127 resultados para LESS-THAN -5.0


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To profile Australian nurse practitioners and their practice in 2009 and compare results with a similar 2007 census. Methods. Self-administered questionnaire. Results. Atotal of 293 nurse practitioners responded (response rate 76.3%). The majority were female (n = 229, 81.2%); mean age was 47.3 years (s.d. = 8.1). As in 2007, emergency nurse practitioners represented the largest clinical specialty (n = 63, 30.3%). A majority practiced in a metropolitan area (n = 133, 64.3%); a decrease from 2007. Consistent with 2007, only 71.5% (n = 208) were employed as a nurse practitioner and 22.8% (n = 46) were awaiting approval for some or all of their clinical protocols. Demographic data, allocations of tasks, and patterns of practice remained consistent with 2007 results. ‘No Medicare provider number’ (n = 182, 91.0%), ‘no authority to prescribe using the Pharmaceutical Benefits Scheme’ (n = 182, 89.6%) and ‘lack of organisational support’ (n = 105, 52.2%) were reported as ‘limiting’ or ‘extremely limiting’ to practice. Conclusions. Our results demonstrate less than satisfactory uptake of the nurse practitioner role despite authorisation. Barriers constraining nurse practitioner practice reduced but remained unacceptably high. Adequate professional and political support is necessary to ensure the efficacy and sustainability of this clinical role.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Membranes prepared from a protein, fibroin, isolated from domesticated silkworm (Bombyx mori) silk, support the cultivation of human limbal epithelial (HLE) cells and thus display significant potential as biomaterials for ocular surface reconstruction. We presently extend this promising avenue of research by directly comparing the attachment, morphology and phenotype of primary HLE cell cultures grown on fibroin to that observed on donor amniotic membrane (AM), the current clinical standard substrate for HLE transplantation. Fibroin membranes measuring 6.3 ± 0.5 μm (mean ± sd) in thickness and permeable to FITC dextran of a molecular weight up to 70 kDa, were used. Attachment of HLE cells to fibroin was similar to that supported by tissue culture plastic but approximately 6-fold less than that observed on AM. Nevertheless, epithelia constructed from HLE on fibroin maintained evidence of corneal phenotype (K3/K12 expression) and displayed a comparable number and distribution of ΔNp63+ progenitor cells to that seen in cultures grown on AM. These results support the suitability of membranes constructed from Bombyx mori silk fibroin as substrata for HLE cultivation and encourage progression to studies of efficacy in preclinical models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Childhood sun exposure has been associated with increased risk of developing melanoma later in life. Sunscreen, children.s preferred method of sun protection, has been shown to reduce skin cancer risk. However, the effectiveness of sunscreen is largely dependent on user compliance, such as the thickness of application. To reach the sun protection factor (SPF) sunscreen must be applied at a thickness of 2mg/cm2. It has been demonstrated that adults tend to apply less than half of the recommended 2mg/cm2. This was the first study to measure the thickness at which children apply sunscreen. We recruited 87 primary school aged children (n=87, median age 8.7, 5-12 years) from seven state schools within one Brisbane education district (32% consent rate). The children were supplied with sunscreen in three dispenser types (pump, squeeze and roll-on) and were asked to use these for one week each. We measured the weight of the sunscreen before and after use, and calculated the children.s body surface area (based on height and weight) and area to which sunscreen was applied (based on children.s self-reported body coverage of application). Combined these measurements resulted in an average thickness of sunscreen application, which was our main outcome measure. We asked parents to complete a self-administered questionnaire which captured information about potential explanatory variables. Children applied sunscreen at a median thickness of 0.48mg/cm2, significantly less than the recommended 2mg/cm2 (p<0.001). When using the roll-on dispenser (median 0.22mg/cm2), children applied significantly less sunscreen thickness, compared to the pump (median 0.75mg.cm2, p<0.001), and squeeze (median 0.57mg/cm2, p<0.001) dispensers. School grade (1-7) was significantly associated with thickness of application (p=0.032), with children in the youngest grades applying the most. Other variables that were significantly associated with the outcome variable included: number of siblings (p=0.001), household annual income (p<0.001), and the number of lifetime sunburns the child had experienced (p=0.007). This work is the first to measure children.s sunscreen application thickness and demonstrates that regardless of their age or the type of dispenser that they use, children do not apply enough sunscreen to reach the advertised SPF. It is envisaged that this study will assist in the formulation of recommendations for future research, practice and policy aimed at improving childhood sun protection to reduce skin cancer incidence in the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The interaction and relationship between the global warming and the thermal performance buildings are dynamic in nature. In order to model and understand this behavior, different approaches, including keeping weather variable unchanged, morphing approach and diurnal modelling method, have been used to project and generate future weather data. Among these approaches, various assumptions on the change of solar radiation, air humidity and/or wind characteristics may be adopted. In this paper, an example to illustrate the generation of future weather data for the different global warming scenarios in Australia is presented. The sensitivity of building cooling loads to the possible changes of assumed values used in the future weather data generation is investigated. It is shown that with ± 10% change of the proposed future values for solar radiation, air humidity or wind characteristics, the corresponding change in the cooling load of the modeled sample office building at different Australian capital cities would not exceed 6%, 4% and 1.5% respectively. It is also found that with ±10% changes on the proposed weather variables for both the 2070-high future scenario and the current weather scenario, the corresponding change in the cooling loads at different locations may be weaker (up to 2% difference in Hobart for ±10% change in global solar radiation), similar (less than 0.6%) difference in Hobart for ±10% change in wind speed), or stronger (up to 1.6% difference in Hobart for ±10% change in relative humidity) in the 2070-high future scenario than in the current weather scenario.