137 resultados para Periodicals (Russian)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

High density SNP arrays can be used to identify DNA copy number changes in tumors such as homozygous deletions of tumor suppressor genes and focal amplifications of oncogenes. Illumina Human CNV370 Bead chip arrays were used to assess the genome for unbalanced chromosomal events occurring in 39 cell lines derived from stage III metastatic melanomas. A number of genes previously recognized to have an important role in the development and progression of melanoma were identified including homozygous deletions of CDKN2A (13 of 39 samples), CDKN2B (10 of 39), PTEN (3 of 39), PTPRD (3 of 39), TP53 (1 of 39), and amplifications of CCND1 (2 of 39), MITF (2 of 39), MDM2 (1 of 39), and NRAS (1 of 39). In addition, a number of focal homozygous deletions potentially targeting novel melanoma tumor suppressor genes were identified. Because of their likely functional significance for melanoma progression, FAS, CH25H, BMPR1A, ACTA2, and TFG were investigated in a larger cohort of melanomas through sequencing. Nonsynonymous mutations were identified in BMPR1A (1 of 43), ACTA2 (3 of 43), and TFG (5 of 103). A number of potentially important mutation events occurred in TFG including the identification of a mini mutation ‘‘hotspot’’ at amino acid residue 380 (P380S and P380L) and the presence of multiple mutations in two melanomas. Mutations in TFG may have important clinical relevance for current therapeutic strategies to treat metastatic melanoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow-balancing Starling response is diminished in both ventricles. The reliability of sensor and sensor-less based control systems which aim to control VAD flow based on preload have limitations and thus an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a compliant inflow cannula could potentially be used as a passive control system to prevent suction events in rotary left, right and biventricular support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Successful anatomic fitting of a total artificial heart (TAH) is vital to achieve optimal pump hemodynamics after device implantation. Although many anatomic fitting studies have been completed in humans prior to clinical trials, few reports exist that detail the experience in animals for in vivo device evaluation. Optimal hemodynamics are crucial throughout the in vivo phase to direct design iterations and ultimately validate device performance prior to pivotal human trials. In vivo evaluation in a sheep model allows a realistically sized representation of a smaller patient, for which smaller third-generation TAHs have the potential to treat. Our study aimed to assess the anatomic fit of a single device rotary TAH in sheep prior to animal trials and to use the data to develop a threedimensional, computer-aided design (CAD)-operated anatomic fitting tool for future TAH development. Following excision of the native ventricles above the atrio-ventricular groove, a prototype TAH was inserted within the chest cavity of six sheep (28–40 kg).Adjustable rods representing inlet and outlet conduits were oriented toward the center of each atrial chamber and the great vessels, with conduit lengths and angles recorded for future analysis. A threedimensional, CAD-operated anatomic fitting tool was then developed, based on the results of this study, and used to determine the inflow and outflow conduit orientation of the TAH. The mean diameters of the sheep left atrium, right atrium, aorta, and pulmonary artery were 39, 33, 12, and 11 mm, respectively. The center-to-center distance and outer-edge-to-outer-edge distance between the atria, found to be 39 ± 9 mm and 72 ± 17 mm in this study, were identified as the most critical geometries for successful TAH connection. This geometric constraint restricts the maximum separation allowable between left and right inlet ports of a TAH to ensure successful alignment within the available atrial circumference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Right heart dysfunction is one of the most serious complications following implantation of a left ventricular assist device (LVAD), often leading to the requirement for short or long term right ventricular support (RVAD). The inflow cannulation site induces major haemodynamic changes and so there is a need to optimize the site used depending on the patient's condition. Therefore, this study evaluated and compared the haemodynamic influence of right atrial (RAC) and right ventricular (RVC) inflow cannulation sites. An in-vitro, variable heart failure, mock circulation loop was used to compare RAC and RVC in mild and severe biventricular heart failure (BHF) conditions. In the severe BHF condition, higher ventricular ejection fraction (RAC: 13.6%, RVC: 32.7%) and thus improved heart chamber and RVAD washout was observed with RVC, which suggested this strategy might be preferable for long term support (ie. bridge to transplant or destination therapy) to reduce the risk of thrombus formation. In the mild BHF condition, higher pulmonary valve flow (RAC: 3.33 L/min, RVC: 1.97 L/min) and lower right ventricular stroke work (RAC: 0.10 W, RVC: 0.13 W) and volumes were recorded with