601 resultados para field testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In December 1986 funds were approved to double the intensity of random breath testing (RBT) and provide publicity support for police efforts. These changes were considered necessary to make RBT effective. RBT methods were changed in the metropolitan area to enable block testing (pulling over a block of traffic rather than one or two cars), deployment of police to cut off escape routes, and testing by traffic patrols in all police subdivisions. Additional operators were trained for country RBT. A publicity campaign was developed, aimed mainly at male drivers aged 18-50. The campaign consisted of the cardsharp television commercials, radio commercials, newspaper articles, posters and pamphlets. Increased testing and the publicity campaigns were launched on 10 April 1987. Police tests increased by 92.5% in May December 1987, compared with the same period in the previous four years. The detection rate for drinking drivers picked up by police who were cutting off escape routes was comparatively high, indicating that drivers were attempting to avoid RBT, and that this police method was effective at detecting these drivers. A telephone survey indicated that drivers were aware of the messages of the publicity campaign. The telephone survey also indicated that the target group had been exposed to high levels of RBT, as planned, and that fear of apprehension was the major factor deterring them from drink driving. A roadside survey of driver blood alcohol concentrations (BACs) by the University of Adelaides Road Accident Research Unit (RARU) showed that, between 10p.m. and 3a.m., the proportion of drivers in Adelaide with a BAC greater than or equal to 0/08 decreased by 42%. Drivers under 21 were identified as a possible problem area. Fatalities in the twelve month period commencing May 1987 decreased by 18% in comparison with the previous twelve month period, and by 13% in comparison with the average of the previous two twelve month periods (commencing May 1985 and May 1986). There are indications that this trend is continuing. It is concluded that the increase in RBT, plus publicity, was successful in achieving its aims of reductions in drink driving and accidents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Random breath testing (RBT) was introduced in South Australia in 1981 with the intention of reducing the incidence of accidents involving alcohol. In April 1985, a Select Committee of the Upper House which had been established to review the operation of random breath testing in this State and any other associated matters and report accordingly presented its report. After consideration of this report, the Government introduced extensive amendments to those sections of the Motor Vehicles Act (MVA) and Road Traffic Act (RTA) which deal with RBT and drink driving penalties. The amended section 47da of the RTA requires that: (5) The Minister shall cause a report to be prepared within three months after the end of each calendar year on the operation and effectiveness of this section and related sections during that calendar year. (6) The Minister shall, within 12 sitting days after receipt of a report under subsection (5), cause copies of the report to be laid before each House of Parliament. This is the first such report. Whilst it deals with RBT over a full year, the changed procedures and improved flexibility allowed by the revision to the RTA were only introduced late in 1985 and then only to the extent that the existing resources would allow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Aim There is a 70% higher age-adjusted incidence of heart failure (HF) amongst Aboriginal and Torres Strait Islander people, three times more hospitalisations and twice as many deaths than non-Aboriginal people. There is a need to develop holistic yet individualised approaches in accord with the values of Aboriginal community healthcare to support patient education and self-care. The aim of this study was to re-design an existing HF educational resource (Fluid Watchers-Pacific Rim) to be culturally safe for Aboriginal and Torres Strait Islander peoples, working in collaboration with the local community, and to conduct feasibility testing. Methods This study was conducted in two phases and utilised a mixed methods approach (qualitative and quantitative). Phase 1 of this study used action research methods to develop a culturally safe electronic resource to be provided to Aboriginal HF patients via a tablet computer. A HF expert panel adapted the existing resource to ensure it was evidence-based and contained appropriate language and images that reflects Aboriginal culture. A stakeholder group (which included Aboriginal workers and HF patients, as well as researchers and clinicians) then reviewed the resources and changes were made accordingly. In Phase 2, the new resource was tested on a sample of Aboriginal HF patients to assess feasibility and acceptability. Patient knowledge, satisfaction and self-care behaviours were measured using a before and after design with validated questionnaires. As this was a pilot test to determine feasibility, no statistical comparisons were made. Results - Phase 1: Throughout the process of resource development, two main themes emerged from the stakeholder consultation. These were the importance of identity, meaning that it was important to ensure that the resource accurately reflected the local community, with the appropriate clothing, skin tone and voice. The resource was adapted to reflect this and of the local community voiced the recordings for the resource. The other theme was comprehension; images were important and all text was converted to the first person and used plain language. - Phase 2: Five Aboriginal participants, mean age 61.6 10.0 years, with NYHA Class III and IV heart failure were enrolled. Participants reported a high level of satisfaction with the resource (83.0%). HF knowledge (percentage of correct responses) increased from 48.0 6.7% to 58.0 9.7%, a 20.8% increase and results of the self-care index indicated that the biggest change was in patient