89 resultados para STIMULATION-PRODUCED ANALGESIA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Analgesia and early quality of recovery may be improved by epidural analgesia. We aimed to assess the effect of receiving epidural analgesia on surgical adverse events and quality of life after laparotomy for endometrial cancer. Methods Patients were enrolled in an international, multicentre, prospective randomised trial of outcomes for laparoscopic versus open surgical treatment for the management of apparent stage I endometrial cancer (LACE trial). The current analysis focussed on patients who received an open abdominal hysterectomy via vertical midline incision only (n = 257), examining outcomes in patients who did (n = 108) and did not (n = 149) receive epidural analgesia. Results Baseline characteristics were comparable between patients with or without epidural analgesia. More patients without epidural (34%) ceased opioid analgesia 3–5 days after surgery compared to patients who had an epidural (7%; p < 0.01). Postoperative complications (any grade) occurred in 86% of patients with and in 66% of patients without an epidural (p < 0.01) but there was no difference in serious adverse events (p = 0.19). Epidural analgesia was associated with increased length of stay (up to 48 days compared to up to 34 days in the non-epidural group). There was no difference in postoperative quality of life up to six months after surgery. Conclusions Epidural analgesia was associated with an increase in any, but not serious, postoperative complications and length of stay after abdominal hysterectomy. Randomised controlled trials are needed to examine the effect of epidural analgesia on surgical adverse events, especially as the present data do not support a quality of life benefit with epidural analgesia. Keywords Endometrial cancer; Hysterectomy; Epidural; Adverse events

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Calculating segmental torso masses in Adolescent Idiopathic Scoliosis (AIS) patients allows the gravitational loading on the scoliotic spine during relaxed standing to be estimated. Methods Low dose CT data was used to calculate vertebral level-by-level torso masses and spinal joint torques for 20 female AIS patients (mean age 15.0 ± 2.7 years, mean Cobb angle 53 ± 7.1°). ImageJ software (v1.45 NIH USA) was used to threshold the T1 to L5 CT images and calculate the segmental torso volume and mass for each vertebral level. Masses for the head, neck and arms were taken from published data.1 Intervertebral joint torques in the coronal and sagittal planes at each vertebral level were found from the position of the centroid of the segment masses relative to the joint centres (assumed to be at the centre of the intervertebral disc). The joint torque at each level was found by summing torque contributions for all segments above that joint. Results Segmental torso mass increased from 0.6kg at T1 to 1.5kg at L5. The coronal plane joint torques due to gravity were 5-7Nm at the apex of the curve; sagittal torques were 3-5.4Nm. Conclusion CT scans were in the supine position and curve magnitudes are known to be smaller than those in standing.2 Hence, this study has shown that gravity produces joint torques potentially of higher than 7Nm in the coronal plane and 5Nm in the sagittal plane during relaxed standing in scoliosis patients. The magnitude of these torques may help to explain the mechanics of AIS progression and the mechanics of bracing. This new data on torso segmental mass in AIS patients will assist biomechanical models of scoliosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report major and trace element composition, Sr–Nd isotopic and seismological data for a picrite–basalt–rhyolite suite from the northern Tarim uplift (NTU), northwest China. The samples were recovered from 13 boreholes at depths between 5,166 and 6,333 m. The picritic samples have high MgO (14.5–16.8 wt%, volatiles included) enriched in incompatible element and have high 87Sr/86Sr and low 143Nd/144Nd isotopic ratios (εNd (t) = −5.3; Sri = 0.707), resembling the Karoo high-Ti picrites. All the basaltic samples are enriched in TiO2 (2.1–3.2 wt%, volatiles free), have high FeOt abundances (11.27–15.75 wt%, volatiles free), are enriched in incompatible elements and have high Sr and low Nd isotopic ratios (Sri = 0.7049–0.7065; εNd (t) = −4.1 to −0.4). High Nb/La ratios (0.91–1.34) of basalts attest that they are mantle-derived magma with negligible crustal contamination. The rhyolite samples can be subdivided into two coeval groups with overlapping U–Pb zircon ages between 291 ± 4 and 272 ± 2 Ma. Group 1 rhyolites are enriched in Nb and Ta, have similar Nb/La, Nb/U, and Sr–Nd isotopic compositions to the associated basalts, implying that they are formed by fractional crystallization of the basalts. Group 2 rhyolites are depleted in Nb and Ta, have low Nb/La ratios, and have very high Sr and low Nd isotopic ratios, implying that crustal materials have been extensively, if not exclusively, involved in their source. The picrite–basalt–rhyolite suite from the NTU, together with Permian volcanic rocks from elsewhere Tarim basin, constitute a Large Igneous Province (LIP) that is characterized by large areal extent, rapid eruption, OIB-type chemical composition, and eruption of high temperature picritic magma. The Early Permian magmatism, which covered an area >300,000 km2, is therefore named the Tarim Flood Basalt.