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is frequently reported that the actual weight loss achieved through exercise interventions is less than theoretically expected. Amongst other compensatory adjustments that accompany exercise training (e.g., increases in resting metabolic rate and energy intake), a possible cause of the less than expected weight loss is a failure to produce a marked increase in total daily energy expenditure due to a compensatory reduction in non-exercise activity thermogenesis (NEAT). Therefore, there is a need to understand how behaviour is modified in response to exercise interventions. The proposed benefits of exercise training are numerous, including changes to fat oxidation. Given that a diminished capacity to oxidise fat could be a factor in the aetiology of obesity, an exercise training intensity that optimises fat oxidation in overweight/obese individuals would improve impaired fat oxidation, and potentially reduce health risks that are associated with obesity. To improve our understanding of the effectiveness of exercise for weight management, it is important to ensure exercise intensity is appropriately prescribed, and to identify and monitor potential compensatory behavioural changes consequent to exercise training. In line with the gaps in the literature, three studies were performed. The aim of Study 1 was to determine the effect of acute bouts of moderate- and high-intensity walking exercise on NEAT in overweight and obese men. Sixteen participants performed a single bout of either moderate-intensity walking exercise (MIE) or high-intensity walking exercise (HIE) on two separate occasions. The MIE consisted of walking for 60-min on a motorised treadmill at 6 km.h-1. The 60-min HIE session consisted of walking in 5-min intervals at 6 km.h-1 and 10% grade followed by 5-min at 0% grade. NEAT was assessed by accelerometer three days before, on the day of, and three days after the exercise sessions. There was no significant difference in NEAT vector magnitude (counts.min-1) between the pre-exercise period (days 1-3) and the exercise day (day 4) for either protocol. In addition, there was no change in NEAT during the three days following the MIE session, however NEAT increased by 16% on day 7 (post-exercise) compared with the exercise day (P = 0.32). During the post-exercise period following the HIE session, NEAT was increased by 25% on day 7 compared with the exercise day (P = 0.08), and by 30-33% compared with the pre-exercise period (day 1, day 2 and day 3); P = 0.03, 0.03, 0.02, respectively. To conclude, a single bout of either MIE or HIE did not alter NEAT on the exercise day or on the first two days following the exercise session. However, extending the monitoring of NEAT allowed the detection of a 48 hour delay in increased NEAT after performing HIE. A longer-term intervention is needed to determine the effect of accumulated exercise sessions over a week on NEAT. In Study 2, there were two primary aims. The first aim was to test the reliability of a discontinuous incremental exercise protocol (DISCON-FATmax) to identify the workload at which fat oxidation is maximised (FATmax). Ten overweight and obese sedentary male men (mean BMI of 29.5 ¡Ó 4.5 kg/m2 and mean age of 28.0 ¡Ó 5.3 y) participated in this study and performed two identical DISCON-FATmax tests one week apart. Each test consisted of alternate 4-min exercise and 2-min rest intervals on a cycle ergometer. The starting work load of 28 W was increased every 4-min using 14 W increments followed by 2-min rest intervals. When the respiratory exchange ratio was consistently >1.0, the workload was increased by 14 W every 2-min until volitional exhaustion. Fat oxidation was measured by indirect calorimetry. The mean FATmax, ƒtV O2peak, %ƒtV O2peak and %Wmax at which FATmax occurred during the two tests were 0.23 ¡Ó 0.09 and 0.18 ¡Ó 0.08 (g.min-1); 29.7 ¡Ó 7.8 and 28.3 ¡Ó 7.5 (ml.kg-1.min-1); 42.3 ¡Ó 7.2 and 42.6 ¡Ó 10.2 (%ƒtV O2max) and 36.4 ¡Ó 8.5 and 35.4 ¡Ó 10.9 (%), respectively. A paired-samples T-test revealed a significant difference in FATmax (g.min-1) between the tests (t = 2.65, P = 0.03). The mean difference in FATmax was 0.05 (g.min-1) with the 95% confidence interval ranging from 0.01 to 0.18. Paired-samples T-test, however, revealed no significant difference in the workloads (i.e. W) between the tests, t (9) = 0.70, P = 0.4. The intra-class correlation coefficient for FATmax (g.min-1) between the tests was 0.84 (95% confidence interval: 0.36-0.96, P < 0.01). However, Bland-Altman analysis revealed a large disagreement in FATmax (g.min-1) related to W between the two tests; 11 ¡Ó 14 (W) (4.1 ¡Ó 5.3 ƒtV O2peak (%)).These data demonstrate two important phenomena associated with exercise-induced substrate oxidation; firstly, that maximal fat oxidation derived from a discontinuous FATmax protocol differed statistically between repeated tests, and secondly, there was large variability in the workload corresponding with FATmax. The second aim of Study 2 was to test the validity of a DISCON-FATmax protocol by comparing maximal fat oxidation (g.min-1) determined by DISCON-FATmax with fat oxidation (g.min-1) during a continuous exercise protocol using a constant