707 resultados para Uruguayan cultural field


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A health workforce ready for safe practice is a government priority, and particularly critical to support indigenous communities closing ‘the gap’. Increased pressure exists on dietetic training programs for quality placements, with fewer opportunities for immersion in Aboriginal and Torres Strait Islander communities to demonstrate cultural competence. In 2012, Queensland University of Technology established a partnership with Apunipima Cape York Health Council with 56 weeks of dietetic placement for 8 students provided to achieve these aims. Clinical practice in Community Public Health Nutrition (CPHN) was structured in a standard 6 week placement, with Individual Case Management (ICM) and Foodservice Management (FSM) integrated across 8 weeks (4 each), with an additional 2 weeks ICM prior in a metropolitan indigenous health service. Students transitioned from urban to rural then remote sites, with new web-based technologies used for support. Strong learning opportunities were provided, with CPHN projects in antenatal and child health, FSM on standardisation of procedures in a 22 bed health facility, and ICM exposing students to a variety of cases via hospital in/outpatients, general clinics and remote community outreach. Supervisor focus group evaluation was positive, with CPHN and FSM enhancing capacity of service. Student focus group evaluation revealed placements exceeded expectations, with rating high, and strong confidence in cultural competence described. Students debriefed final and third year cohorts on their experiences, with increased awareness and enthusiasm for work with indigenous communities indicated by groups. With the success of this partnership, placements are continuing 2013, and new boundaries in dietetic training established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Falling prices have led to an ongoing spread of public displays in urban areas. Still, they mostly show passive content such as commercials and digital signage. At the same time, technological advances have enabled the creation of interactive displays potentially increasing their attractiveness for the audience, e.g. through providing a platform for civic discourse. This poses considerable challenges, since displays need to communicate the opportunity to engage, motivate the audience to do so, and be easy to use. In this paper we present Vote With Your Feet, a hyperlocal public polling tool for urban screens allowing users to express their opinions. Similar to vox populi interviews on TV or polls on news websites, the tool is meant to reflect the mindset of the community on topics such as current affairs, cultural identity and local matters. It is novel in that it focuses on a situated civic discourse and provides a tangible user interface, tackling the mentioned challenges. It shows one Yes/No question at a time and enables users to vote by stepping on one of two tangible buttons on the ground. This user interface was introduced to attract people’s attention and to lower participation barriers. Our field study showed that Vote With Your Feet is perceived as inviting and that it can spark discussions among co-located people.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High power, high frequency pulsed electric fields known as pulsed power (PP) has been applied recently in biology and medicine. However, little attention has been paid to investigate the application of pulse power in musculoskeletal system and its possible effect on functional behavior and biomechanical properties of bone tissue. This paper presents the first research investigating whether or not PP can be applied safely on bone tissue as a stimuli and what will be the possible effect of these signals on the characteristics of cortical bone by comparing the mechanical properties of this type of bone pre and post expose to PP and in comparison with the control samples. A positive buck‑boost converter was applied to generate adjustable high voltage, high frequency pulses (up to 500 V and 10 kHz). The functional behavior of bone in response to pulse power excitation was elucidated by applying compressive loading until failure. The stiffness, failure stress (strength) and the total fracture energy (bone toughness) were determined as a measure of the main bone characteristics. Furthermore, an ultrasonic technique was applied to determine and comprise bone elasticity before and after pulse power stimulation. The elastic property of cortical bone samples appeared to remain unchanged following exposure to pulse power excitation for all three orthogonal directions obtained from ultrasonic technique and similarly from the compression test. Nevertheless, the compressive strength and toughness of bone samples were increased when they were exposed to 66 h of high power pulsed electromagnetic field compared to the control samples. As the toughness and the strength of the cortical bone tissue are directly associated with the quality and integrity of the collagen matrix whereas its stiffness is primarily related to bone mineral content these overall results may address that although, the pulse power stimulation can influence the arrangement or the quality of the collagen network causing the bone strength and toughness augmentation, it apparently did not affect the mineral phase of the cortical bone material. The results also confirmed that the indirect application of high power pulsed electric field at 500 V and 10 kHz through capacitive coupling method was safe and did not destroy the bone tissue construction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rise of Web 2.0 has pushed the amateur to the forefront of public discourse, public policy and media scholarship. Typically non-salaried, non-specialist and untrained in media production, amateur producers are now seen as key drivers of the creative economy. But how do the activities of citizen journalists, fan fiction writers and bedroom musicians connect with longer traditions of extra-institutional media production? This edited collection provides a much-needed interdisciplinary contextualisation of amateur media before