203 resultados para Mean intensity
Resumo:
In what is being billed as iiNet versus Hollywood, the Australian internet service provider has come out an apparent winner after the High Court dismissed a copyright infringement case brought by industry movie studios. The case was a final appeal by the industry in its attempts to crack down on internet users infringing copyright by using BitTorrent to download movies.
Resumo:
Residual amplitude modulation (RAM) mechanisms in electro-optic phase modulators are detrimental in applications that require high purity phase modulation of the incident laser beam. While the origins of RAMare not fully understood, measurements have revealed that it depends on the beam properties of the laser as well as the properties of the medium. Here we present experimental and theoretical results that demonstrate, for the first time, the dependence of RAM production in electro-optic phase modulators on beam intensity. The results show an order of magnitude increase in the level of RAM, around 10 dB, with a fifteenfold enhancement in the input intensity from 12 to 190 mW/mm 2. We show that this intensity dependent RAM is photorefractive in origin. © 2012 Optical Society of America.
Resumo:
Photocatalytic water splitting is a process which could potentially lead to commercially viable solar hydrogen production. This thesis uses an engineering perspective to investigate the technology. The effect of light intensity and temperature on photocatalytic water splitting was examined to evaluate the prospect of using solar concentration to increase the feasibility of the process. P25 TiO2 films deposited on conducting glass were used as photocatalyst electrodes and coupled with platinum electrodes which were also deposited on conducting glass. These films were used to form a photocatalysis cell and illuminated with a Xenon arc lamp to simulate solar light at intensities up to 50 suns. They were also tested at temperatures between 20°C and 100°C. The reaction demonstrated a sub-linear relationship with intensity. Photocurrent was proportional to intensity with an exponential value of 0.627. Increasing temperature resulted in an exponential relationship. This proved to follow an Arrhenius relationship with an activation energy of 10.3 kJ mol-1 and a pre-exponential factor of approximately 8.7×103. These results then formed the basis of a mathematical model which extrapolated beyond the range of the experimental tests. This model shows that the loss of efficiency from performing the reaction under high light intensity is offset by the increased reaction rate and efficiency from the associated temperature increase. This is an important finding for photocatalytic water splitting. It will direct future research in system design and materials research and may provide an avenue for the commercialisation of this technology.
Resumo:
The intensity pulsations of a cw 1030 nm Yb:Phosphate monolithic waveguide laser with distributed feedback are described. We show that the pulsations could result from the coupling of the two orthogonal polarization modes through the two photon process of cooperative luminescence. The predictions of the presented theoretical model agree well with the observed behaviour.
Resumo:
Objectives: Malnutrition is common in older hospitalised patients, and barriers to adequate intake in hospital limit the effectiveness of hospital-based nutrition interventions. This pilot study was undertaken to determine whether nutrition-focussed care at discharge and in the early post-hospital period is feasible and acceptable to patients and carers, and improves nutritional status. Design: Prospective cohort study Setting: Internal medicine wards of a tertiary teaching hospital in Brisbane, Australia Participants: Patients aged 65 and older admitted for at least 3 days, identified as malnourished or at risk of malnutrition using Mini Nutritional Assessment (MNA). Interventions: An interdisciplinary discharge team (specialist discharge planning nurse and accredited practicing dietitian) provided nutrition-focussed education, advice, service coordination and follow-up (home visits and telephone) for 6 weeks following hospitalisation Measurements: Nutritional intake, weight, functional status and MNA were recorded 6 and 12 weeks after discharge. Service intensity and changes to care were noted, and hospital readmissions recorded. Service feedback from patients and carers was sought using a brief questionnaire. Results: 12 participants were enrolled during the 6 week pilot (mean age 82 years, 50% male). All received 1-2 home visits, and 3-8 telephone calls. Four participants had new community services arranged, 4 were commenced on oral nutritional supplements, and 7 were referred to community dietetics services for follow-up. Two participants had a decline in MNA score of more than 10% at 12 week follow-up, while the remainder improved by at least 10%. Individualised care including community service coordination was valued by participants. Conclusion: The proposed model of care for older adults was feasible, acceptable to patients and carers, and associated with improved nutritional status at 12 weeks for most participants. The pilot data will be useful for design of intervention trials.