load (CONEX). Ten overweight and obese sedentary males (BMI = 29.5 ¡Ó 4.5 kg/m2; age = 28.0 ¡Ó 4.5 y) with a ƒtV O2max of 29.1 ¡Ó 7.5 ml.kg-1.min-1 performed a DISCON-FATmax test consisting of alternate 4-min exercise and 2-min rest intervals on a cycle ergometer. The 1-h CONEX protocol used the workload from the DISCON-FATmax to determine FATmax. The mean FATmax, ƒtV O2max, %ƒtV O2max and workload at which FATmax occurred during the DISCON-FATmax were 0.23 ¡Ó 0.09 (g.min-1); 29.1 ¡Ó 7.5 (ml.kg-1.min-1); 43.8 ¡Ó 7.3 (%ƒtV O2max) and 58.8 ¡Ó 19.6 (W), respectively. The mean fat oxidation during the 1-h CONEX protocol was 0.19 ¡Ó 0.07 (g.min-1). A paired-samples T-test revealed no significant difference in fat oxidation (g.min-1) between DISCON-FATmax and CONEX, t (9) = 1.85, P = 0.097 (two-tailed). There was also no significant correlation in fat oxidation between the DISCON-FATmax and CONEX (R=0.51, P = 0.14). Bland- Altman analysis revealed a large disagreement in fat oxidation between the DISCONFATmax and CONEX; the upper limit of agreement was 0.13 (g.min-1) and the lower limit of agreement was ¡V0.03 (g.min-1). These data suggest that the CONEX and DISCONFATmax protocols did not elicit different rates of fat oxidation (g.min-1). However, the individual variability in fat oxidation was large, particularly in the DISCON-FATmax test. Further research is needed to ascertain the validity of graded exercise tests for predicting fat oxidation during constant load exercise sessions. The aim of Study 3 was to compare the impact of two different intensities of four weeks of exercise training on fat oxidation, NEAT, and appetite in overweight and obese men. Using a cross-over design 11 participants (BMI = 29 ¡Ó 4 kg/m2; age = 27 ¡Ó 4 y) participated in a training study and were randomly assigned initially to: [1] a lowintensity (45%ƒtV O2max) exercise (LIT) or [2] a high-intensity interval (alternate 30 s at 90%ƒtV O2max followed by 30 s rest) exercise (HIIT) 40-min duration, three times a week. Participants completed four weeks of supervised training and between cross-over had a two week washout period. At baseline and the end of each exercise intervention,ƒtV O2max, fat oxidation, and NEAT were measured. Fat oxidation was determined during a standard 30-min continuous exercise bout at 45%ƒtV O2max. During the steady state exercise expired gases were measured intermittently for 5-min periods and HR was monitored continuously. In each training period, NEAT was measured for seven consecutive days using an accelerometer (RT3) the week before, at week 3 and the week after training. Subjective appetite sensations and food preferences were measured immediately before and after the first exercise session every week for four weeks during both LIT and HIIT. The mean fat oxidation rate during the standard continuous exercise bout at baseline for both LIT and HIIT was 0.14 ¡Ó 0.08 (g.min-1). After four weeks of exercise training, the mean fat oxidation was 0.178 ¡Ó 0.04 and 0.183 ¡Ó 0.04 g.min-1 for LIT and HIIT, respectively. The mean NEAT (counts.min-1) was 45 ¡Ó 18 at baseline, 55 ¡Ó 22 and 44 ¡Ó 16 during training, and 51 ¡Ó 14 and 50 ¡Ó 21 after training for LIT and HIIT, respectively. There was no significant difference in fat oxidation between LIT and HIIT. Moreover, although not statistically significant, there was some evidence to suggest that LIT and HIIT tend to increase fat oxidation during exercise at 45% ƒtV O2max (P = 0.14 and 0.08, respectively). The order of training treatment did not significantly influence changes in fat oxidation, NEAT, and appetite. NEAT (counts.min-1) was not significantly different in the week following training for either LIT or HIIT. Although not statistically significant (P = 0.08), NEAT was 20% lower during week 3 of exercise training in HIIT compared with LIT. Examination of appetite sensations revealed differences in the intensity of hunger, with higher ratings after LIT compared with HIIT. No differences were found in preferences for high-fat sweet foods between LIT and HIIT. In conclusion, the results of this thesis suggest that while fat oxidation during steady state exercise was not affected by the level of exercise intensity, there is strong evidence to suggest that intense exercise could have a debilitative effect on NEAT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contact lenses are a common method for the correction of refractive errors of the eye. While there have been significant advancements in contact lens designs and materials over the past few decades, the lenses still represent a foreign object in the ocular environment and may lead to physiological as well as mechanical effects on the eye. When contact lenses are placed in the eye, the ocular anatomical structures behind and in front of the lenses are directly affected. This thesis presents a series of experiments that investigate the mechanical and physiological effects of the short-term use of contact lenses on anterior and posterior corneal topography, corneal thickness, the eyelids, tarsal conjunctiva and tear film surface quality. The experimental paradigm used in these studies was a repeated measures, cross-over study design where subjects wore various types of contact lenses on different days and the lenses were varied in one or more key parameters (e.g. material or design). Both, old and newer lens materials were investigated, soft and rigid lenses were used, high and low oxygen permeability materials were tested, toric and spherical lens designs were examined, high and low powers and small and large diameter lenses were used in the studies. To establish the natural variability in the ocular measurements used in the studies, each experiment also contained at least one “baseline” day where an identical measurement protocol was followed, with no contact lenses worn. In this way, changes associated with contact lens wear were considered in relation to those changes that occurred naturally during the 8 hour period of the experiment. In the first study, the regional distribution and magnitude of change in corneal