confidence for self-care with a 95% increase in confidence score (46.7 16.0 to 91.1 11.5). Changes in management and maintenance scores varied between9275 patients. Conclusion By working in collaboration with HF experts, Aboriginal researchers and patients, a culturally safe HF resource has been developed for Aboriginal and Torres Strait Islander patients. Engaging Aboriginal researchers, capacity-building, and being responsive to local systems and structures enabled this pilot study to be successfully completed with the Aboriginal community and positive participant feedback demonstrated that the methodology used in this study was appropriate and acceptable; participants were able to engage with willingness and confidence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crime analysts have traditionally received little guidance from academic researchers in key tasks in the analysis process, specifically the testing of multiple hypotheses and evaluating evidence in a scientific fashion. This article attempts to fill this gap by outlining a method (the Analysis of Competing Hypotheses) of systematically analysing multiple explanations for crime problems. The method is systematic, avoids many cognitive errors common in analysis, and is explicit. It is argued that the implementation of this approach makes analytic products audit-able, the reasoning underpinning them transparent, and provides intelligence managers a rational professional development tool for individual analysts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All sound research commence with the selection of a research paradigm. The chosen research paradigm is significant in shaping the researchers perspectives of the world and it is a vital step in any studys research design. There are different paradigms that IS researchers can choose from; amongst which the interpretive paradigm is growing in acceptance.. Though interpretive research has emerged as an important strand in Information Systems (IS), guidelines on how to conduct interpretive research and how to evaluate them have been scarce. Klein and Myers presented seven principles with examples for each from three case examples. While these principles are much valued, there is a lack of support for novice researchers on how to embed these principles in an overall research design, which could help with the aid of a detailed example that has done so. Thus, this paper aims to address this gap, and presents how Klein and Myerss principles were applied within an example study that investigated shared services in the Malaysian Higher Education context. The example study adopted the interpretive paradigm as the most suited approach that fitted their research questions and goals. More details about the selection and adoption of the Klein and Myerss guidelines in the context of the shared services research case study are presented in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using electric-field-induced optical second-harmonic generation (EFISHG) measurement, we analyzed hysteresis behavior of capacitance-voltage (C-V) characteristics of IZO/polyterpenol (PT)/C/pentacene/Au diodes, where PT layer is actively working as a hole-transport electron-blocking layer. The EFISHG measurement verified the presence of interface accumulated charges in the diodes, and showed that a space charge electric field from accumulated excess electrons (holes) that remain at the PT/C (C/pentacene) interface is responsible for the hysteresis loop observed in the C-V characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time-resolved electric field induced second harmonic generation technique was used to probe the carrier transients within double-layer pentacene-based MIM devices. Polyterpenol thin films fabricated from non-synthetic environmentally sustainable source were used as a blocking layer to assist in visualisation of single-species carrier transportation during charging and discharging under different bias conditions. Results demonstrated that carrier transients were comprised of charging on electrodes, followed by carrier injection and charging of the interface. Polyterpenol was demonstrated to be a sound blocking material and can therefore be effectively used for probing of double-layer devices using EFISHG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A non-synthetic polymer material, polyterpenol, was fabricated using a dry polymerization process namely RF plasma polymerization from an environmentally friendly monomer and its surface, optical and electrical properties investigated. Polyterpenol films were found to be transparent over the visible wavelength range, with a smooth surface with an average roughness of less than 0.4 nm and hardness of 0.4 GPa. The dielectric constant of 3.4 for polyterpenol was higher than that of the conventional polymer materials used in the organic electronic devices. The non-synthetic polymer material was then implemented as a surface modification of the gate insulator in field effect transistor (OFET) and the properties of the device were examined. In comparison to the similar device without the polymer insulating layer, the polyterpenol based OFET device showed significant improvements. The addition of the polyterpenol interlayer in the OFET shifted the threshold voltage significantly; + 20 V to -3 V. The presence of trapped charge was not observed in the polyterpenol interlayer. This assisted in the improvement of effective mobility from 0.012 to 0.021 cm 2/Vs. The switching property of the polyterpenol based OFET was also improved; 107 compared to 104. The results showed that the non-synthetic polyterpenol polymer film is a promising candidate of insulators in electronic devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After more than twenty years of basic and applied research, the use of nanotechnology in the design and manufacture of nanoscale materials is rapidly increasing, particularly in commercial applications that span from electronics across renewable energy areas, and biomedical devices. Novel polymers are attracting significant attention for they promise to provide a lowcost highperformance alternative to