and after Web 2.0. Surveying the institutional, economic and legal construction of the amateur media producer via a series of case studies, it features contributions from experts in the fields of law, economics and media studies based in the UK, Europe and Singapore. Each section of the book contains a detailed case study on a selected topic, followed by two further pieces providing additional analysis and commentary. Using an extraordinary array of case studies and examples, from YouTube to online games, from subtitling communities to reality TV, the book is neither a celebration of amateur production nor a denunciation of the demise of professional media industries. Rather, this book presents a critical dialogue across law and the humanities, exploring the dynamic tensions and interdependencies between amateur and professional creative production. This book will appeal to both academics and students of intellectual property and media law, as well as to scholars and students of economics, media, cultural and internet studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To explore social equity, health planning, regulatory and ethical dilemmas in responding to a pandemic influenza (H5N1) outbreak, and the adequacy of protocols and standards such as the International Health Regulations (2005). APPROACH This paper analyses the role of legal and ethical considerations for pandemic preparedness, including an exploration of the relevance of cross-jurisdictional and cross-cultural perspectives in assessing the validity of goals for harmonisation of laws and policies both within and between nations. Australian and international experience is reviewed in various areas, including distribution of vaccines during a pandemic, the distribution of authority between national and local levels of government, and global and regional equity issues for poorer countries. CONCLUSION This paper finds that questions such as those of distributional justice (resource allocation) and regulatory frameworks raise important issues about the cultural and ethical acceptability of planning measures. Serious doubt is cast on a 'one size fits all' approach to international planning for managing a pandemic. It is concluded that a more nuanced approach than that contained in international guidelines may be required if an effective response is to be constructed internationally. IMPLICATIONS The paper commends the wisdom of reliance on 'soft law', international guidance that leaves plenty of room for each nation to construct its response in conformity with its own cultural and value requirements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To explore social equity, health planning, regulatory and ethical dilemmas in responding to a pandemic influenza (H5N1) outbreak, and the adequacy of protocols and standards such as the International Health Regulations (2005). Approach This paper analyses the role of legal and ethical considerations for pandemic preparedness, including an exploration of the relevance of cross-jurisdictional and cross-cultural perspectives in assessing the validity of goals for harmonisation of laws and policies both within and between nations. Australian and international experience is reviewed in various areas, including distribution of vaccines during a pandemic, the distribution of authority between national and local levels of government, and global and regional equity issues for poorer countries. Conclusion This paper finds that questions such as those of distributional justice (resource allocation) and regulatory frameworks raise important issues about the cultural and ethical acceptability of planning measures. Serious doubt is cast on a ‘one size fits all’ approach to international planning for managing a pandemic. It is concluded that a more nuanced approach than that contained in international guidelines may be required if an effective response is to be constructed internationally. Implications The paper commends the wisdom of reliance on ‘soft law’, international guidance that leaves plenty of room for each nation to construct its response in conformity with its own cultural and value requirements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new form of media installation combining image, multi-channel sound and internally lit objects into a mysterious, deep image plane. Staged on the very edge of spectrum blackout, and moving into the deep of night, Version 1 (Night Rage) for ISEA 2013 examined the many shades of 'nocturnal', threats to night biodiversity and the myriad myths and stories that have shaped our cultural understandings of life after light. Barely recognisable images float within landscapes of media, noise and sound as the work asserts a profound resistance to today's all consuming media mesh. Version 2 (Night Fall) for the Queensland State Museum examined contemporary ideas around the ‘night’ and the 'nocturnal'. Beginning with the dark myths and stories that have long shaped our cultural understandings of life after light, NIGHT FALL considers how fearful ideas have often underpinned actions that continue to reduce Australia’s extraordinary night biodiversity. Today’s growing hostility towards Australia’s ancient, iconic flying foxes - who have been quietly pollinating our forests for millennia - hints at just how far we have yet to travel in our thinking. Enter the darkened tunnel to experience mysterious, edge-of-perception 3D forms, enhanced by a range of cinematic, illusionary and animatronic techniques, and become immersed in a strangely familiar sound track based upon seasonal field recordings made after dark, sourced from across the eastern coast of Queensland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pitfall is an unapparent source of trouble or danger; a hidden hazard: Today we all face, or will soon be facing ecological pitfalls of many kinds. ‘Pitfall’ is a continually-evolving artwork built from multiple screens, a tabletop landscape mapped with projections, fibre optics, 3D spatial sound and infrared night imagery. It builds upon ideas, recordings and cross-disciplinary processes developed during my 2012-13 ANAT Synapse Art-Science residency, with the Australian Wildlife Conservancy (AWC), Australia’s largest private-sector conservation organisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The consistency of measuring small field output factors is greatly increased by reporting the measured dosimetric field size of each factor, as opposed to simply stating the nominal field size [1] and therefore requires the measurement of cross-axis profiles in a water tank. However, this makes output factor measurements time consuming. This project establishes at which field size the accuracy of output factors are not affected by the use of potentially inaccurate nominal field sizes, which we believe establishes a practical working definition of a ‘small’ field. The physical components of the radiation beam that contribute to the rapid change in output factor at small field sizes are examined in detail. The physical interaction that dominates the cause of the rapid dose reduction is quantified, and leads to the establishment of a theoretical definition of a ‘small’ field. Methods Current recommendations suggest that radiation collimation systems and isocentre defining lasers should both be calibrated to permit a maximum positioning uncertainty of 1 mm [2]. The proposed practical definition for small field sizes is as follows: if the output factor changes by ±1.0 % given a change in either field size or detector position of up to ±1 mm then the field should be considered small. Monte Carlo modelling was used to simulate output factors of a 6 MV photon beam for square fields with side lengths from 4.0 to 20.0 mm in 1.0 mm increments. The dose was scored to a 0.5 mm wide and 2.0 mm deep cylindrical volume of water within a cubic water phantom, at a depth of 5 cm and SSD of 95 cm. The maximum difference due to a collimator error of ±1 mm was found by comparing the output factors of adjacent field sizes. The output factor simulations were repeated 1 mm off-axis to quantify the effect of detector misalignment. Further simulations separated the total output factor into collimator scatter factor and phantom scatter factor. The collimator scatter factor was further separated into primary source occlusion effects and ‘traditional’ effects (a combination of flattening filter and jaw scatter etc.). The phantom scatter was separated in photon scatter and electronic disequilibrium. Each of these factors was plotted as a function of field size in order to quantify how each affected the change in small field size. Results The use of our practical definition resulted in field sizes of 15 mm or less being characterised as ‘small’. The change in field size had a greater effect than that of detector misalignment. For field sizes of 12 mm or less, electronic disequilibrium was found to cause the largest change in dose to the central axis (d = 5 cm). Source occlusion also caused a large change in output factor for field sizes less than 8 mm. Discussion and conclusions The measurement of cross-axis profiles are only required for output factor measurements for field sizes of 15 mm or less (for a 6 MV beam on Varian iX linear accelerator). This is expected to be dependent on linear accelerator spot size and photon energy. While some electronic disequilibrium was shown to occur at field sizes as large as 30 mm (the ‘traditional’ definition of small field [3]), it has been shown that it does not cause a greater change than photon scatter until a field size of 12 mm, at which point it becomes by far the most dominant effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Total scatter factor (or output factor) in megavoltage photon dosimetry is a measure of relative dose relating a certain field size to a reference field size. The use of solid phantoms has been well established for output factor measurements, however to date these phantoms have not been tested with small fields. In this work, we evaluate the water equivalency of a number of solid phantoms for small field output factor measurements using the EGSnrc Monte Carlo code. Methods The following small square field sizes were simulated using BEAMnrc: 5, 6, 7, 8, 10 and 30 mm. Each simulated phantom geometry was created in DOSXYZnrc and consisted of a silicon diode (of length and width 1.5 mm and depth 0.5 mm) submersed in the phantom at a depth of 5 g/cm2. The source-to-detector distance was 100 cm for all simulations. The dose was scored in a single voxel at the location of the diode. Interaction probabilities and radiation transport parameters for each material were created using custom PEGS4 files. Results A comparison of the resultant output factors in the solid phantoms, compared to the same factors in a water phantom are shown in Fig. 1. The statistical uncertainty in each point was less than or equal to 0.4 %. The results in Fig. 1 show that the density of the phantoms affected the output factor results, with higher density materials (such as PMMA) resulting in higher output factors. Additionally, it was also calculated that scaling the depth for equivalent path length had negligible effect on the output factor results at these field sizes. Discussion and conclusions Electron stopping power and photon mass energy absorption change minimally with small field size [1]. Also, it can be seen from Fig. 1 that the difference from water decreases with increasing field size. Therefore, the most likely cause for the observed discrepancies in output factors is differing electron disequilibrium as a function of phantom density. When measuring small field output factors in a solid phantom, it is important that the density is very close to that of water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Due to their high spatial resolution diodes are often used for small field relative output factor measurements. However, a field size specific correction factor [1] is required and corrects for diode detector over-response at small field sizes. A recent Monte Carlo based study has shown that it is possible to design a diode detector that produces measured relative output factors that are equivalent to those in water. This is accomplished by introducing an air gap at the upstream end of the diode [2]. The aim of this study was to physically construct this diode by placing an ‘air cap’ on the