68 resultados para Uniscribe ICU


Relevância:

10.00% 10.00%

Publicador:

Resumo:

On Saturday, 25 October 1997 a five year old boy died in the Intensive Care Unit (ICU) of Royal Darwin Hospital (RDH) from meningococcal disease. While disease is expected throughout Australia during the late winter and early spring months, and deaths occur, this case was remarkable in the Northern Territory with respect to the unprecedented public response to media reports of the death.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sedation scales have the potential to facilitate effective procedural sedation and analgesia in the cardiac catheterization laboratory (CCL). For this potential to become realised, a scale that is suitable for use in the CCL either needs to be identified or developed. To identify sedation scales, a review of Medline and CINHAL was conducted. One sedation scale for the CCL, the NASPE SED, and 15 Intensive Care Unit (ICU) scales met the inclusion and exclusion criteria. Analysis of the scale’s item structures and psychometric properties was then performed. None of these scales were deemed suitable for use in the CCL. As such, further research is required to develop a new scale. The new scale should consist of more than one item because it will be the most effective for tracking the patient’s response to medications. Specific tests required to conduct a rigorous evaluation of the new scale’s psychometric properties are outlined in this paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose of review: Artificial corneas are being developed to meet a shortage of donor corneas as well as to address cases where allografting is contraindicated. A range of artificial corneas has been developed. Here we review several newer designs and especially those inspired by naturally occurring biomaterials found with the human body and elsewhere. Recent findings: Recent trends in the development of artificial corneas indicate a move towards the use of materials derived from native sources including decellularized corneal tissue and tissue substitutes synthesized by corneal cells in vitro when grown either on their own, or in conjunction with novel protein-based scaffolds. Biologically inspired materials are also being considered for implantation on their own with the view to promoting endogenous corneal tissue. Summary: More recent attempts at making artificial corneas have taken a more nature-based or nature-inspired approach. Several will in the near future be likely to be available clinically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Less invasive methods of determining cardiac output are now readily available. Using indicator dilution technique, for example has made it easier to continuously measure cardiac output because it uses the existing intra-arterial line. Therefore gone is the need for a pulmonary artery floatation catheter and with it the ability to measure left atrial and left ventricular work indices as well the ability to monitor and measure a mixed venous saturation (SvO2). Purpose The aim of this paper is to put forward the notion that SvO2 provides valuable information about oxygen consumption and venous reserve; important measures in the critically ill to ensure oxygen supply meets cellular demand. In an attempt to portray this, a simplified example of the septic patient is offered to highlight the changing pathophysiological sequelae of the inflammatory process and its importance for monitoring SvO2. Relevance to clinical practice SvO2 monitoring, it could be argued, provides the gold standard for assessing arterial and venous oxygen indices in the critically ill. For the bedside ICU nurse the plethora of information inherent in SvO2 monitoring could provide them with important data that will assist in averting potential problems with oxygen delivery and consumption. However, it has been suggested that central venous saturation (ScvO2) might be an attractive alternative to SvO2 because of its less invasiveness and ease of obtaining a sample for analysis. There are problems with this approach and these are to do with where the catheter tip is sited and the nature of the venous admixture at this site. Studies have shown that ScvO2 is less accurate than SvO2 and should not be used as a sole guiding variable for decision-making. These studies have demonstrated that there is an unacceptably wide range in variance between ScvO2 and SvO2 and this is dependent on the presenting disease, in some cases SvO2 will be significantly lower than ScvO2. Conclusion Whilst newer technologies have been developed to continuously measure cardiac output, SvO2 monitoring is still an important adjunct to clinical decision-making in the ICU. Given the information that it provides, seeking alternatives such as ScvO2 or blood samples obtained from femorally placed central venous lines, can unnecessarily lead to inappropriate treatment being given or withheld. Instead when using ScvO2, trending of this variable should provide clinical determinates that are useable for the bedside ICU nurse, remembering that in most conditions SvO2 will be approximately 16% lower.