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compromised angiogenesis appears to be a major limitation in various suboptimal bone healing situations. Appropriate mechanical stimuli support blood vessel formation in vivo and improve healing outcomes. However, the mechanisms responsible for this association are unclear. To address this question, the paracrine angiogenic potential of early human fracture haematoma and its responsiveness to mechanical loading, as well as angiogenic growth factors involved, were investigated in vitro. Human haematomas were collected from healthy patients undergoing surgery within 72. h after bone fracture. The haematomas were embedded in a fibrin matrix, and cultured in a bioreactor resembling the in vivo conditions of the early phase of bone healing (20 compression, 1. Hz) over 3. days. Conditioned medium (CM) from the bioreactor was then analyzed. The matrices were also incubated in fresh medium for a further 24. h to evaluate the persistence of the effects. Growth factor (GF) concentrations were measured in the CM by ELISAs. In vitro tube formation assays were conducted on Matrigel with the HMEC-1 cell line, with or without inhibition of vascular endothelial growth factor receptor 2 (VEGFR2). Cell numbers were quantified using an MTS test. In vitro endothelial tube formation was enhanced by CM from haematomas, compared to fibrin controls. The angiogenesis regulators, vascular endothelial growth factor (VEGF) and transforming growth factor β1 (TGF-β1), were released into the haematoma CM, but not angiopoietins 1 or 2 (Ang1, 2), basic fibroblast growth factor (bFGF) or platelet-derived growth factor (PDGF). Mechanical stimulation of haematomas, but not fibrin controls, further increased the induction of tube formation by their CM. The mechanically stimulated haematoma matrices retained their elevated pro-angiogenic capacity for 24. h. The pro-angiogenic effect was cancelled by inhibition of VEGFR2 signalling. VEGF concentrations in CM tended to be elevated by mechanical stimulation; this was significant in haematomas from younger, but not from older patients. Other GFs were not mechanically regulated. In conclusion, the paracrine pro-angiogenic capacity of early human haematomas is enhanced by mechanical stimulation. This effect lasts even after removing the mechanical stimulus and appears to be VEGFR2-dependent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This small-scale study was undertaken to assess what knowledge nursing staff from a General Intensive Care Unit held with regard to noise exposure. To assess knowledge a self-administered multiple-choice questionnaire was used. Rigorous peer-review insured content validity. This study produced poor results in terms of the knowledge nurses held with regard to noise related issues in particular the psychophysiological effects and current legislation concerning its safe exposure. Non-parametric testing, using Kruskal–Wallis found no significant difference between nursing grades, however, descriptive analysis demonstrated that the staff nurse grade (D and E) performed better overall. Whilst the results of this study may seem self-evident in some respects, it is the problems of exposure to excessive noise levels for both patients and hospital personnel, which are clearly not understood. The effects noise exposure has on individuals for example decreased wound healing; sleep deprivation and cardiovascular stimulation must be of concern especially in terms of patient care but more so for nursing staff especially the effects noise levels can have on cognitive task performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymer biomaterials have been widely used for bone replacement/regeneration because of their unique mechanical properties and workability. Their inherent low bioactivity makes them lack osseointegration with host bone tissue. For this reason, bioactive inorganic particles have been always incorporated into the matrix of polymers to improve their bioactivity. However, mixing inorganic particles with polymers always results in inhomogeneity of particle distribution in polymer matrix with limited bioactivity. This study sets out to apply the pulsed laser deposition (PLD) technique to prepare uniform akermanite (Ca2MgSi2O7, AKT) glass nanocoatings on the surface of two polymers (non-degradable polysulfone (PSU) and degradable polylactic acid (PDLLA)) in order to improve their surface osteogenic and angiogenic activity. The results show that a uniform nanolayer composed of amorphous AKT particles (∼30nm) of thickness 130nm forms on the surface of both PSU and PDLLA films with the PLD technique. The prepared AKT-PSU and AKT-PDLLA films significantly improved the surface roughness, hydrophilicity, hardness and apatite mineralization, compared with pure PSU and PDLLA, respectively. The prepared AKT nanocoatings distinctively enhance the alkaline phosphate (ALP) activity and bone-related gene expression (ALP, OCN, OPN and Col I) of bone-forming cells on both PSU and PDLLA films. Furthermore, AKT