509 resultados para Dominion Power Company


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the design and evaluation of a platform for networks of cameras in low-bandwidth, low-power sensor networks. In our work to date we have investigated two different DSP hardware/software platforms for undertaking the tasks of compression and object detection and tracking. We compare the relative merits of each of the hardware and software platforms in terms of both performance and energy consumption. Finally we discuss what we believe are the ongoing research questions for image processing in WSNs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Journalists in the “new media” era confront important questions as to whether, or how, they adapt their professional practices to a new interactive on-line form that allows citizens to become involved in the news-making process. This paper seeks to re-establish the relevance of traditional journalism practices in the modern era and suggests that they will remain very much a part of the “new journalism” beyond the digital divide. It does so through examining how broadcast journalism interviews challenge authorities in the “public interest”, and suggests, in conclusion, that such practices remain undiminished by the technical, and accompanying social, changes that are driving the “new media”.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1967 Brisbane Repertory Theatre made a decision that was to change the city's cultural landscape in a significant and lasting way. Faced with crippling theatre rental costs, Brisbane Rep. found a realistic solution by converting one of its properties - an old Queenslander - into a unique theatre space. The theatre-in-the box that emerged, aptly called La Boite, opened on 23 June 1967 with a production of John Osborne's Look Back in Anger. This experimental space excited the imagination of a new, younger audience not previously interested in Brisbane Rep's essentially conservative fare. It attracted a new group of directors and actors keen to be part of a changing repertoire that embraced more radical, non-mainstream productions, some of which were of Australian plays. The decade after 1967 was a period of change and development unprecedented in La Boite's history. Since then the company has sustained and grown its commitment to Australian plays and the commissioning of new works. To what extent was this most significance moment in La Boite's transformational journey influenced by southern 'new waves' of change? With the benefit of hindsight, it is now time for a re-consideration of Brisbane's distinctive contribution to the New Wave.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article is to highlight the conflict in the policy objectives of subs 46(1) and subs 46(1AA) of the Trade Practices Act 1974 (Cth) (TPA). The policy objective of subs 46(1) is to promote competition and efficient markets for the benefit of consumers (consumer welfare standard). It does not prohibit corporations with substantial market power using cost savings arising from efficiencies such economies of scale or scope, to undercut small business competitors The policy objective of 46(1AA), on the other hand, is to protect small business operators from price discounting by their larger competitors.. Unlike subs 46(1), it does not contain a ‘taking advantage’ element. It is argued that subs 46(1AA) may harm consumer welfare by having a chilling effect on price competition if this would harm small business competitors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high voltage power converter is presented in this paper and is based on a Capacitor-Diode Voltage Multiplier (CDVM) supplied through an inverter. This power converter has the capabilities of generating variable high DC voltage with improved transient response. The simulation results which are presented in this paper verify that due to its fast transient response, this converter can be used as a high DC voltage source in many applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high voltage pulsed power supply is proposed in this paper based on oscillation between an inductor and a capacitor in an LC circuit. A two-leg resonant circuit, supplied through an inverter with an alternative voltage waveform, can generate output voltage up to four times an input voltage magnitude. Bipolar and unipolar modulations are used in a single phase inverter to analyse their effects on the proposed resonant converter. Simulations have been carried out to evaluate the proposed topology and control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a high voltage pulsed power system based on low voltage switch-capacitor units connected to a current source for several applications such as plasma systems. A buck-boost converter topology is used to utilize the current source and a series of low voltage switch-capacitor units is connected to the current source in order to provide high voltage with high voltage stress (dv/dt) as demanded by loads. This pulsed power converter is flexible in terms of energy control, in that the stored energy in the current source can be adjusted by changing the current magnitude to significantly improve the efficiency of various systems with different requirements. Output voltage magnitude and stress (dv/dt) can be controlled by a proper selection of components and control algorithm to turn on and off switching devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electromagnetic compatibility of power electronic systems becomes an engineering discipline and it should be considered at the beginning stage of a design. Thus, a power electronics design becomes more complex and challenging and it requires a good communication between EMI and Power electronics experts. Three major issues in designing a power electronic system are Losses, EMI and Harmonics. These issues affect system cost, size, efficiency and quality and it is a tradeoff between these factors when we design a power