397 resultados para Rudy, Gerard
Resumo:
In this paper, the placement of sectionalizers, as well as, a cross-connection is optimally determined so that the objective function is minimized. The objective function employed in this paper consists of two main parts, the switch cost and the reliability cost. The switch cost is composed of the cost of sectionalizers and cross-connection and the reliability cost is assumed to be proportional to a reliability index, SAIDI. To optimize the allocation of sectionalizers and cross-connection problem realistically, the cost related to each element is considered as discrete. In consequence of binary variables for the availability of sectionalizers, the problem is extremely discrete. Therefore, the probability of local minimum risk is high and a heuristic-based optimization method is needed. A Discrete Particle Swarm Optimization (DPSO) is employed in this paper to deal with this discrete problem. Finally, a testing distribution system is used to validate the proposed method.
Resumo:
Isolation of a faulted segment, from either side of a fault, in a radial feeder that has several converter interfaced DGs is a challenging task when current sensing protective devices are employed. The protective device, even if it senses a downstream fault, may not operate if fault current level is low due to the current limiting operation of converters. In this paper, a new inverse type relay is introduced based on line admittance measurement to protect a distribution network, which has several converter interfaced DGs. The basic operation of this relay, its grading and reach settings are explained. Moreover a method is proposed to compensate the fault resistance such that the relay operation under this condition is reliable. Then designed relay performances are evaluated in a radial distribution network. The results are validated through PSCAD/EMTDC simulation and MATLAB calculations.
Resumo:
Decentralized and regional load-frequency control of power systems operating in normal and near-normal conditions has been well studied; and several analysis/synthesis approaches have been developed during the last few decades. However in contingency and off-normal conditions, the existing emergency control plans, such as under-frequency load shedding, are usually applied in a centralized structure using a different analysis model. This paper discusses the feasibility of using frequency-based emergency control schemes based on tie-line measurements and local information available within a control area. The conventional load-frequency control model is generalized by considering the dynamics of emergency control/protection schemes and an analytic approach to analyze the regional frequency response under normal and emergency conditions is presented.
Resumo:
Introduction: The demand for emergency health services (EHS), both in the prehospital (ambulance) and hospital (emergency departments) settings, is growing rapidly in Australia. Broader health system changes have reduced available health infrastructure, particularly hospital beds, resulting in reduced access to and congestion of the EHS as demonstrated by longer waiting times and ambulance “ramping”. Ambulance ramping occurring when patients have a prolonged wait on the emergency vehicle due to the unavailability of hospital beds. This presentation will outline the trends in EHS demand in Queensland compared with the rest of Australia and factors that appear to be contributing to the growth in demand. Methods: Secondary analysis was conducted using data from publicly available sources. Data from the Queensland Ambulance Service and Queensland Health Emergency Department Information System (EDIS) also were analyzed. Results: The demand for ambulance services and emergency departments has been increasing at 8% and 4% per year over the last decade, respectively; while accessible hospital beds have reduced by almost 10% contributing to the emergency department congestion and possibly contributing to the prehospital demand. While the increase in the proportion of the elderly population seems to explain a great deal of the demand for EHS, other factors also influence this growth including patient characteristics, institutional and societal factors, economic, EHS arrangements, and clinical factors. Conclusions: Overcrowding of facilities that provide EHS are causing considerable community concern. This overcrowding is caused by the growing demand and reduced access. The causes of this growing demand are complex, and require further detailed analysis in order to quantify and qualify these causes in order to provide a resilient foundation of evidence for future policy direction.
Resumo:
The requirement for improved efficiency whilst maintaining system security necessitates the development of improved system analysis approaches and the development of advanced emergency control technologies. Load shedding is a type of emergency control that is designed to ensure system stability by curtailing system load to match generation supply. This paper presents a new adaptive load shedding scheme that provides emergency protection against excess frequency decline, whilst minimizing the risk of line overloading. The proposed load shedding scheme uses the local frequency rate information to adapt the load shedding behaviour to suit the size and location of the experienced disturbance. The proposed scheme is tested in simulation on a 3-region, 10-generator sample system and shows good performance.
Resumo:
The distribution network reliability can be increased if distributed generators (DGs) are allowed to operate in both grid-connected and islanded operations when the network has a high DG penetration level. However, the current utility regulations do not allow for the islanded operation. The arc faults are the one of the major issues preventing the islanded operation, since the arc will not extinguish if the DGs are not disconnected. In this paper, the effect of a converter interfaced DG on an arc fault is investigated by considering different control strategies for the converter. The foldback current control characteristic is proposed to a converter interfaced DG to achieve quick arc extinction and self-restoration without disconnecting the DG in the event of an arc fault. The results are validated through PSCAD/EMTDC simulations.
