230 resultados para RCE-PD (resonant-cavity-enhanced photodiode)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study used ERPs to compare processing of fear-relevant (FR) animals (snakes and spiders) and non-fear-relevant (NFR) animals similar in appearance (worms and beetles). EEG was recorded from 18 undergraduate participants (10 females) as they completed two animal-viewing tasks that required simple categorization decisions. Participants were divided on a post hoc basis into low snake/spider fear and high snake/spider fear groups. Overall, FR animals were rated higher on fear and elicited a larger LPC. However, individual differences qualified these effects. Participants in the low fear group showed clear differentiation between FR and NFR animals on subjective ratings of fear and LPC modulation. In contrast, participants in the high fear group did not show such differentiation between FR and NFR animals. These findings suggest that the salience of feared-FR animals may generalize on both a behavioural and electro-cortical level to other animals of similar appearance but of a non-harmful nature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface coating with an organic self-assembled monolayer (SAM) can enhance surface reactions or the absorption of specific gases and hence improve the response of a metal oxide (MOx) sensor toward particular target gases in the environment. In this study the effect of an adsorbed organic layer on the dynamic response of zinc oxide nanowire gas sensors was investigated. The effect of ZnO surface functionalisation by two different organic molecules, tris(hydroxymethyl)aminomethane (THMA) and dodecanethiol (DT), was studied. The response towards ammonia, nitrous oxide and nitrogen dioxide was investigated for three sensor configurations, namely pure ZnO nanowires, organic-coated ZnO nanowires and ZnO nanowires covered with a sparse layer of organic-coated ZnO nanoparticles. Exposure of the nanowire sensors to the oxidising gas NO2 produced a significant and reproducible response. ZnO and THMA-coated ZnO nanowire sensors both readily detected NO2 down to a concentration in the very low ppm range. Notably, the THMA-coated nanowires consistently displayed a small, enhanced response to NO2 compared to uncoated ZnO nanowire sensors. At the lower concentration levels tested, ZnO nanowire sensors that were coated with THMA-capped ZnO nanoparticles were found to exhibit the greatest enhanced response. ΔR/R was two times greater than that for the as-prepared ZnO nanowire sensors. It is proposed that the ΔR/R enhancement in this case originates from the changes induced in the depletion-layer width of the ZnO nanoparticles that bridge ZnO nanowires resulting from THMA ligand binding to the surface of the particle coating. The heightened response and selectivity to the NO2 target are positive results arising from the coating of these ZnO nanowire sensors with organic-SAM-functionalised ZnO nanoparticles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel concept of producing high dc voltage for pulsed-power applications is proposed in this paper. The topology consists of an LC resonant circuit supplied through a tuned alternating waveform that is produced by an inverter. The control scheme is based on the detection of variations in the resonant frequency and adjustment of the switching signal patterns for the inverter to produce a square waveform with exactly the same frequencies. Therefore the capacitor voltage oscillates divergently with an increasing amplitude. A simple one-stage capacitor-diode voltage multiplier (CDVM) connected to the resonant capacitor then rectifies the alternating voltage and gives a dc level equal to twice the input voltage amplitude. The produced high voltage appears then in the form of high-voltage pulses across the load. A basic model is simulated by Simulink platform of MATLAB and the results are included in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study the interplay effects for Enhanced Dynamic Wedge (EDW) treatments are experimentally investigated. Single and multiple field EDW plans for different wedge angles were delivered to a phantom and detector on a moving platform, with various periods, amplitudes for parallel and perpendicular motions. A four field 4D CT planned lung EDW treatment was delivered to a dummy tumor over four fractions. For the single field parallel case the amplitude and the period of motion both affect the interplay resulting in the appearance of a step function and penumbral cut off with the discrepancy worst where collimator-tumor speed is similar. For perpendicular motion the amplitude of tumor motion is the only dominant factor. For large wedge angle the dose discrepancy is more pronounced compared to the small wedge angle for the same field size and amplitude-period values. For a small field size i.e. 5 × 5 cm2 the loss of wedged distribution was observed for both 60º and 15º wedge angles for of parallel and perpendicular motions. Film results from 4D CT planned delivery displayed a mix of over and under dosages over 4 fractions, with the gamma pass rate of 40% for the averaged film image at 3%/1 mm DTA (Distance to Agreement). Amplitude and period of the tumor motion both affect the interplay for single and multi-field EDW treatments and for a limited (4 or 5) fraction delivery there is a possibility of non-averaging of the EDW interplay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enhanced mill extraction model has been developed to calculate mill performance parameters and to predict the extraction performance of a milling unit. The model takes into account the fibre suspended in juice streams and calculates filling ratio, reabsorption factor, imbibition coefficient, and separation efficiency using more complete definitions than those used in previous extraction models. A mass balance model is used to determine the fibre, brix and moisture mass flows between milling units so that a complete milling train, including the return stream from the juice screen, is modelled. Model solutions are presented to determine the effect of different levels of fibre in juice and efficiency of fibre separation in the juice screen on brix extraction. The model provides more accurate results than earlier models leading to better understanding and improvement of the milling process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerical simulations for mixed convection of micropolar fluid in an open ended arc-shape cavity have been carried out in this study. Computation is performed using the Alternate Direct Implicit (ADI) method together with the Successive Over Relaxation (SOR) technique for the solution of governing partial differential equations. The flow phenomenon is examined for a range of values of Rayleigh number, 102 ≤ Ra ≤ 106, Prandtl