125 resultados para impedance audiometry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioelectrical impedance analysis, (BIA), is a method of body composition analysis first investigated in 1962 which has recently received much attention by a number of research groups. The reasons for this recent interest are its advantages, (viz: inexpensive, non-invasive and portable) and also the increasing interest in the diagnostic value of body composition analysis. The concept utilised by BIA to predict body water volumes is the proportional relationship for a simple cylindrical conductor, (volume oc length2/resistance), which allows the volume to be predicted from the measured resistance and length. Most of the research to date has measured the body's resistance to the passage of a 50· kHz AC current to predict total body water, (TBW). Several research groups have investigated the application of AC currents at lower frequencies, (eg 5 kHz), to predict extracellular water, (ECW). However all research to date using BIA to predict body water volumes has used the impedance measured at a discrete frequency or frequencies. This thesis investigates the variation of impedance and phase of biological systems over a range of frequencies and describes the development of a swept frequency bioimpedance meter which measures impedance and phase at 496 frequencies ranging from 4 kHz to 1 MHz. The impedance of any biological system varies with the frequency of the applied current. The graph of reactance vs resistance yields a circular arc with the resistance decreasing with increasing frequency and reactance increasing from zero to a maximum then decreasing to zero. Computer programs were written to analyse the measured impedance spectrum and determine the impedance, Zc, at the characteristic frequency, (the frequency at which the reactance is a maximum). The fitted locus of the measured data was extrapolated to determine the resistance, Ro, at zero frequency; a value that cannot be measured directly using surface electrodes. The explanation of the theoretical basis for selecting these impedance values (Zc and Ro), to predict TBW and ECW is presented. Studies were conducted on a group of normal healthy animals, (n=42), in which TBW and ECW were determined by the gold standard of isotope dilution. The prediction quotients L2/Zc and L2/Ro, (L=length), yielded standard errors of 4.2% and 3.2% respectively, and were found to be significantly better than previously reported, empirically determined prediction quotients derived from measurements at a single frequency. The prediction equations established in this group of normal healthy animals were applied to a group of animals with abnormally low fluid levels, (n=20), and also to a group with an abnormal balance of extra-cellular to intracellular fluids, (n=20). In both cases the equations using L2/Zc and L2/Ro accurately and precisely predicted TBW and ECW. This demonstrated that the technique developed using multiple frequency bioelectrical impedance analysis, (MFBIA), can accurately predict both TBW and ECW in both normal and abnormal animals, (with standard errors of the estimate of 6% and 3% for TBW and ECW respectively). Isotope dilution techniques were used to determine TBW and ECW in a group of 60 healthy human subjects, (male. and female, aged between 18 and 45). Whole body impedance measurements were recorded on each subject using the MFBIA technique and the correlations between body water volumes, (TBW and ECW), and heighe/impedance, (for all measured frequencies), were compared. The prediction quotients H2/Zc and H2/Ro, (H=height), again yielded the highest correlation with TBW and ECW respectively with corresponding standard errors of 5.2% and 10%. The values of the correlation coefficients obtained in this study were very similar to those recently reported by others. It was also observed that in healthy human subjects the impedance measured at virtually any frequency yielded correlations not significantly different from those obtained from the MFBIA quotients. This phenomenon has been reported by other research groups and emphasises the need to validate the technique by investigating its application in one or more groups with abnormalities in fluid levels. The clinical application of MFBIA was trialled and its capability of detecting lymphoedema, (an excess of extracellular fluid), was investigated. The MFBIA technique was demonstrated to be significantly more sensitive, (P<.05), in detecting lymphoedema than the current technique of circumferential measurements. MFBIA was also shown to provide valuable information describing the changes in the quantity of muscle mass of the patient during the course of the treatment. The determination of body composition, (viz TBW and ECW), by MFBIA has been shown to be a significant improvement on previous bioelectrical impedance techniques. The merit of the MFBIA technique is evidenced in its accurate, precise and valid application in animal groups with a wide variation in body fluid volumes and balances. The multiple frequency bioelectrical impedance analysis technique developed in this study provides accurate and precise estimates of body composition, (viz TBW and ECW), regardless of the individual's state of health.