606 resultados para solid boundary treatment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atherosclerotic plaque rupture has been extensively considered as the leading cause of death in western countries. It is believed that high stresses within plaque can be an important factor on triggering the rupture of the plaque. Stress analysis in the coronary and carotid arteries with plaque have been developed by many researchers from 2D to 3-D models, from structure analysis only to the Fluid-Structure Interaction (FSI) models[1].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acceptance of broadband ultrasound attenuation (BUA) for the assessment of osteoporosis suffers from a limited understanding of both ultrasound wave propagation through cancellous bone and its exact dependence upon the material and structural properties. It has recently been proposed that ultrasound wave propagation in cancellous bone may be described by a concept of parallel sonic rays; the transit time of each ray defined by the proportion of bone and marrow propagated. A Transit Time Spectrum (TTS) describes the proportion of sonic rays having a particular transit time, effectively describing the lateral inhomogeneity of transit times over the surface aperture of the receive ultrasound transducer. The aim of this study was to test the hypothesis that the solid volume fraction (SVF) of simplified bone:marrow replica models may be reliably estimated from the corresponding ultrasound transit time spectrum. Transit time spectra were derived via digital deconvolution of the experimentally measured input and output ultrasonic signals, and compared to predicted TTS based on the parallel sonic ray concept, demonstrating agreement in both position and amplitude of spectral peaks. Solid volume fraction was calculated from the TTS; agreement between true (geometric calculation) with predicted (computer simulation) and experimentally-derived values were R2=99.9% and R2=97.3% respectively. It is therefore envisaged that ultrasound transit time spectroscopy (UTTS) offers the potential to reliably estimate bone mineral density and hence the established T-score parameter for clinical osteoporosis assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ordinal qualitative data are often collected for phenotypical measurements in plant pathology and other biological sciences. Statistical methods, such as t tests or analysis of variance, are usually used to analyze ordinal data when comparing two groups or multiple groups. However, the underlying assumptions such as normality and homogeneous variances are often violated for qualitative data. To this end, we investigated an alternative methodology, rank regression, for analyzing the ordinal data. The rank-based methods are essentially based on pairwise comparisons and, therefore, can deal with qualitative data naturally. They require neither normality assumption nor data transformation. Apart from robustness against outliers and high efficiency, the rank regression can also incorporate covariate effects in the same way as the ordinary regression. By reanalyzing a data set from a wheat Fusarium crown rot study, we illustrated the use of the rank regression methodology and demonstrated that the rank regression models appear to be more appropriate and sensible for analyzing nonnormal data and data with outliers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In treatment comparison experiments, the treatment responses are often correlated with some concomitant variables which can be measured before or at the beginning of the experiments. In this article, we propose schemes for the assignment of experimental units that may greatly improve the efficiency of the comparison in such situations. The proposed schemes are based on general ranked set sampling. The relative efficiency and cost-effectiveness of the proposed schemes are studied and compared. It is found that some proposed schemes are always more efficient than the traditional simple random assignment scheme when the total cost is the same. Numerical studies show promising results using the proposed schemes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficacy, adverse reactions, and long-term effects of intestinal lavage treatment with a balanced electrolyte solution (Golytely) was evaluated in patients with cystic fibrosis and distal intestinal obstruction syndrome. Twenty-two patients with cystic fibrosis (mean age 21.8 years, range 14 to 34 years, 15 boys or men) who sough medical attention because of abdominal pain and a mass in the right iliac fossa received Golytely, 5.6 ± 1.9 L (mean ± 1 SD), either orally (n = 14) or via nasogastric tube (n = 8) during 5.6 ± 2.4 hours. No serious side effects occurred. Serum electrolyte values remained within normal limits. Body weight did not change significantly. Minor adverse reactions included bloating (n = 12), nausea (n = 8), vomiting (n = 1), and chills (n = 3). All but one patient reported impressive relief of symptoms and remained pain free for an average of 3 months (range 1 to 19 months). Symptoms of abdominal pain and radiologic signs of fecal impaction assessed before and after lavage both decreased significantly (P < .0001). During follow-up (mean 15.2 months, range 4 to 26 months), 11 patients required a total of 38 (range one to nine) additional doses of Golytely. Seven patients drank the solution at home (21 treatments); only two patients chose a nasogastric tube. In ten patients with symptoms of recurrent distal intestinal obstruction syndrome prior to institution of therapy, duration of hospitalization was significantly reduced by this treatment (5.1 ± 7.6 v 2.3 ± 6.3 hospital days per annum, P < .02). It is concluded that intestinal lavage is a well-accepted, safe, and effective therapy for distal intestinal obstruction syndrome in patients with cystic fibrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to help broaden the use of electronic portal imaging devices (EPIDs) for pre-treatment patient positioning verification, from photon-beam radiotherapy to photon- and electron-beam radiotherapy, by proposing and testing a method for acquiring clinicallyuseful EPID images of patient anatomy using electron beams, with a view to enabling and encouraging further research in this area. EPID images used in this study were acquired using all available beams from a linac configured to deliver electron beams with nominal energies of 6, 9, 12, 16 and 20 MeV, as well as photon beams with nominal energies of 6 and 10 MV. A widely-available heterogeneous, approximately-humanoid, thorax phantom was used, to provide an indication of the contrast and noise produced when imaging different types of tissue with comparatively realistic thicknesses. The acquired images were automatically calibrated, corrected for the effects of variations in the sensitivity of individual photodiodes, using a flood field image. For electron beam imaging, flood field EPID calibration images were acquired with and without the placement of blocks of water-equivalent plastic (with thicknesses approximately equal to the practical range of electrons in the plastic) placed upstream of the EPID, to filter out the primary electron beam, leaving only the bremsstrahlung photon signal. While the electron beam images acquired using a standard (unfiltered) flood field calibration were observed to be noisy and difficult to interpret, the electron beam images acquired using the filtered flood field calibration showed tissues and bony anatomy with levels of contrast and noise that were similar to the contrast and noise levels seen in the clinically acceptable photon beam EPID images. The best electron beam imaging results (highest contrast, signal-to-noise and contrast-to-noise ratios) were achieved when the images were acquired using the higher energy electron beams (16 and 20 MeV) when the EPID was calibrated using an intermediate (12 MeV) electron beam energy. These results demonstrate the feasibility of acquiring clinically-useful EPID images of patient anatomy using electron beams and suggest important avenues for future investigation, thus enabling and encouraging further research in this area. There is manifest potential for the EPID imaging method proposed in this work to lead to the clinical use of electron beam imaging for geometric verification of electron treatments in the future.