existing materials. Furthermore, these polymers have the potential to overcome limitations imposed by currently available materials thus enabling the development of new technologies and applications that are currently beyond our reach. This work focuses on the development of a range of new lowcost environmentallyfriendly polymer materials for applications in areas of organic (flexible) electronics, optics, and biomaterials. The choice of the monomer reflects the environmentallyconscious focus of this project. Terpinen4ol is a major constituent of Australian grown Melaleuca alternifolia (tea tree) oil, attributed with the oil's antimicrobial and antiinflammatory properties. Plasma polymerisation was chosen as a deposition technique for it requires minimal use of harmful chemicals and produces no hazardous byproducts. Polymer thin films were fabricated under varied process conditions to attain materials with distinct physicochemical, optoelectrical, biological and degradation characteristics. The resultant materials, named polyterpenol, were extensively characterised using a number of wellaccepted and novel techniques, and their fundamental properties were defined. Polyterpenol films were demonstrated to be hydrocarbon rich, with variable content of oxygen moieties, primarily in the form of hydroxyl and carboxyl functionalities. The level of preservation of original monomer functionality was shown to be strongly dependent on the deposition energy, with higher applied power increasing the molecular fragmentation and substrate temperature. Polyterpenol water contact angle contact angle increased from 62.7 for the 10 W samples to 76.3 for the films deposited at 100 W. Polymers were determined to resist solubilisation by water, due to the extensive intermolecular and intramolecular hydrogen bonds present, and other solvents commonly employed in electronics and biomedical processing. Independent of deposition power, the surface topography of the polymers was shown to be smooth (Rq <0.5 nm), uniform and defect free. Hardness of polyterpenol coatings increased from 0.33 GPa for 10 W to 0.51 GPa for 100 W (at 500 N load). Coatings deposited at higher input RF powers showed less mechanical deformation during nanoscratch testing, with no considerable damage, cracking or delamination observed. Independent of the substrate, the quality of film adhesion improved with RF power, suggesting these coatings are likely to be more stable and less susceptible to wear. Independent of fabrication conditions, polyterpenol thin films were optically transparent, with refractive index approximating that of glass. Refractive index increased slightly with deposition power, from 1.54 (10 W) to 1.56 (100 W) at 500 nm. The optical band gap values declined with increasing power, from 2.95 eV to 2.64 eV, placing the material within the range for semiconductors. Introduction of iodine impurity reduced the band gap of polyterpenol, from 2.8 eV to 1.64 eV, by extending the density of states more into the visible region of the electromagnetic spectrum. Doping decreased the transparency and increased the refractive index from 1.54 to 1.70 (at 500 nm). At optical frequencies, the real part of permittivity (k) was determined to be between 2.34 and 2.65, indicating a potential low-k material. These permittivity values were confirmed at microwave frequencies, where permittivity increased with input RF energy from 2.32 to 2.53 (at 10 GHz ) and from 2.65 to 2.83 (at 20 GHz). At low frequencies, the dielectric constant was determined from currentvoltage characteristics of AlpolyterpenolAl devices. At frequencies below 100 kHz, the dielectric constant varied with RF power, from 3.86 to 4.42 at 1 kHz. For all samples, the resistivity was in order of 1010 _m (at 6 V), confirming the insulating nature of polyterpenol material. In situ iodine doping was demonstrated to increase the conductivity of polyterpenol, from 5.05 10 S/cm to 1.20 10 S/cm (at 20 V). Exposed to ambient conditions over extended period of time, polyterpenol thin films were demonstrated to be optically, physically and chemically stable. The bulk of ageing occurred within first 150 h after deposition and was attributed to oxidation and volumetric relaxation. Thermal ageing studies indicated thermal stability increased for the films manufactured at higher RF powers, with degradation onset temperature associated with weight loss shifting from 150 C to 205 C for 10 W and 100 W polyterpenol, respectively. Annealing the films to 405 C resulted in full dissociation of the polymer, with minimal residue. Given the outcomes of the fundamental characterisation, a number of potential applications for polyterpenol have been identified. Flexibility, tunable permittivity and loss tangent properties of polyterpenol suggest the material can be used as an insulating layer in plastic electronics. Implementation of polyterpenol as a surface modification of the gate insulator in pentacene-based Field Effect Transistor resulted in significant improvements, shifting the threshold voltage from + 20 V to 3 V, enhancing the effective mobility from 0.012 to 0.021 cm/Vs, and improving the switching property of the device from 10 to 10. Polyterpenol was demonstrated to have a hole transport electron blocking property, with potential applications in many organic devices, such as organic light emitting diodes. Encapsulation of biomedical devices is also proposed, given that under favourable conditions, the original chemical and biological functionality of terpinen4ol molecule can be preserved. Films deposited at low RF power were shown to successfully prevent adhesion and retention of several important human pathogens, including P. aeruginosa, S. aureus, and S. epidermidis, whereas films deposited at higher RF power promoted bacterial cell adhesion and biofilm formation. Preliminary investigations into in vitro biocompatibility of polyterpenol demonstrated the coating to be nontoxic for several types of eukaryotic cells, including Balb/c mice macrophage and human monocyte type (HTP1 non-adherent) cells. Applied to magnesium substrates, polyterpenol encapsulating layer significantly slowed