427 resultados para ENERGY-EXPENDITURE


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Access to dietetic care is important in chronic disease management and innovative technologies assists in this purpose. Photographic dietary records (PhDR) using mobile phones or cameras are valid and convenient for patients. Innovations in providing dietary interventions via telephone and computer can also inform dietetic practice. Three studies are presented. A mobile phone method was validated by comparing energy intake (EI) to a weighed food record and a measure of energy expenditure (EE) obtained using the doubly labelled water technique in 10 adults with T2 diabetes. The level of agreement between mean (±sd) energy intake mobile phone (8.2±1.7 MJ) and weighed record (8.5±1.6 MJ) was high (p=0.392), however EI/EE for both methods gave similar levels of under-reporting (0.69 and 0.72). All subjects preferred using the mobile phone vs. weighed record. Nineteen individuals with Parkinsons disease kept 3-day PhDRs on three occasions using point-and-shoot digital cameras over a 12 week period. The camera was rated as easy to use by 89%, keeping a PhDR was considered acceptable by 94% and none would rather use a “pen and paper” method. Eighty-three percent felt confident to use the camera again to record intake. An interactive, automated telephone system designed to coach people with T2 diabetes to adopt and maintain diabetes self-care behaviours, including nutrition, showed trends for improvements in total fat, saturated fat and vegetable intake of the intervention group compared to control participants over 6 months. Innovative technologies are acceptable to patients with chronic conditions and can be incorporated into dietetic care.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes a novel optimum path planning strategy for long duration AUV operations in environments with time-varying ocean currents. These currents can exceed the maximum achievable speed of the AUV, as well as temporally expose obstacles. In contrast to most other path planning strategies, paths have to be defined in time as well as space. The solution described here exploits ocean currents to achieve mission goals with minimal energy expenditure, or a tradeoff between mission time and required energy. The proposed algorithm uses a parallel swarm search as a means to reduce the susceptibility to large local minima on the complex cost surface. The performance of the optimisation algorithms is evaluated in simulation and experimentally with the Starbug AUV using a validated ocean model of Brisbane’s Moreton Bay.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose The purpose of this review is to address important methodological issues related to conducting accelerometer-based assessments of physical activity in free-living individuals. Methods We review the extant scientific literature for empirical information related to the following issues: product selection, number of accelerometers needed, placement of accelerometers, epoch length, and days of monitoring required to estimate habitual physical activity. We also discuss the various options related to distributing and collecting monitors and strategies to enhance compliance with the monitoring protocol. Results No definitive evidence exists currently to indicate that one make and model of accelerometer is more valid and reliable than another. Selection of accelerometer therefore remains primarily an issue of practicality, technical support, and comparability with other studies. Studies employing multiple accelerometers to estimate energy expenditure report only marginal improvements in explanatory power. Accelerometers are best placed on hip or the lower back. Although the issue of epoch length has not been studied in adults, the use of count cut points based on 1-min time intervals maybe inappropriate in children and may result in underestimation of physical activity. Among adults, 3–5 d of monitoring is required to reliably estimate habitual physical activity. Among children and adolescents, the number of monitoring days required ranges from 4 to 9 d, making it difficult to draw a definitive conclusion for this population. Face-to-face distribution and collection of accelerometers is probably the best option in field-based research, but delivery and return by express carrier or registered mail is a viable option. Conclusion Accelerometer-based activity assessments requires careful planning and the use of appropriate strategies to increase compliance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With measurement