399 resultados para model testing
Resumo:
This paper provides a first look at the acceptance of Accountable-eHealth systems, a new genre of eHealth systems, designed to manage information privacy concerns that hinder the proliferation of eHealth. The underlying concept of AeH systems is appropriate use of information through after-the-fact accountability for intentional misuse of information by healthcare professionals. An online questionnaire survey was utilised for data collection from three educational institutions in Queensland, Australia. A total of 23 hypothesis relating to 9 constructs were tested using a structural equation modelling technique. A total of 334 valid responses were received. The cohort consisted of medical, nursing and other health related students studying at various levels in both undergraduate and postgraduate courses. The hypothesis testing disproved 7 hypotheses. The empirical research model developed was capable of predicting 47.3% of healthcare professionals’ perceived intention to use AeH systems. A validation of the model with a wider survey cohort would be useful to confirm the current findings.
Resumo:
This project examined the differences in healing of metaphyseal bone, when the implants of variable stiffness are used for fracture fixation. This knowledge is important in development of novel orthopaedic implants, used in orthopaedic surgery to stabilise the fractures. Dr Koval used a mouse model to create a fracture, and then assessed its healing with a combination of mechanical testing, microcomputed tomography and histomorphometric examination.
Resumo:
A new strategy for rapidly selecting and testing genetic vaccines has been developed, in which a whole genome library is cloned into a bacteriophage λ ZAP Express vector which contains both prokaryotic (Plac) and eukaryotic (PCMV) promoters upstream of the insertion site. The phage library is plated on Escherichia coli cells, immunoblotted, and probed with hyperimmune and/or convalescent-phase antiserum to rapidly identify vaccine candidates. These are then plaque purified and grown as liquid lysates, and whole bacteriophage particles are then used directly to immunize the host, following which PCMV-driven expression of the candidate vaccine gene occurs. In the example given here, a semirandom genome library of the bovine pathogen Mycoplasma mycoides subsp. mycoides small colony (SC) biotype was cloned into λ ZAP Express, and two strongly immunodominant clones, λ-A8 and λ-B1, were identified and subsequently tested for vaccine potential against M. mycoides subsp. mycoides SC biotype-induced mycoplasmemia. Sequencing and immunoblotting indicated that clone λ-A8 expressed an isopropyl-β-d-thiogalactopyranoside (IPTG)-inducible M. mycoides subsp. mycoides SC biotype protein with a 28-kDa apparent molecular mass, identified as a previously uncharacterized putative lipoprotein (MSC_0397). Clone λ-B1 contained several full-length genes from the M. mycoides subsp. mycoides SC biotype pyruvate dehydrogenase region, and two IPTG-independent polypeptides, of 29 kDa and 57 kDa, were identified on immunoblots. Following vaccination, significant anti-M. mycoides subsp. mycoides SC biotype responses were observed in mice vaccinated with clones λ-A8 and λ-B1. A significant stimulation index was observed following incubation of splenocytes from mice vaccinated with clone λ-A8 with whole live M. mycoides subsp. mycoides SC biotype cells, indicating cellular proliferation. After challenge, mice vaccinated with clone λ-A8 also exhibited a reduced level of mycoplasmemia compared to controls, suggesting that the MSC_0397 lipoprotein has a protective effect in the mouse model when delivered as a bacteriophage DNA vaccine. Bacteriophage-mediated immunoscreening using an appropriate vector system offers a rapid and simple technique for the identification and immediate testing of putative candidate vaccines from a variety of pathogens.
Resumo:
A novel burn wound hydrogel dressing has been previously developed which is composed of 2-acrylamido-2-methylpropane sulfonic acid sodium salt with silver nanoparticles (silver AMPS). This study compared the cytotoxicity of this dressing to the commercially available silver products; Acticoat™, PolyMem Silver® and Flamazine™ cream. Human keratinocytes (HaCaT and primary HEK) and normal human fibroblasts (NHF) were exposed to dressings incubated on Nunc™ polycarbonate inserts for 24, 48 and 72h. Four different cytotoxicity assays were performed including; Trypan Blue cell count, MTT, Celltiter-Blue™ and Toluidine Blue surface area assays. The results were expressed as relative cell viability compared to an untreated control. The cytotoxic effects of Acticoat™ and Flamazine™ cream were dependent on exposure time and cell type. After 24h exposure, Acticoat™ and Flamazine™ cream were toxic to all tested cell lines. Surprisingly, HaCaTs treated with Acticoat™ and Flamazine™ had an improved ability to survive at 48 and 72h while HEKs and NHFs had no improvement in survival with any treatment. The novel silver hydrogel and PolyMem Silver® showed low cytotoxicity to all tested cell lines at every time interval and these results support the possibility of using the novel silver hydrogel as a burn wound dressing. Researchers who rely on HaCaT cells as an accurate keratinocyte model should be aware that they can respond differently to primary skin cells.
