805 resultados para Tobacco Control


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mining industry is highly suitable for the application of robotics and automation technology since the work is both arduous and dangerous. Visual servoing is a means of integrating noncontact visual sensing with machine control to augment or replace operator based control. This article describes two of our current mining automation projects in order to demonstrate some, perhaps unusual, applications of visual servoing, and also to illustrate some very real problems with robust computer vision

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power line inspection is a vital function for electricity supply companies but it involves labor-intensive and expensive procedures which are tedious and error-prone for humans to perform. A possible solution is to use an unmanned aerial vehicle (UAV) equipped with video surveillance equipment to perform the inspection. This paper considers how a small, electrically driven rotorcraft conceived for this application could be controlled by visually tracking the overhead supply lines. A dynamic model for a ducted-fan rotorcraft is presented and used to control the action of an Air Vehicle Simulator (AVS), consisting of a cable-array robot. Results show how visual data can be used to determine, and hence regulate in closed loop, the simulated vehicle’s position relative to the overhead lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the internet age, copyright owners are increasingly looking to online intermediaries to take steps to prevent copyright infringement. Sometimes these intermediaries are closely tied to the acts of infringement; sometimes – as in the case of ISPs – they are not. In 2012, the Australian High Court decided the Roadshow Films v iiNet case, in which it held that an Australian ISP was not liable under copyright’s authorization doctrine, which asks whether the intermediary has sanctioned, approved or countenanced the infringement. The Australian Copyright Act 1968 directs a court to consider, in these situations, whether the intermediary had the power to prevent the infringement and whether it took any reasonable steps to prevent or avoid the infringement. It is generally not difficult for a court to find the power to prevent infringement – power to prevent can include an unrefined technical ability to disconnect users from the copyright source, such as an ISP terminating users’ internet accounts. In the iiNet case, the High Court eschewed this broad approach in favor of focusing on a notion of control that was influenced by principles of tort law. In tort, when a plaintiff asserts that a defendant should be liable for failing to act to prevent harm caused to the plaintiff by a third party, there is a heavy burden on the plaintiff to show that the defendant had a duty to act. The duty must be clear and specific, and will often hinge on the degree of control that the defendant was able to exercise over the third party. Control in these circumstances relates directly to control over the third party’s actions in inflicting the harm. Thus, in iiNet’s case, the control would need to be directed to the third party’s infringing use of BitTorrent; control over a person’s ability to access the internet is too imprecise. Further, when considering omissions to act, tort law differentiates between the ability to control and the ability to hinder. The ability to control may establish a duty to act, and the court will then look to small measures taken to prevent the harm to determine whether these satisfy the duty. But the ability to hinder will not suffice to establish liability in the absence of control. This article argues that an inquiry grounded in control as defined in tort law would provide a more principled framework for assessing the liability of passive intermediaries in copyright. In particular, it would set a higher, more stable benchmark for determining the copyright liability of passive intermediaries, based on the degree of actual, direct control that the intermediary can exercise over the infringing actions of its users. This approach would provide greater clarity and consistency than has existed to date in this area of copyright law in Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this review is to identify the effectiveness of education or behavioral interventions on adherence to phosphate control in adults with end stage kidney disease (ESKD) receiving hemodialysis (HD).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mike Budd and Max H. Kirsch, eds. Rethinking Disney: Private Control, Public Dimensions. Middletown, CT: Wesleyan University Press, 2005. ix + 341pp. $27.95

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to describe an innovative compliance control architecture for hybrid multi‐legged robots. The approach was verified on the hybrid legged‐wheeled robot ASGUARD, which was inspired by quadruped animals. The adaptive compliance controller allows the system to cope with a variety of stairs, very rough terrain, and is also able to move with high velocity on flat ground without changing the control parameters. Design/methodology/approach – The paper shows how this adaptivity results in a versatile controller for hybrid legged‐wheeled robots. For the locomotion control we use an adaptive model of motion pattern generators. The control approach takes into account the proprioceptive information of the torques, which are applied on the legs. The controller itself is embedded on a FPGA‐based, custom designed motor control board. An additional proprioceptive inclination feedback is used to make the same controller more robust in terms of stair‐climbing capabilities. Findings – The robot is well suited for disaster mitigation as well as for urban search and rescue missions, where it is often necessary to place sensors or cameras into dangerous or inaccessible areas to get a better situation awareness for the rescue personnel, before they enter a possibly dangerous area. A rugged, waterproof and dust‐proof corpus and the ability to swim are additional features of the robot. Originality/value – Contrary to existing approaches, a pre‐defined walking pattern for stair‐climbing was not used, but an adaptive approach based only on internal sensor information. In contrast to many other walking pattern based robots, the direct proprioceptive feedback was used in order to modify the internal control loop, thus adapting the compliance of each leg on‐line.