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this small-scale study was to measure, analyse and compare levels of acoustic noise, in a nine-bedded general intensive care unit (ICU). Measurements were undertaken using the Norsonic 116 sound level meter recording noise levels in the internationally agreed ‘A’ weighted scale. Noise level data were obtained and recorded at 5 min over 3 consecutive days. Results of noise level analysis indicated that mean noise levels within this clinical area was 56·42 dB(A), with acute spikes reaching 80 dB(A). The quietest noise level attained was that of 50 dB(A) during sporadic intervals throughout the 24-h period. Parametric testing using analysis of variance found a positive relationship (p ≤ 0·001) between the nursing shifts and the day of the week. However, Scheffe multiple range testing showed significant differences between the morning shift, and the afternoon and night shifts combined (p ≤ 0·05). There was no statistical difference between the afternoon and night shifts (p ≥ 0·05). While the results of this study may seem self-evident in many respects, what it has highlighted is that the problem of excessive noise exposure within the ICU continues to go unabated. More concerning is that the prolonged effects of excessive noise exposure on patients and staff alike can have deleterious effect on the health and well-being of these individuals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Review question/objective The review objective is to synthesise the best available evidence on experiences and perceptions of family members of intensive care unit patients on the adequacy of end-of-life care, where life-support modalities have been withheld or withdrawn. Inclusion criteria Types of participants This review will consider studies that report on the experiences and perceptions of patients’ families on EOLC in the ICU, where life-support modalities have been withheld or withdrawn. The family is defined as “those who are closest to the patient... the family may include the biological family, family by acquisition, and the family of choice and friends”. Phenomena of interest The phenomena of interest for this review are the patients’ families experiences, perceptions or views on the adequacy of EOLC delivered in the ICU, where life-support modalities were withheld or withdrawn. These experiences may refer to the following views on domains of care considered important at the end-of-life in the ICU, which have been described already in the existing literature: timely, consistent, and compassionate communication, clinician availability, clinical decision making based on patients’ preferences, goals and values, physical care implemented to maintain patient comfort, holistic interdisciplinary care and bereavement care for families of patients who died.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: International epidemic clones (ribotypes 027 and 078) of Clostridium difficile have been associated with death, toxic megacolon and other adverse outcomes in North America and Europe. In 2010, the first local transmission of an epidemic strain (027) of C. difficile was reported in the state of Victoria, Australia, but no cases of infection with this strain were reported in the state of Queensland. In 2012, a prevalence study was undertaken in all public and selected private hospitals to examine the epidemiology of CDI and determine the prevalence of epidemic C. difficile strains in Queensland. Methods: Enhanced surveillance was undertaken on all hospital identified CDI cases aged over 2 years between 10 April and 15 June 2012. Where available, patient samples were cultured and isolates of C. difficile ribotyped. The toxin profile of each isolate was determined by PCR. Results: In total, 168 cases of CDI were identified during the study period. A majority (58.3%) of cases had onset of symptoms in hospital. Of the 62 patients with community onset of symptoms, most (74%) had a hospital admission in the previous 3 months. Only 4 of 168 patients had onset of symptoms within a residential care facility. Thirteen out of the 168 (7.7%) patients included in the study had severe disease (ICU admission and/or death within 30 days of onset). Overall 136/168 (81%) of cases had been prescribed antibiotics in the last month. Of concern was the emergence of a novel ribotype (244) which has recently been described in other parts of Australia and is genetically related to ribotype 027. Seven patients were infected with C. difficile ribotype 244 (8% of 83 samples ribotyped), including one patient requiring ICU admission and one patient who died. Ribotype 244 was tcdA, tcdB and CDT positive and contained a tcdC mutation at position 117. Conclusion: Ongoing surveillance