135 resultados para Architecture and solar radiation Queensland
Resumo:
The effective daylighting of multistorey commercial building interiors poses an interesting problem for designers in Australia’s tropical and subtropical context. Given that a building exterior receives adequate sun and skylight as dictated by location-specific factors such as weather, siting and external obstructions; then the availability of daylight throughout its interior is dependant on certain building characteristics: the distance from a window façade (room depth), ceiling or window head height, window size and the visible transmittance of daylighting apertures. The daylighting of general stock, multistorey commercial buildings is made difficult by their design limitations with respect to some of these characteristics. The admission of daylight to these interiors is usually exclusively by vertical windows. Using conventional glazing, such windows can only admit sun and skylight to a depth of approximately 2 times the window height. This penetration depth is typically much less than the depth of the office interiors, so that core areas of these buildings receive little or no daylight. This issue is particularly relevant where deep, open plan office layouts prevail. The resulting interior daylight pattern is a relatively narrow perimeter zone bathed in (sometimes too intense) light, contrasted with a poorly daylit core zone. The broad luminance range this may present to a building occupant’s visual field can be a source of discomfort glare. Furthermore, the need in most tropical and subtropical regions to restrict solar heat gains to building interiors for much of the year has resulted in the widespread use of heavily tinted or reflective glazing on commercial building façades. This strategy reduces the amount of solar radiation admitted to the interior, thereby decreasing daylight levels proportionately throughout. However this technique does little to improve the way light is distributed throughout the office space. Where clear skies dominate weather conditions, at different times of day or year direct sunlight may pass unobstructed through vertical windows causing disability or discomfort glare for building occupants and as such, its admission to an interior must be appropriately controlled. Any daylighting system to be applied to multistorey commercial buildings must consider these design obstacles, and attempt to improve the distribution of daylight throughout these deep, sidelit office spaces without causing glare conditions. The research described in this thesis delineates first the design optimisation and then the actual prototyping and manufacture process of a daylighting device to be applied to such multistorey buildings in tropical and subtropical environments.
Resumo:
Sustainability Declarations were introduced by the Queensland State Government on 1 January 2010 as a compulsory measure for all dwelling sales. The purpose of this policy decision was to improve the relevance of sustainability in the home ownership decision making process. This paper assesses the initial impact of this initiative over its first year in operation. In partnership with the Real Estate Institute of Queensland, real estate agents and salespeople in Queensland were surveyed to determine what impact the Sustainability Declaration has had on home buyer decision making. The level of compliance by the real estate industry was also reviewed. These preliminary findings indicate a high level of compliance from the real estate industry, however results confirm that sustainability is yet to become a criterion of relevance to the majority of home buyers in Queensland. The Sustainability Declarations are a first step in raising awareness in home owners of the importance of sustainability in housing. Further monitoring of this impact will be carried out over time.
Resumo:
As solar hydrogen is a sustainable and environmental friendly energy carrier, it is considered to take the place of fossil fuels in the near future. Solar hydrogen can be generated by splitting of water under solar light illumination. In this study, the use of nanostructured hematite thin-film electrodes in photocatalytic water splitting was investigated. Hematite (á-Fe2O3) has a narrow band-gap of 2.2 eV, which is able to utilise approximately 40% of solar radiation. However, poor photoelectrochemical performance is observed for hematite due to low electrical conductivity and a high rate of electron-hole recombination. An extensive review of useful measures taken to overcoming the disadvantages of hematite so as to enhance its performance was presented including thin-film structure, nanostructuring, doping, etc. Since semiconductoring materials which exhibit an inverse opal structure are expected to have a high surface-volume ratio, unique optical characteristics and a shorter distance for photogenerated holes to travel to the electrode/electrolyte interface, inverse opals of hematite thin films deposited on FTO glass substrate were successfully prepared by doctor blading using PMMA as a template. However, due to the poor adhesion of the films, an acidic medium (i.e., 2 M HCl) was employed to significantly enhance the adhesion of the films, which completely destroyed the inverse opal structure. Therefore, undoped, Ti and Zn-doped hematite thin films deposied on FTO glass substrate without an inverse opal structure were prepared by doctor blading and spray pyrolysis and characterised using SEM, EDX, XRD, TGA, UV-Vis spectroscopy and photoelectrochemical measurements. Regarding the doped hematite thin films prepared by doctor blading, the photoelectrochemical activity of the hematite photoelectrodes was improved by incorporation of Ti, most likely owing to the increased electrical conductivity of the films, the stabilisation of oxygen vacancies by Ti4+ ions and the increased electric field of the space charge layer. A highest photoresponse was recorded in case of 2.5 at.% Ti which seemed to be an optimal concentration. The effect of doping content, thickness, and calcination temperature on the performance of the Ti-doped photoelectrodes was investigated. Also, the photoactivity of the 2.5 at.% Ti-doped samples was examined in two different types of electrochemical cells. Zn doping did not enhance the photoactivity of the hematite thin films though Zn seemed to enhance the hole transport due to the slow hole mobility of hematite which could not be overcome by the enhancement. The poor performance was also obtained for the Ti-doped samples prepared by spray pyrolysis, which appeared to be a result of introduction of impurities from the metallic parts of the spray gun in an acidic medium. Further characterisation of the thin-film electrodes is required to explain the mechanism by which enhanced performance was obtained for Ti-doped electrodes (doctor blading) and poor photoactivity for Zn and Ti-doped samples which were synthesised by doctor blading and spray pyrolysis, respectively. Ti-doped hematite thin films will be synthesised in another way, such as dip coating so as to maintain an inverse opal structure as well as well adhesion. Also, a comparative study of the films will be carried out.