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The inspection of marine vessels is currently performed manually. Inspectors use tools (e.g. cameras and devices for non-destructive testing) to detect damaged areas, cracks, and corrosion in large cargo holds, tanks, and other parts of a ship. Due to the size and complex geometry of most ships, ship inspection is time-consuming and expensive. The EU-funded project INCASS develops concepts for a marine inspection robotic assistant system to improve and automate ship inspections. In this paper, we introduce our magnetic wall–climbing robot: Marine Inspection Robotic Assistant (MIRA). This semiautonomous lightweight system is able to climb a vessels steel frame to deliver on-line visual inspection data. In addition, we describe the design of the robot and its building subsystems as well as its hardware and software components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integration of small-scale electricity generators, known as distributed generation (DG), into the distribution networks has become increasingly popular at the present. This tendency together with the falling price of the synchronous-type generator has potential to give DG a better chance at participating in the voltage regulation process together with other devices already available in the system. The voltage control issue turns out to be a very challenging problem for the distribution engineers since existing control coordination schemes would need to be reconsidered to take into account the DG operation. In this paper, we propose a control coordination technique, which is able to utilize the ability of DG as a voltage regulator and, at the same time, minimize interaction with other active devices, such as an on-load tap changing transformer and a voltage regulator. The technique has been developed based on the concept of control zone, line drop compensation, dead band, as well as the choice of controllers' parameters. Simulations carried out on an Australian system show that the technique is suitable and flexible for any system with multiple regulating devices including DG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a non-linear excitation controller using inverse filtering is proposed to damp inter-area oscillations. The proposed controller is based on determining generator flux value for the next sampling time which is obtained by maximising reduction rate of kinetic energy of the system after the fault. The desired flux for the next time interval is obtained using wide-area measurements and the equivalent area rotor angles and velocities are predicted using a non-linear Kalman filter. A supplementary control input for the excitation system, using inverse filtering approach, to track the desired flux is implemented. The inverse filtering approach ensures that the non-linearity introduced because of saturation is well compensated. The efficacy of the proposed controller with and without communication time delay is evaluated on different IEEE benchmark systems including Kundur's two area, Western System Coordinating Council three-area and 16-machine, 68-bus test systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This article describes infection prevention and control professionals’ (ICPs’) staffing levels, patient outcomes, and costs associated with the provision of infection prevention and control services in Australian hospitals. A secondary objective was to determine the priorities for infection control units. Methods: A cross-sectional study design was used. Infection control units in Australian public and private hospitals completed a Web-based anonymous survey. Data collected included details about the respondent; hospital demographics; details and services of the infection control unit; and a description of infection prevention and control-related outputs, patient outcomes, and infection control priorities. Results: Forty-nine surveys were undertaken, accounting for 152 Australian hospitals. The mean number of ICPs was 0.66 per 100 overnight beds (95% confidence interval, 0.55-0.77). Privately funded hospitals have significantly fewer ICPs per 100 overnight beds compared with publicly funded hospitals (P < .01). Staffing costs for nursing staff in infection control units in this study totaled $16,364,392 (mean, $380,566). Infection control units managing smaller hospitals (<270 beds) identified the need for increased access to infectious diseases or microbiology support. Conclusion: This study provides valuable information to support future decisions by funders, hospital administrators, and ICPs on service delivery models for infection prevention and control. Further, it is the first to provide estimates of the resourcing and cost of staffing infection control in hospitals at a national level. Copyright

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose This study tested the effectiveness of a pressure ulcer (PU) prevention bundle in reducing the incidence of PUs in critically ill patients in two Saudi intensive care units (ICUs). Design A two-arm cluster randomized experimental control trial. Methods Participants in the intervention group received the PU prevention bundle, while the control group received standard skin care as per the local ICU policies. Data collected included demographic variables (age, diagnosis, comorbidities, admission trajectory, length of stay) and clinical variables (Braden Scale score, severity of organ function score, mechanical ventilation, PU presence, and staging). All patients were followed every two days from admission through to discharge, death, or up to a maximum of 28 days. Data were analyzed with descriptive correlation statistics, Kaplan-Meier survival analysis, and Poisson regression. Findings The total number of participants recruited was 140: 70 control participants (with a total of 728 days of observation) and 70 intervention participants (784 days of observation). PU cumulative incidence was significantly lower in the intervention group (7.14%) compared to the control group (32.86%). Poisson regression revealed the likelihood of PU development was 70% lower in the intervention group. The intervention group had significantly less Stage I (p = 002) and Stage II PU development (p = 026). Conclusions Significant improvements were observed in PU-related outcomes with the implementation of the PU prevention bundle in the ICU; PU incidence, severity, and total number of PUs per patient were reduced. Clinical Relevance Utilizing a bundle approach