186 resultados para biometria ocular


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the limits at which blur due to defocus, crossed-cylinder astigmatism, and trefoil became noticeable, troublesome or objectionable. Black letter targets (0.1, 0.35 and 0.6 logMAR) were presented on white backgrounds. Subjects were cyclopleged and had effectively 5 mm pupils. Blur was induced with a deformable, adaptive-optics mirror operating under open-loop conditions. Mean defocus blur limits of six subjects with uncorrected intrinsic higher-order ocular aberrations ranged from 0.18 ± 0.08 D (noticeable blur criterion, 0.1 logMAR) to 1.01 ± 0.27 D (objectionable blur criterion, 0.6 logMAR. Crossed-cylinder astigmatic blur limits were approximately 90% of those for defocus, but with considerable meridional influences. In two of the subjects, the intrinsic aberrations of the eye were subsequently corrected before the defocus and astigmatic blur were added. This resulted in only minor reductions in their blur limits. When assessed with trefoil blur and corrected intrinsic ocular aberrations, the ratio of objectionable to noticeable blur limits in these two subjects was much higher for trefoil (3.5) than for defocus (2.5) and astigmatism (2.2).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the effect of orthokeratology on peripheral aberrations in two myopic volunteers. Methods: The subjects wore reverse geometry orthokeratology lenses overnight and were monitored for 2 weeks of wear. They underwent corneal topography, peripheral refraction (out to ±34° along the horizontal visual field) and peripheral aberration measurements across the 42° × 32° central visual field using a modified Hartmann-Shack aberrometer. Results: Spherical equivalent refraction was corrected for the central 25° of the visual fields beyond which it gradually returned to its preorthokeratology values. There were increases in axial coma, spherical aberration, higher order root mean square aberrations, and total root-mean-squared aberrations (excluding defocus). The rates of change of vertical and horizontal coma across the field changed in sign. Total root mean square aberrations showed a quadratic rate of change across the visual field which was greater subsequent to orthokeratology. Conclusion: Although orthokeratology can correct peripheral relative hypermetropia it induces dramatic increases in higher-order aberrations across the field

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate associations between the diurnal variation in a range of corneal parameters, including anterior and posterior corneal topography, and regional corneal thickness. ----- Methods: Fifteen subjects had their corneas measured using a rotating Scheimpflug camera (Pentacam) every 3-7 hours over a 24-hour period. Anterior and posterior corneal axial curvature, pachymetry and anterior chamber depth were analysed. The best fitting corneal sphero-cylinder from the axial curvature, and the average corneal thickness for a series of different corneal regions were calculated. Intraocular pressure and axial length were also measured at each measurement session. Repeated measures ANOVA were used to investigate diurnal change in these parameters. Analysis of covariance was used to examine associations between the measured ocular parameters. ----- Results: Significant diurnal variation was found to occur in both the anterior and posterior corneal curvature and in the regional corneal thickness. Flattening of the anterior corneal best sphere was observed at the early morning measurement (p < 0.0001). The posterior cornea also underwent a significant steepening (p < 0.0001) and change in astigmatism 90/180° at this time. A significant swelling of the cornea (p < 0.0001) was also found to occur immediately after waking. Highly significant associations were found between the diurnal variation in corneal thickness and the changes in corneal curvature. ----- Conclusions: Significant diurnal variation occurs in the regional thickness and the shape of the anterior and posterior cornea. The largest changes in the cornea were typically evident upon waking. The observed non-uniform regional corneal thickness changes resulted in a steepening of the posterior cornea, and a flattening of the anterior cornea to occur at this time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two different methods to measure binocular longitudinal corneal apex movements were synchronously applied. High-speed videokeratoscopy at a sampling frequency of 15 Hz and a customdesigned ultrasound distance sensor at 100 Hz were used for the left and the right eye, respectively. Four healthy subjects participated in the study. Simultaneously, cardiac electric cycle (ECG) was registered for each subject at 100 Hz. Each measurement took 20 s. Subjects were asked to suppress blinking during the measurements. A rigid headrest and a bite-bar were used to minimize undesirable head movements. Time, frequency and time-frequency representations of the acquired signals were obtained to establish their temporal and spectral contents. Coherence analysis was used to estimate the correlation between the measured signals. The results showed close correlation between both corneal apex movements and the cardiopulmonary system. Unraveling these relationships could lead to better understanding of interactions between ocular biomechanics and vision. The advantages and disadvantages of the two methods in the context of measuring longitudinal movements of the corneal apex are