Resumo:
The development of the Learning and Teaching Academic Standards Statement for Architecture (the Statement) centred on requirements for the Master of Architecture and proceeded alongside similar developments in the building and construction discipline under the guidance and support of the Australian Deans of Built Environment and Design (ADBED). Through their representation of Australian architecture programs, ADBED have provided high-level leadership for the Learning and Teaching Academic Standards Project in Architecture (LTAS Architecture). The threshold learning outcomes (TLOs), the description of the nature and extent of the discipline, and accompanying notes were developed through wide consultation with the discipline and profession nationally. They have been considered and debated by ADBED on a number of occasions and have, in their fi nal form, been strongly endorsed by the Deans. ADBED formed the core of the Architecture Reference Group (chaired by an ADBED member) that drew together representatives of every peak organisation for the profession and discipline in Australia. The views of the architectural education community and profession have been provided both through individual submissions and the voices of a number of peak bodies. Over two hundred individuals from the practising profession, the academic workforce and the student cohort have worked together to build consensus about the capabilities expected of a graduate of an Australian Master of Architecture degree. It was critical from the outset that the Statement should embrace the wisdom of the greater ‘tribe’, should ensure that graduates of the Australian Master of Architecture were eligible for professional registration and, at the same time, should allow for scope and diversity in the shape of Australian architectural education. A consultation strategy adopted by the Discipline Scholar involved meetings and workshops in Perth, Melbourne, Sydney, Canberra and Brisbane. Stakeholders from all jurisdictions and most universities participated in the early phases of consultation through a series of workshops that concluded late in October 2010. The Draft Architecture Standards Statement was formed from these early meetings and consultation in respect of that document continued through early 2011. This publication represents the outcomes of work to establish an agreed standards statement for the Master of Architecture. Significant further work remains to ensure the alignment of professional accreditation and recognition procedures with emerging regulatory frameworks cascading from the establishment of the Tertiary Education Quality and Standards Agency (TEQSA). The Australian architecture community hopes that mechanisms can be found to integrate TEQSA’s quality assurance purpose with well-established and understood systems of professional accreditation to ensure the good standing of Australian architectural education into the future. The work to build renewed and integrated quality assurance processes and to foster the interests of this project will continue, for at least the next eighteen months, under the auspices of Australian Learning and Teaching Council (ALTC)-funded Architecture Discipline Network (ADN), led by ADBED and Queensland University of Technology. The Discipline Scholar gratefully acknowledges the generous contributions given by those in stakeholder communities to the formulation of the Statement. Professional and academic colleagues have travelled and gathered to shape the Standards Statement. Debate has been vigorous and spirited and the Statement is rich with the purpose, critical thinking and good judgement of the Australian architectural education community. The commitments made to the processes that have produced this Statement reflect a deep and abiding interest by the constituency in architectural education. This commitment bodes well for the vibrancy and productivity of the emergent Architecture Discipline Network (ADN). Endorsement, in writing, was received from the Australian Institute of Architects National Education Committee (AIA NEC): The National Education Committee (NEC) of the Australian Institute of Architects thank you for your work thus far in developing the Learning and Teaching Academic Standards for Architecture In particular, we acknowledge your close consultation with the NEC on the project along with a comprehensive cross-section of the professional and academic communities in architecture. The TLOs with the nuanced levels of capacities – to identify, develop, explain, demonstrate etc – are described at an appropriate level to be understood as minimum expectations for a Master of Architecture graduate. The Architects Accreditation Council of Australia (AACA) has noted: There is a clear correlation between the current processes for accreditation and what may be the procedures in the future following the current review. The requirement of the outcomes as outlined in the draft paper to demonstrate capability is an appropriate way of expressing the measure of whether the learning outcomes have been achieved. The measure of capability as described in the outcome statements is enhanced with explanatory descriptions in the accompanying notes.
Resumo:
This article is a brief introduction to the total solar eclipse Wed 14 November 2012 in north Queensland that will be seen in a narrow strip of land just 140 km wide in the vicinity of Cairns.