and standardized nursing language through skin assessment and translation of the knowledge to practice has the potential to impact positively on the quality of care and patient outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the objectives of this study was to evaluate soil testing equipment based on its capability of measuring in-place stiffness or modulus values. As design criteria transition from empirical to mechanistic-empirical, soil test methods and equipment that measure properties such as stiffness and modulus and how they relate to Florida materials are needed. Requirements for the selected equipment are that they be portable, cost effective, reliable, a ccurate, and repeatable. A second objective is that the selected equipment measures soil properties without the use of nuclear materials.The current device used to measure soil compaction is the nuclear density gauge (NDG). Equipment evaluated in this research included lightweight deflectometers (LWD) from different manufacturers, a dynamic cone penetrometer (DCP), a GeoGauge, a Clegg impact soil tester (CIST), a Briaud compaction device (BCD), and a seismic pavement analyzer (SPA). Evaluations were conducted over ranges of measured densities and moistures.Testing (Phases I and II) was conducted in a test box and test pits. Phase III testing was conducted on materials found on five construction projects located in the Jacksonville, Florida, area. Phase I analyses determined that the GeoGauge had the lowest overall coefficient of variance (COV). In ascending order of COV were the accelerometer-type LWD, the geophone-type LWD, the DCP, the BCD, and the SPA which had the highest overall COV. As a result, the BCD and the SPA were excluded from Phase II testing.In Phase II, measurements obtained from the selected equipment were compared to the modulus values obtained by the static plate load test (PLT), the resilient modulus (MR) from laboratory testing, and the NDG measurements. To minimize soil and moisture content variability, the single spot testing sequence was developed. At each location, test results obtained from the portable equipment under evaluation were compared to the values from adjacent NDG, PLT, and laboratory MR measurements. Correlations were developed through statistical analysis. Target values were developed for various soils for verification on similar soils that were field tested in Phase III. The single spot testing sequence also was employed in Phase III, field testing performed on A-3 and A-2-4 embankments, limerock-stabilized subgrade, limerock base, and graded aggregate base found on Florida Department of Transportation construction projects. The Phase II and Phase III results provided potential trend information for future research—specifically, data collection for in-depth statistical analysis for correlations with the laboratory MR for specific soil types under specific moisture conditions. With the collection of enough data, stronger relationships could be expected between measurements from the portable equipment and the MR values. Based on the statistical analyses and the experience gained from extensive use of the equipment, the combination of the DCP and the LWD was selected for in-place soil testing for compaction control acceptance. Test methods and developmental specifications were written for the DCP and the LWD. The developmental specifications include target values for the compaction control of embankment, subgrade, and base materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent 'Global Burden of Disease' studies have provided quantitative evidence of the significant role air pollution plays as a human health risk factor (Lim et al., The Lancet, 380: 2224–2260, 2012). Tobacco smoke, including second hand smoke, household air pollution from solid fuels and ambient particulate matter are among the top risks, leading to lower life expectancy around the world. Indoor air constitutes an environment particularly rich in different types of pollutants, originating from indoor sources, as well as penetrating from outdoors, mixing, interacting or growing (when considering microbes) under the protective enclosure of the building envelope. Therefore, it is not a simple task to follow the dynamics of the processes occurring there, or to quantify the outcomes of the processes in terms of pollutant concentrations and other characteristics. This is further complicated by limitations such as building access for the purpose of air quality monitoring, or the instrumentation which can be used indoors, because of their possible interference with the occupants comfort (due to their large size, noise generated or amount of air drawn). European studies apportioned contributions of indoor versus outdoor sources of indoor air contaminants in 26 European countries and quantified IAQ associated DALYs (Disability-Adjusted Life Years) in those countries (Jantunen et al., Promoting actions for healthy indoor air (IAIAQ), European Commission Directorate General for Health and Consumers, Luxembourg, 2011). At the same time, there has been an increase in research efforts around the world to better understand the sources, composition, dynamics and impacts of indoor air pollution. Particular focus has been directed towards the contemporary sources, novel pollutants and new detection methods. The importance of exposure assessment and personal exposure, the majority of which occurs in various indoor micro¬environments, has also been realized. Overall, this emerging knowledge has been providing input for global assessments of indoor environments, the impact of indoor pollutants and their science based management and control. It was a major outcome of recent international conferences that interdisciplinarity and especially a better colla¬boration between exposure and indoor sciences would be of high benefit for the health related evaluation of environmental stress factors and pollutants. A very good example is the combination of biomonitoring and indoor air, particle and dust analysis to study the exposure routes of semi volatile organic compounds (SVOCs). We have adopted the idea of combining the forces of exposure and indoor sciences for this Special Issue, identified new and challenging topics and have attracted colleagues who are top researchers in their field to provide their inputs. The Special Issue includes papers, which collectively present advances in current research topics and in our view, build the bridge between indoor and exposure sciences.