190 resultados para Anterior Cingulate


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endoscopic approaches for anterior correction of idiopathic scoliosis are a relatively new surgical technique. This paper describes the development of patient-specific finite element modelling techniques to investigate the biomechanics of single rod anterior scoliosis correction. Spinal geometry is obtained from pre-operative CT scans and material properties for osteo-ligamentous spinal tissues are based on existing literature. The techniques being developed will allow pre-surgical prediction of stresses, forces and deformations in spinal tissues, rods and screws under post-operative physiological loads.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rigid lenses have been fitted less since the introduction of soft lenses nearly 40 years ago. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA between 2000 and 2008 facilitate an accurate characterization of the pattern of the decline of rigid lens fitting during the first decade of this century. There is a trend for rigid lenses to be utilized primarily for refitting those patients who are already successful rigid lens wearers—most typically older females being refit with higher Dk materials. Rigid lenses are generally fitted on a full-time basis (four or more days of wear per week) without a planned replacement schedule. Orthokeratology is especially popular in the Netherlands, but is seldom prescribed in the other countries surveyed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Extended wear has long been the ‘holy grail’ of contact lenses by virtue of the increased convenience and freedom of lifestyle which they accord; however, this modality enjoyed only limited market success during the last quarter of the 20th century. The introduction of silicone hydrogel materials into the market at the beginning of this century heralded the promise of successful extended wear due to the superior oxygen performance of this lens type. To assess patterns of contact lens fitting, including extended wear, over the past decade, up to 1000 survey forms were sent to contact lens fitters in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA each year between 2000 and 2009. Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Analysis of returned forms revealed that, averaged over this period, 9% of all soft lenses prescribed were for extended wear, with national figures ranging from 2% in Japan to 17% in Norway. The trend over the past decade has been for an increase from about 5% of all soft lens fits in 2000 to a peak of between 9 and 12% between 2002 and 2007, followed by a decline to around 7% in 2009. A person receiving extended wear lenses is likely to be an older female who is being refitted with silicone hydrogel lenses for full-time wear. Although extended wear has yet again failed to fulfil the promise of being the dominant contact lens wearing modality, it is still a viable option for many people.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Silicone hydrogel contact lenses were introduced into the market in 1999. To assess prescribing trends of this lens type since then, up to 1000 survey forms were sent to contact lens fitters in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA each year between 2000 and 2008. Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Analysis of returned forms revealed a rapid increase in the prescribing of silicone hydrogel lenses over the survey period. In 2008, silicone hydrogel lenses represented 36% of all soft lenses prescribed. The categorization of the majority of lenses prescribed as ‘refits’ is primarily attributed to the mass conversion of lens wearers from hydrogel to silicone hydrogel lenses. Silicone hydrogels may soon represent the majority of soft contact lenses prescribed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Daily disposable contact lenses were introduced into the market 16 years ago. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, The Netherlands, Norway, the UK and the USA between 2000 and 2008 indicates an overall increase in daily disposable lens fitting during this period. Daily disposable lenses are especially popular in Japan, Norway and the UK. There is a trend for these lenses to be fitted on a part-time basis. Males are over-represented in daily disposable lens fitting—a trend that is especially evident in Canada. Daily disposable lens wearers are about two years younger than wearers of reusable lenses in Japan and The Netherlands. The convenience and health benefits of daily disposable lenses are expected to fuel continued growth in this sector.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Knowledge of differences in the demographics of contact lens prescribing between nations, and changes over time, can assist (a) the contact lens industry in developing and promoting various product types in different world regions, and (b) practitioners in understanding their prescribing habits in an international context. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA between 2000 and 2008 reveal an ageing demographic, with Japan being the most youthful. The majority of fits are to females, with statistically significant differences between nations, ranging from 62 per cent of fits in Norway to 68 per cent in Japan. The small overall decline in the proportion of new fits, and commensurate increase in refits, over the survey periodmay indicate a growing rate of conversion of lens wearers to more advanced lens types, such as silicone hydrogels. � 2009 British Contact Lens Association.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the influence of accommodation upon axial length (and a comprehensive range of ocular biometric parameters), in populations of young adult myopic and emmetropic subjects. Methods: Forty young adult subjects had ocular biometry measured utilizing a non-contact optical biometer (Lenstar LS 900) based upon the principle of optical low coherence reflectometry, under three different accommodation demands (0 D, 3 D and 6 D). Subjects were classified as emmetropes (n=19) or myopes (n=21) based upon their spherical equivalent refraction (mean emmetropic refraction -0.05 ± 0.27DS and mean myopic refraction -1.82 ± 0.84 DS). Results: Axial length changed significantly with accommodation, with a mean increase of 11.9 ± 12.3 µm and 24.1 ± 22.7 µm for the 3 D and 6 D accommodation stimuli respectively. A significant axial elongation associated with accommodation was still evident even following correction of the axial length data for potential error due to lens thickness change. The mean ‘corrected’ increase in axial length was 5.2 ± 11.2 µm, and 7.4 ± 18.9 µm for the 3 D and 6 D stimuli respectively. There was no significant difference between the myopic and emmetropic populations in terms of the magnitude of change in axial length with accommodation, regardless of whether the data were corrected or not. A number of other ocular biometric parameters, such as anterior chamber depth, lens thickness and vitreous chamber depth also exhibited significant change with accommodation. The myopic and emmetropic populations also exhibited no significant difference in the magnitude of change in these parameters with accommodation. Conclusions: The eye undergoes a significant axial elongation associated with a brief period of accommodation, and the magnitude of this change in eye length increases for larger accommodation demands, however there is no significant difference in the magnitude of eye elongation in myopic and emmetropic subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the short term influence of imposed monocular defocus upon human optical axial length (the distance from anterior cornea to retinal pigment epithelium) and ocular biometrics. Methods: Twenty-eight young adult subjects (14 myopes and 14 emmetropes) had eye biometrics measured before and then 30 and 60 minutes after exposure to monocular (right eye) defocus. Four different monocular defocus conditions were tested, each on a separate day: control (no defocus), myopic (+3 D defocus), hyperopic (-3 D defocus) and diffuse (0.2 density Bangerter filter) defocus. The fellow eye was optimally corrected (no defocus). Results: Imposed defocus caused small but significant changes in optical axial length (p<0.0001). A significant increase in optical axial length (mean change +8 ± 14 μm, p=0.03) occurred following hyperopic defocus, and a significant reduction in optical axial length (mean change -13 ± 14 μm, p=0.0001) was found following myopic defocus. A small increase in optical axial length was observed following diffuse defocus (mean change +6 ± 13 μm, p=0.053). Choroidal thickness also exhibited some significant changes with certain defocus conditions. No significant difference was found between myopes and emmetropes in the changes in optical axial length or choroidal thickness with defocus. Conclusions: Significant changes in optical axial length occur in human subjects following 60 minutes of monocular defocus. The bi-directional optical axial length changes observed in response to defocus implies the human visual system is capable of detecting the presence and sign of defocus and altering optical axial length to move the retina towards the image plane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the influence of soft contact lenses on regional variations in corneal thickness and shape while taking account of natural diurnal variations in these corneal parameters. Methods: Twelve young, healthy subjects wore 4 different types of soft contact lenses on 4 different days. The lenses were of two different materials (silicone hydrogel, hydrogel), designs (spherical, toric) and powers (–3.00, –7.00 D). Corneal thickness and topography measurements were taken before and after 8 hours of lens wear and on two days without lens wear, using the Pentacam HR system. Results: The hydrogel toric contact lens caused the greatest level of corneal thickening in the central (20.3 ± 10.0 microns) as well as peripheral cornea (24.1 ± 9.1 microns) (p < 0.001) with an obvious regional swelling of the cornea beneath the stabilizing zones. The anterior corneal surface generally showed slight