Resumo:
In a tag-based recommender system, the multi-dimensional
Resumo:
This study assessed the prevalence of and factors associated with HIV testing among male street laborers. In a cross-sectional survey, social mapping was done to recruit and interview 450 men aged 18–59 years in Hanoi. Although many of these men engaged in multiple risk behaviors for HIV, only 19.8 percent had been tested for HIV. A modified theoretical model provided better fit than the conventional Information–Motivation–Behavioral Skills model, as it explained much more variance in HIV testing. This model included three Information–Motivation–Behavioral components and four additional factors, namely, the origin of residence, sexual orientation, the number of sexual partners, and the status of condom use.
Resumo:
This project develops the required guidelines to assure stable and accurate operation of Power-Hardware-in-the-Loop implementations. The proposals of this research have been theoretically analyzed and practically examined using a Real-Time Digital Simulator. In this research, the interaction between software simulated power network and the physical power system has been studied. The conditions for different operating regimes have been derived and the corresponding analyses have been presented.
Resumo:
This special issue of Cultural Science Journal is devoted to the report of a groundbreaking experiment in re-coordinating global markets for specialist scholarly books and enabling the knowledge commons: the Knowledge Unlatched proof-of-concept pilot. The pilot took place between January 2012 and September 2014. It involved libraries, publishers, authors, readers and research funders in the process of developing and testing a global library consortium model for supporting Open Access books. The experiment established that authors, librarians, publishers and research funding agencies can work together in powerful new ways to enable open access; that doing so is cost effective; and that a global library consortium model has the potential dramatically to widen access to the knowledge and ideas contained in book-length scholarly works.
Resumo:
Many researchers in the field of civil structural health monitoring have developed and tested their methods on simple to moderately complex laboratory structures such as beams, plates, frames, and trusses. Field work has also been conducted by many researchers and practitioners on more complex operating bridges. Most laboratory structures do not adequately replicate the complexity of truss bridges. This paper presents some preliminary results of experimental modal testing and analysis of the bridge model presented in the companion paper, using the peak picking method, and compares these results with those of a simple numerical model of the structure. Three dominant modes of vibration were experimentally identified under 15 Hz. The mode shapes and order of the modes matched those of the numerical model; however, the frequencies did not match.
Resumo:
Background The growing awareness of transfusion-associated morbidity and mortality necessitates investigations into the underlying mechanisms. Small animals have been the dominant transfusion model but have associated limitations. This study aimed to develop a comprehensive large animal (ovine) model of transfusion encompassing: blood collection, processing and storage, compatibility testing right through to post-transfusion outcomes. Materials and methods Two units of blood were collected from each of 12 adult male Merino sheep and processed into 24 ovine-packed red blood cell (PRBC) units. Baseline haematological parameters of ovine blood and PRBC cells were analysed. Biochemical changes in ovine PRBCs were characterized during the 42-day storage period. Immunological compatibility of the blood was confirmed with sera from potential recipient sheep, using a saline and albumin agglutination cross-match. Following confirmation of compatibility, each recipient sheep (n = 12) was transfused with two units of ovine PRBC. Results Procedures for collecting, processing, cross-matching and transfusing ovine blood were established. Although ovine red blood cells are smaller and higher in number, their mean cell haemoglobin concentration is similar to human red blood cells. Ovine PRBC showed improved storage properties in saline–adenine–glucose–mannitol (SAG-M) compared with previous human PRBC studies. Seventy-six compatibility tests were performed and 17·1% were incompatible. Only cross-match compatible ovine PRBC were transfused and no adverse reactions were observed. Conclusion These findings demonstrate the utility of the ovine model for future blood transfusion studies and highlight the importance of compatibility testing in animal models involving homologous transfusions.