thickness and topography was investigated in the anterior and posterior cornea after short-term use of soft contact lenses in 12 young adults using the Pentacam. Four different types of contact lenses (Silicone hydrogel/ Spherical/–3D, Silicone Hydrogel/Spherical/–7D, Silicone Hydrogel/Toric/–3D and HEMA/Toric/–3D) of different materials, designs and powers were worn for 8 hours each, on 4 different days. The natural diurnal changes in corneal thickness and curvature were measured on two separate days before any contact lens wear. Significant diurnal changes in corneal thickness and curvature within the duration of the study were observed and these were taken into consideration for calculating the contact lens induced corneal changes. Corneal thickness changed significantly with lens wear and the greatest corneal swelling was seen with the hydrogel (HEMA) toric lens with a noticeable regional swelling of the cornea beneath the stabilization zones, the thickest regions of the lenses. The anterior corneal surface generally showed a slight flattening with lens wear. All contact lenses resulted in central posterior corneal steepening, which correlated with the relative degree of corneal swelling. The corneal swelling induced by the silicone hydrogel contact lenses was typically less than the natural diurnal thinning of the cornea over this same period (i.e. net thinning). This highlights why it is important to consider the natural diurnal variations in corneal thickness observed from morning to afternoon to accurately interpret contact lens induced corneal swelling. In the second experiment, the relative influence of lenses of different rigidity (polymethyl methacrylate – PMMA, rigid gas permeable – RGP and silicone hydrogel – SiHy) and diameters (9.5, 10.5 and 14.0) on corneal thickness, topography, refractive power and wavefront error were investigated. Four different types of contact lenses (PMMA/9.5, RGP/9.5, RGP/10.5, SiHy/14.0), were worn by 14 young healthy adults for a period of 8 hours on 4 different days. There was a clear association between fluorescein fitting pattern characteristics (i.e. regions of minimum clearance in the fluorescein pattern) and the resulting corneal shape changes. PMMA lenses resulted in significant corneal swelling (more in the centre than periphery) along with anterior corneal steepening and posterior flattening. RGP lenses, on the other hand, caused less corneal swelling (more in the periphery than centre) along with opposite effects on corneal curvature, anterior corneal flattening and posterior steepening. RGP lenses also resulted in a clinically and statistically significant decrease in corneal refractive power (ranging from 0.99 to 0.01 D), large enough to affect vision and require adjustment in the lens power. Wavefront analysis also showed a significant increase in higher order aberrations after PMMA lens wear, which may partly explain previous reports of "spectacle blur" following PMMA lens wear. We further explored corneal curvature, thickness and refractive changes with back surface toric and spherical RGP lenses in a group of 6 subjects with toric corneas. The lenses were worn for 8 hours and measurements were taken before and after lens wear, as in previous experiments. Both lens types caused anterior corneal flattening and a decrease in corneal refractive power but the changes were greater with the spherical lens. The spherical lens also caused a significant decrease in WTR astigmatism (WRT astigmatism defined as major axis within 30 degrees of horizontal). Both the lenses caused slight posterior corneal steepening and corneal swelling, with a greater effect in the periphery compared to the central cornea. Eyelid position, lid-wiper and tarsal conjunctival staining were also measured in Experiment 2 after short-term use of the rigid and SiHy contact lenses. Digital photos of the external eyes were captured for lid position analysis. The lid-wiper region of the marginal conjunctiva was stained using fluorescein and lissamine green dyes and digital photos were graded by an independent masked observer. A grading scale was developed in order to describe the tarsal conjunctival staining. A significant decrease in the palpebral aperture height (blepharoptosis) was found after wearing of PMMA/9.5 and RGP/10.5 lenses. All three rigid contact lenses caused a significant increase in lid-wiper and tarsal staining after 8 hours of lens wear. There was also a significant diurnal increase in tarsal staining, even without contact lens wear. These findings highlight the need for better contact lens edge design to minimise the interactions between the lid and contact lens edge during blinking and more lubricious contact lens surfaces to reduce ocular surface micro-trauma due to friction and for. Tear film surface quality (TFSQ) was measured using a high-speed videokeratoscopy technique in Experiment 2. TFSQ was worse with all the lenses compared to baseline (PMMA/9.5, RGP/9.5, RGP/10.5, and SiHy/14) in the afternoon (after 8 hours) during normal and suppressed blinking conditions. The reduction in TFSQ was similar with all the contact lenses used, irrespective of their material and diameter. An unusual pattern of change in TFSQ in suppressed blinking conditions was also found. The TFSQ with contact lens was found to decrease until a certain time after which it improved to a value even better than the bare eye. This is likely to be due to the tear film drying completely over the surface of the contact lenses. The findings of this study also show that there is still a scope for improvement in contact lens materials in terms of better wettability and hydrophilicity in order to improve TFSQ and patient comfort. These experiments showed that a variety of changes can occur in the anterior eye as a result of the short-term use of a range of commonly used contact lens types. The greatest corneal changes occurred with lenses manufactured from older HEMA and PMMA lens materials, whereas modern SiHy and rigid gas permeable materials caused more subtle changes in corneal shape and thickness. All lenses caused signs of micro-trauma to the eyelid wiper and palpebral conjunctiva, although rigid lenses appeared to cause more significant changes. Tear film surface quality was also significantly reduced with all types of contact lenses. These short-term changes in the anterior eye are potential markers for further long term changes and the relative differences between lens types that we have identified provide an indication of areas of contact lens design and manufacture that warrant further development.