Resumo:
Traditional treatments for weight management have focussed on prescribed dietary restriction or regular exercise, or a combination of both. However recidivism for such prescribed treatments remains high, particularly among the overweight and obese. The aim of this thesis was to investigate voluntary dietary changes in the presence of prescribed mixed-mode exercise, conducted over 16 weeks. With the implementation of a single lifestyle change (exercise) it was postulated that the onerous burden of concomitant dietary and exercise compliance would be reduced, leading to voluntary lifestyle changes in such areas as diet. In addition, the failure of exercise as a single weight loss treatment has been reported to be due to compensatory energy intakes, although much of the evidence is from acute exercise studies, necessitating investigation of compensatory intakes during a long-term exercise intervention. Following 16 weeks of moderate intensity exercise, 30 overweight and obese (BMI≥25.00 kg.m-2) men and women showed small but statistically significant decreases in mean dietary fat intakes, without compensatory increases in other macronutrient or total energy intakes. Indeed total energy intakes were significantly lower for men and women following the exercise intervention, due to the decreases in dietary fat intakes. There was a risk that acceptance of the statistical validity of the small changes to dietary fat intakes may have constituted a Type 1 error, with false rejection of the Null hypothesis. Oro-sensory perceptions to changes in fat loads were therefore investigated to determine whether the measured dietary fat changes were detectable by the human palate. The ability to detect small changes in dietary fat provides sensory feedback for self-initiated dietary changes, but lean and overweight participants were unable to distinguish changes to fat loads of similar magnitudes to that measured in the exercise intervention study. Accuracy of the dietary measurement instrument was improved with the effects of random error (day-to-day variability) minimised with the use of a statistically validated 8-day, multiple-pass, 24 hour dietary recall instrument. However systematic error (underreporting) may have masked the magnitude of dietary change, particularly the reduction in dietary fat intakes. A purported biomarker (plasma Apolipoprotein A-IV) (apoA-IV) was subsequently investigated, to monitor systematic error in self-reported dietary intakes. Changes in plasma apoA-IV concentrations were directly correlated with increased and decreased changes to dietary fat intakes, suggesting that this objective marker may be a useful tool to improve the accuracy of dietary measurement in overweight and obese populations, who are susceptible to dietary underreporting.
Resumo:
The health effects of environmental hazards are often examined using time series of the association between a daily response variable (e.g., death) and a daily level of exposure (e.g., temperature). Exposures are usually the average from a network of stations. This gives each station equal importance, and negates the opportunity for some stations to be better measures of exposure. We used a Bayesian hierarchical model that weighted stations using random variables between zero and one. We compared the weighted estimates to the standard model using data on health outcomes (deaths and hospital admissions) and exposures (air pollution and temperature) in Brisbane, Australia. The improvements in model fit were relatively small, and the estimated health effects of pollution were similar using either the standard or weighted estimates. Spatial weighted exposures would be probably more worthwhile when there is either greater spatial detail in the health outcome, or a greater spatial variation in exposure.
Resumo:
Based on the eigen crack opening displacement (COD) boundary integral equations, a newly developed computational approach is proposed for the analysis of multiple crack problems. The eigen COD particularly refers to a crack in an infinite domain under fictitious traction acting on the crack surface. With the concept of eigen COD, the multiple cracks in great number can be solved by using the conventional displacement discontinuity boundary integral equations in an iterative fashion with a small size of system matrix. The interactions among cracks are dealt with by two parts according to the distances of cracks to the current crack. The strong effects of cracks in adjacent group are treated with the aid of the local Eshelby matrix derived from the traction BIEs in discrete form. While the relatively week effects of cracks in far-field group are treated in the iteration procedures. Numerical examples are provided for the stress intensity factors of multiple cracks, up to several thousands in number, with the proposed approach. By comparing with the analytical solutions in the literature as well as solutions of the dual boundary integral equations, the effectiveness and the efficiencies of the proposed approach are verified.
