189 resultados para Sinter-HIP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Numerous strategies are available to prevent surgical site infections in hip arthroplasty, but there is no consensus on which might be the best. This study examined infection prevention strategies currently recommended for patients undergoing hip arthroplasty. METHODS: Four clinical guidelines on infection prevention/orthopedics were reviewed. Infection control practitioners, infectious disease physicians, and orthopedic surgeons were consulted through structured interviews and an online survey. Strategies were classified as "highly important" if they were recommended by at least one guideline and ranked as significantly or critically important by >/=75% of the experts. RESULTS: The guideline review yielded 28 infection prevention measures, with 7 identified by experts as being highly important in this context: antibiotic prophylaxis, antiseptic skin preparation of patients, hand/forearm antisepsis by surgical staff, sterile gowns/surgical attire, ultraclean/laminar air operating theatres, antibiotic-impregnated cement, and surveillance. Controversial measures included antibiotic-impregnated cement and, considering recent literature, laminar air operating theatres. CONCLUSIONS: Some of these measures may already be accepted as routine clinical practice, whereas others are controversial. Whether these practices should be continued for this patient group will be informed by modeling the cost-effectiveness of infection prevention strategies. This will allow predictions of long-term health and cost outcomes and thus inform decisions on how to best use scarce health care resources for infection control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Impaction bone grafting for reconstitution of bone stock in revision hip surgery has been used for nearly 30 years. We used this technique, in combination with a cemented acetabular component, in the acetabula of 304 hips in 292 patients revised for aseptic loosening between 1995 and 2001. The only additional supports used were stainless steel meshes placed against the medial wall or laterally around the acetabular rim to contain the graft. All Paprosky grades of defect were included. Clinical and radiographic outcomes were collected in surviving patients at a minimum of 10 years following the index operation. Mean follow-up was 12.4 years (SD 1.5; range 10.0-16.0). Kaplan-Meier survivorship with revision for aseptic loosening as the endpoint was 85.9% (95% CI 81.0 to 90.8%) at 13.5 years. Clinical scores for pain relief remained satisfactory, and there was no difference in clinical scores between cups that appeared stable and those that appeared loose radiographically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To synthesise the available evidence and estimate the comparative efficacy of control strategies to prevent total hip replacement (THR)-related surgical site infections (SSIs) using a mixed treatment comparison. DESIGN: Systematic review and mixed treatment comparison. SETTING: Hospital and other healthcare settings. PARTICIPANTS: Patients undergoing THR. PRIMARY AND SECONDARY OUTCOME MEASURES: The number of THR-related SSIs occurring following the surgical operation. RESULTS: 12 studies involving 123 788 THRs and 9 infection control strategies were identified. The strategy of 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation' significantly reduced the risk of THR-related SSI compared with the referent strategy (no systemic antibiotics+plain cement+conventional ventilation), OR 0.13 (95% credible interval (CrI) 0.03-0.35), and had the highest probability (47-64%) and highest median rank of being the most effective strategy. There was some evidence to suggest that 'systemic antibiotics+antibiotic-impregnated cement+laminar airflow' could potentially increase infection risk compared with 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation', 1.96 (95% CrI 0.52-5.37). There was no high-quality evidence that antibiotic-impregnated cement without systemic antibiotic prophylaxis was effective in reducing infection compared with plain cement with systemic antibiotics, 1.28 (95% CrI 0.38-3.38). CONCLUSIONS: We found no convincing evidence in favour of the use of laminar airflow over conventional ventilation for prevention of THR-related SSIs, yet laminar airflow is costly and widely used. Antibiotic-impregnated cement without systemic antibiotics may not be effective in reducing THR-related SSIs. The combination with the highest confidence for reducing SSIs was 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation'. Our evidence synthesis underscores the need to review current guidelines based on the available evidence, and to conduct further high-quality double-blind randomised controlled trials to better inform the current clinical guidelines and practice for prevention of THR-related SSIs.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In an attempt to preserve proximal femoral bone stock and achieve a better fit in smaller femora, especially in the Asian population, several new shorter stem designs have become available. We investigated the torque to periprosthetic femoral fracture of the Exeter short stem compared with the conventional length Exeter stem in a Sawbone model. 