is required to determine the origin and epidemiology of C. difficile ribotype 244 infections in Australia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Increasing health care costs, limited resources and increased demand makes cost effective and cost-efficient delivery of Adolescent Idiopathic Scoliosis (AIS) management paramount. Rising implant costs in deformity correction surgery have prompted analysis of whether high implant densities are justified. The objective of this study was to analyse the costs of thoracoscopic scoliosis surgery, comparing initial learning curve costs with those of the established technique and to the costs involved in posterior instrumented fusion from the literature. METHODS: 189 consecutive cases from April 2000 to July 2011 were assessed with a minimum of 2 years follow-up. Information was gathered from a prospective database covering perioperative factors, clinical and radiological outcomes, complications and patient reported outcomes. The patients were divided into three groups to allow comparison; 1. A learning curve cohort, 2. An intermediate cohort and 3. A third cohort of patients, using our established technique. Hospital finance records and implant manufacturer figures were corrected to 2013 costs. A literature review of AIS management costs and implant density in similar curve types was performed. RESULTS: The mean pre-op Cobb angle was 53°(95%CI 0.4) and was corrected postop to mean 22.9°(CI 0.4). The overall complication rate was 20.6%, primarily in the first cohort, with a rate of 5.6% in the third cohort. The average total costs were $46,732, operating room costs of $10,301 (22.0%) and ICU costs of $4620 (9.8%). The mean number of screws placed was 7.1 (CI 0.04) with a single rod used for each case giving average implant costs of $14,004 (29.9%). Comparison of the three groups revealed higher implant costs as the technique evolved to that in use today, from $13,049 in Group 1 to $14577 in Group 3 (P<0.001). Conversely operating room costs reduced from $10,621 in Group 1 to $7573 (P<0.001) in Group 3. ICU stay was reduced from an average of 1.2 to 0 days. In-patient stay was significantly (P=0.006) lower in Groups 2 and 3 (5.4 days) than Group 1 (5.9 days) (i.e. a reduction in cost of approximately $6,140). CONCLUSIONS: The evolution of our thoracoscopic anterior scoliosis correction has resulted in an increase in the number of levels fused and reduction in complication rate. Implant costs have risen as a result, however, there has been a concurrent decrease in those costs generated by operating room use, ICU and in-patient stay with increasing experience. Literature review of equivalent curve types treated posteriorly shows similar perioperative factors but higher implant density, 69-83% compared to the 50% in this study. Thoracoscopic Scoliosis surgery presents a low density, reliable, efficient and effective option for selected curves. A cost analysis of Thoracoscopic Scoliosis Surgery using financial records and a prospectively collected database of all patients since 2000, demonstrating a clear cost advantage compared to equivalent posterior instrumentation and fusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To explore how registered nurses (RNs) in the general ward perceive discharge processes and practices for patients recently discharged from the intensive care unit (ICU). BACKGROUND: Patients discharged from the ICU environment often require complicated and multifaceted care. The ward-based RN is at the forefront of the care of this fragile patient population, yet their views and perceptions have seldom been explored. DESIGN: A qualitative grounded theory design was used to guide focus group interviews with the RN participants. METHODS: Five semi-structured focus group interviews, including 27 RN participants, were conducted in an Australian metropolitan tertiary referral hospital in 2011. Data analyses of transcripts, field notes and memos used concurrent data generation, constant comparative analysis and theoretical sampling. RESULTS: Results yielded a core category of 'two worlds' stressing the disconnectedness between ICU and the ward setting. This category was divided into sub categories of 'communication disconnect' and 'remember the family'. Properties of 'what we say', 'what we write', 'transfer' and 'information needs' respectively were developed within those sub-categories. CONCLUSION: The discharge process for patients within the ICU setting is complicated and largely underappreciated. There are fundamental, misunderstood differences in prioritisation and care of patients between the areas, with a deep understanding of practice requirements of ward based RNs not being understood. The findings of this research may be used to facilitate inter departmental communications and progress practice development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: In this study, we report on initial efforts to