66 resultados para Dripping irrigation
Resumo:
Background: The use of large-volume electrolyte balanced solutions as preparation for colonoscopy often results in poor patient compliance and acceptance. The tolerance, safety, and efficacy of high-versus low volume colon-cleansing methods as preparation for colonoscopy in children were compared by randomized operator-blinded trial. Methods: Twenty-nine children ages 3.6-14.6 years had either high-volume nasogastric balanced polyethylene glycol electrolyte lavage (20 ml/kg/h) until the effluent was clear (n = 15), or two oral doses of sodium phosphate solution (22.5-45 ml) separated by oral fluid intake (n = 14). Results: Both preparations were equally effective. The low-volume preparation was better tolerated and caused less discomfort that the high-volume preparation, judging by serial nurse observations. The incidence of abdominal symptoms, diarrhea, sleep disturbance, and vomiting was not significantly different between the two groups. Both groups had a small reduction in mean hematocrit and serum calcium levels. The sodium phosphate preparation caused increases in mean serum sodium concentrations from 140 to 145 mmol/L and serum phosphate concentrations from 1.41 to 2.53 mmol/L. Ten hours after the commencement of the preanesthetic fast, these concentrations had returned to normal. Conclusions: There are advantages in terms of tolerance, discomfort, and case of administration with acceptable colonic cleansing with the use of the less-invasive oral sodium phosphate low-volume colon-cleansing preparation in children. Safe use requires ensuring an adequate oral fluid intake during the preparation time and avoidance of use in patients with renal insufficiency.
Resumo:
The efficacy, adverse reactions, and long-term effects of intestinal lavage treatment with a balanced electrolyte solution (Golytely) was evaluated in patients with cystic fibrosis and distal intestinal obstruction syndrome. Twenty-two patients with cystic fibrosis (mean age 21.8 years, range 14 to 34 years, 15 boys or men) who sough medical attention because of abdominal pain and a mass in the right iliac fossa received Golytely, 5.6 ± 1.9 L (mean ± 1 SD), either orally (n = 14) or via nasogastric tube (n = 8) during 5.6 ± 2.4 hours. No serious side effects occurred. Serum electrolyte values remained within normal limits. Body weight did not change significantly. Minor adverse reactions included bloating (n = 12), nausea (n = 8), vomiting (n = 1), and chills (n = 3). All but one patient reported impressive relief of symptoms and remained pain free for an average of 3 months (range 1 to 19 months). Symptoms of abdominal pain and radiologic signs of fecal impaction assessed before and after lavage both decreased significantly (P < .0001). During follow-up (mean 15.2 months, range 4 to 26 months), 11 patients required a total of 38 (range one to nine) additional doses of Golytely. Seven patients drank the solution at home (21 treatments); only two patients chose a nasogastric tube. In ten patients with symptoms of recurrent distal intestinal obstruction syndrome prior to institution of therapy, duration of hospitalization was significantly reduced by this treatment (5.1 ± 7.6 v 2.3 ± 6.3 hospital days per annum, P < .02). It is concluded that intestinal lavage is a well-accepted, safe, and effective therapy for distal intestinal obstruction syndrome in patients with cystic fibrosis.
Resumo:
Conventional treatment of distal intestinal obstruction syndrome (DIOS) with high doses of pancreatic enzymes, mucolytic agents, and enemas is neither predictably effective nor rapid in action. In 6 cystic fibrosis patients with DIOS a balanced, non-absorbable intestinal lavage solution produced clinical and radiological improvement and striking improvement in DIOS scores. It is suggested that a balanced intestinal lavage solution should be considered as an alternative treatment for DIOS in patients with cystic fibrosis.
Resumo:
Groundwater tables are rising beneath irrigated fields in some areas of the Lower Burdekin in North Queensland, Australia. The soils where this occurs are predominantly sodic clay soils with low hydraulic conductivities. Many of these soils have been treated by applying gypsum or by increasing the salinity of irrigation water by mixing saline groundwater with fresh river water. While the purpose of these treatments is to increase infiltration into the surface soils and improve productivity of the root zone, it is thought that the treatments may have altered the soil hydraulic properties well below the root zone leading to increased groundwater recharge and rising water tables. In this paper we discuss the use of column experiments and HYDRUS modelling, with major ion reaction and transport and soil water chemistry-dependent hydraulic conductivity, to assess the likely depth, magnitude and timing of the impacts of surface soil amelioration on soil hydraulic properties below the root zone and hence groundwater recharge. In the experiments, columns of sodic clays from the Lower Burdekin were leached for extended periods of time with either gypsum solutions or mixed cation salt solutions and change s in hydraulic conductivity were measured. Leaching with a gypsum solution for an extended time period, until the flow rate stabilised, resulted in an approximately twenty fold increase in the hydraulic conductivity when compared with a low salinity, mixed cation solution. HYDRUS modelling was used to high light the role of those factors which might influence the impacts of soil treatment, particularly at depth, including the large amounts of rain during the relatively short wet season and the presence of thick low permeability clay layers.
Resumo:
This book provides an overview of state of the art assessments of water quality; with an understanding how water quality is affected, and improving water quality for irrigation, drinking and recreation activities.