number, 7 ≤ Pr ≤ 50, and Reynolds number, 10 ≤ Re ≤ 100. The study is mainly focused on how the micropolar fluid parameters affect the fluid properties in the flow domain. It was found that despite the reduction of flow in the core region, the heat transfer rate increases, whereas the skin friction and microrotation decrease with the increase in the vortex viscosity parameter, Δ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Queensland University of Technology (QUT) was one of the first universities in Australia to establish an institutional repository. Launched in November 2003, the repository (QUT ePrints) uses the EPrints open source repository software (from Southampton) and has enjoyed the benefit of an institutional deposit mandate since January 2004. Currently (April 2012), the repository holds over 36,000 records, including 17,909 open access publications with another 2,434 publications embargoed but with mediated access enabled via the ‘Request a copy’ button which is a feature of the EPrints software. At QUT, the repository is managed by the library.QUT ePrints (http://eprints.qut.edu.au) The repository is embedded into a number of other systems at QUT including the staff profile system and the University’s research information system. It has also been integrated into a number of critical processes related to Government reporting and research assessment. Internally, senior research administrators often look to the repository for information to assist with decision-making and planning. While some statistics could be drawn from the advanced search feature and the existing download statistics feature, they were rarely at the level of granularity or aggregation required. Getting the information from the ‘back end’ of the repository was very time-consuming for the Library staff. In 2011, the Library funded a project to enhance the range of statistics which would be available from the public interface of QUT ePrints. The repository team conducted a series of focus groups and individual interviews to identify and prioritise functionality requirements for a new statistics ‘dashboard’. The participants included a mix research administrators, early career researchers and senior researchers. The repository team identified a number of business criteria (eg extensible, support available, skills required etc) and then gave each a weighting. After considering all the known options available, five software packages (IRStats, ePrintsStats, AWStats, BIRT and Google Urchin/Analytics) were thoroughly evaluated against a list of 69 criteria to determine which would be most suitable. The evaluation revealed that IRStats was the best fit for our requirements. It was deemed capable of meeting 21 out of the 31 high priority criteria. Consequently, IRStats was implemented as the basis for QUT ePrints’ new statistics dashboards which were launched in Open Access Week, October 2011. Statistics dashboards are now available at four levels; whole-of-repository level, organisational unit level, individual author level and individual item level. The data available includes, cumulative total deposits, time series deposits, deposits by item type, % fulltexts, % open access, cumulative downloads, time series downloads, downloads by item type, author ranking, paper ranking (by downloads), downloader geographic location, domains, internal v external downloads, citation data (from Scopus and Web of Science), most popular search terms, non-search referring websites. The data is displayed in charts, maps and table format. The new statistics dashboards are a great success. Feedback received from staff and students has been very positive. Individual researchers have said that they have found the information to be very useful when compiling a track record. It is now very easy for senior administrators (including the Deputy Vice Chancellor-Research) to compare the full-text deposit rates (i.e. mandate compliance rates) across organisational units. This has led to increased ‘encouragement’ from Heads of School and Deans in relation to the provision of full-text versions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold-formed steel stud walls are an important component of Light Steel Framing (LSF) building systems used in commercial, industrial and residential buildings. In the conventional LSF stud wall systems, thin-walled steel studs are protected from fire by placing one or two layers of plasterboard on both sides with or without cavity insulation. However, there is very limited data about the structural and thermal performance of these wall systems while past research showed contradicting results about the benefits of cavity insulation. This research proposed a new LSF stud wall system in which a composite panel made of two plasterboards with insulation between them was used to improve the fire rating of walls. Full scale fire tests were conducted using both conventional steel stud walls with and without the use of cavity insulation and the new composite panel system. Eleven full scale load bearing wall specimens were tested to study the thermal and structural performances of the load bearing wall assemblies under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls while also providing good explanations and supporting test data to overcome the incorrect industry assumptions about cavity insulation. Tests demonstrated that the use of external insulation in a composite panel form enhanced the thermal and structural performances of stud walls and increased their fire resistance rating significantly. This paper presents the details of the full scale fire tests of load-bearing wall assemblies lined with plasterboards and different types of insulation under varying load ratios. Test results including the temperature and deflection profiles of walls measured during the fire tests will be presented along with their failure modes and failure times.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electromagnetic enhancement that occurs in surface enhanced Raman scattering (SERS) substrates containing gold nanoparticles (NPs) is believed to arise through the generation of localised surface plasmons. We present results that show no SERS signals are obtained when 25 nm diameter gold NPs layered quartz substrates exposed to 2-aminopyridine are illuminated with plasmon resonant 532 nm radiation, but SERS signals are observed when the same samples are illuminated with non-resonant 785 nm radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Queensland graduated driver licensing (GDL) context (post-July 2007) - The experiences of young Learner drivers - Comparison of pre- (‘Original-GDL’) and post-July 2007 (‘Enhanced-GDL’) experiences - Post-July 2007 experiences - GDL-related issues - Other factors in young novice driver safety - Person-related factors - Social factors

