67 resultados para invasiveness


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Head and neck cancers (HNCs) represent a significant and ever-growing burden to the modern society, mainly due to the lack of early diagnostic methods. A significant number of HNCs is often associated with drinking, smoking, chewing beetle nut, and human papilloma virus (HPV) infections. We have analyzed DNA methylation patterns in tumor and normal tissue samples collected from head and neck squamous cell carcinoma (HNSCC) patients who were smokers. We have identified novel methylation sites in the promoter of the mediator complex subunit 15 (MED15/PCQAP) gene (encoing a co-factor important for regulation of transcription initiation for promoters of many genes), hypermethylated specifically in tumor cells. Two clusters of CpG dinucleotides methylated in tumors, but not in normal tissue from the same patients, were identified. These CpG methylation events in saliva samples were further validated in a separate cohort of HNSCC patients (who developed cancer due to smoking or HPV infections) and healthy controls using methylation-specific PCR (MSP). We used saliva as a biological medium because of its non-invasive nature, close proximity to the tumors, easiness and it is an economically viable option for large-scale screening studies. The methylation levels for the two identified CpG clusters were significantly different between the saliva samples collected from healthy controls and HNSCC individuals (Welch's t-test returning P, 0.05 and Mann-Whitney test P, 0.01 for both). The developed MSP assays also provided a good discriminative ability with AUC values of 0.70 (P, 0.01) and 0.63 (P, 0.05). The identified novel CpG methylation sites may serve as potential non-invasive biomarkers for detecting HNSCC. © the authors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Premise of the study: Plant invasiveness can be promoted by higher values of adaptive traits (e.g., photosynthetic capacity, biomass accumulation), greater plasticity and coordination of these traits, and by higher and positive relative influence of these functionalities on fitness, such as increasing reproductive output. However, the dataset for this premise rarely include linkages between epidermal-stomatal traits, leaf internal anatomy, and physiological performance. Methods: Three ecological pairs of invasive vs non-invasive (native) woody vine species of South-East Queensland, Australia were investigated for trait differences in leaf morphology and anatomy under varying light intensity. The linkages of these traits with physiological performance (e.g. water use efficiency, photosynthesis, and leaf construction cost) and plant adaptive traits of specific leaf area, biomass, and relative growth rates were also explored. Key results: Mean leaf anatomical trait differed significantly between the two groups, except for stomatal size. Plasticity of traits, and to a very limited extent, their phenotypic integration were higher in the invasive relative to the native species. ANOVA, ordination, and analysis of similarity suggest that for leaf morphology and anatomy, the three functional strategies contribute to the differences between the two groups in the order phenotypic plasticity > trait means > phenotypic integration. Conclusions: The linkages demonstrated in the study between stomatal complex/gross anatomy and physiology are scarce in the ecological literature of plant invasiveness, but the findings suggest that leaf anatomical traits need to be considered routinely as part of weed species assessment and in the worldwide leaf economic spectrum.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

- Background In the UK, women aged 50–73 years are invited for screening by mammography every 3 years. In 2009–10, more than 2.24 million women in this age group in England were invited to take part in the programme, of whom 73% attended a screening clinic. Of these, 64,104 women were recalled for assessment. Of those recalled, 81% did not have breast cancer; these women are described as having a false-positive mammogram. - Objective The aim of this systematic review was to identify the psychological impact on women of false-positive screening mammograms and any evidence for the effectiveness of interventions designed to reduce this impact. We were also looking for evidence of effects in subgroups of women. - Data sources MEDLINE, MEDLINE In-Process & Other Non-Indexed Citations, EMBASE, Health Management Information Consortium, Cochrane Central Register for Controlled Trials, Cochrane Database of Systematic Reviews, Centre for Reviews and Dissemination (CRD) Database of Abstracts of Reviews of Effects, CRD Health Technology Assessment (HTA), Cochrane Methodology, Web of Science, Science Citation Index, Social Sciences Citation Index, Conference Proceedings Citation Index-Science, Conference Proceeding Citation Index-Social Science and Humanities, PsycINFO, Cumulative Index to Nursing and Allied Health Literature, Sociological Abstracts, the International Bibliography of the Social Sciences, the British Library's Electronic Table of Contents and others. Initial searches were carried out between 8 October 2010 and 25 January 2011. Update searches were carried out on 26 October 2011 and 23 March 2012. - Review methods Based on the inclusion criteria, titles and abstracts were screened independently by two reviewers. Retrieved papers were reviewed and selected using the same independent process. Data were extracted by one reviewer and checked by another. Each included study was assessed for risk of bias. - Results Eleven studies were found from 4423 titles and abstracts. Studies that used disease-specific measures found a negative psychological impact lasting up to 3 years. Distress increased with the level of invasiveness of the assessment procedure. Studies using instruments designed to detect clinical levels of morbidity did not find this effect. Women with false-positive mammograms were less likely to return for the next round of screening [relative risk (RR) 0.97; 95% confidence interval (CI) 0.96 to 0.98] than those with normal mammograms, were more likely to have interval cancer [odds ratio (OR) 3.19 (95% CI 2.34 to 4.35)] and were more likely to have cancer detected at the next screening round [OR 2.15 (95% CI 1.55 to 2.98)]. - Limitations This study was limited to UK research and by the robustness of the included studies, which frequently failed to report quality indicators, for example failure to consider the risk of bias or confounding, or failure to report participants' demographic characteristics. - Conclusions We conclude that the experience of having a false-positive screening mammogram can cause breast cancer-specific psychological distress that may endure for up to 3 years, and reduce the likelihood that women will return for their next round of mammography screening. These results should be treated cautiously owing to inherent weakness of observational designs and weaknesses in reporting. Future research should include a qualitative interview study and observational studies that compare generic and disease-specific measures, collect demographic data and include women from different social and ethnic groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