of physical activity becoming more common in clinical practice, it is imperative that healthcare professionals become more knowledgeable about the different methods available to objectively measure physical activity behaviour. Objective measures do not rely on information provided by the patient, but instead measure and record the biomechanical or physiological consequences of performing physical activity, often in real time. As such, objective measures are not subject to the reporting bias or recall problems associated with self-report methods. The purpose of this article was to provide an overview of the different methods used to objectively measure physical activity in clinical practice. The review was delimited to heart rate monitoring, accelerometers and pedometers since their small size, low participant burden and relatively low cost make these objective measures appropriate for use in clinical practice settings. For each measure, strengths and weakness were discussed; and whenever possible, literature-based examples of implementation were provided.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To compare the classification accuracy of previously published RT3 accelerometer cut-points for youth using energy expenditure, measured via portable indirect calorimetry, as a criterion measure. DESIGN: Cross-sectional cross-validation study. METHODS: 100 children (mean age 11.2±2.8 years, 61% male) completed 12 standardized activities trials (3 sedentary, 5 lifestyle and 4 ambulatory) while wearing an RT3 accelerometer. V˙O2 was measured concurrently using the Oxycon Mobile portable calorimeter. Cut-points by Vanhelst (VH), Rowlands (RW), Chu (CH), Kavouras (KV) and the RT3 manufacturer (RT3M) were used to classify PA intensity as sedentary (SED), light (LPA), moderate (MPA) or vigorous (VPA). Classification accuracy was evaluated using the area under the Receiver Operating Characteristic curve (ROC-AUC) and weighted Kappa (κ). RESULTS: For moderate-to-vigorous PA (MVPA), VH, KV and RW exhibited excellent accuracy classification (ROC-AUC≥0.90), while the CH and RT3M exhibited good classification accuracy (ROC-AUC>0.80). Classification accuracy for LPA was fair to poor (ROC-AUC<0.76). For SED, VH exhibited excellent classification accuracy (ROC-AUC>0.90), while RW, CH, and RT3M exhibited good classification accuracy (ROC-AUC>0.80). Kappa statistics ranged from 0.67 (VH) to 0.55 (CH). CONCLUSIONS: All cut-points provided acceptable classification accuracy for SED and MVPA, but limited accuracy for LPA. On the basis of classification accuracy over all four levels of intensity, the use of the VH cut-points is recommended.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Accelerometers have become one of the most common methods of measuring physical activity (PA). Thus, validity of accelerometer data reduction approaches remains an important research area. Yet, few studies directly compare data reduction approaches and other PA measures in free-living samples. Objective To compare PA estimates provided by 3 accelerometer data reduction approaches, steps, and 2 self-reported estimates: Crouter's 2-regression model, Crouter's refined 2-regression model, the weighted cut-point method adopted in the National Health and Nutrition Examination Survey (NHANES; 2003-2004 and 2005-2006 cycles), steps, IPAQ, and 7-day PA recall. Methods A worksite sample (N = 87) completed online-surveys and wore ActiGraph GT1M accelerometers and pedometers (SW-200) during waking hours for 7 consecutive days. Daily time spent in sedentary, light, moderate, and vigorous intensity activity and percentage of participants meeting PA recommendations were calculated and compared. Results Crouter's 2-regression (161.8 +/- 52.3 minutes/day) and refined 2-regression (137.6 +/- 40.3 minutes/day) models provided significantly higher estimates of moderate and vigorous PA and proportions of those meeting PA recommendations (91% and 92%, respectively) as compared with the NHANES weighted cut-point method (39.5 +/- 20.2 minutes/day, 18%). Differences between other measures were also significant. Conclusions When comparing 3 accelerometer cut-point methods, steps, and self-report measures, estimates of PA participation vary substantially.