785 resultados para Performance Reports
Resumo:
A high performance liquid chromatographic method for the simultaneous determination of five organochlorine pesticides (aldrin, p,p’-DDT, dieldrin, endrin, and heptachlor) was developed. The method was used to determine the levels of these pesticides in medicinal plant samples. Analysis was carried out using a Merck LiChrospher 100 RP C18 (5 μm) column with a gradient solvent system of acetonitrile-water and PDA UV detection (224 nm). Quantification was carried out by the external standard method. The limit of detection for the utilized method was below the local legal limits (ANZFA) for similar plant materials for all 5 pesticides excepting endrin. Medicinal plant extracts were further analyzed by conventional GC-ECD and GC-NPD means using SPE and GPC cleanup as required.
Resumo:
This video article articulates two exercises that have been developed to respond to the need for preparedness in the growing field of Performance Capture. The first is called Walking Through (Delbridge 2013), where the actor navigates a series of objects that exist in screen space through a developed sense of the existing physical particularities of the studio and an interaction with a screen (or feedback loop). The second exercise is called The Donut (Delbridge 2013), where the performer continues to navigate screen space but this time does so through the literal stepping through of a Torus in the virtual – again with nothing but the studio infrastructure and the screen as a guide. Notions of Motion Captured performance infer the existence of an interface that combines performer with system, separating (or intervening in) the space between performance and the screen. It is precisely the effect and provided opportunity of the intermediary device on the practice, craft and preparedness of the actor as they navigate the connection between 3D screen space and the physical properties of the studio that is examined here. Defining the scope of current practice for the contemporary actor is a key construct of this challenge, with the most appropriate definition revolving around the provision of a required mixture of performance and content for live, mediated, framed and variously captured formats. One of these particular formats is Performance Capture. The exercises presented here are two from a series, developed over a three year study that contribute to our understanding of the potential for a training regimen to be developed for the rigors of Performance Capture.
Resumo:
This research project contributed to the in-depth understanding of the influence of hydrologic and hydraulic factors on the stormwater treatment performance of constructed wetlands and bioretention basins in the "real world". The project was based on the comprehensive monitoring of a Water Sensitive Urban Design treatment train in the field and underpinned by complex multivariate statistical analysis. The project outcomes revealed that the reduction in pollutant concentrations were consistent in the constructed wetland, but was highly variable in the bioretention basin to a range of influential factors. However, due to the significant amount retention within the filter media, all pollutant loadings were reduced in the bioretention basin.
Resumo:
Assurance of Learning is a focus for many Business Schools to meet AACSB requirements. Prior research has examined student self-assessment as a measure of learning in this context, but we propose instead that this is a useful ‘learning tool’ for students and instructors that can help improve student performance and curricula. We examined self-assessment in a third year undergraduate e-marketing course and found a positive, though weak relationship between student self-assessment and instructor ratings on intended learning goals and criteria for a written assignment. Students who self-assessed tended to perform better in the assessment item and course than those who did not self-assess. But less competent students were more inaccurate in their self-assessment, suggesting a need to enhance understanding of marking criteria and performance standards within this group. Implications for educators are discussed.
High performance liquid chromatography determined alkamide levels in Australian-grown Echinacea spp.
Resumo:
Extracts of Echinacea spp. are widely used as therapeutic immunostimulants with such activity being attributed in part to the alkamide fractions of these plants. Using high performance liquid chromatography, the levels of 8 alkamides, including 2 tetraene alkamides (dodeca-2E, 4E, 8Z, 10E/Z-tetraenoic acid isobutylamide), were quantitatively determined in 2 Australian-grown Echinacea spp. Overall, the levels of alkamides in Australian-grown E. angustifolia were found to be comparable with levels obtained in this study and other studies for USA and European Echinacea spp. However, results obtained for one sample of E. angustifolia suggested that it may have been mislabelled and that it was most likely a sample of E. pallida. Levels of tetraene alkamides in Australian-grown E. purpurea were also similar to, if not higher, than levels which have been reported for the same species grown in Germany and the USA. Preliminary studies on the stability of alkamide compounds in E. angustifolia indicated that they are susceptible to degradation, with a 13% loss of alkamide level over 2 months. Overall, results indicate that there is considerable potential to develop Echinacea as a viable crop in Australia.