outlined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to characterize the clinical signs, symptoms, and ocular and systemic comorbidities in a large case series of contact lens-related microbial keratitis. Methods: Two hundred ninety-seven cases of contact lens-related microbial keratitis, aged between 15 and 64 years were detected through surveillance of hospital and community based ophthalmic practitioners in Australia and New Zealand. Full clinical data were available for 190 cases and 90 were interviewed by telephone. Clinical data included the size, location, and degree of anterior chamber response. Symptom data were available from the practitioner and from participant self-report. Associations between symptoms and disease severity were evaluated. Data on ocular and systemic disease were collected from participants and practitioners. The frequency of comorbidities was compared between the different severities of disease and to population norms. Results: More severe disease was associated with greater symptom severity and pain was the most prevalent symptom reported. Ninety-one percent of cases showed progression of ocular symptoms after lens removal, and symptom progression was associated with all severities of disease. Twenty-five percent of cases reported prior episodes requiring emergency attention. Thyroid disease (p 0.05) and self-reported poor health (p 0.001) were more common in cases compared with age-matched population norms. Discussion: Information on the signs, symptoms, and comorbidities associated with contact lens-related microbial keratitis may be useful in patient education and for practitioners involved in the fitting of lenses and management of complications. Although pain was the most common symptom experienced, progression of symptoms despite lens removal was close to universal. Poor general health, particularly respiratory disease and thyroid disease was more common in cases than in the general population, which may prompt practitioners to recommend flexibility in wear schedules when in poor health or the selection of a lower risk wear schedule in at risk patients

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The eyelids play an important role in lubricating and protecting the surface of the eye. Each blink serves to spread fresh tears, remove debris and replenish the smooth optical surface of the eye. Yet little is known about how the eyelids contact the ocular surface and what pressure distribution exists between the eyelids and cornea. As the principal refractive component of the eye, the cornea is a major element of the eye’s optics. The optical properties of the cornea are known to be susceptible to the pressure exerted by the eyelids. Abnormal eyelids, due to disease, have altered pressure on the ocular surface due to changes in the shape, thickness or position of the eyelids. Normal eyelids also cause corneal distortions that are most often noticed when they are resting closer to the corneal centre (for example during reading). There were many reports of monocular diplopia after reading due to corneal distortion, but prior to videokeratoscopes these localised changes could not be measured. This thesis has measured the influence of eyelid pressure on the cornea after short-term near tasks and techniques were developed to quantify eyelid pressure and its distribution. The profile of the wave-like eyelid-induced corneal changes and the refractive effects of these distortions were investigated. Corneal topography changes due to both the upper and lower eyelids were measured for four tasks involving two angles of vertical downward gaze (20° and 40°) and two near work tasks (reading and steady fixation). After examining the depth and shape of the corneal changes, conclusions were reached regarding the magnitude and distribution of upper and lower eyelid pressure for these task conditions. The degree of downward gaze appears to alter the upper eyelid pressure on the cornea, with deeper changes occurring after greater angles of downward gaze. Although the lower eyelid was further from the corneal centre in large angles of downward gaze, its effect on the cornea was greater than that of the upper eyelid. Eyelid tilt, curvature, and position were found to be influential in the magnitude of eyelid-induced corneal changes. Refractively these corneal changes are clinically and optically significant with mean spherical and astigmatic changes of about 0.25 D after only 15 minutes of downward gaze (40° reading and steady fixation conditions). Due to the magnitude of these changes, eyelid pressure in downward gaze offers a possible explanation for some of the day-to-day variation observed in refraction. Considering the magnitude of these changes and previous work on their regression, it is recommended that sustained tasks performed in downward gaze should be avoided for at least 30 minutes before corneal and refractive assessment requiring high accuracy. Novel procedures were developed to use a thin (0.17 mm) tactile piezoresistive pressure sensor mounted on a rigid contact lens to measure eyelid pressure. A hydrostatic calibration system was constructed to convert raw digital output of the sensors to actual pressure units. Conditioning the sensor prior to use regulated the measurement response and sensor output was found to stabilise about 10 seconds after loading. The influences of various external factors on sensor output were studied. While the sensor output drifted slightly over several hours, it was not significant over the measurement time of 30 seconds used for eyelid