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background Wearable monitors are increasingly being used to objectively monitor physical activity in research studies within the field of exercise science. Calibration and validation of these devices are vital to obtaining accurate data. This article is aimed primarily at the physical activity measurement specialist, although the end user who is conducting studies with these devices also may benefit from knowing about this topic. Best Practices Initially, wearable physical activity monitors should undergo unit calibration to ensure interinstrument reliability. The next step is to simultaneously collect both raw signal data (e.g., acceleration) from the wearable monitors and rates of energy expenditure, so that algorithms can be developed to convert the direct signals into energy expenditure. This process should use multiple wearable monitors and a large and diverse subject group and should include a wide range of physical activities commonly performed in daily life (from sedentary to vigorous). Future Directions New methods of calibration now use "pattern recognition" approaches to train the algorithms on various activities, and they provide estimates of energy expenditure that are much better than those previously available with the single-regression approach. Once a method of predicting energy expenditure has been established, the next step is to examine its predictive accuracy by cross-validating it in other populations. In this article, we attempt to summarize the best practices for calibration and validation of wearable physical activity monitors. Finally, we conclude with some ideas for future research ideas that will move the field of physical activity measurement forward.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose Most studies that use either a single exercise session, exercise training, or a cross-sectional design have failed to find a relationship between exercise and plasma lipoprotein(a) [Lp(a)] concentrations. However, a few studies investigating the effects of longer and/or more strenuous exercise have shown elevated Lp(a) concentrations, possibly as an acute-phase reactant to muscle damage. Based on the assumption that greater muscle damage would occur with exercise of longer duration, the purpose of the present study was to determine whether exercise of longer duration would increase Lp(a) concentration and creatine kinase. (CK) activity more than exercise of shorter duration. Methods Ten endurance-trained men (mean +/- SD: age, 27 +/- 6 yr; maximal oxygen consumption [(V)over dotO(2max)], 57 +/- 7 mL(.)kg(-1) min(-1)) completed two separate exercise sessions at 70% (V)over dotO(2max). One session required 900 kcal of energy expenditure (60 +/- 6 min), and the other required 1500 kcal (112 +/- 12 min). Fasted blood samples were taken immediately before (0-pre), immediately after (0-post), 1 d after (1-post), and 2 d after (2-post) each exercise session. Results CK activity increased after both exercise sessions (mean +/- SE; 800 kcal: 0-pre 55 +/- 11, 1-post 168 +/- 64 U(.)L(-1.)min(-1); 1500 kcal: 0-pre 51 +/- 5, 1-post 187 +/- 30, 2-post 123 +/- 19 U(.)L(-1.)min(-1); P < 0.05). However, median Lp(a) concentrations were not altered by either exercise session (800 kcal: 0-pre 5.0 mg(.)dL(-1), 0-post 3.2 mg(.)dL(-1), 1-post 4.0 mg(.)dL(-1), 2-post 3.4 mg(.)dL(-1); 1500 kcal: 0-pre 5.8 mg(.)dL(-1), 0-post 4.3 mg(.)dL(-1), 1-post 3.2 mg(.)dL(-1), 2-post 5.3 mg(.)dL(-1)). In addition, no relationship existed between exercise-induced changes in CK activity and Lp(a) concentration (800 kcal: r = -0.26; 1500 kcal: r = -0.02). Conclusion These results suggest that plasma Lp(a) concentration will not increase in response to minor exercise-induced muscle damage in endurance-trained runners.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The absence of comparative validity studies has prevented researchers from reaching consensus regarding the application of intensity-related accelerometer cut points for children and adolescents. PURPOSE This study aimed to evaluate the classification accuracy of five sets of independently developed ActiGraph cut points using energy expenditure, measured by indirect calorimetry, as a criterion reference standard. METHODS A total of 206 participants between the ages of 5 and 15 yr completed 12 standardized activity trials. Trials consisted of sedentary activities (lying down, writing, computer game), lifestyle activities (sweeping, laundry, throw and catch, aerobics, basketball), and ambulatory activities (comfortable walk, brisk walk, brisk treadmill walk, running). During each trial, participants wore an ActiGraph GT1M, and VO 2 was measured breath-by-breath using the Oxycon Mobile portable metabolic system. Physical activity intensity was estimated using five independently developed cut points: Freedson/Trost (FT), Puyau (PU), Treuth (TR), Mattocks (MT), and Evenson (EV). Classification accuracy was evaluated via weighted κ statistics and area under the receiver operating characteristic curve (ROC-AUC). RESULTS Across all four intensity levels, the EV (κ = 0.68) and FT (κ = 0.66) cut points exhibited significantly better agreement than TR (κ = 0.62), MT (κ = 0.54), and PU (κ = 0.36). The EV and FT cut points exhibited significantly better classification accuracy for moderate-to vigorous-intensity physical activity (ROC-AUC = 0.90) than TR, PU, or MT cut points (ROC-AUC = 0.77-0.85). Only the EV cut points provided acceptable classification accuracy for all four levels of physical activity intensity and performed well among children of all ages. The widely applied sedentary cut point of 100 counts per minute exhibited excellent classification accuracy (ROC-AUC = 0.90). CONCLUSIONS On the basis of these findings, we recommend that researchers use the EV ActiGraph cut points to estimate time spent in sedentary, light-, moderate-, and vigorous-intensity activity in children and adolescents. Copyright © 2011 by the American College of Sports Medicine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose The purpose of this study was to evaluate the validity of the CSA activity monitor as a measure of children's physical activity using energy expenditure (EE) as a criterion measure. Methods Thirty subjects aged 10 to 14 performed three 5-min treadmill bouts at 3, 4, and 6 mph, respectively. While on the treadmill, subjects wore CSA (WAM 7164) activity monitors on the right and left hips. (V) over dot O-2 was monitored continuously by an automated system. EE was determined by multiplying the average (V) over dot O-2 by the caloric equivalent of the mean respiratory exchange ratio. Results Repeated measures ANOVA indicated that both CSA monitors were sensitive to changes in treadmill speed. Mean activity counts from each CSA unit were not significantly different and the intraclass reliability coefficient for the two CSA units across all speeds was 0.87. Activity counts from both CSA units were strongly correlated with EE (r = 0.86 and 0.87, P < 0.001). An EE prediction equation was developed from 20 randomly selected subjects and cross-validated on the remaining 10. The equation predicted mean EE within 0.01 kcal.min(-1). The correlation between actual and predicted values was 0.93 (P < 0.01) and the SEE was 0.93 kcal.min(-1). Conclusion These data indicate that the CSA monitor is a valid and reliable tool for quantifying treadmill walking and running in children.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to effectively measure the physical activity of children, objective monitoring devices must be able to quantify the intermittent and nonlinear movement of free play. The purpose of this study was to investigate the validity of the Computer Science and Applications (CSA) uniaxial accelerometer and the TriTrac-R3D triaxial accelerometer with respect to their ability to measure 8 "free-play" activities of different intensity. The activities ranged from light to very vigorous in intensity and included activities such as throwing and catching, hopscotch, and basketball. Twenty-eight children, ages 9 to 11, wore a CSA and a heart rate monitor while performing the activities. Sixteen children also wore a Tritrac. Counts from the CSA, Tritrac, and heart rates corresponding to the last 3 min of the 5 min spent at each activity were averaged and used in correlation analyses. Across all 8 activities, Tritrac counts were significantly correlated with predicted MET level (r= 0.69) and heart rate (r= 0.73). Correlations between CSA output, predicted MET level (0.43), and heart rate (0.64) were also significant but were lower than those observed for the Tritrac. These data indicate that accelerometers are an appropriate methodology for measuring children's free-play physical activities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study examined the tracking of selected measures of physical activity, inactivity, and fitness in a cohort of rural youth. Students (N = 181, 54.7% female, 63.5% African American) completed test batteries during their fifth-(age = 10.7 +/- 0.7 years), sixth-, and seventh-grade years. The Previous Day Physical Activity Recall (PDPAR) was used to assess 30-min blocks of vigorous physical activity (VPA), moderate-to-vigorous physical activity (MVPA), TV watching and other sedentary activities, and estimated energy expenditure (EE). Fitness measures included the PWC 170 cycle ergometer test, strength tests, triceps skinfold thickness, and BMI. Intraclass correlation coefficients (ICCs) for VPA, MVPA, and after-school EE ranged from 0.63 to 0.78. ICCs ranged from 0.49 to 0.71 for measures of inactivity and from 0.78 to 0.82 for the fitness measures. These results indicate that measures of physical activity, inactivity, and physical fitness tend to track during the transition from elementary to middle school.