- Objectives To identify the psychological effects of false-positive screening mammograms in the UK. - Methods Systematic review of all controlled studies and qualitative studies of women with a false-positive screening mammogram. The control group participants had normal mammograms. All psychological outcomes including returning for routine screening were permitted. All studies had a narrative synthesis. - Results The searches returned seven includable studies (7/4423). Heterogeneity was such that meta-analysis was not possible. Studies using disease-specific measures found that, compared to normal results, there could be enduring psychological distress that lasted up to 3 years; the level of distress was related to the degree of invasiveness of the assessment. At 3 years the relative risks were, further mammography, 1.28 (95% CI 0.82 to 2.00), fine needle aspiration 1.80 (95% CI 1.17 to 2.77), biopsy 2.07 (95% CI 1.22 to 3.52) and early recall 1.82 (95% CI 1.22 to 2.72). Studies that used generic measures of anxiety and depression found no such impact up to 3 months after screening. Evidence suggests that women with false-positive mammograms have an increased likelihood of failing to reattend for routine screening, relative risk 0.97 (95% CI 0.96 to 0.98) compared with women with normal mammograms. - Conclusions Having a false-positive screening mammogram can cause breast cancer-specific distress for up to 3 years. The degree of distress is related to the invasiveness of the assessment. Women with false-positive mammograms are less likely to return for routine assessment than those with normal ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined factors (e.g., ad values and social networking advertising characteristics) influencing consumers' attitudes and behavioural intention towards three types of social networking advertising (SNA) on Facebook – home page ad, social impression ad, and organic impression ad. Findings demonstrate that peer influence had the most significant impacts on attitude and behavioural intention across all types of SNA. The significant interaction term of invasiveness and privacy concern indicates that both attitude and behavioural intention were diminished, particularly when perceived invasiveness and privacy concern were high simultaneously. In addition, results suggest that attitudes towards the ad played a mediating role between SNA characteristics and behavioural intention. Lastly, among the types of SNA, consumers preferred organic impression ads that featured friends' names on their newsfeed more than paid ads located on the sidebar of their Facebook pages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim and objectives To identify the prevalence that temperature reduced by more than 1°C from pre to post-procedure in a sample of non-anaesthetised patients undergoing procedures in a cardiac catheterisation laboratory. Background Advances in medical technology are minimising the invasiveness of diagnostic tests and treatments for disease, which is correspondingly increasing the number of medical procedures performed without sedation or anaesthesia. Procedural areas in which medical procedures are performed without anaesthesia are typically kept at a cool temperature for staff comfort. As such, there is a need to inform nursing practices in regard to the thermal management of non-anaesthetised patients undergoing procedures in surgical or procedural environments. Design Single-site observational study Methods Patients were included if they had undergone an elective procedure without sedation or anaesthesia in a cardiac catheterisation laboratory. Ambient room temperature was maintained between 18°C and 20°C. Passive warming with heated cotton blankets was applied. Nurses measured body temperature and thermal comfort before and after 342 procedures. Results Mean change in temperature was -0.08°C (Standard deviation 0.43). The reduction in temperature was more than 1°C after 11 procedures (3.2%). One patient whose temperature had reduced more than 1°C after their procedure reported thermal discomfort. A total of 12 patients were observed to be shivering post-procedure (3.6%). No demographic or clinical characteristics were associated with reduction in temperature of more than 1°C from pre to post-procedure. Conclusions Significant reduction in body temperature was rare in our sample of non-anaesthetised patients. Relevance to clinical practice Similar results would likely be found in other procedural contexts during procedures conducted in settings with comparable room temperatures where passive warming can also be applied with limited skin exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coptotermes Wasmann (Isoptera: Rhinotermitidae) is one of the most economically important subterranean termite genera and some species are successful invaders. However, despite its important pest status, the taxonomic validity of many named Coptotermes species remains unclear. In this study, we reviewed all named species within the genus and investigated evidence supporting the validity of each named species. Species were systematically scrutinized according to the region of their original description: Southeast Asia, India, China, Africa, the Neotropics, and Australia. We estimate that of the currently 69 named species described by accepted nomenclatural rules, only 21 taxa have solid evidence for validity, 44 names have uncertain status, and the remaining species names should be synonymized or were made unavailable. Species with high degrees of invasiveness may be known under additional junior synonyms due to independent parochial descriptions. Molecular data for a vast majority of species are scarce and significant effort is needed to complete the taxonomic and phylogenetic revision of the genus. Because of the wide distribution of Coptotermes, we advocate for an integrative taxonomic effort to establish the distribution of each putative species, provide specimens and corresponding molecular data, check original descriptions and type specimens (if available), and provide evidence for a more robust phylogenetic position of each species. This study embodies both consensus and contention of those studying Coptotermes and thus pinpoints the current uncertainty of many species. This project is intended to be a roadmap for identifying those Coptotermes species names that need to be more thoroughly investigated, as an incentive to complete a necessary revision process.