Resumo:
This paper establishes sufficient conditions to bound the error in perturbed conditional mean estimates derived from a perturbed model (only the scalar case is shown in this paper but a similar result is expected to hold for the vector case). The results established here extend recent stability results on approximating information state filter recursions to stability results on the approximate conditional mean estimates. The presented filter stability results provide bounds for a wide variety of model error situations.
Consecutive days of cold water immersion: effects on cycling performance and heart rate variability.
Resumo:
We investigated performance and heart rate (HR) variability (HRV) over consecutive days of cycling with post-exercise cold water immersion (CWI) or passive recovery (PAS). In a crossover design, 11 cyclists completed two separate 3-day training blocks (120 min cycling per day, 66 maximal sprints, 9 min time trialling [TT]), followed by 2 days of recovery-based training. The cyclists recovered from each training session by standing in cold water (10 °C) or at room temperature (27 °C) for 5 min. Mean power for sprints, total TT work and HR were assessed during each session. Resting vagal-HRV (natural logarithm of square-root of mean squared differences of successive R-R intervals; ln rMSSD) was assessed after exercise, after the recovery intervention, during sleep and upon waking. CWI allowed better maintenance of mean sprint power (between-trial difference [90 % confidence limits] +12.4 % [5.9; 18.9]), cadence (+2.0 % [0.6; 3.5]), and mean HR during exercise (+1.6 % [0.0; 3.2]) compared with PAS. ln rMSSD immediately following CWI was higher (+144 % [92; 211]) compared with PAS. There was no difference between the trials in TT performance (-0.2 % [-3.5; 3.0]) or waking ln rMSSD (-1.2 % [-5.9; 3.4]). CWI helps to maintain sprint performance during consecutive days of training, whereas its effects on vagal-HRV vary over time and depend on prior exercise intensity.
Resumo:
We investigated the effect of hydrotherapy on time-trial performance and cardiac parasympathetic reactivation during recovery from intense training. On three occasions, 18 well-trained cyclists completed 60 min high-intensity cycling, followed 20 min later by one of three 10-min recovery interventions: passive rest (PAS), cold water immersion (CWI), or contrast water immersion (CWT). The cyclists then rested quietly for 160 min with R-R intervals and perceptions of recovery recorded every 30 min. Cardiac parasympathetic activity was evaluated using the natural logarithm of the square root of mean squared differences of successive R-R intervals (ln rMSSD). Finally, the cyclists completed a work-based cycling time trial. Effects were examined using magnitude-based inferences. Differences in time-trial performance between the three trials were trivial. Compared with PAS, general fatigue was very likely lower for CWI (difference [90% confidence limits; -12% (-18; -5)]) and CWT [-11% (-19; -2)]. Leg soreness was almost certainly lower following CWI [-22% (-30; -14)] and CWT [-27% (-37; -15)]. The change in mean ln rMSSD following the recovery interventions (ln rMSSD(Post-interv)) was almost certainly higher following CWI [16.0% (10.4; 23.2)] and very likely higher following CWT [12.5% (5.5; 20.0)] compared with PAS, and possibly higher following CWI [3.7% (-0.9; 8.4)] compared with CWT. The correlations between performance, ln rMSSD(Post-interv) and perceptions of recovery were unclear. A moderate correlation was observed between ln rMSSD(Post-interv) and leg soreness [r = -0.50 (-0.66; -0.29)]. Although the effects of CWI and CWT on performance were trivial, the beneficial effects on perceptions of recovery support the use of these recovery strategies.