Resumo:
Both clinical practice and clinical research settings can require successive administrations of a memory test, particularly when following the trajectory of suspected memory decline in older adults. However, relatively few verbal episodic memory tests have alternative forms. We set out to create a broad based memory test to allow for the use of an essentially unlimited number of alternative forms. Four tasks for inclusion in such a test were developed. These tasks varied the requirement for recall as opposed to recognition, the need to form an association between unrelated words, and the need to discriminate the most recent list from earlier lists, all of which proved useful. A total of 115 participants completed the battery of tests and were used to show that the test could differentiate between older and younger adults; a sub-sample of 73 participants completed alternative forms of the tests to determine test-retest reliability and the amount of learning to learn.
Resumo:
To allocate and size capacitors in a distribution system, an optimization algorithm, called Discrete Particle Swarm Optimization (DPSO), is employed in this paper. The objective is to minimize the transmission line loss cost plus capacitors cost. During the optimization procedure, the bus voltage, the feeder current and the reactive power flowing back to the source side should be maintained within standard levels. To validate the proposed method, the semi-urban distribution system that is connected to bus 2 of the Roy Billinton Test System (RBTS) is used. This 37-bus distribution system has 22 loads being located in the secondary side of a distribution substation (33/11 kV). Reducing the transmission line loss in a standard system, in which the transmission line loss consists of only about 6.6 percent of total power, the capabilities of the proposed technique are seen to be validated.
Resumo:
Adjuvant use of nutritional and herbal medicines has potential to increase the efficacy of synthetic pharmaceuticals, and perhaps also decrease their side-effects by allowing lower doses to be prescribed. We evaluated current evidence for adjuvant use of nutritional and herbal medicines with antidepressants, mood stabilizers and benzodiazepines; and explored novel future areas of research. The paper also critiques current evidence for co-administration of St. John’s wort with synthetic antidepressants. We performed a systematic search of MEDLINE, CINAHL, PsycINFO, The Cochrane database, China National Knowledge Infrastructure and the Chinese Science Citation Database. Search results were supplemented by a review of reference lists and a forward search using the Web of Science. Where possible we calculated effect sizes. Encouraging evidence exists for the use of omega-3 fatty acids, SAMe, folic acid and l-tryptophan adjuvantly with antidepressants to enhance response and improve efficacy. Various nutrients also have emerging evidence as effective adjuncts with antipsychotics and mood stabilizers. While some evidence supports nutritional adjuvancy with various psychopharmacotherapies, adjuvant use of herbal therapies has not been sufficiently studied to warrant standard clinical application. This remains a promising area of research via robust, safety-conscious studies.
Resumo:
Objective: The emergency medical system (EMS) can be defined as a comprehensive, coordinated and integrated system of care for patients suffering acute illness and injury. The aim of the present paper is to describe the evolution of the Queensland Emergency Medical System (QEMS) and to recommend a strategic national approach to EMS development. Methods: Following the formation of the Queensland Ambulance Service in 1991, a state EMS committee was formed. This committee led the development and approval of the cross portfolio QEMS policy framework that has resulted in dynamic policy development, system monitoring and evaluation. This framework is led by the Queensland Emergency Medical Services Advisory Committee. Results: There has been considerable progress in the development of all aspects of the EMS in Queensland. These developments have derived from the improved coordination and leadership that QEMS provides and has resulted in widespread satisfaction by both patients and stakeholders. Conclusions: The strategic approach outlined in the present paper offers a model for EMS arrangements throughout Australia. We propose that the Council of Australian Governments should require each state and Territory to maintain an EMS committee. These state EMS committees should have a broad portfolio of responsibilities. They should provide leadership and direction to the development of the EMS and ensure coordination and quality of outcomes. A national EMS committee with broad representation and broad scope should be established to coordinate the national development of Australia's EMS.
