in very high energy throughput efficiency in a wide range of vehicle driving cycles.
Resumo:
Voltage unbalance is a major power quality problem in low voltage residential feeders due to the random location and rating of single-phase rooftop photovoltaic cells (PV). In this paper, two different improvement methods based on the application of series (DVR) and parallel (DSTATCOM) custom power devices are investigated to improve the voltage unbalance problem in these feeders. First, based on the load flow analysis carried out in MATLAB, the effectiveness of these two custom power devices is studied vis-à-vis the voltage unbalance reduction in urban and semi-urban/rural feeders containing rooftop PVs. Their effectiveness is studied from the installation location and rating points of view. Later, a Monte Carlo based stochastic analysis is carried out to investigate their efficacy for different uncertainties of load and PV rating and location in the network. After the numerical analyses, a converter topology and control algorithm is proposed for the DSTATCOM and DVR for balancing the network voltage at their point of common coupling. A state feedback control, based on pole-shift technique, is developed to regulate the voltage in the output of the DSTATCOM and DVR converters such that the voltage balancing is achieved in the network. The dynamic feasibility of voltage unbalance and profile improvement in LV feeders, by the proposed structure and control algorithm for the DSTATCOM and DVR, is verified through detailed PSCAD/EMTDC simulations.
Resumo:
The emerging growth of Web 2.0 has been observed by users in the workplace, and has therefore encouraged organisations to introduce Web 2.0 technologies in their businesses. Although its adoption is beneficial, it could meets with employees resistance due to some organisational factors. The successful implementation of Enterprise Web 2.0 is based on employee adoption of such social technology. Using a qualitative study, this research explores how organizational support can influence employees’ adoption of Enterprise Web 2.0. The findings show that organisational support encourages and facilitates a smooth adoption. Such support can be provided by management and colleagues in several forms: developing a Web 2.0 strategy, providing required resources for such training, recognising and encouraging adopters, and involving managers in the adoption.
Resumo:
Background: The concept of palliative care consisting of five distinct, clinically meaningful, phases (stable, unstable, deteriorating, terminal and bereavement) was developed in Australia about 20 years ago and is used routinely for communicating clinical status, care planning, quality improvement and funding. Aim: To test the reliability and acceptability of revised definitions of Palliative Care Phase. Design: Multi-centre cross-sectional study involving pairs of clinicians independently rating patients according to revised definitions of Palliative Care Phase. Setting/participants: Clinicians from 10 Australian palliative care services, including 9 inpatient units and 1 mixed inpatient/community-based service. Results: A total of 102 nursing and medical clinicians participated, undertaking 595 paired assessments of 410 patients, of which 90.7% occurred within 2 h. Clinicians rated 54.8% of patients in the stable phase, 15.8% in the unstable phase, 20.8% in the deteriorating phase and 8.7% in the terminal phase. Overall agreement between clinicians’ rating of Palliative Care Phase was substantial (kappa = 0.67; 95% confidence interval = 0.61–0.70). A moderate level of inter-rater reliability was apparent across all participating sites. The results indicated that Palliative Care Phase was an acceptable measure, with no significant difficulties assigning patients to a Palliative Care Phase and a good fit between assessment of phase and the definition of that phase. The most difficult phase to distinguish from other phases was the deteriorating phase. Conclusion: Policy makers, funders and clinicians can be confident that Palliative Care Phase is a reliable and acceptable measure that can be used for care planning, quality improvement and funding purposes.
Resumo:
The heavy haul rail network in Queensland Australia generally adopts a lightning impulse withstand voltage rating of 250 kV for the switchgear and autotransformers within its 50 kV ac traction feeder stations. The aging switchgear across a number of feeder stations in this network are undergoing upgrade and the rail network operator is considering the possibility of using 200 kV rating for the upgraded switchgear. This paper investigates the lightning over-voltages that could occur at the feeder stations under review. Fast front transient models of the feeder stations and the associated traction corridors are developed in PSCAD/EMTDC software. Simulations are conducted to evaluate the likely over-voltages under various scenarios and the results are presented. Finally, the required lightning impulse withstand voltage rating for the switchgear is determined based on the simulation results.