204 resultados para disposable contact lenses


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Contact lenses are a successful and popular means to correct refractive error and are worn by just under 700,000 Australians1 and approximately 125 million people worldwide. The most serious complication of contact lens wear is microbial keratitis, a potentially sight-threatening corneal infection most often caused by bacteria. Gram-negative bacteria, in particular pseudomonas species, account for the majority of severe bacterial infections. Pathogens such as fungi or amoebae, which feature less often, are associated with significant morbidity. These unusual pathogens have come into the spotlight in recent times with an apparent association with specific lens cleaning solutions...

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The contact lens industry has evolved and now provides many choices, including continuous wear, overnight orthokeratology, frequent-replacement lenses, daily-disposable lenses, and many alternatives in systems of care and maintenance. Epidemiologic studies to date have shown that how a lens is worn, particularly if worn overnight, can increase the risk of microbial keratitis. However, the risk of silicone hydrogel contact lenses worn on a continuous-wear basis has been evaluated only recently. This article summarizes the recent research data on extended-wear silicone hydrogel lenses and discusses the challenges of early evaluations of silicone hydrogel lens safety. Finally, the relevance of this information is discussed to practitioners and contact lens wearers making choices about the risks and benefits of different products and how they are used.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The 12th annual survey of Australian contact lens prescribing was conducted between January and April 2011, employing the same format as in previous years. About 3,000 optometrist members of Optometrists Association Australia were sent an e-mail message with a link to a downloadable questionnaire, and a request that this be accessed, printed and completed to provide details of the first 10 patients fitted with contact lenses after receipt of the questionnaire.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Silicone hydrogel (SiH) contact lenses have been available for over a decade. During that time, these highly innovative materials and designs have continually improved and now represent a major percentage of fits within the global contact lens market.1 Their high oxygen transmissibility has drastically reduced the incidence of hypoxia-related conditions such as corneal edema, limbal hyperaemia, and corneal vascularisation.2,3 However, there remain significant challenges in the quest for the ideal contact lens. The silicone material used in SiH contact lenses is inherently more hydrophobic than the non-silicone hydrogel materials. SiH lens manufacturers must find ways to overcome lens surface hydrophobicity since it can create issues in terms of lens wettability and surface deposition. Achieving ideal lens water content presents yet another challenge since increasing water content in a silicone hydrogel lens can reduce oxygen transmissibility. This is because increasing water content results in decreased silicone content in the lens and silicone is a better transmitter of oxygen than water.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Along with other facets of commericialization, the contact lens market has become globalized during the past 30 years. The major international companies have worldwide distribution networks and supply lenses of the same product names and replacement frequencies to all nations, with a few minor adjustments for marketing and regulatory reasons. Small and medium-sized companies, often producing more specialized lenses, are also active in markets across the world.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

For the past 12 years, the International Contact Lens Prescribing Survey Consortium has sent surveys to a selection of Canadian optometrists in order to collect information on the contact lenses they fit and basic demographic data of the patients. Canada is one of about 40 countries that contributes to the global study and while annual reviews of the study data are presented, information published for any one market is limited due to the size of the dataset.1 This manuscript presents a more detailed analysis on the Canadian market for 2011.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The 13th annual survey of Australian contact lens prescribing was conducted between January and April 2012. The same format as in previous years was employed. About 3,000 members of Optometrists Association Australia were sent an e-mail message with a link to a downloadable questionnaire, and a request that this be accessed, printed and completed to provide details of the first 10 patients fitted with contact lenses after receipt of the questionnaire.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