pressure, as long as the length of the calibration and measurement recordings were matched. The error associated with calibrating at room temperature but measuring at ocular surface temperature led to a very small overestimation of pressure. To optimally position the sensor-contact lens combination under the eyelid margin, an in vivo measurement apparatus was constructed. Using this system, eyelid pressure increases were observed when the upper eyelid was placed on the sensor and a significant increase was apparent when the eyelid pressure was increased by pulling the upper eyelid tighter against the eye. For a group of young adult subjects, upper eyelid pressure was measured using this piezoresistive sensor system. Three models of contact between the eyelid and ocular surface were used to calibrate the pressure readings. The first model assumed contact between the eyelid and pressure sensor over more than the pressure cell width of 1.14 mm. Using thin pressure sensitive carbon paper placed under the eyelid, a contact imprint was measured and this width used for the second model of contact. Lastly as Marx’s line has been implicated as the region of contact with the ocular surface, its width was measured and used as the region of contact for the third model. The mean eyelid pressures calculated using these three models for the group of young subjects were 3.8 ± 0.7 mmHg (whole cell), 8.0 ± 3.4 mmHg (imprint width) and 55 ± 26 mmHg (Marx’s line). The carbon imprints using Pressurex-micro confirmed previous suggestions that a band of the eyelid margin has primary contact with the ocular surface and provided the best estimate of the contact region and hence eyelid pressure. Although it is difficult to directly compare the results with previous eyelid pressure measurement attempts, the eyelid pressure calculated using this model was slightly higher than previous manometer measurements but showed good agreement with the eyelid force estimated using an eyelid tensiometer. The work described in this thesis has shown that the eyelids have a significant influence on corneal shape, even after short-term tasks (15 minutes). Instrumentation was developed using piezoresistive sensors to measure eyelid pressure. Measurements for the upper eyelid combined with estimates of the contact region between the cornea and the eyelid enabled quantification of the upper eyelid pressure for a group of young adult subjects. These techniques will allow further investigation of the interaction between the eyelids and the surface of the eye.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: First-eye cataract surgery can reduce the rate of falls among older adults, yet the effect of second-eye surgery on the rate of falling remains unclear. The present study investigated the effect of monocular and binocular simulated cataract blur on postural stability among older adults. Methods: Postural stability was assessed on 34 healthy older adults (mean 68.2 years, SD 3.5) with normal vision, using a portable force platform (BT4, HUR Labs, Finland) which collected data on centre of pressure (COP) displacement. Stability was assessed on firm and foam surfaces under four binocular viewing conditions using Vistech filters to simulate cataract blur: [1] best-corrected vision both eyes; [2] blur over non-dominant eye, [3] blur over dominant eye and [4] blur over both eyes. Binocular logMAR visual acuity, Pelli-Robson contrast sensitivity and stereoacuity were also measured under these viewing conditions and ocular dominance measured using the hole-in-card test. Generalized estimating equations with an exchangeable correlation structure examined the effect of the surface and vision conditions on postural stability. Results: Visual acuity and contrast sensitivity were significantly reduced under monocular and binocular cataract blur compared to normal viewing. All blur conditions resulted in loss of stereoacuity. Binocular cataract blur significantly reduced postural stability compared to normal vision on the firm (COP path length; p=0.013) and foam surface (anterior-posterior COP RMS, COP path length and COP area; p<0.01). However, no significant differences in postural stability were found between the monocular blur conditions compared to normal vision, or between the dominant and non-dominant monocular blur conditions on either the firm or foam surfaces. Conclusions: Findings indicate that binocular blur significantly impairs postural stability, and suggests that improvements in postural stability may justify first-eye cataract surgery, particularly during somatosensory disruption. Postural stability was not significantly impaired in the monocular cataract blur conditions compared to the normal vision condition, nor was there any effect of ocular dominance on postural stability in the presence of monocular cataract blur.