RAC. These results indicate an improved potential for myocardial recovery, thus RAC should be chosen in this condition. This in-vitro study suggests that RVAD inflow cannulation site should be chosen on a patient-specific basis with a view to the support strategy to promote myocardial recovery or reduce the risk of long-term complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Young motherhood is commonly associated with vulnerabilities, stereotyping of young women’s behaviour and poor outcomes for them and their children. The objective was to understand how maternity care is experienced for this group in the transition to parenthood. Methods: Data from a large-scale 2010 survey of women’s experience of maternity care were analysed using qualitative methods with open text responses. Results: 7,193 women responded to the survey: 237 were aged 20 years or less. Most (83%) of these young women provided open text responses. The main themes were: ‘being a consumer’, ‘the quality of care’, ‘needing support’ and ‘pride in parenthood’ while subthemes included ‘being young’ and ‘how staff made me feel’, ‘testimonials for staff’, ‘not being left’ and ‘it’s all worthwhile’. Conclusion: Many young women responding described a positive experience. For many first time mothers this marked a positive change in their identity. Nevertheless staff perceptions and attitudes affected how they saw themselves and what they took away from their experience of maternity care. A key message for other women supported and reinforced their role as active and involved consumers who, in engaging with services, have to stand up for themselves and make their needs and wishes known.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To explore the influencing factors of esophageal cancer in the trunk basin of Dawen river , Shandong province. Methods: A case- control study was carried out: 195 living cases of diagnosed esophageal cancer and 195 controls were matched by age and sex and surveyed by a unified inventory. Results: T he following items could rises the risk of esophageal cancer : hard dry diet, smoke homemade cigarettes, alcohol consumption> 500 ml/ day, relatives with tumor in history ( OR = 51850, OR = 161 158, OR = 111 513, OR = 11 827, respectively ) . While drinking tea may have protective effect against esophageal cancer ( OR = 01 311). Conclusion: The high incidence of esophageal cancer in the area is relative not only to the environment and dietary factors, but also to the family history of esophageal cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To analyze the epidemiological trend of hepatitis B from 1990 to 2007 in Shandong province, and to find the high risk population so as to explore the further control strategy. Methods Based on the routine reporting incidence data of hepatitis B and demographic data of Shandong province, the incidence rates and sex - specific, age - specific incidence rates of hepatitis B were calculated and statistically analyzed in the simple linear regression model. Results The total number of hepatitis B was 437 094, the annual average morbidity was 27132 per 100 000 population during 1990 to 2007. The incidence of men (38142 per 100 000) was higher than that for women (15183 per 100 000) 1The annual incidence rate of hepatitis B indicated an increasing trend for the whole population, while a decreased trend for the 0~9 year - old children p resented in the past 18 years. It showed that the average age of onset moved to the older. Conclusion Young adult men are the high-risk groups for the onset of hepatitis B. For the prevention of hepatitis B, the immunization of hepatitis B vaccine should be enhanced for other groups, especially for the high - risk population on the basis of imp roving the immunization coverage rate for newborns.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background A reliable standardized diagnosis of pneumonia in children has long been difficult to achieve. Clinical and radiological criteria have been developed by the World Health Organization (WHO), however, their generalizability to different populations is uncertain. We evaluated WHO defined chest radiograph (CXRs) confirmed alveolar pneumonia in the clinical context in Central Australian Aboriginal children, a high risk population, hospitalized with acute lower respiratory illness (ALRI). Methods CXRs in children (aged 1-60 months) hospitalized and treated with intravenous antibiotics for ALRI and enrolled in a randomized controlled trial (RCT) of Vitamin A/Zinc supplementation were matched with data collected during a population-based study of WHO-defined primary endpoint pneumonia (WHO-EPC). These CXRs were reread by a pediatric pulmonologist (PP) and classified as pneumonia-PP when alveolar changes were present. Sensitivities, specificities, positive and negative predictive values (PPV, NPV) for clinical presentations were compared between WHO-EPC and pneumonia-PP. Results Of the 147 episodes of hospitalized ALRI, WHO-EPC was significantly less commonly diagnosed in 40 (27.2%) compared to pneumonia-PP (difference 20.4%, 95% CI 9.6-31.2, P < 0.001). Clinical signs on admission were poor predictors for both pneumonia-PP and WHO-EPC; the sensitivities of clinical signs ranged from a high of 45% for tachypnea to 5% for fever + tachypnea + chest-indrawing. The PPV range was 40-20%, respectively. Higher PPVs were observed against the pediatric pulmonologist's diagnosis compared to WHO-EPC. Conclusions WHO-EPC underestimates alveolar consolidation in a clinical context. Its use in clinical practice or in research designed to inform clinical management in this population should be avoided. Pediatr Pulmonol. 