49 resultados para cosmetic procedures
Resumo:
Introduction & aims The demand for evidence of efficacy of treatments in general and orthopaedic surgical procedures in particular is ever increasing in Australia and worldwide. The aim of this study is to share the key elements of an evaluation framework recently implemented in Australia to determine the efficacy of bone-anchored prostheses. Method The proposed evaluation framework to determine the benefit and harms of bone-anchored prostheses for individuals with limb loss was extracted from a systematic review of the literature including seminal studies focusing on clinical benefits and safety of procedures involving screw-type implant (e.g., OPRA) and press-fit fixations (e.g., EEFT, ILP, OPL). [1-64] Results The literature review highlighted that a standard and replicable evaluation framework should focus on: • The clinical benefits with a systematic recording of health-related quality of life (e.g., SF-26, Q-TFA), mobility predictor (e.g., AMPRO), ambulation abilities (e.g., TUG, 6MWT), walking abilities (e.g., characteristic spatio-temporal) and actual activity level at baseline and follow-up post Stage 2 surgery, • The potential harms with systematic recording of residuum care, infection, implant stability, implant integrity, injuries (e.g., falls) after Stage 1 surgery. There was a general consensus around the instruments to monitor most of the benefits and harms. The benefits could be assessed using a wide spectrum of complementary assessments ranging from subjective patient self-reporting to objective measurements of physical activity. However, this latter was assessed using a broad range of measurements (e.g., pedometer, load cell, energy consumption). More importantly, the lack of consistent grading of infections was sufficiently noticeable to impede cross-fixation comparisons. Clearly, a more universal grading system is needed. Conclusions Investigators are encouraged to implement an evaluation framework featuring the domains and instruments proposed above using a single database to facilitate robust prospective studies about potential benefits and harms of their procedure. This work is also a milestone in the development of national and international clinical outcome registries.
Resumo:
Sustainable urban development, a major issue at global scale, will become more relevant according to population growth predictions in developed and developing countries. Societal and international recognition of sustainability concerns led to the development of specific tools and procedures, known as sustainability assessments/appraisals (SA). Their effectiveness however, considering that global quality life indicators have worsened since their introduction, has promoted a re-thinking of SA instruments. More precisely, Strategic Environmental Assessment (SEA), – a tool introduced in the European context to evaluate policies, plans, and programmes (PPPs), – is being reconsidered because of several features that seem to limit its effectiveness. Over time, SEA has evolved in response to external and internal factors dealing with technical, procedural, planning and governance systems thus involving a shift of paradigm from EIA-based SEAs (first generation protocols) towards more integrated approaches (second generation ones). Changes affecting SEA are formalised through legislation in each Member State, to guide institutions at regional and local level. Defining SEA effectiveness is quite difficult. Its’ capacity-building process appears quite far from its conclusion, even if any definitive version can be conceptualized. In this paper, we consider some European nations with different planning systems and SA traditions. After the identification of some analytical criteria, a multi-dimensional cluster analysis is developed on some case studies, to outline current weaknesses.
Resumo:
The safety, effectiveness and capabilities of therapeutic upper fibreoptic endoscopy in children undergoing therapeutic endoscopic procedures (n = 443) was studied. Therapy for gastrointestinal bleeding formed the major group (injection sclerotherapy for varices, n = 197 procedures; thermocoagulation for haemorrhagic gastritis, n = 1; and photocoaulation for Dieulafoy's disease, n = 1). Sclerotherapy was 97% effective in controlling acute bleeding and 84% effective in obliterating varices with no serious complications or deaths. Oesophageal dilatations for surgical, caustic, congenital and peptic strictures and achalasia (n = 193) were performed with no oesophageal perforations or deaths. Foreign bodies were retrieved (n = 34) with no failures or complications. Percutaneous endoscopic gastrostomy was performed (n = 11) with one failure, proceeding to an unsuccessful surgical gastrostomy. Miscellaneous procedures included endoscopic transpyloric tube placement (n = 5) and endoscopic diathermy of pyloric web (n = 1). Therapeutic fibreoptic endoscopy is therefore concluded to be safe and effective in children, replacing rigid oesophagoscopy and some traditional surgical approaches.
Resumo:
Background: Catheter ablation procedures for atrial fibrillation (AF) may frequently require long fluoroscopic times. We sought to undertake a review of radiation safety practice in our Cardiac Electrophysiology Laboratory and implement changes to minimize fluoroscopic doses. We also sought to compare the results with radiation doses for percutaneous coronary intervention (PCI) cases performed in our hospital. Methods: Fluoroscopic times and doses for AF ablation procedures performed by a single operator on a Philips Integris H3000 image-intensifier were analysed for 11-month period. Results were compared with all PCI procedures performed over a similar period by multiple operators on a Philips Integris Allura FD system. Comprehensive review of radiation practice in the Electrophysiology laboratory identified the potential to reduce pulse frame rates and doses, and to narrow the field of interest without impacting the performance of the procedure. These changes were implemented and results analysed after a further 11 months. Results: In the pre-intervention period 50 AF catheter ablations had a mean fluoroscopic time of 86.4 min and mean fluoroscopic dose 68.4 Gy/cm2. Post-intervention 75 procedures had a mean fluorosocopic time of 68.9 min (p < 0.0001) and mean dose of 14.3 Gy/cm2 (p < 0.0001) 128 PCI procedures had a mean combined fluoroscopic and image acquisition time of 10.0 min and mean total dose 38.8 Gy/cm2. Conclusions: Catheter ablation procedures for AF may require lengthy use of fluoroscopy but simple modifications to radiation practice can result in marked reductions in radiation dose that compare favourably with PCI case doses