Resumo:
Background: There are indications that pre-hospital emergency care and management of patients can help reduce the demand for hospital emergency departments (EDs). Ambulance services play a significant role at this stage of care. In 2003, the Queensland Government introduced a Community Ambulance Cover (CAC) levy in return for a free ambulance service at the point of access to all Queenslanders. This may have led to the impression in consumers of an entitlement to free ambulance services under any circumstances regardless of the urgency of the matter which may have in turn contributed to the crowding of EDs in Queensland. Objectives: This paper aims to answer the following questions: - How many patients arrive at hospital EDs by ambulance in Queensland, compared to other modes of arrival? - How has this changed over time, particularly after the CAC introduction in 2003? What percentage of ambulance arrivals are urgent ED patients? - Has the perceived free ambulance services created extra demand for EDs in Queensland, compared with other Australian jurisdictions that charge patients for ambulance services? Methods: We will secondary analyse the data from sources such as Queensland Ambulance Services, Department of Health and Australian Bureau of Statistics to answer the research questions. Findings and Conclusions Queensland has the highest utilization rate of ambulance services (about 18% in 2007-08) and the highest annual growth rate in demand for these services (7.7% on average since 2000-01), well above the population growth. On the other hand, the proportion of ED patients arriving by ambulance in Queensland has increased by about 4% annually. However, when compared with other states and territories with charge at the point of access, it seems that the growth in demand for EDs cannot be explained solely or mainly by CAC or ambulance utilisation in Queensland.
Resumo:
Triage is a process that is critical to the effective management of modern emergency departments. Triage systems aim, not only to ensure clinical justice for the patient, but also to provide an effective tool for departmental organisation, monitoring and evaluation. Over the last 20 years, triage systems have been standardised in a number of countries and efforts made to ensure consistency of application. However, the ongoing crowding of emergency departments resulting from access block and increased demand has led to calls for a review of systems of triage. In addition, international variance in triage systems limits the capacity for benchmarking. The aim of this paper is to provide a critical review of the literature pertaining to emergency department triage in order to inform the direction for future research. While education, guidelines and algorithms have been shown to reduce triage variation, there remains significant inconsistency in triage assessment arising from the diversity of factors determining the urgency of any individual patient. It is timely to accept this diversity, what is agreed, and what may be agreeable. It is time to develop and test an International Triage Scale (ITS) which is supported by an international collaborative approach towards a triage research agenda. This agenda would seek to further develop application and moderating tools and to utilise the scales for international benchmarking and research programmes.
Resumo:
Background For more than a decade emergency medicine organizations have produced guidelines, training and leadership for disaster management. However to date, there have been limited guidelines for emergency physicians needing to provide a rapid response to a surge in demand. The aim of this study is to identify strategies which may guide surge management in the Emergency Department. Method A working group of individuals experienced in disaster medicine from the Australasian College for Emergency Medicine Disaster Medicine Subcommittee (the Australasian Surge Strategy Working Group) was established to undertake this work. The Working Group used a modified Delphi technique to examine response actions in surge situations. The Working Group identified underlying assumptions from epidemiological and empirical understanding and then identified remedial strategies from literature and from personal experience and collated these within domains of space, staff, supplies, and system operation. Findings These recommendations detail 22 potential actions available to an emergency physician working in the context of surge. The Working Group also provides detailed guidance on surge recognition, triage, patient flow through the emergency department and clinical goals and practices. Discussion These strategies provide guidance to emergency physicians confronting the challenges of a surge in demand. The paper also identifies areas that merit future research including the measurement of surge capacity, constraints to strategy implementation, validation of surge strategies and measurement of strategy impacts on throughput, cost, and quality of care.
Resumo:
This paper describes protection and control of a microgrid with converter interfaced micro sources. The proposed protection and control scheme consider both grid connected and autonomous operation of the microgrid. A protection scheme, capable of detecting faults effectively in both grid connected and islanded operations is proposed. The main challenge of the protection, due to current limiting state of the converters is overcome by using admittance relays. The relays operate according to the inverse time characteristic based on measured admittance of the line. The proposed scheme isolates the fault from both sides, while downstream side of the microgrid operates in islanding condition. Moreover faults can be detected in autonomous operation. In grid connected mode distributed generators (DG) supply the rated power while in absence of the grid, DGs share the entire power requirement proportional to rating based on output voltage angle droop control. The protection scheme ensures minimum load shedding with isolating the faulted network and DG control provides a smooth islanding and resynchronization operation. The efficacy of coordinated control and protection scheme has been validated through simulation for various operating conditions.
Resumo:
This paper presents a reliability-based reconfiguration methodology for power distribution systems. Probabilistic reliability models of the system components are considered and Monte Carlo method is used while evaluating the reliability of the distribution system. The reconfiguration is aimed at maximizing the reliability of the power supplied to the customers. A binary particle swarm optimization (BPSO) algorithm is used as a tool to determine the optimal configuration of the sectionalizing and tie switches in the system. The proposed methodology is applied on a modified IEEE 13-bus distribution system.