2012; 47:386-392. (C) 2011 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Occupational stress research has consistently demonstrated many negative effects of work stressors on employee adjustment (i.e., job-related attitudes and health). Considerable literature also describes potential moderators of this relationship. While research has revealed that different workplace identifications can have significant positive effects on employee adjustment, it has neglected to investigate their potential stress-buffering effects. Based on identity theories, it was predicted that stress-buffering effects of different types of identifications (distal versus proximal) would be revealed when the identification type and employee adjustment outcome type (distal versus proximal) were congruent. Predictions were tested with an employee sample from five human service nonprofit organizations (N = 337). Hierarchical multiple regression analyses revealed that main and moderated effects relating to identification supported the notion that occupational stress would be reduced when there was congruence of distal and proximal identifications and distal and proximal outcome types. However, stress-buffering effects were also found for high identifiers and low identifiers that were not in line with hypotheses posing questions for the definitions of distal and proximal identifications. Findings are discussed in terms of theoretical and practical implications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tissue engineering focuses on the repair and regeneration of tissues through the use of biodegradable scaffold systems that structurally support regions of injury whilst recruiting and/or stimulating cell populations to rebuild the target tissue. Within bone tissue engineering, the effects of scaffold architecture on cellular response have not been conclusively characterized in a controlled-density environment. We present a theoretical and practical assessment of the effects of polycaprolactone (PCL) scaffold architectural modifications on mechanical and flow characteristics as well as MC3T3-E1 preosteoblast cellular response in an in vitro static plate and custom-designed perfusion bioreactor model. Four scaffold architectures were contrasted, which varied in inter-layer lay-down angle and offset between layers, whilst maintaining a structural porosity of 60 ± 5%. We established that as layer angle was decreased (90° vs. 60°) and offset was introduced (0 vs. 0.5 between layers), structural stiffness, yield stress, strength, pore size and permeability decreased, whilst computational fluid dynamics-modeled wall shear stress was increased. Most significant effects were noted with layer offset. Seeding efficiencies in static culture were also dramatically increased due to offset (~45% to ~86%), with static culture exhibiting a much higher seeding efficiency than perfusion culture. Scaffold architecture had minimal effect on cell response in static culture. However, architecture influenced osteogenic differentiation in perfusion culture, likely by modifying the microfluidic environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone defect treatments can be augmented by mesenchymal stem cell (MSC) based therapies. MSC interaction with the extracellular matrix (ECM) of the surrounding tissue regulates their functional behavior. Understanding of these specific regulatory mechanisms is essential for the therapeutic stimulation of MSC in vivo. However, these interactions are presently only partially understood. This study examined in parallel, for the first time, the effects on the functional behavior of MSCs of 13 ECM components from bone, cartilage and hematoma compared to a control protein, and hence draws conclusions for rational biomaterial design. ECM components specifically modulated MSC adhesion, migration, proliferation, and osteogenic differentiation, for example, fibronectin facilitated migration, adhesion, and proliferation, but not osteogenic differentiation, whereas fibrinogen enhanced adhesion and proliferation, but not migration. Subsequently, the integrin expression pattern of MSCs was determined and related to the cell behavior on specific ECM components. Finally, on this basis, peptide sequences are reported for the potential stimulation of MSC functions. Based on the results of this study, ECM component coatings could be designed to specifically guide cell functions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is a comparative study between English and Chinese in expressing repetition and nonrepetition of past actions and in expressing repetition of past nonactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Prostate cancer disseminates to regional lymph nodes, however the molecular mechanisms responsible for lymph node metastasis are poorly