468 resultados para energy gain
Resumo:
This chapter describes the use of collaborative learning as an approach to enhance English language learning by students from non-English speaking backgrounds. Communicative Language Teaching (CLT) principles were applied to two case studies, one comprising of undergraduate English as Foreign Language Learners in Turkey and the other involved English as Second Language learners in Australia. Social constructivism inspired communicative language teaching using collaborative learning activities such as team work, interactive peer-based learning, and iterative stages of learning matrix were incorporated to enhance students' learning outcomes. Data collected after the CLT intervention was made up of field notes, reflective logs and focus group interviews which revealed complementarities, as well as subtle differences between the two cases. The findings were summarized as learning dispositions; speaking fluency and confidence; learning diagnostics and completion deficiencies; task engagement, flow theory and higher order thinking skills; in addition to self efficacy and development of student identity. CLT has the potential to provide a more inclusive and dynamic education for diverse learners through vital outcomes and benefits which resonate with the real world.
Resumo:
This thesis is a documented energy audit and long term study of energy and water reduction in a ghee factory. Global production of ghee exceeds 4 million tonnes annually. The factory in this study refines dairy products by non-traditional centrifugal separation and produces 99.9% pure, canned, crystallised Anhydrous Milk Fat (Ghee). Ghee is traditionally made by batch processing methods. The traditional method is less efficient, than centrifugal separation. An in depth systematic investigation was conducted of each item of major equipment including; ammonia refrigeration, a steam boiler, canning equipment, pumps, heat exchangers and compressed air were all fine-tuned. Continuous monitoring of electrical usage showed that not every initiative worked, others had pay back periods of less than a year. In 1994-95 energy consumption was 6,582GJ and in 2003-04 it was 5,552GJ down 16% for a similar output. A significant reduction in water usage was achieved by reducing the airflow in the refrigeration evaporative condensers to match the refrigeration load. Water usage has fallen 68% from18ML in 1994-95 to 5.78ML in 2003-04. The methods reported in this thesis could be applied to other industries, which have similar equipment, and other ghee manufacturers.
Resumo:
Damage localization induced by strain softening can be predicted by the direct minimization of a global energy function. This article concerns the computational strategy for implementing this principle for softening materials such as concrete. Instead of using heuristic global optimization techniques, our strategies are a hybrid of local optimization methods with a path-finding approach to ensure a global optimum. With admissible nodal displacements being independent variables, it is easy to deal with the geometric (mesh) constraint conditions. The direct search optimization methods recover the localized solutions for a range of softening lattice models which are representative of quasi-brittle structures
Resumo:
Over the last few years more stringent environmental laws (e.g. the German “Energie¬ein-sparverordnung ENEV” - Energy Performance of Buildings Directive) and soaring energy prices has increased the need for the real estate industry to react and participate in overall energy reduction through efficient house construction and design, as well as upgrading the existing housing stock to be more energy efficient. Therefore the Property Economics Group at Queensland University of Technology in Australia and Nuertingen-Geislingen University in Germany are carrying out research in relation to sustainable housing construction and public awareness of “green” residential property. Part of this research is to gain an understanding of the level of knowledge and importance of these issues to the house buyer and to determine the importance of sustainable housing to the general public. The paper compares data from two different empirical studies; one of studies analyzes the situation in New Zealand, the other is focused on Germany.
Resumo:
The Body Mass Index (BMI) has been used worldwide as an indicator of fatness. However, the universal cut-off points by the World Health Organisation (WHO) classification may not be appropriate for every ethnic group when consider the relationship with their actual total body fatness(%BF). The application of population-specific classifications to assess BMI may be more relevant to public health. Ethnic differences in the BMI%BF relationship between 45 Japanese and 42 Australian-Caucasian males were assessed using whole body dual-energy X-ray absorptiometry (DXA) scan and anthropometry using a standard protocol. Japanese males had significantly (p<0.05) greater %BF at given BMI values than Australian males. When this is taken into account the newly proposed Asia-Pacific BMI classification of BMI 23 as overweight and 25 as obese may better assess the level of obesity that is associated increased health risks for this population. To clarify the current findings, further studies that compare the relationships across other Japanese populations are recommended.