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Various load compensation schemes proposed in literature assume that voltage source at point of common coupling (PCC) is stiff. In practice, however, the load is remote from a distribution substation and is supplied by a feeder. In the presence of feeder impedance, the PWM inverter switchings distort both the PCC voltage and the source currents. In this paper load compensation with such a non-stiff source is considered. A switching control of the voltage source inverter (VSI) based on state feedback is used for load compensation with non-stiff source. The design of the state feedback controller requires careful considerations in choosing a gain matrix and in the generation of reference quantities. These aspects are considered in this paper. Detailed simulation and experimental results are given to support the control design.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many of the power utilities around the world experienced spurious tripping of directional earth fault relays in their mesh distribution networks due to induced circulating currents. This circulating current is zero sequence and induced in the healthy circuit due to the zero sequence current flow resulting from a ground fault of a parallel circuit. This paper quantitatively discusses the effects of mutual coupling on earth fault protection of distribution systems. An actual spurious tripping event is analyzed to support the theory and to present options for improved resilience to spurious tripping.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To investigate the effects of hearing impairment and distractibility on older people's driving ability, assessed under real-world conditions. DESIGN: Experimental cross-sectional study. SETTING: University laboratory setting and an on-road driving test. PARTICIPANTS: One hundred seven community-living adults aged 62 to 88. Fifty-five percent had normal hearing, 26% had a mild hearing impairment, and 19% had a moderate or greater impairment. ---------- MEASUREMENTS: Hearing was assessed using objective impairment measures (pure-tone audiometry, speech perception testing) and a self-report measure (Hearing Handicap Inventory for the Elderly). Driving was assessed on a closed road circuit under three conditions: no distracters, auditory distracters, and visual distracters. RESULTS: There was a significant interaction between hearing impairment and distracters, such that people with moderate to severe hearing impairment had significantly poorer driving performance in the presence of distracters than those with normal or mild hearing impairment. CONCLUSION: Older adults with poor hearing have greater difficulty with driving in the presence of distracters than older adults with good hearing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using GIS to evaluate travel behaviour is an important technique to increase our understanding of the relationship between accessibility and transport demand. In this paper, the activity space concept was used to identify the nature of participation in activities (or lack of it) amongst a group of students using a 2 day travel-activity diary. Three different indicators such as the number of unique locations visited, average daily distance travelled, and average daily activity duration were used to measure the size of activity spaces. These indicators reflect levels of accessibility, personal mobility, and the extent of participation respectively. Multiple regression analyses were used to assess the impacts of students socio-economic status and the spatial characteristics of home location. Although no differences were found in the levels of accessibility and the extent of participation measures, home location with respect to a demand responsive transport (DRT) service was found to be the most important determinant of their mobility patterns. Despite being able to travel longer distances, students who live outside of the DRT service area were found to be temporally excluded from some opportunities. Student activity spaces were also visualised within a GIS environment and a spatial analysis was conducted to underpin the evaluation of the performance of the DRT. This approach was also used to identify the activity spaces of individuals that are geographically excluded from the service. Evaluation of these results indicated that although the service currently covers areas of high demand, 90% of the activity spaces remained un-served by the DRT service. Using this data six new routes were designed to meet the coverage goal of public transport based on a measure of network impedance based on inverse activity density. Following assessment of public transport service coverage, the study was extended using a Spatial Multi Criteria Evaluation (SMCE) technique to assess the effect of service provision on patronage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To