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To examine the risk factors for Mycobacterium tuberculosis infection (MTI) among Greenlandic children for the purpose of identifying those at highest risk of infection. Methods Between 2005 and 2007, 1797 Greenlandic schoolchildren in five different areas were tested for MTI with an interferon gamma release assay (IGRA) and a tuberculin skin test (TST). Parents or guardians were surveyed using a standardized self-administered questionnaire to obtain data on crowding in the household, parents’ educational level and the child’s health status. Demographic data for each child – i.e. parents’ place of birth, number of siblings, distance between siblings (next younger and next older), birth order and mother’s age when the child was born – were also extracted from a public registry. Logistic regression was used to check for associations between these variables and MTI, and all results were expressed as odds ratios (ORs) and 95% confidence intervals (CIs). Children were considered to have MTI if they tested positive on both the IGRA assay and the TST. Findings The overall prevalence of MTI was 8.5% (152/1797). MTI was diagnosed in 26.7% of the children with a known TB contact, as opposed to 6.4% of the children without such contact. Overall, the MTI rate was higher among Inuit children (OR: 4.22; 95% CI: 1.55–11.5) and among children born less than one year after the birth of the next older sibling (OR: 2.48; 95% CI: 1.33–4.63). Self-reported TB contact modified the profile to include household crowding and low mother’s education. Children who had an older MTI-positive sibling were much more likely to test positive for MTI themselves (OR: 14.2; 95% CI: 5.75–35.0) than children without an infected older sibling. Conclusion Ethnicity, sibling relations, number of household residents and maternal level of education are factors associated with the risk of TB infection among children in Greenland. The strong household clustering of MTI suggests that family sources of exposure are important.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the effect of eye muscle area (EMA), ossification, carcass weight, marbling and rib fat depth on the incidence of dark cutting (pH u > 5.7) using routinely collected Meat Standards Australia (MSA) data. Data was obtained from 204,072 carcasses at a Western Australian processor between 2002 and 2008. Binomial data of pH u compliance was analysed using a logit model in a Bayesian framework. Increasing eye muscle area from 40 to 80 cm 2, increased pH u compliance by around 14% (P < 0.001) in carcasses less than 350 kg. As carcass weight increased from 150 kg to 220 kg, compliance increased by 13% (P < 0.001) and younger cattle with lower ossification were also 7% more compliant (P < 0.001). As rib fat depth increased from 0 to 20 mm, pH u compliance increased by around 10% (P < 0.001) yet marbling had no effect on dark cutting. Increasing musculature and growth combined with good nutrition will minimise dark cutting beef in Australia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The temporal variations in CO2, CH4 and N2O fluxes were measured over two consecutive years from February 2007 to March 2009 from a subtropical rainforest in south-eastern Queensland, Australia, using an automated sampling system. A concurrent study using an additional 30 manual chambers examined the spatial variability of emissions distributed across three nearby remnant rainforest sites with similar vegetation and climatic conditions. Interannual variation in fluxes of all gases over the 2 years was minimal, despite large discrepancies in rainfall, whereas a pronounced seasonal variation could only be observed for CO2 fluxes. High infiltration, drainage and subsequent high soil aeration under the rainforest limited N2O loss while promoting substantial CH4 uptake. The average annual N2O loss of 0.5 ± 0.1 kg N2O-N ha−1 over the 2-year measurement period was at the lower end of reported fluxes from rainforest soils. The rainforest soil functioned as a sink for atmospheric CH4 throughout the entire 2-year period, despite periods of substantial rainfall. A clear linear correlation between soil moisture and CH4 uptake was found. Rates of uptake ranged from greater than 15 g CH4-C ha−1 day−1 during extended dry periods to less than 2–5 g CH4-C ha−1 day−1 when soil water content was high. The calculated annual CH4 uptake at the site was 3.65 kg CH4-C ha−1 yr−1. This is amongst the highest reported for rainforest systems, reiterating the ability of aerated subtropical rainforests to act as substantial sinks of CH4. The spatial study showed N2O fluxes almost eight times higher, and CH4 uptake reduced by over one-third, as clay content of the rainforest soil increased from 12% to more than 23%. This demonstrates that for some rainforest ecosystems, soil texture and related water infiltration and drainage capacity constraints may play a more important role in controlling fluxes than either vegetation or seasonal variability