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study is the first to investigate the effect of prolonged reading on reading performance and visual functions in students with low vision. The study focuses on one of the most common modes of achieving adequate magnification for reading by students with low vision, their close reading distance (proximal or relative distance magnification). Close reading distances impose high demands on near visual functions, such as accommodation and convergence. Previous research on accommodation in children with low vision shows that their accommodative responses are reduced compared to normal vision. In addition, there is an increased lag of accommodation for higher stimulus levels as may occur at close reading distance. Reduced accommodative responses in low vision and higher lag of accommodation at close reading distances together could impact on reading performance of students with low vision especially during prolonged reading tasks. The presence of convergence anomalies could further affect reading performance. Therefore, the aims of the present study were 1) To investigate the effect of prolonged reading on reading performance in students with low vision 2) To investigate the effect of prolonged reading on visual functions in students with low vision. This study was conducted as cross-sectional research on 42 students with low vision and a comparison group of 20 students with normal vision, aged 7 to 20 years. The students with low vision had vision impairments arising from a range of causes and represented a typical group of students with low vision, with no significant developmental delays, attending school in Brisbane, Australia. All participants underwent a battery of clinical tests before and after a prolonged reading task. An initial reading-specific history and pre-task measurements that included Bailey-Lovie distance and near visual acuities, Pelli-Robson contrast sensitivity, ocular deviations, sensory fusion, ocular motility, near point of accommodation (pull-away method), accuracy of accommodation (Monocular Estimation Method (MEM)) retinoscopy and Near Point of Convergence (NPC) (push-up method) were recorded for all participants. Reading performance measures were Maximum Oral Reading Rates (MORR), Near Text Visual Acuity (NTVA) and acuity reserves using Bailey-Lovie text charts. Symptoms of visual fatigue were assessed using the Convergence Insufficiency Symptom Survey (CISS) for all participants. Pre-task measurements of reading performance and accuracy of accommodation and NPC were compared with post-task measurements, to test for any effects of prolonged reading. The prolonged reading task involved reading a storybook silently for at least 30 minutes. The task was controlled for print size, contrast, difficulty level and content of the reading material. Silent Reading Rate (SRR) was recorded every 2 minutes during prolonged reading. Symptom scores and visual fatigue scores were also obtained for all participants. A visual fatigue analogue scale (VAS) was used to assess visual fatigue during the task, once at the beginning, once at the middle and once at the end of the task. In addition to the subjective assessments of visual fatigue, tonic accommodation was monitored using a photorefractor (PlusoptiX CR03™) every 6 minutes during the task, as an objective assessment of visual fatigue. Reading measures were done at the habitual reading distance of students with low vision and at 25 cms for students with normal vision. The initial history showed that the students with low vision read for significantly shorter periods at home compared to the students with normal vision. The working distances of participants with low vision ranged from 3-25 cms and half of them were not using any optical devices for magnification. Nearly half of the participants with low vision were able to resolve 8-point print (1M) at 25 cms. Half of the participants in the low vision group had ocular deviations and suppression at near. Reading rates were significantly reduced in students with low vision compared to those of students with normal vision. In addition, there were a significantly larger number of participants in the low vision group who could not sustain the 30-minute task compared to the normal vision group. However, there were no significant changes in reading rates during or following prolonged reading in either the low vision or normal vision groups. Individual changes in reading rates were independent of their baseline reading rates, indicating that the changes in reading rates during prolonged reading cannot be predicted from a typical clinical assessment of reading using brief reading tasks. Contrary to previous reports the silent reading rates of the students with low vision were significantly lower than their oral reading rates, although oral and silent reading was assessed using different methods. Although the visual acuity, contrast sensitivity, near point of convergence and accuracy of accommodation were significantly poorer for the low vision group compared to those of the normal vision group, there were no significant changes in any of these visual functions following prolonged reading in either group. Interestingly, a few students with low vision (n =10) were found to be reading at a distance closer than their near point of accommodation. This suggests a decreased sensitivity to blur. Further evaluation revealed that the equivalent intrinsic refractive errors (an estimate of the spherical dioptirc defocus which would be expected to yield a patient’s visual acuity in normal subjects) were significantly larger for the low vision group compared to those of the normal vision group. As expected, accommodative responses were significantly reduced for the low vision group compared to the expected norms, which is consistent with their close reading distances, reduced visual acuity and contrast sensitivity. For those in the low vision group who had an accommodative error exceeding their equivalent intrinsic refractive errors, a significant decrease in MORR was found following prolonged reading. The silent reading rates however were not significantly affected by accommodative errors in the present study. Suppression also had a significant impact