end of a commercially available diode (the PTW 60016 electron diode). The output factors subsequently measured with the new diode design were compared to current benchmark small field output factor measurements. Methods A water-tight ‘cap’ was constructed so that it could be placed over the upstream end of the diode. The cap was able to be offset from the end of the diode, thus creating an air gap. The air gap width was the same as the diode width (7 mm) and the thickness of the air gap could be varied. Output factor measurements were made using square field sizes of side length from 5 to 50 mm, using a 6 MV photon beam. The set of output factor measurements were repeated with the air gap thickness set to 0, 0.5, 1.0 and 1.5 mm. The optimal air gap thickness was found in a similar manner to that proposed by Charles et al. [2]. An IBA stereotactic field diode, corrected using Monte Carlo calculated kq,clin,kq,msr values [3] was used as the gold standard. Results The optimal air thickness required for the PTW 60016 electron diode was 1.0 mm. This was close to the Monte Carlo predicted value of 1.15 mm2. The sensitivity of the new diode design was independent of field size (kq,clin,kq,msr = 1.000 at all field sizes) to within 1 %. Discussion and conclusions The work of Charles et al. [2] has been proven experimentally. An existing commercial diode has been converted into a correction-less small field diode by the simple addition of an ‘air cap’. The method of applying a cap to create the new diode leads to the diode being dual purpose, as without the cap it is still an unmodified electron diode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Given the known challenges of obtaining accurate measurements of small radiation fields, and the increasing use of small field segments in IMRT beams, this study examined the possible effects of referencing inaccurate field output factors in the planning of IMRT treatments. Methods This study used the Brainlab iPlan treatment planning system to devise IMRT treatment plans for delivery using the Brainlab m3 microMLC (Brainlab, Feldkirchen, Germany). Four pairs of sample IMRT treatments were planned using volumes, beams and prescriptions that were based on a set of test plans described in AAPM TG 119’s recommendations for the commissioning of IMRT treatment planning systems [1]: • C1, a set of three 4 cm volumes with different prescription doses, was modified to reduce the size of the PTV to 2 cm across and to include an OAR dose constraint for one of the other volumes. • C2, a prostate treatment, was planned as described by the TG 119 report [1]. • C3, a head-and-neck treatment with a PTV larger than 10 cm across, was excluded from the study. • C4, an 8 cm long C-shaped PTV surrounding a cylindrical OAR, was planned as described in the TG 119 report [1] and then replanned with the length of the PTV reduced to 4 cm. Both plans in each pair used the same beam angles, collimator angles, dose reference points, prescriptions and constraints. However, one of each pair of plans had its beam modulation optimisation and dose calculation completed with reference to existing iPlan beam data and the other had its beam modulation optimisation and dose calculation completed with reference to revised beam data. The beam data revisions consisted of increasing the field output factor for a 0.6 9 0.6 cm2 field by 17 % and increasing the field output factor for a 1.2 9 1.2 cm2 field by 3 %. Results The use of different beam data resulted in different optimisation results with different microMLC apertures and segment weightings between the two plans for each treatment, which led to large differences (up to 30 % with an average of 5 %) between reference point doses in each pair of plans. These point dose differences are more indicative of the modulation of the plans than of any clinically relevant changes to the overall PTV or OAR doses. By contrast, the maximum, minimum and mean doses to the PTVs and OARs were smaller (less than 1 %, for all beams in three out of four pairs of treatment plans) but are more clinically important. Of the four test cases, only the shortened (4 cm) version of TG 119’s C4 plan showed substantial differences between the overall doses calculated in the volumes of interest using the different sets of beam data and thereby suggested that treatment doses could be affected by changes to small field output factors. An analysis of the complexity of this pair of plans, using Crowe et al.’s TADA code [2], indicated that iPlan’s optimiser had produced IMRT segments comprised of larger numbers of small microMLC leaf separations than in the other three test cases. Conclusion: The use of altered small field output factors can result in substantially altered doses when large numbers of small leaf apertures are used to modulate the beams, even when treating relatively large volumes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When radiation therapy centres are equipped with two or more linear accelerators from the same vendor, they are usually beam-matched. This work tested the sensitivity of optically stimulated luminescence dosimeters (OSLDs) across matched linear accelerators. The responses were compared with an unshielded diode detector for varying field sizes. Clinical studies are currently done with thermoluminescent dosimeters (TLD), which absorb radiation then emit some levels of light determined by the radiation absorption when heated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the effect of very small air gaps (less than 1 mm) on the dosimetry of small photon fields used for stereotactic treatments. Measurements were performed with optically stimulated luminescent dosimeters (OSLDs) for 6 MV photons on a Varian 21iX linear accelerator with a Brainlab lMLC attachment for square field sizes down to 6 mm 9 6 mm. Monte Carlo simulations were performed using EGSnrc C++ user code cavity. It was found that the Monte Carlo model used in this study accurately simulated the OSLD measurements on the linear accelerator. For the 6 mm field size, the 0.5 mm air gap upstream to the active area of the OSLD caused a 5.3 % dose reduction relative to a Monte Carlo simulation with no air gap...