Resumo:
The exchange between the body and architecture walks a fine line between violence and pleasure. It is through the body that the subject engages with the architectural act, not via thought or reason, but through action. The materiality of architecture is the often the catalyst for some intense association; the wall that defines gender or class, the double bolted door that incarcerates, the enclosed privacy of the bedroom to the love affair. Architecture is the physical manifestation of Lefebvre’s inscribed space. It enacts the social and political systems through bodily occupation. Architecture, when tested by the occupation of bodies, anchors ideology in both space and time. The architect’s script can be powerful when rehearsed honestly to the building’s intentions and just as beautiful when rebuked by the act of protest or unfaithful occupation. This research examines this fine line of violence and pleasure in architecture through performance, in the work of Bryony Lavin’s play Stockholm and Revolving Door by Allora & Calzadilla as part of the recent Kaldor Public Art Projects exhibition 13 Rooms in Sydney. The research is underpinned by the work of Architect and theorist, Bernard Tschumi in his two essays, Violence of Architecture and The Pleasure of Architecture. Studying architecture through the lens of performance shifts the focus of examination from pure thought to the body; because architecture is occupied through the body and not the mind.
Resumo:
Research Statement: In 2011 The State Library of Queensland in collaboration with Queensland University of Technology School of Design held a screening of six student urban films shot on location in several inner-city sites under my supervision. The films are now a permanent "exhibit" on The Edge State Library electronic site. The students were directed to explore the realist film ethos, which forms a platform for the research project, in its focus on the nonrepresentational aesthetics of the street, the unfinished and the sensory. The research demonstrates that film is a powerful instrument for the urban imaginary, for screening the city.
Resumo:
Singapore is located at the equator, with abundant supply of solar radiation, relatively high ambient temperature and relative humidity throughout the year. The meteorological conditions of Singapore are favourable for efficient operation of solar energy based systems. Solar assisted heat pump systems are built on the roof-top of National University of Singapore’s Faculty of Engineering. The objectives of this study include the design and performance evaluation of a solar assisted heat-pump system for water desalination, water heating and drying of clothes. Using MATLAB programming language, a 2-dimensional simulation model has been developed to conduct parametric studies on the system. The system shows good prospect to be implemented in both industrial and residential applications and would give new opportunities in replacing conventional energy sources with green renewable energy.
Resumo:
This is a theoretical investigation seeking to learn more about architecture by looking at architectural practice through another discipline. In this research architecture is investigated by examining its relationship with bodies through performance and theatre set design. This thesis aims to build on existing architectural theory, in which an absence of discourse on the body has been identified, by analysing representations of architecture and the body in performance. The research specifically examines the relationship between the body, architecture and authority in performance through the analysis of several performance works.
Resumo:
This thesis added new insight to research knowledge about the role that season and ultraviolet radiation (UV) exposure during pregnancy has on children's temperament and behaviours, using a nation-wide longitudinal study. It was found that young children born in summer months are likely to have problematic behaviours. The thesis also found that summer-born children are likely to receive lowest levels of UV exposure during the gestational period. Finally, this work showed that low gestational UV exposure is associated with an increased risk of behavioural problems in children.
Resumo:
The dynamic interaction between building systems and external climate is extremely complex, involving a large number of difficult-to-predict variables. In order to study the impact of global warming on the built environment, the use of building simulation techniques together with forecast weather data are often necessary. Since all building simulation programs require hourly meteorological input data for their thermal comfort and energy evaluation, the provision of suitable weather data becomes critical. Based on a review of the existing weather data generation models, this paper presents an effective method to generate approximate future hourly weather data suitable for the study of the impact of global warming. Depending on the level of information available for the prediction of future weather condition, it is shown that either the method of retaining to current level, constant offset method or diurnal modelling method may be used to generate the future hourly variation of an individual weather parameter. An example of the application of this method to the different global warming scenarios in Australia is presented. Since there is no reliable projection of possible change in air humidity, solar radiation or wind characters, as a first approximation, these parameters have been assumed to remain at the current level. A sensitivity test of their impact on the building energy performance shows that there is generally a good linear relationship between building cooling load and the changes of weather variables of solar radiation, relative humidity or wind speed.
Resumo:
Objective: To define characteristics of all-terrain vehicle (ATV) crashes occurring in north Queensland from March 2004 till June 2007 with the exploration of associated risk factors. Design: Descriptive analysis of ATV crash data collected by the Rural and Remote Road Safety Study. Setting: Rural and remote north Queensland. Participants: Forty-two ATV drivers and passengers aged 16 years or over hospitalised at Atherton, Cairns, Mount Isa or Townsville for at least 24 hours as a result of a vehicle crash. Main outcome measures: Demographics of participants, reason for travel, nature of crash, injuries sustained and risk factors associated with ATV crash. Results: The majority of casualties were men aged 16–64. Forty-one per cent of accidents occurred while performing agricultural tasks. Furthermore, 39% of casualties had less than one year’s experience riding ATVs. Over half the casualties were not wearing a helmet at the time of the crash. Common injuries were head and neck and upper limb injuries. Rollovers tended to occur while performing agricultural tasks and most commonly resulted in multiple injuries. Conclusions: Considerable trauma results from ATV crashes in rural and remote north Queensland. These crashes are not included in most general vehicle crash data sets, as they are usually limited to events occurring on public roads. Minimal legislation and regulation currently applies to ATV use in agricultural, recreational and commercial settings. Legislation on safer design of ATVs and mandatory courses for riders is an essential part of addressing the burden of ATV crashes on rural and remote communities.