examine the impact of different endotracheal tube (ETT) suction techniques on regional end-expiratory lung volume (EELV) and tidal volume (VT) in an animal model of surfactant-deficient lung injury. Methods: Six 2-week old piglets were intubated (4.0 mm ETT), muscle-relaxed and ventilated, and lung injury was induced with repeated saline lavage. In each animal, open suction (OS) and two methods of closed suction (CS) were performed in random order using both 5 and 8 French gauge (FG) catheters. The pre-suction volume state of the lung was standardised on the inflation limb of the pressure-volume relationship. Regional EELV and VT expressed as a proportion of the impedance change at vital capacity (%ZVCroi) within the anterior and posterior halves of the chest were measured during and for 60 s after suction using electrical impedance tomography. Results: During suction, 5 FG CS resulted in preservation of EELV in the anterior (nondependent) and posterior(dependent) lung compared to the other permutations, but these only reached significance in the anterior regions (p\0.001 repeated-measures ANOVA). VT within the anterior, but not posterior lung was significantly greater during 5FG CS compared to 8 FG CS; the mean difference was 15.1 [95% CI 5.1, 25.1]%ZVCroi. Neither catheter size nor suction technique influenced post-suction regional EELV or VT compared to pre-suction values (repeated-measures ANOVA). Conclusions: ETT suction causes transient loss of EELV and VT throughout the lung. Catheter size exerts a greater influence than suction method, with CS only protecting against derecruitment when a small catheter is used, especially in the non-dependent lung.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Bioimpedance techniques provide a reliable method of assessing unilateral lymphedema in a clinical setting. Bioimpedance devices are traditionally used to assess body composition at a current frequency of 50 kHz. However, these devices are not transferable to the assessment of lymphedema, as the sensitivity of measuring the impedance of extracellular fluid is frequency dependent. It has previously been shown that the best frequency to detect extracellular fluid is 0 kHz (or DC). However, measurement at this frequency is not possible in practice due to the high skin impedance at DC, and an estimate is usually determined from low frequency measurements. This study investigated the efficacy of various low frequency ranges for the detection of lymphedema. Methods and Results: Limb impedance was measured at 256 frequencies between 3 kHz and 1000 kHz for a sample control population, arm lymphedema population, and leg lymphedema population. Limb impedance was measured using the ImpediMed SFB7 and ImpediMed L-Dex® U400 with equipotential electrode placement on the wrists and ankles. The contralateral limb impedance ratio for arms and legs was used to calculate a lymphedema index (L-Dex) at each measurement frequency. The standard deviation of the limb impedance ratio in a healthy control population has been shown to increase with frequency for both the arm and leg. Box and whisker plots of the spread of the control and lymphedema populations show that there exists good differentiation between the arm and leg L-Dex measured for lymphedema subjects and the arm and leg L-Dex measured for control subjects up to a frequency of about 30 kHz. Conclusions: It can be concluded that impedance measurements above a frequency of 30 kHz decrease sensitivity to extracellular fluid and are not reliable for early detection of lymphedema.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: High-flow nasal cannulae (HFNC) create positive oropharyngeal airway pressure but it is unclear how their use affects lung volume. Electrical impedance tomography (EIT) allows assessment of changes in lung volume by measuring changes in lung impedance. Primary objectives were to investigate the effects of HFNC on airway pressure (Paw) and end-expiratory lung volume (EELV), and to identify any correlation between the two. Secondary objectives were to investigate the effects of HFNC on respiratory rate (RR), dyspnoea, tidal volume and oxygenation; and the interaction between body mass index (BMI) and EELV. Methods: Twenty patients prescribed HFNC post-cardiac surgery were investigated. Impedance measures, Paw, PaO2/FiO2 ratio, RR and modified Borg scores were recorded first on low flow oxygen (nasal cannula or Hudson face mask) and then on HFNC. Results: A strong and significant correlation existed between Paw and end-expiratory lung impedance (EELI) (r=0.7, p<0.001). Compared with low flow oxygen, HFNC significantly increased EELI by 25.6% (95% CI 24.3, 26.9) and Paw by 3.0 cmH2O (95% CI 2.4, 3.7). RR reduced by 3.4 breaths per minute (95% CI 1.7, 5.2) with HFNC use, tidal impedance variation increased by 10.5% (95% CI 6.1, 18.3) and PaO2/FiO2 ratio improved by 30.6 mmHg (95% CI 17.9, 43.3). HFNC improved subjective dyspnoea scoring (p=0.023). Increases in EELI were significantly influenced by BMI, with larger increases