on the changes in reading rates during prolonged reading. The participants who did not have suppression at near showed significant decreases in silent reading rates during and following prolonged reading. This impact of binocular vision at near on prolonged reading was possibly due to the high demands on convergence. The significant predictors of MORR in the low vision group were age, NTVA, reading interest and reading comprehension, accounting for 61.7% of the variances in MORR. SRR was not significantly influenced by any factors, except for the duration of the reading task sustained; participants with higher reading rates were able to sustain a longer reading duration. In students with normal vision, age was the only predictor of MORR. Participants with low vision also reported significantly greater visual fatigue compared to the normal vision group. Measures of tonic accommodation however were little influenced by visual fatigue in the present study. Visual fatigue analogue scores were found to be significantly associated with reading rates in students with low vision and normal vision. However, the patterns of association between visual fatigue and reading rates were different for SRR and MORR. The participants with low vision with higher symptom scores had lower SRRs and participants with higher visual fatigue had lower MORRs. As hypothesized, visual functions such as accuracy of accommodation and convergence did have an impact on prolonged reading in students with low vision, for students whose accommodative errors were greater than their equivalent intrinsic refractive errors, and for those who did not suppress one eye. Those students with low vision who have accommodative errors higher than their equivalent intrinsic refractive errors might significantly benefit from reading glasses. Similarly, considering prisms or occlusion for those without suppression might reduce the convergence demands in these students while using their close reading distances. The impact of these prescriptions on reading rates, reading interest and visual fatigue is an area of promising future research. Most importantly, it is evident from the present study that a combination of factors such as accommodative errors, near point of convergence and suppression should be considered when prescribing reading devices for students with low vision. Considering these factors would also assist rehabilitation specialists in identifying those students who are likely to experience difficulty in prolonged reading, which is otherwise not reflected during typical clinical reading assessments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the influence of accommodation upon axial length (and a comprehensive range of ocular biometric parameters), in populations of young adult myopic and emmetropic subjects. Methods: Forty young adult subjects had ocular biometry measured utilizing a non-contact optical biometer (Lenstar LS 900) based upon the principle of optical low coherence reflectometry, under three different accommodation demands (0 D, 3 D and 6 D). Subjects were classified as emmetropes (n=19) or myopes (n=21) based upon their spherical equivalent refraction (mean emmetropic refraction -0.05 ± 0.27DS and mean myopic refraction -1.82 ± 0.84 DS). Results: Axial length changed significantly with accommodation, with a mean increase of 11.9 ± 12.3 µm and 24.1 ± 22.7 µm for the 3 D and 6 D accommodation stimuli respectively. A significant axial elongation associated with accommodation was still evident even following correction of the axial length data for potential error due to lens thickness change. The mean ‘corrected’ increase in axial length was 5.2 ± 11.2 µm, and 7.4 ± 18.9 µm for the 3 D and 6 D stimuli respectively. There was no significant difference between the myopic and emmetropic populations in terms of the magnitude of change in axial length with accommodation, regardless of whether the data were corrected or not. A number of other ocular biometric parameters, such as anterior chamber depth, lens thickness and vitreous chamber depth also exhibited significant change with accommodation. The myopic and emmetropic populations also exhibited no significant difference in the magnitude of change in these parameters with accommodation. Conclusions: The eye undergoes a significant axial elongation associated with a brief period of accommodation, and the magnitude of this change in eye length increases for larger accommodation demands, however there is no significant difference in the magnitude of eye elongation in myopic and emmetropic subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the short term influence of imposed monocular defocus upon human optical axial length (the distance from anterior cornea to retinal pigment epithelium) and ocular biometrics. Methods: Twenty-eight young adult subjects (14 myopes and 14 emmetropes) had eye biometrics measured before and then 30 and 60 minutes after exposure to monocular (right eye) defocus. Four different monocular defocus conditions were tested, each on a separate day: control (no defocus), myopic (+3 D defocus), hyperopic (-3 D defocus) and diffuse (0.2 density Bangerter filter) defocus. The fellow eye was optimally corrected (no defocus). Results: Imposed defocus caused small but significant changes in optical axial length (p<0.0001). A significant increase in optical axial length (mean change +8 ± 14 μm, p=0.03) occurred following hyperopic defocus, and a significant reduction in optical axial length (mean change -13 ± 14 μm, p=0.0001) was found following