Resumo:
Energy efficient lubricants are becoming increasingly popular. This is due to a global increase in environmental awareness combined with the potential of reducing operating costs. A new test method of evaluating the energy efficiency of gear oils has been described in this report. The method involves measuring the power required by an FZG test rig to run while using a particular test lubricant. For each oil that was being evaluated, the rig was run for 10 minutes at a load stage of 10. Six extreme pressure (EP) industrial gear oils of mineral base were tested. The difference in power requirements between the best and the worst performing oils was 2.77 and 3.24 kW, respectively. This equates to a 14.6% reduction in power, a significant amount if considered in relation to a high powered industrial machine. The oils of superior performance were noticed to run at reduced temperatures. They were also more expensive than the other products of lesser performance.
Resumo:
In this paper, a fixed-switching-frequency closed-loop modulation of a voltage-source inverter (VSI), upon the digital implementation of the modulation process, is analyzed and characterized. The sampling frequency of the digital processor is considered as an integer multiple of the modulation switching frequency. An expression for the determination of the modulation design parameter is developed for smooth modulation at a fixed switching frequency. The variation of the sampling frequency, switching frequency, and modulation index has been analyzed for the determination of the switching condition under closed loop. It is shown that the switching condition determined based on the continuous-time analysis of the closed-loop modulation will ensure smooth modulation upon the digital implementation of the modulation process. However, the stability properties need to be tested prior to digital implementation as they get deteriorated at smaller sampling frequencies. The closed-loop modulation index needs to be considered maximum while determining the design parameters for smooth modulation. In particular, a detailed analysis has been carried out by varying the control gain in the sliding-mode control of a two-level VSI. The proposed analysis of the closed-loop modulation of the VSI has been verified for the operation of a distribution static compensator. The theoretical results are validated experimentally on both single- and three-phase systems.
Resumo:
In photovoltaic, fuel cells and storage batteries, the low output DC voltage should be boosted. Therefore, a step-up converter is necessary to boost the low DC voltage for the DC link voltage of the inverter. The main contribution of this chapter is to electrical energy conversion in renewable energy systems based on multilevel inverters. Different configuration of renewable energy systems based on power converters will be discussed in detail. Finally, a new single inductor Multi-Output Boost (MOB) converter is proposed, which is compatible with the diode-clamped configuration. Steady state and dynamic analyses have been carried out in order to show the validity of the proposed topology. Then the joint circuit of the proposed DC-DC converter with a three-level diode-clamped converter is presented in order to have a series regulated voltage at the DC link voltage of the diode-clamped inverter. MOB converter can boost the low input DC voltage of the renewable energy sources and at the same time adjust the voltage across each capacitor to the desired voltage levels, thereby solving the main problem associated with capacitor voltage imbalance in this type of multilevel converter.
Resumo:
This paper proposes new droop control methods for load sharing in a rural area with distributed generation. Highly resistive lines, typical of rural low voltage networks, always create a big challenge for conventional droop control. To overcome the conflict between higher feedback gain for better power sharing and system stability in angle droop, two control methods have been proposed. The first method considers no communication among the distributed generators (DGs) and regulates the converter output voltage and angle ensuring proper sharing of load in a system having strong coupling between real and reactive power due to high line resistance. The second method, based on a smattering of communication, modifies the reference output volt-age angle of the DGs depending on the active and reactive power flow in the lines connected to point of common coupling (PCC). It is shown that with the second proposed control method, an economical and minimum communication system can achieve significant improvement in load sharing. The difference in error margin between proposed control schemes and a more costly high bandwidth communication system is small and the later may not be justified considering the increase in cost. The proposed control shows stable operation of the system for a range of operating conditions while ensuring satisfactory load sharing.