nanocoatings on two polymers improve the attachment, proliferation, VEGF secretion and expression of proangiogenic factors and their receptors of human umbilical vein endothelial cells (HUVEC). The results suggest that PLD-prepared bioceramic nanocoatings are very useful for enhancing the physicochemical, osteogenic and angiogenic properties of both degradable and non-degradable polymers for application in bone replacement/regeneration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a study of ion exchange (IX) as an alternative CSG water treatment to the widely used reverse osmosis (RO) desalination process. An IX pilot plant facility has been constructed and operated using both synthetic and real CSG water samples. Application of appropriate synthetic resin technology has proved the effectiveness of IX processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have previously reported that human breast carcinoma (HBC) cell lines expressing the mesenchymal intermediate filament protein vimentin (VIM+) are highly invasive in vitro, and highly metastatic in nude mice when compared to their VIM- counterparts. Since only VIM+ cell lines can be induced to activate matrix metalloproteinase-2 (MMP-2) upon stimulation with Concanavalin A (Con A), we have examined here membrane type 1 MMP (MT1-MMP), a cell surface activator of MMP-2. Northern analysis reveals baseline expression of MT1-MMP in five of the six VIM+ cell lines studied (MDA-MB-231, MDA-MB-435, BT-549, Hs578T, MCF-7(ADR)), each of which showed variable activation of exogenous MMP-2 after treatment with Con A. In contrast, the four VIM-, poorly invasive HBC cell lines studied (MCF-7, T47D, MDA-MB 468, ZR-75-1) lacked baseline MT1-MMP mRNA expression, and showed no induction of either MT1-MMP expression or MMP-2-activation with Con A. Such differential MT1-MMP expression was confirmed in vivo using in situ hybridization analysis of nude mouse tumor xenografts of representative cell lines. Western analysis of the MDA-MB-231 cells revealed baseline membrane expression of a 60 kDa species, which was strongly induced by Con A treatment along with a weaker band co-migrating with that from MT1-MMP-transfected COS-1 cells (63 kDa), presumably representing latent MT1-MMP. MT1-MMP immunofluorescence strongly decorated Con A-stimulated MDA-MB-231 cells in a manner consistent with membranous staining, but did not decorate the unstimulated MDA-MB-231 cells or MCF-7 cells under either condition. Collectively, the results suggest the constitutive production of active MT1-MMP which is unavailable for either MMP-2 activation or immuno-decoration until Con A treatment. Since VIM expression arises by virtue of the so-called epithelial to mesenchymal transition (EMT) in invasive embryonic epithelia, we propose that this represents a major metastasis mechanism in breast carcinomas. MT1-MMP on the surface of such 'fibroblastoid' carcinoma cells may mediate a paracrine loop for the utilization of stromally produced MMP-2, and contribute to the poorer survival associated with VIM+ breast carcinomas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Calculating segmental torso masses in Adolescent Idiopathic Scoliosis (AIS) patients allows the gravitational loading on the scoliotic spine during relaxed standing to be estimated. Methods Low dose CT data was used to calculate vertebral level-by-level torso masses and spinal joint torques for 20 female AIS patients (mean age 15.0 ± 2.7 years, mean Cobb angle 53 ± 7.1°). ImageJ software (v1.45 NIH USA) was used to threshold the T1 to L5 CT images and calculate the segmental torso volume and mass for each vertebral level. Masses for the head, neck and arms were taken from published data. Intervertebral joint torques in the coronal and sagittal planes at each vertebral level were found from the position of the centroid of the segment masses relative to the joint centres (assumed to be at the centre of the intervertebral disc. The joint torque at each level was found by summing torque contributions for all segments above that joint. Results Segmental torso mass increased from 0.6kg at T1 to 1.5kg at L5. The coronal plane joint torques due to gravity were 5-7Nm at the apex of the curve; sagittal torques were 3-5.4Nm. Conclusion CT scans were in the supine position and curve magnitudes are known to be smaller than those in standing. Hence, this study has shown that gravity produces joint torques potentially of higher than 7Nm in the coronal plane and 5Nm in the sagittal plane during relaxed standing in scoliosis patients. The magnitude of these torques may help to explain the mechanics of AIS progression and the mechanics of bracing. This new data on torso segmental mass in AIS patients will assist biomechanical models of scoliosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phase-selective synthesis of copper oxide nanowires is warranted by several applications, yet it remains challenging because of the narrow windows of the suitable temperature and precursor gas composition in thermal processes. Here, we report on the room-temperature synthesis of small-diameter, large-area, uniform, and phase-pure Cu2O nanowires by exposing copper films to a custom-designed low-pressure, thermally non-equilibrium, high-density (typically, the electron number density is in the range of 10 11-1013cm-3) inductively coupled plasmas. The mechanism of the plasma-enabled phase selectivity is proposed. The gas sensors based on the synthesized Cu2O nanowires feature fast response and recovery for the low-temperature (∼140°C) detection of methane gas in comparison with polycrystalline Cu2O thin film-based gas sensors. Specifically, at a methane concentration of 4%, the response and the recovery times of the Cu2O nanowire-based gas sensors are 125 and 147s, respectively. The Cu2O nanowire-based gas sensors have a potential for applications in the environmental monitoring, chemical industry, mining industry, and several other emerging areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous high surface area thin films of nanosheet-shaped monoclinic MoO 3 were deposited onto platinized Si substrates using patch antenna-based atmospheric microplasma processing. The films were characterized by high resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM) and electrochemical analysis. The electrochemical analysis shows original redox peaks and high charge capacity, and also indicates a reversible electrochemical behaviour particularly beneficial for applications in Li-ion batteries. SEM shows that the films are highly porous and consist of nanosheets 50-100 nm thick with surface dimensions in the micrometre range. HRTEM reveals that the MoO3 nanosheets consist of the monoclinic beta phase of MoO3. These intricate nanoarchitectures made of monoclinic MoO3 nanosheets have not been studied previously in the context of applications in Li-ion batteries and show superior structural and morphological features that enable effective insertion of Li ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To evaluate quality of care delivered to patients presenting to the emergency department (ED) with pain and managed by emergency nurse practitioners by measuring: 1) Evaluate time to analgesia from initial presentation 2) Evaluate time from being seen to next analgesia 3) Pain score documentation Background The delivery of quality care in the emergency department (ED) is emerging as one of the most important service indicators being measured by health services. Emergency nurse practitioner services are designed to improve timely, quality care for patients. One of the goals of quality emergency care is the timely and effective delivery of analgesia for patients. Timely analgesia is an important indicator of ED service performance. Methods A retrospective explicit chart review of 128 consecutive patients with pain and managed by emergency nurse practitioners was conducted. Data collected included demographics, presenting complaint, pain scores, and time to first dose of analgesia. Patients were identified from the ED Patient Information System (Cerner log) and data were extracted from electronic medical records Results Pain scores were documented in 67 (52.3%; 95% CI: 43.3-61.2) patients. The median time to analgesia from presentation was 60.5 (IQR 30-87) minutes, with 34 (26.6%; 95% CI: 19.1-35.1) patients receiving analgesia within 30 minutes of presentation to hospital. There were 22 (17.2%; 95% CI: 11.1-24.9) patients who received analgesia prior to assessment by a nurse practitioner. Among patients that received analgesia after assessment by a nurse practitioner, the median time to analgesia after assessment was 25 (IQR 12-50) minutes, with 65 (61.3%; 95% CI: 51.4-70.6) patients receiving analgesia within 30 minutes of assessment. Conclusions The majority of patients assessed by nurse practitioners received analgesia within 30 minutes after assessment. However, opportunities for substantial improvement in such times along with documentation of pain scores were identified and will be targeted in future research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A theoretical model of the plasma discharge in a metal cylinder pumped by an operating gas of an arbitrary nature is presented. The ionization is carried out by the surface wave (SW) propagating along a coaxial metal wire. The model includes the local dispersion relation, the energy balance equation, and the relation between the absorbed power per unit length and the local plasma density. Two typical regimes of the discharge are analyzed. In both regimes the axial and radial profiles of the plasma density of the electromagnetic field components and of the SW intensity are obtained. The possible use of the obtained results in plasma technology are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structure of a microwave gas discharge produced and sustained by a surface wave (SW) propagating along a cylindrical metal antenna with a dielectric coating is studied. The SW that produces and sustains the microwave gas discharge propagates along an external magnetic field and has an eigenfrequency in the range between the electron cyclotron and electron plasma frequencies. The presence of a dielectric (vacuum) sheath region separating the antenna from the plasma is assumed. The spatial distributions of the produced plasma density, electromagnetic fields, energy flow density, phase velocity and reverse skin depth of the SW are obtained analytically and numerically.