42 stems; 21 shorter and 21 conventional stems both with three different offsets were cemented in a composite Sawbone model and torqued to fracture. Results showed that Sawbone femurs break at a statistically significantly lower torque to failure with a shorter compared to conventional length Exeter stem of the same offset. Both standard and short stem designs are safe to use as the torque to failure is 7-10 times that seen in activities of daily living.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Metal ion release is common following total hip arthroplasty, yet postoperative levels have not been defined for most stems currently used in clinical practice. AIM: To assess metal ion release in the serum of patients with well functioning unilateral Exeter V40 primary total hip arthroplasties one year after surgery. METHODS: Whole blood chromium and serum cobalt levels were measured in 20 patients following primary total hip arthroplasty with the Exeter V40 stem and a variety of acetabular components one year after surgery. RESULTS: Whole blood chromium levels were within the normal range (10-100 nmol/L), with a single mild elevation of serum cobalt (normal < 20 nmol/L). CONCLUSION: In well functioning primary unilateral total hip arthroplasty using the Exeter V40 stem with a variety of acetabular components one year post surgery, whole blood chromium levels are normal and serum cobalt elevations are rare and mild.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study aimed to examine the geometric and dosimetric results when radiotherapy treatment plans are designed for prostate cancer patients with hip prostheses. Methods Ten EBRT treatment plans for localised prostate cancer, in the presence of hip prostheses, were analysed and compared with a reference set of 196 treatment plans for localised prostate cancer in patients without prostheses. Crowe et al.’s TADA code [1] was used to extract treatment plan parameters and evaluate doses to target volumes and critical structures against recommended goals [2] and constraints [3, 4]. Results The need to avoid transmitting the radiation beam through the hip prostheses limited the range of gantry angles available for use in both the rotational (VMAT) and the non-rotational (3DCRT and IMRT) radiotherapy treatments. This geometric limitation (exemplified in the VMAT data shown in Fig. 1) reduced the overall quality of the treatment plans for patients with prostheses compared to the reference plans. All plans with prostheses failed the PTV dose homogeneity requirement [2], whereas only 4 % of the plans without prostheses failed this test. Several treatment plans for patients with hip prostheses also failed the QUANTEC requirements that less than 50 % of the rectum receive 50 Gy and less than 35 % of the rectum receive 60 Gy to keep the grade 3 toxicity rate below 10 % [3], or the Hansen and Roach requirement that less than 25 % of the bladder receive 75 Gy [4]. Discussion and conclusions The results of this study exemplify the difficulty of designing prostate radiotherapy treatment plans, where beams provide adequate doses to targeted tissues while avoiding nearby organs at risk, when the presence of hip prostheses limits the available treatment geometries. This work provides qualitative evidence of the compromised dose distributions that can result, in such cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mortality following hip arthroplasty is affected by a large number of confounding variables each of which must be considered to enable valid interpretation. Relevant variables available from the 2011 NJR data set were included in the Cox model. Mortality rates in hip arthroplasty patients were lower than in the age-matched population across all hip types. Age at surgery, ASA grade, diagnosis, gender, provider type, hip type and lead surgeon grade all had a significant effect on mortality. Schemper's statistic showed that only 18.98% of the variation in mortality was explained by the variables available in the NJR data set. It is inappropriate to use NJR data to study an outcome affected by a multitude of confounding variables when these cannot be adequately accounted for in the available data set.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Periprosthetic joint infection (PJI) after THA is a major complication with an incidence of 1-3%. We report our experiences with a technique using a custom-made articulating spacer (CUMARS) at the first of two-stage treatment for PJI. This technique uses widely available all-polyethylene acetabular components and the Exeter Universal stem, fixed using antibiotic loaded acrylic cement. Seventy-six hips were treated for PJI using this technique. Performed as the first of a two-stage procedure, good functional results were commonly seen, leading to postponing second stage indefinitely with retention of the CUMARS prosthesis in 34 patients. The CUMARS technique presents an alternative to conventional spacers, using readily available components that are well tolerated, allowing weight bearing and mobility, and achieving comparable eradication rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validity of fatigue protocols involving multi-joint movements, such as stepping, has yet to be clearly defined. Although surface electromyography can monitor the fatigue state of individual muscles, the effects of joint angle and velocity variation on signal parameters are well established. Therefore, the aims of this study were to i) describe sagittal hip and knee kinematics during repetitive stepping ii) identify periods of high inter-trial variability and iii) determine within-test reliability of hip and knee kinematic profiles. A group of healthy men (N = 15) ascended and descended from a