associated with higher BMIs (p<0.001). Conclusions: This study suggests that HFNC improve dyspnoea and oxygenation by increasing both EELV and tidal volume, and are most beneficial in patients with higher BMIs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The performance and electron recombination kinetics of dye-sensitized solar cells based on TiO2 films consisting of one-dimensional nanorod arrays (NR-DSSCs) which are sensitized with dye N719, C218 and D205 respectively have been studied. It has been found that the best efficiency is obtained with the dye C218 based NR-DSSCs, benefiting from a 40% higher short-circuit photocurrent density. However, the open circuit photovoltage of the N719 based cell is 40 mV higher than that of the organic dye C218 and D205 based devices. Investigation of the electron recombination kinetics of the NR-DSSCs has revealed that the effective electron lifetime, τn, of the N719 based NR-DSSC is the lowest whereas the τn of the C218 based NR-DSSC is the highest among the three dyes. The higher Voc with the N719 based NR-DSSC is originated from the more negative energy level of the conduction band of the TiO2 film. In addition, in comparison to the DSSCs with conventional nanocrystalline particles based TiO2 films, the NR-DSSCs have shown over two orders of magnitude higher τn when employing N719 as the sensitizer. Nevertheless, the τn of the DSSCs with the C218 based nanorod arrays is only ten-fold higher than the that of the nanoparticles based devices. The remarkable characteristic of the dye C218 in suppressing the electron recombination of DSSCs is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Obesity is a major public health problem in both developed and developing countries. The body mass index (BMI) is the most common index used to define obesity. The universal application of the same BMI classification across different ethnic groups is being challenged due to the inability of the index to differentiate fat mass (FM) and fat�]free mass (FFM) and the recognized ethnic differences in body composition. A better understanding of the body composition of Asian children from different backgrounds would help to better understand the obesity�]related health risks of people in this region. Moreover, the limitations of the BMI underscore the necessity to use where possible, more accurate measures of body fat assessment in research and clinical settings in addition to BMI, particularly in relation to the monitoring of prevention and treatment efforts. The aim of the first study was to determine the ethnic difference in the relationship between BMI and percent body fat (%BF) in pre�]pubertal Asian children from China, Lebanon, Malaysia, the Philippines, and Thailand. A total of 1039 children aged 8�]10 y were recruited using a non�]random purposive sampling approach aiming to encompass a wide BMI range from the five countries. Percent body fat (%BF) was determined using the deuterium dilution technique to quantify total body water (TBW) and subsequently derive proportions of FM and FFM. The study highlighted the sex and ethnic differences between BMI and %BF in Asian children from different countries. Girls had approximately 4.0% higher %BF compared with boys at a given BMI. Filipino boys tended to have a lower %BF than their Chinese, Lebanese, Malay and Thai counterparts at the same age and BMI level (corrected mean %BF was 25.7�}0.8%, 27.4�}0.4%, 27.1�}0.6%, 27.7�}0.5%, 28.1�}0.5% for Filipino, Chinese, Lebanese, Malay and Thai boys, respectively), although they differed significantly from Thai and Malay boys. Thai girls had approximately 2.0% higher %BF values than Chinese, Lebanese, Filipino and Malay counterparts (however no significant difference was seen among the four ethnic groups) at a given BMI (corrected mean %BF was 31.1�}0.5%, 28.6�}0.4%, 29.2�}0.6%, 29.5�}0.6%, 29.5�}0.5% for Thai, Chinese, Lebanese, Malay and Filipino girls, respectively). However, the ethnic difference in BMI�]%BF relationship varied by BMI. Compared with Caucasians, Asian children had a BMI 3�]6 units lower for a given %BF. More than one third of obese Asian children in the study were not identified using the WHO classification and more than half were not identified using the International Obesity Task Force (IOTF) classification. However, use of the Chinese classification increased the sensitivity by 19.7%, 18.1%, 2.3%, 2.3%, and 11.3% for Chinese, Lebanese, Malay, Filipino and Thai girls, respectively. A further aim of the first study was to determine the ethnic difference in body fat distribution in pre�]pubertal Asian children from China, Lebanon, Malaysia, and Thailand. The skin fold thicknesses, height, weight, waist circumference (WC) and total adiposity (as determined by deuterium dilution technique) of 922 children from the four countries was assessed. Chinese boys and girls had a similar trunk�]to�]extremity skin fold thickness ratio to Thai counterparts and both groups had higher ratios than the Malays and Lebanese at a given total FM. At a given BMI, both Chinese and Thai boys