converter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An algorithm based on the concept of Kalman filtering is proposed in this paper for the estimation of power system signal attributes, like amplitude, frequency and phase angle. This technique can be used in protection relays, digital AVRs, DSTATCOMs, FACTS and other power electronics applications. Furthermore this algorithm is particularly suitable for the integration of distributed generation sources to power grids when fast and accurate detection of small variations of signal attributes are needed. Practical considerations such as the effect of noise, higher order harmonics, and computational issues of the algorithm are considered and tested in the paper. Several computer simulations are presented to highlight the usefulness of the proposed approach. Simulation results show that the proposed technique can simultaneously estimate the signal attributes, even if it is highly distorted due to the presence of non-linear loads and noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an analysis of phasor measurement method for tracking the fundamental power frequency to show if it has the performance necessary to cope with the requirements of power system protection and control. In this regard, several computer simulations presenting the conditions of a typical power system signal especially those highly distorted by harmonics, noise and offset, are provided to evaluate the response of the Phasor Measurement (PM) technique. A new method, which can shorten the delay of estimation, has also been proposed for the PM method to work for signals free of even-order harmonics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a method for power flow control between utility and microgrid through back-to-back converters, which facilitates desired real and reactive power flow between utility and microgrid. In the proposed control strategy, the system can run in two different modes depending on the power requirement in the microgrid. In mode-1, specified amount of real and reactive power are shared between the utility and the microgrid through the back-to-back converters. Mode-2 is invoked when the power that can be supplied by the DGs in the microgrid reaches its maximum limit. In such a case, the rest of the power demand of the microgrid has to be supplied by the utility. An arrangement between DGs in the microgrid is proposed to achieve load sharing in both grid connected and islanded modes. The back-to-back converters also provide total frequency isolation between the utility and the microgrid. It is shown that the voltage or frequency fluctuation in the utility side has no impact on voltage or power in microgrid side. Proper relay-breaker operation coordination is proposed during fault along with the blocking of the back-to-back converters for seamless resynchronization. Both impedance and motor type loads are considered to verify the system stability. The impact of dc side voltage fluctuation of the DGs and DG tripping on power sharing is also investigated. The efficacy of the proposed control ar-rangement has been validated through simulation for various operating conditions. The model of the microgrid power system is simulated in PSCAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes control methods for proper load sharing between parallel converters connected in a microgrid and supplied by distributed generators (DGs). It is assumed that the microgrid spans a large area and it supplies loads in both in grid connected and islanded modes. A control strategy is proposed to improve power quality and proper load sharing in both islanded and grid connected modes. It is assumed that each of the DGs has a local load connected to it which can be unbalanced and/or nonlinear. The DGs compensate the effects of unbalance and nonlinearity of the local loads. Common loads are also connected to the microgrid, which are supplied by the utility grid under normal conditions. However during islanding, each of the DGs supplies its local load and shares the common load through droop characteristics. Both impedance and motor loads are considered to verify the system response. The efficacy of the controller has been validated through simulation for various operating conditions using PSCAD. It has been found through simulation that the total Harmonic Distortion (THD) of the of the microgrid voltage is about 10% and the negative and zero sequence component are around 20% of the positive sequence component before compensation. After compensation, the THD remain below 0.5%, whereas, negative and zero sequence components of the voltages remain below 0.02% of the positive sequence component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since its genesis in 1925, La Boite has never been afraid of change. Despite controversies, crises and crippling set-backs that should have closed its stage doors many times, La Boite - which began life as the Brisbane Repertory Theatre Society - has proved itself an extraordinary survivor. When the opportunity came to build its own theatre, its inspired choice of theatre-in-the-round gave Brisbane an iconic performance space that attracted a whole new generation of actors, directors and designers and placed La Boite at the forefront of contemporary theatre practice. The place, in Katharine Brisbane’s words, “to see the red meat of theatre”. Always enterprising, with gritty determination it became a professional theatre company of national significance; and early in the new millennium triumphantly re-located to its new home at The Roundhouse Theatre. La Boite –The Story of an Australian Theatre Company both interrogates and celebrates the history of Queensland’s oldest theatre company. Highlighting the roles key people played in its evolution – particularly four remarkable women – Christine Comans explores La Boite’s colourful past, its cultural significance to Brisbane, and its vibrant and enduring role in the nation’s theatrical history.