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Silicone hydrogel contact lenses (CLs) are becoming increasingly popular for daily wear (DW), extended wear (EW) and continuous wear (CW), due to their higher oxygen transmissibility compared to hydrogel CLs. The aim of this study was to investigate the clinical and subjective performance of asmofilcon A (Menicon Co., Ltd), a new surface treated silicone hydrogel CL, during 6-night EW over 6 months (M). Methods: A prospective, randomised, single-masked, monadic study was conducted. N=60 experienced DW soft CL wearers were randomly assigned to wear either asmofilcon A (test: Dk=129, water content (WC)=40%, Nanogloss surface treatment) or senofilcon A (control: Dk=103, WC=38%, PVP internal wetting agent, Vistakon, Johnson & Johnson Vision Care) CLs bilaterally for 6 M on an EW basis. A PHMB-preserved solution (Menicon Co., Ltd) was dispensed for CL care. Evaluations were conducted at CL delivery and after 1 week (W), 4 W, 3 M and 6 M of EW. At each visit, a range of objective and subjective clinical performance measures were assessed. Results: N=50 subjects (83%) successfully completed the study, with the majority of discontinuations due to loss to follow-up (n=3) or moving away/travel (n=5). N=2 subjects experienced adverse events; n=1 unilateral red eye with asmofilcon A and n=1 asymptomatic infiltrate with senofilcon A. There were no significant differences in high or low contrast distance visual acuity (HCDVA or LCDVA) between asmofilcon A and senofilcon A; however, LCDVA decreased significantly over time with both CL types (p<0.05). The two CL types did not vary significantly with respect to any of the objective and subjective measures assessed (p>0.05); CL fitting characteristics and CL surface measurements were very similar and mean bulbar and limbal redness measures were always less than grade 1.0. Superior palpebral conjunctival injection showed a statistically, but not clinically, significant increase over time with both CL types (p<0.05). Corneal staining did not vary significantly between asmofilcon A and senofilcon A (p>0.05), with low median gradings of less than 0.5 observed for all areas assessed. There were no solution-related staining reactions observed with either CL type. The asmofilcon A and senofilcon A CLs were both rated highly with respect to overall comfort, with medians of 14 or 15 hours of comfortable lens wearing time per day reported at each of the study visits (p>0.05). Conclusions: Over 6 months of EW, the asmofilcon A and senofilcon A CLs performed in a similar manner with respect to visual acuity, ocular health and CL performance measures. Some changes over time were observed with both CL types, including reduced LCDVA and increased superior palpebral injection, which warrant further investigation in longer-term EW studies. Asmofilcon A appeared to be equivalent in performance to senofilcon A.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visual adaptation regulates contrast sensitivity during dynamically changing light conditions (Crawford, 1947; Hecht, Haig & Chase, 1937). These adaptation dynamics are unknown under dim (mesopic) light levels when the rod (R) and long (L), medium (M) and short (S) wavelength cone photoreceptor classes contribute to vision via interactions in shared non-opponent Magnocellular (MC), chromatically opponent Parvocellular (PC) and Koniocellular (KC) visual pathways (Dacey, 2000). This study investigated the time-course of adaptation and post-receptoral pathways mediating receptor specific rod and cone interactions under mesopic illumination. A four-primary photostimulator (Pokorny, Smithson & Quinlan, 2004) was used to independently control the activity of the four photoreceptor classes and their post-receptoral visual athways in human observers. In the first experiment, the contrast sensitivity and time-course of visual adaptation under mesopic illumination were measured for receptoral (L, S, R) and post-receptoral (LMS, LMSR, L-M) stimuli. An incremental (Rapid-ON) sawtooth conditioning pulse biased detection to ON-cells within the visual pathways and sensitivity was assayed relative to pulse onset using a briefly presented incremental probe that did not alter adaptation. Cone.Cone interactions with luminance stimuli (L cone, LMS, LMSR) reduced sensitivity by 15% and the time course of recovery was 25± 5ms-1 (μ ± SEM). PC mediated (+L-M) chromatic stimuli sensitivity loss was less (8%) than for luminance and recovery was slower (μ = 2.95 ± 0.05 ms-1), with KC mediated (S cone) chromatic stimuli showing a high sensitivity loss (38%) and the slowest recovery time (1.6 ± 0.2 ms-1). Rod-Rod interactions increased sensitivity by 20% and the time course of recovery was 0.7 ± 0.2 ms-1 (μ ± SD). Compared to these interaction types, Rod-Cone interactions reduced sensitivity to a lesser degree (5%) and showed the fastest recovery (μ = 43 ± 7 ms-1). In the second experiment, rod contribution to the magnocellular, parvocellular and koniocellular post-receptoral pathways under mesopic illumination was determined as a function of incremental stimulus duration and waveform (rectangular; sawtooth) using a rod colour match procedure (Cao, Pokorny & Smith, 2005; Cao, Pokorny, Smith & Zele, 2008a). For a 30% rod increment, a cone match required a decrease in [L/(L+M)] and an increase in [L+M] and [S/(L+M)], giving a greenish-blue and brighter appearance for probe durations of 75 ms or longer. Probe durations less than 75 ms showed an increase in [L+M] and no change in chromaticity [L/(L+M) or S/(L+M)], uggesting mediation by the MC pathway only for short duration rod stimuli. s We advance previous studies by determining the time-course and nature of photoreceptor specific retinal interactions in the three post-receptoral pathways under mesopic illumination. In the first experiment, the time-course of adaptation for ON cell processing was determined, revealing opponent cell facilitation in chromatic PC and KC pathways. The Rod-Rod and Rod-Cone data identify previously unknown interaction types that act to maintain contrast sensitivity during dynamically changing light conditions and improve the speed of light adaptation under mesopic light levels. The second experiment determined the degree of rod contribution to the inferred post-eceptoral pathways as a function of the temporal properties of the rod signal. r The understanding of the mechanisms underlying interactions between photoreceptors under mesopic illumination has implications for the study of retinal disease. Visual function has been shown to be reduced in persons with age-related maculopathy (ARM) risk genotypes prior to clinical signs of the disease (Feigl, Cao, Morris & Zele, 2011) and disturbances in rod-mediated adaptation have been shown in early phases of ARM (Dimitrov, Guymer, Zele, Anderson & Vingrys, 2008; Feigl, Brown, Lovie-Kitchin & Swann, 2005). Also, the understanding of retinal networks controlling vision enables the development of international lighting standards to optimise visual performance nder dim light levels (e.g. work-place environments, transportation).