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The unique physical and movement characteristics of children necessitate the development of accelerometer equations and cut points that are population specific. The purpose of this study is to develop an ecologically valid cut point for the Biotrainer Pro monitor that reflects a threshold for moderate-intensity physical activity in elementary school children. A sample of 30 children (ages 8-12) wore a Biotrainer monitor while completing a series of 7 movement tasks (calibration phase) and while participating in an organized group activity (cross-validation phase). Videotapes from each session were processed using a computerized direct-observation technique to provide a criterion measure of physical activity. Analyses involved the use of mixed-model regression and receiver operator characteristic (ROC) curves. The results indicated that a cut point of 4 counts/min provides the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of activity as inactivity). Results with the cross-validation data demonstrated that this value yielded the best overall kappa (.58) and a high classification agreement (84%) for activity determination. The specificity of 93% demonstrates that the proposed cut point can accurately detect activity; however, the lower sensitivity value of 61% suggests that some minutes of activity might be incorrectly classified as inactivity. The cut point of 4 counts/min provides an ecologically valid cut point to capture physical activity in children using the Biotrainer Pro activity monitor.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To date, a wide range of methods has been used to measure physical activity in children and adolescents. These include self-report methods such as questionnaires, activity logs, and diaries as well as objective measures of physical activity such as direct observation, doubly labeled water, heart rate monitoring, accelerometers, and pedometers. The purpose of this review is to overview the methods currently being used to measure physical activity in children and adolescents. For each measurement approach, new developments and/or innovations are identified and discussed. Particular attention is given to the use of accelerometers and the calibration of accelerometer output to units of energy expenditure to developing children.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To evaluate the validity of the ActiGraph accelerometer for the measurement of physical activity intensity in children and adolescents with cerebral palsy (CP) using oxygen uptake (VO 2) as the criterion measure. Thirty children and adolescents with CP (mean age 12.6 ± 2.0 years) wore an ActiGraph 7164 and a Cosmed K4b 2 portable indirect calorimeter during four activities; quiet sitting, comfortable paced walking, brisk paced walking and fast paced walking. VO 2 was converted to METs and activity energy expenditure and classiWed as sedentary, light or moderate-to-vigorous intensity according to the conventions for children. Mean ActiGraph counts min -1 were classiWed as sedentary, light or moderate-to-vigorous (MVPA) intensity using four diVerent sets of cut-points. VO 2 and counts min¡1 increased signiWcantly with increases in walking speed (P < 0.001). Receiver operating characteristic (ROC) curve analysis indicated that, of the four sets of cut-points evaluated, the Evenson et al. (J Sports Sci 26(14):1557-1565, 2008) cut-points had the highest classiWcation accuracy for sedentary (92%) and MVPA (91%), as well as the second highest classiWcation accuracy for light intensity physical activity (67%). A ROC curve analysis of data from our participants yielded a CP-speciWc cut-point for MVPA that was lower than the Evenson cut-point (2,012 vs. 2,296 counts min¡1), however, the diVerence in classiWcation accuracy was not statistically signiWcant 94% (95% CI = 88.2-97.7%) vs. 91% (95% CI = 83.5-96.5%). In conclusion, among children and adolescents with CP, the ActiGraph is able to diVerentiate between diVerent intensities of walking. The use of the Evenson cut-points will permit the estimation of time spent in MVPA and allows comparisons to be made between activity measured in typically developing adolescents and adolescents with CP. © 2011 Springer-Verlag.