knee-high platform wearing a weighted vest (10%BW) for 50 consecutive trials. The hip and knee underwent rapid flexion and extension during step ascent and descent. Variability of hip and knee velocity peaked between 20-40% of the ascent phase and 80-100% of the descent. Significant (p<0.05) reductions in joint range of motion and peak velocity during step ascent were observed, while peak flexion velocity increased during descent. Healthy individuals use complex hip and knee motion to negotiate a knee-high step with kinematic patterns varying across multiple repetitions. These findings have important implications for future studies intending to use repetitive stepping as a fatigue model for the knee extensors and flexors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In an attempt to reduce stress shielding in the proximal femur multiple new shorter stem design have become available. We investigated the load to fracture of a new polished tapered cemented short stem in comparison to the conventional polished tapered Exeter stem. Method: A total of forty-two stems, twenty-one short stems and twenty-one conventional stems both with three different offsets were cemented in a composite sawbone model and loaded to fracture. Results: study showed that femurs will break at a significantly lower load to failure with a shorter compared to conventional length Exeter stem. Conclusion: This Both standard and short stem design are safe to use as the torque to failure is 7–10 times as much as the torques seen in activities of daily living.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Clinical guidelines for the treatment of chronic low back pain suggest the use of supervised exercise. Motor control (MC) based exercise is widely used within clinical practice but its efficacy is equivalent to general exercise therapy. MC exercise targets the trunk musculature. Considering the mechanical links between the hip, pelvis, and lumbar spine, surprisingly little focus has been on investigating the contribution of the hip musculature to lumbopelvic support. The purpose of this study is to compare the efficacy of two exercise programs for the treatment of non-specific low back pain (NSLBP). Methods Eighty individuals aged 18-65 years of age were randomized into two groups to participate in this trial. The primary outcome measures included self-reported pain intensity (0-100mm VAS) and percent disability (Oswestry Disability Index V2). Bilateral measures of hip strength (N/kg) and two dimensional frontal plane mechanics (º) were the secondary outcomes. Outcomes were measured at baseline and following a six-week home based exercise program including weekly sessions of real-time ultrasound imaging. Results Within group comparisons revealed clinically meaningful reductions in pain for both groups. The MC exercise only (N= 40, xˉ =-20.9mm, 95%CI -25.7, -16.1) and the combined MC and hip exercise (N= 40, xˉ = -24.9mm, 95%CI -30.8, -19.0). There was no statistical difference in the change of pain (xˉ =-4.0mm, t= -1.07, p=0.29, 95%CI -11.5, 3.5) or disability (xˉ =-0.3%, t=-0.19, p=0.85, 95%CI -11.5, 3.5) between groups. Conclusion Both exercise programs had similar and positive effects on NSLBP which support the use of the home based exercise programs with weekly supervised visits. However, the addition of specific hip strengthening exercises to a MC based exercise program did not result in significantly greater reductions in pain or disability. Trial Registration NCTO1567566 Funding: Worker’s Compensation Board Alberta Research Grant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate limb loading and dynamic stability during squatting in the early functional recovery of total hip arthroplasty (THA) patients. Design: Cohort study Setting: Inpatient rehabilitation clinic. Participants: A random sample of 61 THA patients (34♂/27♀; 62±9 yrs, 77±14 kg, 174±9 cm) was assessed twice, 13.2±3.8 days (PRE) and 26.6±3.3 days post-surgery (POST), and compared with a healthy reference group (REF) (22♂/16♀; 47±12yrs; 78±20kg; 175±10cm). Interventions: THA patients received two weeks of standard in-patient rehabilitation. Main Outcome Measure(s): Inter-limb vertical force distribution and dynamic stability during the squat maneuver, as defined by the root mean square (RMS) of the center of pressure in antero-posterior and medio-lateral directions, of operated (OP) and non-operated (NON)limbs. Self-reported function was assessed via FFb-H-OA 2.0 questionnaire. Results: At PRE, unloading of the OP limb was 15.8% greater (P<.001, d=1.070) and antero-posterior and medio-lateral center of pressure RMS were 30-34% higher in THA than REF P<.05). Unloading was reduced by 12.8% towards a more equal distribution from PRE to POST (P<.001, d=0.874). Although medio-lateral stability improved between PRE and POST (OP: 14.8%, P=.024, d=0.397; NON: 13.1%, P=.015, d=0.321), antero-posterior stability was not significantly different. Self-reported physical function improved by 15.8% (P<.001, d=0.965). Conclusion(s): THA patients unload the OP limb and are dynamically more unstable during squatting in the early rehabilitation phase following total hip replacement than healthy adults. Although loading symmetry and medio-lateral stability improved to the level of healthy adults with rehabilitation, antero-posterior stability remained impaired. Measures of dynamic stability and load symmetry during squatting provide quantitative information that can be used to clinically monitor early functional recovery from THA.