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to investigate the effect of very small air gaps (less than 1 mm) on the dosimetry of small photon fields used for stereotactic treatments. Measurements were performed with optically stimulated luminescent dosimeters (OSLDs) for 6 MV photons on a Varian 21iX linear accelerator with a Brainlab μMLC attachment for square field sizes down to 6 mm × 6 mm. Monte Carlo simulations were performed using EGSnrc C++ user code cavity. It was found that the Monte Carlo model used in this study accurately simulated the OSLD measurements on the linear accelerator. For the 6 mm field size, the 0.5 mm air gap upstream to the active area of the OSLD caused a 5.3 % dose reduction relative to a Monte Carlo simulation with no air gap. A hypothetical 0.2 mm air gap caused a dose reduction > 2 %, emphasizing the fact that even the tiniest air gaps can cause a large reduction in measured dose. The negligible effect on an 18 mm field size illustrated that the electronic disequilibrium caused by such small air gaps only affects the dosimetry of the very small fields. When performing small field dosimetry, care must be taken to avoid any air gaps, as can be often present when inserting detectors into solid phantoms. It is recommended that very small field dosimetry is performed in liquid water. When using small photon fields, sub-millimetre air gaps can also affect patient dosimetry if they cannot be spatially resolved on a CT scan. However the effect on the patient is debatable as the dose reduction caused by a 1 mm air gap, starting out at 19% in the first 0.1 mm behind the air gap, decreases to < 5 % after just 2 mm, and electronic equilibrium is fully re-established after just 5 mm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Potential adverse effects on children health may result from school exposure to airborne particles. To address this issue, measurements in terms of particle number concentration, particle size distribution and black carbon (BC) concentrations were performed in three school buildings in Cassino (Italy) and its suburbs, outside and inside of the classrooms during normal occupancy and use. Additional time resolved information was gathered on ventilation condition, classroom activity, and traffic count data around the schools were obtained using a video camera. Across the three investigated school buildings, the outdoor and indoor particle number concentration monitored down to 4 nm and up to 3 m ranged from 2.8×104 part cm-3 to 4.7×104 part cm-3 and from 2.0×104 part cm-3 to 3.5×104 part cm-3, respectively. The total particle concentrations were usually higher outdoors than indoors, because no indoor sources were detected. I/O measured was less than 1 (varying in a relatively narrow range from 0.63 to 0.74), however one school exhibited indoor concentrations higher than outdoor during the morning rush hours. Particle size distribution at the outdoor site showed high particle concentrations in different size ranges, varying during the day; in relation to the starting and finishing of school time two modes were found. BC concentrations were 5 times higher at the urban school compared with the suburban and suburban-to-urban differences were larger than the relative differences of ultrafine particle concentrations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The onsite treatment of sewage and effluent disposal is widely prevalent in rural and urban fringe areas due to the general unavailability of reticulated wastewater collection systems. Despite the low technology of the systems, failure is common and in many cases leading to adverse public health and environmental consequences. It is important therefore that careful consideration is given to the design and location of onsite sewage treatment systems. This requires an understanding of the factors that influence treatment performance. The use of subsurface absorption systems is the most common form of effluent disposal for onsite sewage treatment, particularly for septic tanks. Also, in the case of septic tanks, a subsurface disposal system is generally an integral component of the sewage treatment process. Site specific factors play a key role in the onsite treatment of sewage. The project The primary aims of the research project were: • to relate treatment performance of onsite sewage treatment systems to soil conditions at site; • to evaluate current research relating to onsite sewage treatment; and, • to identify key issues where currently there is a lack of relevant research. These tasks were undertaken with the objective of facilitating the development of performance based planning and management strategies for onsite sewage treatment. The primary focus of this research project has been on septic tanks. By implication, the investigation has been confined to subsurface soil absorption systems. The design and treatment processes taking place within the septic tank chamber itself did not form a part of the investigation. Five broad categories of soil types prevalent in the Brisbane region have been considered in this project. The number of systems investigated was based on the proportionate area of urban development within the Brisbane region located on each of the different soil types. In the initial phase of the investigation, the majority of the systems evaluated were septic tanks. However, a small number of aerobic wastewater treatment systems (AWTS) were also included. The primary aim was to compare the effluent quality of systems employing different generic treatment processes. It is important to note that the number of each different