understood. The vascular endothelial growth factor (VEGF) ligand and receptor family have been implicated in the growth and spread of prostate cancer via activation of the blood vasculature and lymphatic systems. The purpose of this study was to comprehensively examine the expression pattern of VEGF ligands and receptors in the glandular epithelium, stroma, lymphatic vasculature and blood vessels in prostate cancer. METHODS The localization of VEGF-A, VEGF-C, VEGF-D, VEGF receptor (VEGFR)-1, VEGFR-2, and VEGFR-3 was examined in cancerous and adjacent benign prostate tissue from 52 subjects representing various grades of prostate cancer. RESULTS Except for VEGFR-2, extensive staining was observed for all ligands and receptors in the prostate specimens. In epithelial cells, VEGF-A and VEGFR-1 expression was higher in tumor tissue compared to benign tissue. VEGF-D and VEGFR-3 expression was significantly higher in benign tissue compared to tumor in the stroma and the endothelium of lymphatic and blood vessels. In addition, the frequency of lymphatic vessels, but not blood vessels, was lower in tumor tissue compared with benign tissue. CONCLUSIONS These results suggest that activation of VEGFR-1 by VEGF-A within the carcinoma, and activation of lymphatic endothelial cell VEGFR-3 by VEGF-D within the adjacent benign stroma may be important signaling mechanisms involved in the progression and subsequent metastatic spread of prostate cancer. Thus inhibition of these pathways may contribute to therapeutic strategies for the management of prostate cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Long-term autonomy in robotics requires perception systems that are resilient to unusual but realistic conditions that will eventually occur during extended missions. For example, unmanned ground vehicles (UGVs) need to be capable of operating safely in adverse and low-visibility conditions, such as at night or in the presence of smoke. The key to a resilient UGV perception system lies in the use of multiple sensor modalities, e.g., operating at different frequencies of the electromagnetic spectrum, to compensate for the limitations of a single sensor type. In this paper, visual and infrared imaging are combined in a Visual-SLAM algorithm to achieve localization. We propose to evaluate the quality of data provided by each sensor modality prior to data combination. This evaluation is used to discard low-quality data, i.e., data most likely to induce large localization errors. In this way, perceptual failures are anticipated and mitigated. An extensive experimental evaluation is conducted on data sets collected with a UGV in a range of environments and adverse conditions, including the presence of smoke (obstructing the visual camera), fire, extreme heat (saturating the infrared camera), low-light conditions (dusk), and at night with sudden variations of artificial light. A total of 240 trajectory estimates are obtained using five different variations of data sources and data combination strategies in the localization method. In particular, the proposed approach for selective data combination is compared to methods using a single sensor type or combining both modalities without preselection. We show that the proposed framework allows for camera-based localization resilient to a large range of low-visibility conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reliable robotic perception and planning are critical to performing autonomous actions in uncertain, unstructured environments. In field robotic systems, automation is achieved by interpreting exteroceptive sensor information to infer something about the world. This is then mapped to provide a consistent spatial context, so that actions can be planned around the predicted future interaction of the robot and the world. The whole system is as reliable as the weakest link in this chain. In this paper, the term mapping is used broadly to describe the transformation of range-based exteroceptive sensor data (such as LIDAR or stereo vision) to a fixed navigation frame, so that it can be used to form an internal representation of the environment. The coordinate transformation from the sensor frame to the navigation frame is analyzed to produce a spatial error model that captures the dominant geometric and temporal sources of mapping error. This allows the mapping accuracy to be calculated at run time. A generic extrinsic calibration method for exteroceptive range-based sensors is then presented to determine the sensor location and orientation. This allows systematic errors in individual sensors to be minimized, and when multiple sensors are used, it minimizes the systematic contradiction between them to enable reliable multisensor data fusion. The mathematical derivations at the core of this model are not particularly novel or complicated, but the rigorous analysis and application to field robotics seems to be largely absent from the literature to date. The techniques in this paper are simple to implement, and they offer a significant improvement to the accuracy, precision, and integrity of mapped information. Consequently, they should be employed whenever maps are formed from range-based exteroceptive sensor data. © 2009 Wiley Periodicals, Inc.