myopic defocus. A small increase in optical axial length was observed following diffuse defocus (mean change +6 ± 13 μm, p=0.053). Choroidal thickness also exhibited some significant changes with certain defocus conditions. No significant difference was found between myopes and emmetropes in the changes in optical axial length or choroidal thickness with defocus. Conclusions: Significant changes in optical axial length occur in human subjects following 60 minutes of monocular defocus. The bi-directional optical axial length changes observed in response to defocus implies the human visual system is capable of detecting the presence and sign of defocus and altering optical axial length to move the retina towards the image plane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to investigate the influence of water loading upon intraocular pressure (IOP), ocular pulse amplitude (OPA) and axial length. Twenty one young adult subjects who were classified based on their spherical equivalent refraction as either myopes (n=11), or emmetropes (n=10) participated. Measures of IOP, OPA and ocular biometrics were collected before, and then 10, 15, 25 and 30 minutes following the ingestion of 1000 ml of water. Significant increases in both IOP and OPA were found to occur following water loading (p<0.0001), with peaks in both parameters occurring at 10 minutes after water loading (mean ± SEM increase of 2.24 ± 0.31 mmHg in IOP and 0.46 ± 0.06 mmHg in OPA). Axial length was found to reduce significantly following water loading (p=0.0005), with the largest reduction in axial length evident 10 minutes after water drinking (mean decrease 12 ± 3 µm). A significant time by refractive error group interaction (p=0.048) was found in axial length, indicative of a different pattern of change in eye length following water loading between the myopic and emmetropic populations. The largest difference in axial length change was evident at 10 minutes after water loading with a 17 ± 5 µm reduction in axial length evident in the myopes and only a 6 ± 2 µm reduction in the emmetropes. These findings illustrate significant changes in ocular parameters in young adult subjects following water loading.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: One strategy to minimize bacteria-associated adverse responses such as microbial keratitis, contact lens–induced acute red eye (CLARE), and contact lens induced peripheral ulcers (CLPUs) that occur with contact lens wear is the development of an antimicrobial or antiadhesive contact lens. Cationic peptides represent a novel approach for the development of antimicrobial lenses.---------- Methods: A novel cationic peptide, melimine, was covalently incorporated into silicone hydrogel lenses. Confirmation tests to determine the presence of peptide and anti-microbial activity were performed. Cationic lenses were then tested for their ability to prevent CLPU in the Staphylococcus aureus rabbit model and CLARE in the Pseudomonas aeruginosa guinea pig model. ---------- Results: In the rabbit model of CLPU, melimine-coated lenses resulted in significant reductions in ocular symptom scores and in the extent of corneal infiltration (P < 0.05). Evaluation of the performance of melimine lenses in the CLARE model showed significant improvement in all ocular response parameters measured, including the percentage of eyes with corneal infiltrates, compared with those observed in the eyes fitted with the control lens (P ≤ 0.05). ---------- Conclusions: Cationic coating of contact lenses with the peptide melimine may represent a novel method of prevention of bacterial growth on contact lenses and consequently result in reduction of the incidence and severity of adverse responses due to Gram-positive and -negative bacteria during lens wear.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. The objective of this study was to explore the discriminative capacity of non-contact corneal esthesiometry (NCCE) when compared with the neuropathy disability score (NDS) score—a validated, standard method of diagnosing clinically significant diabetic neuropathy. Methods. Eighty-one participants with type 2 diabetes, no history of ocular disease, trauma, or surgery and no history of systemic disease that may affect the cornea were enrolled. Participants were ineligible if there was history of neuropathy due to non-diabetic cause or current diabetic foot ulcer or infection. Corneal sensitivity threshold was measured on the eye of dominant hand side at a distance of 10 mm from the center of the cornea using a stimulus duration of 0.9 s. The NDS was measured producing a score ranging from 0 to 10. To determine the optimal cutoff point of corneal sensitivity that identified the presence of neuropathy (diagnosed by NDS), the Youden index and “closest-to-(0,1)” criteria were used. Results. The receiver-operator characteristic curve for NCCE for the presence of neuropathy (NDS ≥3) had an area under the curve of 0.73 (p = 0.001) and, for the presence of moderate neuropathy (NDS ≥6), area of 0.71 (p = 0.003). By using the Youden index, for an NDS ≥3, the sensitivity of NCCE was 70% and specificity was 75%, and a corneal sensitivity threshold of 0.66 mbar or higher indicated the presence of neuropathy. When NDS ≥6 (indicating risk of foot ulceration) was applied, the sensitivity was 52% with a specificity of 85%. Conclusions. NCCE is a sensitive test for the diagnosis of minimal and more advanced diabetic neuropathy and may serve as a useful surrogate marker for diabetic and perhaps other neuropathies.