New technologies for examination of the anterior eye in contact lens practice don’t appear to have taken a huge leap in the past decade however there a several novel adaptations of existing technology worthy of note. In other areas of health we have self-diagnosis via smartphone or other gadgets adapted as medical devices. In practice and research in vitro and in vivo new adaptive technologies have expanded our capabilities in assessing the anterior eye, in particular corneal and conjunctival confocal microscopy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE. To examine the deposition of tear phospholipids and cholesterol onto worn contact lenses and the effect of lens material and lens care solution. METHODS. Lipids were extracted from tears and worn contact lenses using 2:1 chloroform: Methanol and the extract washed with aqueous ammonium acetate, before analysis by electrospray ionization tandem mass spectrometry (ESI-MS/MS). RESULTS. Twenty-three molecular lipids from the sphingomyelin (SM) and phosphatidylcholine (PC) classes were detected in tears, with total concentrations of each class determined to be 5 ± 1 pmol/μL (~3.8 μg/mL) and 6 ± 1 pmol/μL (~ 4.6μg/mL), respectively. The profile of individual phospholipids in both of these classes was shown to be similar in contact lens deposits. Deposition of representative polar and nonpolar lipids were shown to be significantly higher on senofilcon A contact lenses, with ~59 ng/lens SM, 195 ng/lens PC, and 9.9 μg/lens cholesterol detected, whereas balafilcon A lens extracts contained ~19 ng/lens SM, 19 ng/lens PC, and 3.9 μg/lens cholesterol. Extracts from lenses disinfected and cleaned with two lens care solutions showed no significant differences in total PC and SM concentrations; however, a greater proportion of PC than SM was observed, compared with that in tears. CONCLUSIONS. Phospholipid deposits extracted from worn contact lenses show a molecular profile similar to that in tears. The concentration of representative polar and nonpolar lipids deposited onto contact lenses is significantly affected by lens composition. There is a differential efficacy in the removal of PC and SM with lens care solutions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background A population-based, cross-sectional telephone survey was conducted to estimate the penetrance and characteristics of contact lens wear in Australia. Methods Based on postcode distribution, 42,749 households around Australia were randomly selected from the national electronic telephone directory. During calls, the number of individuals and contact lens wearers in each household aged between 15 and 64 years was ascertained. Contact lens wearers were interviewed using a structured questionnaire, to determine details of demographics, lens type, mode of lens wear and hygienic habits. Contact lens wear characteristics and habits were compared by lens type and mode of use. Results Of the 32,405 households contacted, 19,171 (59.2 per cent) agreed to participate. The penetrance of contact lens wear during the study period was 5.01 per cent (95% CI: 4.78-5.24). The mean age of lens wearers was 36.5 ± 18.3 years and 63.4 per cent were female. There were significant differences in the habits and characteristics of lens wearers depending on their lens type and mode of use. Conclusions The penetrance of contact lens wear concurs with market estimates and equates to approximately 680,000 contact lens wearers aged between 15 and 64 years in Australia. This is the most detailed and extensive population-based survey of contact lens wearers ever conducted. The discrepancies found between the characteristics of lens wearers surveyed in this study compared to those in previous studies of contact lens practitioners highlights the importance of study design. These results may be applied to other regions with similar health-care and regulatory systems.

Relevância:

90.00% 90.00%

Publicador:

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose To examine the influence of short-term miniscleral contact lens wear on corneal shape, thickness and anterior surface aberrations. Methods Scheimpflug imaging was captured before, immediately following and 3 hours after a short period (3 hours) of miniscleral contact lens wear for 10 young (mean 27 ± 5 years), healthy participants. Natural diurnal variations were considered by measuring baseline diurnal changes obtained on a separate control day without contact lens wear. Results Small but significant anterior corneal flattening was observed immediately following lens removal (overall mean 0.02 ± 0.03 mm, p < 0.001) which returned to baseline levels three hours after lens removal. During the three hour recovery period significant corneal thinning (-13.4 ± 10.5 μm) and posterior surface flattening (0.03 ± 0.02 mm) were also observed (both p < 0.01). The magnitude of posterior corneal flattening during recovery correlated with the amount of corneal thinning (r = 0.69, p = 0.03). Central corneal clearance (maximum tear reservoir depth) was not associated with corneal swelling following lens removal (r = -0.24, p > 0.05). An increase in lower-order corneal astigmatism Z(2,2) was also observed following lens wear (mean -0.144 ± 0.075 μm, p = 0.02). Conclusions Flattening of the anterior corneal surface was observed immediately following lens wear, while ‘rebound’ thinning and flattening of the posterior surface was evident following the recovery period. Modern miniscleral contact lenses that vault the cornea may slightly influence corneal shape and power but do not induce clinically significant corneal oedema during short-term wear.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Donald Ezekiel (known to all as ‘Don’) was born in Singapore on September 12, 1936, to a German mother and Iraqi father. His parents were Jewish refugees, who met in Batavia,1 married and alternately lived in Batavia and Singapore. The family established their primary residence in Singapore after Don’s older brother Eric (later to become a haematologist) was born in 1934. The Ezekiel family was forced to flee in 1941 when the Japanese bombed Singapore and were fortunate to obtain passage on a hospital ship to Perth. They returned to Singapore after the war but left again on their own accord in 1951 due to race riots. The Ezekiels sold up everything in Singapore and decided to settle in Perth...