and girls had a higher WC than Malays and Lebanese (corrected mean WC was 68.1�}0.2 cm, 67.8�}0.3 cm, 65.8�}0.4 cm, 64.1�}0.3 cm for Chinese, Thai, Lebanese and Malay boys, respectively; 64.2�}0.2 cm, 65.0�}0.3 cm, 62.9�}0.4 cm, 60.6�}0.3 cm for Chinese, Thai, Lebanese and Malay girls, respectively). Chinese boys and girls had lower trunk fat adjusted subscapular/suprailiac skinfold ratio compared with Lebanese and Malay counterparts. The second study aimed to develop and cross�]validate bioelectrical impedance analysis (BIA) prediction equations of TBW and FFM for Asian pre�]pubertal children from China, Lebanon, Malaysia, the Philippines, and Thailand. Data on height, weight, age, gender, resistance and reactance measured by BIA were collected from 948 Asian children (492 boys and 456 girls) aged 8�]10 y from the five countries. The deuterium dilution technique was used as the criterion method for the estimation of TBW and FFM. The BIA equations were developed from the validation group (630 children randomly selected from the total sample) using stepwise multiple regression analysis and cross�]validated in a separate group (318 children) using the Bland�]Altman approach. Age, gender and ethnicity influenced the relationship between the resistance index (RI = height2/resistance), TBW and FFM. The BIA prediction equation for the estimation of TBW was: TBW (kg) = 0.231�~Height2 (cm)/resistance (ƒ¶) + 0.066�~Height (cm) + 0.188�~Weight (kg) + 0.128�~Age (yr) + 0.500�~Sex (male=1, female=0) . 0.316�~Ethnicity (Thai ethnicity=1, others=0) �] 4.574, and for the estimation of FFM: FFM (kg) = 0.299�~Height2 (cm)/resistance (ƒ¶) + 0.086�~Height (cm) + 0.245�~Weight (kg) + 0.260�~Age (yr) + 0.901�~Sex (male=1, female=0) �] 0.415�~Ethnicity (Thai ethnicity=1, others=0) �] 6.952. The R2 was 88.0% (root mean square error, RSME = 1.3 kg), 88.3% (RSME = 1.7 kg) for TBW and FFM equation, respectively. No significant difference between measured and predicted TBW and between measured and predicted FFM for the whole cross�]validation sample was found (bias = �]0.1�}1.4 kg, pure error = 1.4�}2.0 kg for TBW and bias = �]0.2�}1.9 kg, pure error = 1.8�}2.6 kg for FFM). However, the prediction equation for estimation of TBW/FFM tended to overestimate TBW/FFM at lower levels while underestimate at higher levels of TBW/FFM. Accuracy of the general equation for TBW and FFM compared favorably with both BMI�]specific and ethnic�]specific equations. There were significant differences between predicted TBW and FFM from external BIA equations derived from Caucasian populations and measured values in Asian children. There were three specific aims of the third study. The first was to explore the relationship between obesity and metabolic syndrome and abnormalities in Chinese children. A total of 608 boys and 800 girls aged 6�]12 y were recruited from four cities in China. Three definitions of pediatric metabolic syndrome and abnormalities were used, including the International Diabetes Federation (IDF) and National Cholesterol Education Program (NCEP) definition for adults modified by Cook et al. and de Ferranti et al. The prevalence of metabolic syndrome varied with different definitions, was highest using the de Ferranti definition (5.4%, 24.6% and 42.0%, respectively for normal�]weight, overweight and obese children), followed by the Cook definition (1.5%, 8.1%, and 25.1%, respectively), and the IDF definition (0.5%, 1.8% and 8.3%, respectively). Overweight and obese children had a higher risk of developing the metabolic syndrome compared to normal�]weight children (odds ratio varied with different definitions from 3.958 to 6.866 for overweight children, and 12.640�]26.007 for obese children). Overweight and obesity also increased the risk of developing metabolic abnormalities. Central obesity and high triglycerides (TG) were the most common while hyperglycemia was the least frequent in Chinese children regardless of different definitions. The second purpose was to determine the best obesity index for the prediction of cardiovascular (CV) risk factor clustering across a 2�]y follow�]up among BMI, %BF, WC and waist�]to�]height ratio (WHtR) in Chinese children. Height, weight, WC, %BF as determined by BIA, blood pressure, TG, high�]density lipoprotein cholesterol (HDL�]C), and fasting glucose were collected at baseline and 2 years later in 292 boys and 277 girls aged 8�]10 y. The results showed the percentage of children who remained overweight/obese defined on the basis of BMI, WC, WHtR and %BF was 89.7%, 93.5%, 84.5%, and 80.4%, respectively after 2 years. Obesity indices at baseline significantly correlated with TG, HDL�]C, and blood pressure at both baseline and 2 years later with a similar strength of correlations. BMI at baseline explained the greatest variance of later blood pressure. WC at baseline explained the greatest variance of later HDL�]C and glucose, while WHtR at baseline was the main predictor of later TG. Receiver�]operating characteristic (ROC) analysis explored the ability of the four indices to identify the later presence