Resumo:
Changes to the redox status of biological systems have been implicated in the pathogenesis of a wide variety of disorders including cancer, Ischemia-reperfusion (I/R) injury and neurodegeneration. In times of metabolic stress e.g. ischaemia/reperfusion, reactive oxygen species (ROS) production overwhelms the intrinsic antioxidant capacity of the cell, damaging vital cellular components. The ability to quantify ROS changes in vivo, is therefore essential to understanding their biological role. Here we evaluate the suitability of a novel reversible profluorescent probe containing a redox-sensitive nitroxide moiety (methyl ester tetraethylrhodamine nitroxide, ME-TRN), as an in vivo, real-time reporter of retinal oxidative status. The reversible nature of the probe's response offers the unique advantage of being able to monitor redox changes in both oxidizing and reducing directions in real time. After intravitreal administration of the ME-TRN probe, we induced ROS production in rat retina using an established model of complete, acute retinal ischaemia followed by reperfusion. After restoration of blood flow, retinas were imaged using a Micron III rodent fundus fluorescence imaging system, to quantify the redox-response of the probe. Fluorescent intensity declined during the first 60 min of reperfusion. The ROS-induced change in probe fluorescence was ameliorated with the retinal antioxidant, lutein. Fluorescence intensity in non-Ischemia eyes did not change significantly. This new probe and imaging technology provide a reversible and real-time response to oxidative changes and may allow the in vivo testing of antioxidant therapies of potential benefit to a range of diseases linked to oxidative stress
Resumo:
The purpose of this study was to establish a three-dimensional fluorescent tooth model to investigate bacterial viability against intra-canal medicaments across the thickness and surface of root dentine. Dental microbial biofilms (Enterococcus faecalis and Streptococcus mutans) were established on the external root surface and bacterial kill was monitored over time against intra-canal medicament (Ca(OH)2 ) using fluorescent microscopy in conjunction with BacLight SYTO9 and propidium iodide stains. An Olympus digital camera fitted to SZX16 fluorescent microscope captured images of bacterial cells in biofilms on the external root surface. Viability of biofilm was measured by calculating the total pixel area of green (viable bacteria) and red (non-viable bacteria) for each image using ImageJ® software. All data generated were assessed for normality and then analysed using a Mann-Whitney t-test. The viability of S. mutans biofilm following Ca(OH)2 treatment showed a significant decline compared with the untreated group (P = 0.0418). No significant difference was seen for E. faecalis biofilm between the Ca(OH)2 and untreated groups indicating Ca(OH)2 medicament is ineffective against E. faecalis biofilm. This novel three-dimensional fluorescent biofilm model provides a new clinically relevant tool for testing of medicaments against dental biofilms.
Resumo:
This paper provides a first look at the acceptance of Accountable-eHealth (AeH) systems–a new genre of eHealth systems designed to manage information privacy concerns that hinder the proliferation of eHealth. The underlying concept of AeH systems is appropriate use of information through after-the-fact accountability for intentional misuse of information by healthcare professionals. An online questionnaire survey was utilised for data collection from three educational institutions in Queensland, Australia. A total of 23 hypotheses relating to 9 constructs were tested using a structural equation modelling technique. The moderation effects on the hypotheses were also tested based on six moderation factors to understand their role on the designed research model. A total of 334 valid responses were received. The cohort consisted of medical, nursing and other health related students studying at various levels in both undergraduate and postgraduate courses. Hypothesis testing provided sufficient data to accept 7 hypotheses. The empirical research model developed was capable of predicting 47.3% of healthcare professionals’ perceived intention to use AeH systems. All six moderation factors showed significant influence on the research model. A validation of this model with a wider survey cohort is recommended as a future study.
Resumo:
In this note, we shortly survey some recent approaches on the approximation of the Bayes factor used in Bayesian hypothesis testing and in Bayesian model choice. In particular, we reassess importance sampling, harmonic mean sampling, and nested sampling from a unified perspective.
Resumo:
Due to the advent of varied types of masonry systems a comprehensive failure mechanism of masonry essential for the understanding of its behaviour is impossible to be determined from experimental testing. As masonry is predominantly used in wall structures a biaxial stress state dominates its failure mechanism. Biaxial testing will therefore be necessary for each type of masonry, which is expensive and time consuming. A computational method would be advantageous; however masonry is complex to model which requires advanced computational modelling methods. This thesis has formulated a damage mechanics inspired modelling method and has shown that the method effectively determines the failure mechanisms and deformation characteristics of masonry under biaxial states of loading.