Relevância:

20.00% 20.00%

Publicador:

Resumo:

- Young novice drivers - The Queensland graduated driver licensing (GDL) context - Pre-July 2007 (‘Original-GDL’) - Post-July 2007 (‘Enhanced-GDL’) - Experiences of Learners in Queensland’s enhanced-GDL program - Pre-/post-July 2007 comparison - Post-July 2007 only - Implications - Strengths and limitations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inadequate vitamin D levels have been linked to bone disease but more recently have been associated with wider health implications. Limited studies suggest a high prevalence of Vitamin D deficiency in dialysis patients, although evidence is lacking on whether this is due to dietary restrictions, limited mobility and time outdoors or a combination of these. The aim of this study was to assess the contributions of diet, supplements and sunlight exposure to serum Vitamin D (25(OH)D) levels in dialysis patients. Cross-sectional data were obtained from 30 PD (Mean±SD age 56.9±16.2 y; n=13 male) and 22 HD (Mean±SD age 65.4±14.0 y; n=18 male) patients between 2009 and 2010. Serum 25(OH)D was measured and oral vitamin D intake estimated through a food-frequency-questionnaire and quantifying inactive supplementation. Sunlight exposure was assessed using a validated questionnaire. Prevalence of inadequate/insufficient vitamin D differed between dialysis modality (31% and 43% insufficient (<50nmol/L); 4% and 34% deficient (<25nmol/L) in HD and PD patients respectively (p=0.002)). In HD patients, there was a significant correlation between diet plus supplemental vitamin D intake and 25(OH)D (ρ=0.84, p<0.001). Results suggest a higher frequency of 25(OH)D inadequacy/deficiency in PD compared to HD patients. No other relationships between intake, sun exposure and 25(OH)D were seen. This could reflect limitations of the study design or the importance of other factors such as age, ethnicity and sun protection as interactions in the analysis. Understanding these factors is important given Vitamin D’s emerging status as a biomarker of systemic ill health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A characteristic of Parkinson's disease (PD) is the development of tremor within the 4–6 Hz range. One method used to better understand pathological tremor is to compare the responses to tremor-type actions generated intentionally in healthy adults. This study was designed to investigate the similarities and differences between voluntarily generated 4–6 Hz tremor and PD tremor in regards to their amplitude, frequency and coupling characteristics. Tremor responses for 8 PD individuals (on- and off-medication) and 12 healthy adults were assessed under postural and resting conditions. Results showed that the voluntary and PD tremor were essentially identical with regards to the amplitude and peak frequency. However, differences between the groups were found for the variability (SD of peak frequency, proportional power) and regularity (Approximate Entropy, ApEn) of the tremor signal. Additionally, coherence analysis revealed strong inter-limb coupling during voluntary conditions while no bilateral coupling was seen for the PD persons. Overall, healthy participants were able to produce a 5 Hz tremulous motion indistinguishable to that of PD patients in terms of peak frequency and amplitude. However, differences in the structure of variability and level of inter-limb coupling were found for the tremor responses of the PD and healthy adults. These differences were preserved irrespective of the medication state of the PD persons. The results illustrate the importance of assessing the pattern of signal structure/variability to discriminate between different tremor forms, especially where no differences emerge in standard measures of mean amplitude as traditionally defined.