flattening. All contact lenses resulted in central posterior corneal steepening and this was weakly correlated with central corneal swelling (p = 0.03) and peripheral corneal swelling (p = 0.01). Conclusions: There was an obvious regional corneal swelling apparent after wear of the hydrogel soft toric lenses, due to the location of the thicker stabilization zones of the toric lenses. However with the exception of the hydrogel toric lens, the magnitude of corneal swelling induced by the contact lenses over the 8 hours of wear was less than the natural diurnal thinning of the cornea over this same period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prospective clinical case series of 100 patients receiving thoracoscopic anterior scoliosis correction surgery. The objective was to evaluate the relationship between clinical outcomes of thoracoscopic anterior scoliosis surgery and deformity correction using the Scoliosis Research Society (SRS) outcomes instrument questionnaire. The surgical treatment of scoliosis is quantitatively assessed in the clinic using radiographic measures of deformity correction, as well as the rib hump, but it is important to understand the extent to which these quantitative measures correlate with self-reported improvements in patients’ quality of life following surgery. A series of 100 consecutive adolescent idiopathic scoliosis patients received a single anterior rod via a thoracoscopic approach at the Mater Children’s Hospital, Brisbane, Australia. Patients completed SRS outcomes questionnaires pre-operatively and at 24 months post-operatively. There were 94 females and 6 males with a mean age of 16.1 years. The mean Cobb angle improved from 52º pre-operatively to 25º post-operatively (52%) and the mean rib hump improved from 16º to 8º (51%). The mean total SRS score for the cohort was 99.4/120. None of the deformity related parameters in the multiple regression were significant. However, patients with the lowest post-operative major Cobb angles reported significantly higher SRS scores than those with the highest post-operative Cobb angles, but there was no difference on the basis of rib hump correction. There were no significant differences between patients with either rod fractures or screw-related complications compared to those without complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thoroughly revised and updated, this popular book provides a comprehensive yet easy to read guide to modern contact lens practice. Beautifully re-designed in a clean, contemporary layout, this second edition presents relevant and up-to-date information in a systematic manner, with a logical flow of subject matter from front to back. This book wonderfully captures the ‘middle ground’ in the contact lens field … somewhere between a dense research-based tome and a basic fitting guide. As such, it is ideally suited for both students and general eye care practitioners who require a practical, accessible and uncluttered account of the contact lens field. Contents Part 1 Introduction Historical perspective. The anterior eye Visual optics Clinical instruments Part 2 Soft contact lenses Soft lens materials Soft lens manufacture Soft lens optics Soft lens measurement Soft lens design and fitting Soft toric lens design and fitting Soft lens care systems Part 3 Rigid contact lenses Rigid lens materials Rigid lens manufacture Rigid lens optics Rigid lens measurement Rigid lens design and fitting Rigid toric lens design and fitting Rigid lens care systems Part 4 Lens replacement modalities Unplanned lens replacement Daily soft lens replacement Planned soft lens replacement Planned rigid lens replacement Part 5 Special lenses and fitting considerations Scleral lenses Tinted lenses Presbyopia Continuous wear Sport Keratoconus High ametropia Paediatric fitting Therapeutic applications Post-refractive Surgery Post-keratoplasty Orthokeratology Diabetes Part 6 Patient examination and management History taking Preliminary examination Patient education Aftercare Complications Digital imaging Compliance Practice management Appendices Index

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There have been significant improvements in toric soft contact lens design over the past decade. Data from our international contact lens prescribing survey were mined to assess recent trends in toric soft contact lens fitting. This survey was conducted by sending up to 1000 survey forms to contact lens fitters in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA each year between 2000 and 2009. Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the forms and to return them to us for analysis. The data revealed a gradual increase in the extent of toric soft lens fitting this century. Excluding Japan – which had a consistently low rate of soft toric lens fitting over the survey period – soft toric lenses now represent over 35% of all soft lenses prescribed; it can be assumed that, on average (and again excluding Japan), all cases of astigmatism 0.75 D or less remains uncorrected among contact lens wearers. Toric lenses are fitted more to those who are older, full-time wearers and reusable lens wearers, and less to those wearing silicone hydrogel and extended wear lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim/hypothesis Immune mechanisms have been proposed to play a role in the development of diabetic neuropathy. We employed in vivo corneal confocal microscopy (CCM) to quantify the presence and density of Langerhans cells (LCs) in relation to the extent of corneal nerve damage in Bowman's layer of the cornea in diabetic patients. Methods 128 diabetic patients aged 58±1 yrs with a differing severity of neuropathy based on Neuropathy Deficit Score (NDS—4.7±0.28) and 26 control subjects aged 53±3 yrs were examined. Subjects underwent a full neurological evaluation, evaluation of corneal sensation with non-contact corneal aesthesiometry (NCCA) and corneal nerve morphology using corneal confocal microscopy (CCM). Results The proportion of individuals with LCs was significantly increased in diabetic patients (73.8%) compared to control subjects (46.1%), P=0.001. Furthermore, LC density (no/mm2) was significantly increased in diabetic patients (17.73±1.45) compared to control subjects (6.94±1.58), P=0.001 and there was a significant correlation with age (r=0.162, P=0.047) and severity of neuropathy (r=−0.202, P=0.02). There was a progressive decrease in corneal sensation with increasing severity of neuropathy assessed using NDS in the diabetic patients (r=0.414, P=0.000). Corneal nerve fibre density (P<0.001), branch density (P<0.001) and length (P<0.001) were significantly decreased whilst tortuosity (P<0.01) was increased in diabetic patients with increasing severity of diabetic neuropathy. Conclusion Utilising in vivo corneal confocal microscopy we have demonstrated increased LCs in diabetic patients particularly in the earlier phases of corneal nerve damage suggestive of an immune mediated contribution to corneal nerve damage in diabetes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Scleral and corneal rigid lenses represented 100 per cent of the contact lens market immediately prior to the invention of soft lenses in the mid-1960s. In the United Kingdom today, rigid lenses comprise 2 per cent of all new lens fits. Low rates of rigid lens fitting are also apparent in 27 other countries which have recently been surveyed. Thus, the 1998 prediction of the author that rigid lenses – also referred to as ‘rigid gas permeable’ (RGP) lenses or ‘gas permeable’ (GP) lenses – would be obsolete by the year 2010 has essentially turned out to be correct. In this obituary, the author offers 10 reasons for the demise of rigid lens fitting: initial rigid lens discomfort; intractable rigid lens-induced corneal and lid pathology; extensive soft lens advertising; superior soft lens fitting logistics; lack of rigid lens training opportunities; redundancy of the rigid lens ‘problem solver’ function; improved soft toric and bifocal/varifocal lenses; limited uptake of orthokeratology; lack of investment in rigid lenses; and the emergence of aberration control soft lenses. Rigid lenses are now being fitted by a minority of practitioners with specialist skills/training. Certainly, rigid lenses can no longer be considered as a mainstream form of contact lens correction. May their dear souls (bulk properties) rest in peace.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Falls are a major health and injury problem for people with Parkinson disease (PD). Despite the severe consequences of falls, a major unresolved issue is the identification of factors that predict the risk of falls in individual patients with PD. The primary aim of this study was to prospectively determine an optimal combination of functional and disease-specific tests to predict falls in individuals with PD. ----- ----- Methods: A total of 101 people with early-stage PD undertook a battery of neurologic and functional tests in their optimally medicated state. The tests included Tinetti, Berg, Timed Up and Go, Functional Reach, and the Physiological Profile Assessment of Falls Risk; the latter assessment includes physiologic tests of visual function, proprioception, strength, cutaneous sensitivity, reaction time, and postural sway. Falls were recorded prospectively over 6 months. ----- ----- Results: Forty-eight percent of participants reported a fall and 24% more than 1 fall. In the multivariate model, a combination of the Unified Parkinson's Disease Rating Scale (UPDRS) total score, total freezing of gait score, occurrence of symptomatic postural orthostasis, Tinetti total score, and extent of postural sway in the anterior-posterior direction produced the best sensitivity (78%) and specificity (84%) for predicting falls. From the UPDRS items, only the rapid alternating task category was an independent predictor of falls. Reduced peripheral sensation and knee extension strength in fallers contributed to increased postural instability. ----- ----- Conclusions: Falls are a significant problem in optimally medicated early-stage PD. A combination of both disease-specific and balance- and mobility-related measures can accurately predict falls in individuals with PD.