down in vitro biodegradation of the metal, thus increasing the viability and growth of HTP1 cells. Recently, applied to varied nanostructured titanium surfaces, polyterpenol thin films successfully reduced attachment, growth, and viability of P. aeruginosa and S. aureus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Fatigue is one of the most distressing and commonly experienced symptoms in patients with advanced cancer. Although the self-management (SM) of cancer-related symptoms has received increasing attention, no research instrument assessing fatigue SM outcomes for patients with advanced cancer is available. Objectives: to describe the development and preliminary testing of an interviewer administered instrument for assessing the frequency, and perceived levels of effectiveness and self-efficacy associated with fatigue SM behaviors in patients with advanced cancer. Methods: The development and testing of the Self-efficacy in Managing Symptoms Scale- Fatigue Subscale for Patients with Advanced Cancer (SMSFS-A) involved a number of procedures: item-generation using a comprehensive literature review and semi-structured interviews, content validity evaluation using expert panel reviews, and face validity and test-retest reliability evaluation using pilot testing. Results: Initially, 23 items (22 specific behaviors with one global item) were generated from the literature review and semi-structured interviews. After two rounds of expert panel review, the final scale was reduced to 17 items (16 behaviors with one global item). Participants in the pilot test (n=10) confirmed that the questions in this scale were clear and easy to understand. Bland-Altman analysis showed agreement of results over a one-week interval. Conclusions: The SMSFS-A items were generated using multiple sources. This tool demonstrated preliminary validity and reliability. Implications for practice: The SMSFS-A has the potential to be used for clinical and research purposes. Nurses can use this instrument for collecting data to inform the initiation of appropriate fatigue SM support for this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this report, we describe a simple correction for multiple testing of single-nucleotide polymorphisms (SNPs) in linkage disequilibrium (LD) with each other, on the basis of the spectral decomposition (SpD) of matrices of pairwise LD between SNPs. This method provides a useful alternative to more computationally intensive permutation tests. Additionally, output from SNPSpD includes eigenvalues, principal-component coefficients, and factor "loadings" after varimax rotation, enabling the selection of a subset of SNPs that optimize the information in a genomic region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To explore the effect of small-aperture optics, designed to aid presbyopes by increasing ocular depth-of-focus, on measurements of the visual field. Methods Simple theoretical and ray-tracing models were used to predict the impact of different designs of small-aperture contact lenses or corneal inlays on the proportion of light passing through natural pupils of various diameters as a function of the direction in the visual field. The left eyes of five healthy volunteers were tested using three afocal, hand-painted opaque soft contact lenses (www.davidthomas.com). Two were opaque over a 10 mm diameter but had central clear circular apertures of 1.5 and 3.0 mm in diameter. The third had an annular opaque zone with inner and outer diameters of 1.5 and 4.0 mm, approximately simulating the geometry of the KAMRA inlay (www.acufocus.com). A fourth, clear lens was used for comparison purposes. Visual fields along the horizontal meridian were evaluated up to 50 eccentricity with static automated perimetry (Medmont M700, stimulus Goldmann-size III; www.medmont.com). Results According to ray-tracing, the two lenses with the circular apertures were expected to reduce the relative transmittance of the pupil to zero at specific field angles (around 60 for the conditions of the experimental measurements). In contrast, the annular stop had no effect on the absolute field but relative transmittance was reduced over the central area of the field, the exact effects depending upon the natural pupil diameter. Experimental results broadly agreed with these theoretical expectations. With the 1.5 and 3.0 mm pupils, only minor losses in sensitivity (around 2 dB) in comparison with the clear-lens case occurred across the central 10 radius of field. Beyond this angle, sensitivity losses increased, to reach about 7 dB at the edge of the measured field (50). The field results with the annular stop showed at most only a slight loss in sensitivity (3 dB) across the measured field. Conclusion The present theoretical and experimental results support earlier clinical findings that KAMRA-type annular stops, unlike circular artificial pupils, have only minor effects on measurements of the visual field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic. Each of the methods previously used in the literature were assessed for their effect on the bending of the sample and concordant stiffness. The choice of outcome measures used in in vitro fracture studies was also assessed. Mechanical testing was conducted on seven hole locked plated constructs in each method for comparison. Based on the assessment of each method the use of spherical bearings, ball joints or similar is suggested at both ends of the sample. The use of near and far cortex movement was found to be more comprehensive and more accurate than traditional centrally calculated inter fragmentary movement values; stiffness was found to be highly susceptible to the accuracy of deformation measurements and constraint method, and should only be used as a within study comparison method. The reported stiffness values of locked plate constructs from in vitro mechanical testing is highly susceptible to testing constraints and output measures, with many standard techniques overestimating the stiffness of the construct. This raises the need for further investigation into the actual mechanical behaviour within the fracture gap of these devices.