of CV risk. The overweight/obese children defined on the basis of BMI, WC, WHtR or %BF were more likely to develop CV risk 2 years later with relative risk (RR) scores of 3.670, 3.762, 2.767, and 2.804, respectively. The final purpose of the third study was to develop age�] and gender�]specific percentiles of WC and WHtR and cut�]off points of WC and WHtR for the prediction of CV risk in Chinese children. Smoothed percentile curves of WC and WHtR were produced in 2830 boys and 2699 girls aged 6�]12 y randomly selected from southern and northern China using the LMS method. The optimal age�] and gender�]specific thresholds of WC and WHtR for the prediction of cardiovascular risk factors clustering were derived in a sub�]sample (n=1845) by ROC analysis. Age�] and gender�]specific WC and WHtR percentiles were constructed. The WC thresholds were at the 90th and 84th percentiles for Chinese boys and girls, respectively, with sensitivity and specificity ranging from 67.2% to 83.3%. The WHtR thresholds were at the 91st and 94th percentiles for Chinese boys and girls, respectively, with sensitivity and specificity ranging from 78.6% to 88.9%. The cut�]offs of both WC and WHtR were age�] and gender�]dependent. In conclusion, the current thesis quantifies the ethnic differences in the BMI�]%BF relationship and body fat distribution between Asian children from different origins and confirms the necessity to consider ethnic differences in body composition when developing BMI and other obesity index criteria for obesity in Asian children. Moreover, ethnicity is also important in BIA prediction equations. In addition, WC and WHtR percentiles and thresholds for the prediction of CV risk in Chinese children differ from other populations. Although there was no advantage of WC or WHtR over BMI or %BF in the prediction of CV risk, obese children had a higher risk of developing the metabolic syndrome and abnormalities than normal�]weight children regardless of the obesity index used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the design and implementation of a microstrip to parallel strip balun which are frequently used as balanced antennas feed. This wideband balun transition is composed of a parallel strip which is connected to the spiral antenna and a microstrip line where the width of the ground plane is gradually reduced to eventually resemble the parallel strip. The taper accomplishes the mode and impedance transformation. This balun has significantly improved bandwidth characteristics. The entire circuit was fabricated on RT Duriod 5880 substrate. The circuit designs were simulated and optimised using CST Microwave Studio and the simulated results are compared with the measured results. The back-to-back microstrip to parallel strip has a return loss of better than 10 dB over a wide bandwidth from 1.75 to 15 GHz. The performance of the proposed balun was validated with the spiral antenna. The measured results were compared with the simulated results and it shows that the antenna operates well in wideband frequency range from 2.5 to 15 GHz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The small element spacing of compact multiport arrays introduces strong mutual coupling between the antenna ports. Due to this coupling, the input impedance of the array changes when elements excitations are varied, and consequently, the array cannot be matched for an arbitrary excitation. Decoupling networks have in the past been used to provide an additional connection between antenna ports in order to cancel the coupling between elements. An alternative approach is to design the antenna so that each port does not excite a single element, but all elements simultaneously instead. The geometry of the antenna is optimized so that this direct excitation of elements counteracts the mutual coupling, thus yielding decoupled ports. This paper describes the design of such a 4-port antenna.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A modified microstrip-fed planar monopole antenna with open circuited coupled line is presented in this paper. The operational bandwidth of the proposed antenna covers the 2.4 GHz ISM band (2.42-2.48 GHz) and the 5 GHz WLAN band (5 GHz to 6 GHz). The radiating elements occupy a small area of 23×8 mm2. The Finite Difference Time Domain method is used to predict the input impedance of the antenna. The calculated return loss shows very good agreement with measured data. Reasonable antenna gain is observed across the operating band. The measured radiation patterns are similar to those of a simple monopole antenna.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel reduced-size microstrip rectangular patch antenna for Bluetooth operation is presented in this paper. The proposed antenna operates in the 2400 to 2484 MHz ISM Band. Although an air substrate is introduced, antenna occupies a small volume of 33.3×6.6×0.8 mm3. The gain and the impedance bandwidth of the antenna are predicted using a commercial Finite Element Method software package. The predicted results show good agreement with measured data.