type of system investigated was relatively small. Consequently, this does not permit a statistical analysis to be undertaken of the results obtained for comparing different systems. This is an important issue considering the large number of soil physico-chemical parameters and landscape factors that can influence treatment performance and their wide variability. The report This report is the last in a series of three reports focussing on the performance evaluation of onsite treatment of sewage. The research project was initiated at the request of the Brisbane City Council. The project component discussed in the current report outlines the detailed soil investigations undertaken at a selected number of sites. In the initial field sampling, a number of soil chemical properties were assessed as indicators to investigate the extent of effluent flow and to help understand what soil factors renovate the applied effluent. The soil profile attributes, especially texture, structure and moisture regime were examined more in an engineering sense to determine the effect of movement of water into and through the soil. It is important to note that it is not only the physical characteristics, but also the chemical characteristics of the soil as well as landscape factors play a key role in the effluent renovation process. In order to understand the complex processes taking place in a subsurface effluent disposal area, influential parameters were identified using soil chemical concepts. Accordingly, the primary focus of this final phase of the research project was to identify linkages between various soil chemical parameters and landscape patterns and their contribution to the effluent renovation process. The research outcomes will contribute to the development of robust criteria for evaluating the performance of subsurface effluent disposal systems. The outcomes The key findings from the soil investigations undertaken are: • Effluent renovation is primarily undertaken by a combination of various soil physico-chemical parameters and landscape factors, thereby making the effluent renovation processes strongly site dependent. • Decisions regarding site suitability for effluent disposal should not be based purely in terms of the soil type. A number of other factors such as the site location in the catena, the drainage characteristics and other physical and chemical characteristics, also exert a strong influence on site suitability. • Sites, which are difficult to characterise in terms of suitability for effluent disposal, will require a detailed soil physical and chemical analysis to be undertaken to a minimum depth of at least 1.2 m. • The Ca:Mg ratio and Exchangeable Sodium Percentage are important parameters in soil suitability assessment. A Ca:Mg ratio of less than 0.5 would generally indicate a high ESP. This in turn would mean that Na and possibly Mg are the dominant exchangeable cations, leading to probable clay dispersion. • A Ca:Mg ratio greater than 0.5 would generally indicate a low ESP in the profile, which in turn indicates increased soil stability. • In higher clay percentage soils, low ESP can have a significant effect. • The presence of high exchangeable Na can be counteracted by the presence of swelling clays, and an exchange complex co-dominated by exchangeable Ca and exchangeable Mg. This aids absorption of cations at depth, thereby reducing the likelihood of dispersion. • Salt is continually added to the soil by the effluent and problems may arise if the added salts accumulate to a concentration that is harmful to the soil structure. Under such conditions, good drainage is essential in order to allow continuous movement of water and salt through the profile. Therefore, for a site to be sustainable, it would have a maximum application rate of effluent. This would be dependent on subsurface characteristics and the surface area available for effluent disposal. • The dosing regime for effluent disposal can play a significant role in the prevention of salt accumulation in the case of poorly draining sites. Though intermittent dosing was not considered satisfactory for the removal of the clogging mat layer, it has positive attributes in the context of removal of accumulated salts in the soil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To measure the thickness at which primary schoolchildren apply sunscreen on school day mornings and to compare it with the thickness (2.00 mg/cm(2)) at which sunscreen is tested during product development, as well as to investigate how application thickness was influenced by age of the child (school grades 1-7) and by dispenser type (500-mL pump, 125-mL squeeze bottle, or 50-mL roll-on). DESIGN: A crossover quasiexperimental study design comparing 3 sunscreen dispenser types. SETTING: Children aged 5 to 12 years from public primary schools (grades 1-7) in Queensland, Australia. PARTICIPANTS: Children (n=87) and their parents randomly recruited from the enrollment lists of 7 primary schools. Each child provided up to 3 observations (n=258). INTERVENTION: Children applied sunscreen during 3 consecutive school weeks (Monday through Friday) for the first application of the day using a different dispenser each week. MAIN OUTCOME MEASURE: Thickness of sunscreen application (in milligrams per square centimeter). The dispensers were weighed before and after use to calculate the weight of sunscreen applied. This was divided by the coverage area of application (in square centimeters), which was calculated by multiplying the children's body surface area by the percentage of the body covered with sunscreen. RESULTS: Children applied their sunscreen at a median thickness of 0.48 mg/cm(2). Children applied significantly more sunscreen when using the pump (0.75 mg/cm(2)) and the squeeze bottle (0.57 mg/cm(2)) compared with the roll-on (0.22 mg/cm(2)) (P<.001 for both). CONCLUSIONS: Regardless of age, primary schoolchildren apply sunscreen at substantially less than 1.00 mg/cm(2), similar to what has been observed among adults. Some sunscreen dispensers seem to facilitate thicker application than others.