discover putative biomarkers for differential diagnosis of a systemic inflammatory response syndrome (SIRS) versus sepsis; and different stages of sepsis. In addition, we also investigated whether there are proteins that can discriminate between patients who survived sepsis from those who did not. Materials and Methods: Our study group consisted of 16 patients, of which 6 died and 10 survived. We daily measured 28 plasma proteins, for the whole stay of the patients in the ICU. Results: We observed that metalloproteinases and sE-selectin play a role in the distinction between SIRS and sepsis, and that IL-1, IP-10, sTNF-R2 and sFas appear to be indicative for the progression from sepsis to septic shock. A combined measurement of MMP-3, -10, IL-1, IP-10, sIL-2R, sFas, sTNF-R1, sRAGE, GM-CSF, IL-1 and Eotaxin allows for a good separation of patients that survived from those that died (mortality prediction with a sensitivity of 79% and specificity of 86%). Correlation analysis suggests a novel interaction between IL-1a and IP-10. Conclusion: The marker panel is ready to be verified in a validation study with or without therapeutic intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diarrhoea is a common complication observed in critically ill patients. Relationships between diarrhoea, enteral nutrition and aerobic intestinal microflora have been disconnectedly examined in this patient cohort. This research used a two-study, observational design to examine these associations. Higher diarrhoea incidence rates were observed when patients received enteral tube feeding, had abnormal serum blood results, received multiple medications and had aerobic microflora dysbiosis. Further, significant aerobic intestinal microflora changes were observed over time in patients who experienced diarrhoea. These results establish a platform for further work to improve the intestinal health of critically ill patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim The aim of this reflective account is to provide a view of the intensive care unit (ICU) relative’s experiences of supporting and being supported in the ICU. Background Understanding the relatives’ experiences of ICU is important especially because a recent work has identified the potential for this group to develop post-traumatic stress disorder, a condition that is normally equated with the ICU survivor. Design A thematic analysis was used in identifying emerging themes that would be significant in an ICU nursing context. Setting The incident took place in two 8-bedded ICUs (Private and National Health Service) in October. Results Two emergent themes were identified from the reflective story – fear of the technological environment and feeling hopeless and helpless. Conclusion The use of relative stories as an insight into the live experiences of ICU relatives may give a deeper understanding of their life-world. The loneliness, anguish and pain of the ICU relative extends beyond the walls of the ICU, and this is often negated as the focus of the ICU team is the patient. Relevance to clinical practice: Developing strategies to support relatives might include the use of relative diaries used concurrently with patient diaries to support this groups recovery or at the very least a gaining a sense of understanding for their ICU experience. Relative follow-up clinics designed specifically to meet their needs where support and advice can be given by the ICU team, in addition to making timely and appropriate referrals to counselling services and perhaps involving spiritual leaders where appropriate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: The aim of this survey was to assess registered nurse’s perceptions of alarm setting and management in an Australian Regional Critical Care Unit. Background: The setting and management of alarms within the critical care environment is one of the key responsibilities of the nurse in this area. However, with up to 99% of alarms potentially being false-positives it is easy for the nurse to become desensitised or fatigued by incessant alarms; in some cases up to 400 per patient per day. Inadvertently ignoring, silencing or disabling alarms can have deleterious implications for the patient and nurse. Method: A total population sample of 48 nursing staff from a 13 bedded ICU/HDU/CCU within regional Australia were asked to participate. A 10 item open-ended and multiple choice questionnaire was distributed to determine their perceptions and attitudes of alarm setting and management within this clinical area. Results: Two key themes were identified from the open-ended questions: attitudes towards inappropriate alarm settings and annoyance at delayed responses to alarms. A significant number of respondents (93%) agreed that alarm fatigue can result in alarm desensitisation and the disabling of alarms, whilst 81% suggested the key factors are those associated with false-positive alarms and inappropriately set alarms.