125 resultados para Fire departments
Resumo:
In the face of Australia’s disaster-prone environment, architects Ian Weir and James Davidson are reconceptualising how our residential buildings might become more resilient to fire, flood and cyclone. With their first-hand experience of natural disasters, James, director of Emergency Architects Australia (EAA), and Ian, one of Australia’s few ‘bushfire architects’, discuss the ways we can design with disaster in mind. Dr Ian Weir is one of Australia’s few ‘bushfire architects’. Exploring a holistic ‘ground up’ approach to bushfire where landscape, building design and habitation patterns are orchestrated to respond to site-specific fire characteristics. Ian’s research is developed through design studio teaching at QUT and through built works in Western Australia’s fire prone forests and heathlands.
Resumo:
In recent times, light gauge steel frame (LSF) wall systems are increasingly used in the building industry. They are usually made of cold-formed and thin-walled steel studs that are fire-protected by two layers of plasterboard on both sides. A composite LSF wall panel system was developed recently, where an insulation layer was used externally between the two plasterboards to improve the fire performance of LSF wall panels. In this research, finite element thermal models of the new composite panels were developed using a finite element program, SAFIR, to simulate their thermal performance under both standard and Eurocode design fire curves. Suitable apparent thermal properties of both the gypsum plasterboard and insulation materials were proposed and used in the numerical models. The developed models were then validated by comparing their results with available standard fire test results of composite panels. This paper presents the details of the finite element models of composite panels, the thermal analysis results in the form of time-temperature profiles under standard and Eurocode design fire curves and their comparisons with fire test results. Effects of using rockwool, glass fibre and cellulose fibre insulations with varying thickness and density were also investigated, and the results are presented in this paper. The results show that the use of composite panels in LSF wall systems will improve their fire rating, and that Eurocode design fires are likely to cause severe damage to LSF walls than standard fires.
Resumo:
BACKGROUND: A long length of stay (LOS) in the emergency department (ED) associated with overcrowding has been found to adversely affect the quality of ED care. The objective of this study is to determine whether patients who speak a language other than English at home have a longer LOS in EDs compared to those whose speak only English at home. METHODS: A secondary data analysis of a Queensland state-wide hospital EDs dataset (Emergency Department Information System) was conducted for the period, 1 January 2008 to 31 December 2010. RESULTS: The interpreter requirement was the highest among Vietnamese speakers (23.1%) followed by Chinese (19.8%) and Arabic speakers (18.7%). There were significant differences in the distributions of the departure statuses among the language groups (Chi-squared=3236.88, P<0.001). Compared with English speakers, the Beta coeffi cient for the LOS in the EDs measured in minutes was among Vietnamese, 26.3 (95%CI: 22.1–30.5); Arabic, 10.3 (95%CI: 7.3–13.2); Spanish, 9.4 (95%CI: 7.1–11.7); Chinese, 8.6 (95%CI: 2.6–14.6); Hindi, 4.0 (95%CI: 2.2–5.7); Italian, 3.5 (95%CI: 1.6–5.4); and German, 2.7 (95%CI: 1.0–4.4). The fi nal regression model explained 17% of the variability in LOS. CONCLUSION: There is a close relationship between the language spoken at home and the LOS at EDs, indicating that language could be an important predictor of prolonged LOS in EDs and improving language services might reduce LOS and ease overcrowding in EDs in Queensland's public hospitals.
Resumo:
Fire safety design is important to eliminate the loss of property and lives during fire events. Gypsum plasterboard is widely used as a fire safety material in the building industry all over the world. It contains gypsum (CaSO4.2H2O) and Calcium Carbonate (CaCO3) and most importantly free and chemically bound water in its crystal structure. The dehydration of the gypsum and the decomposition of Calcium Carbonate absorb heat, which gives the gypsum plasterboard fire resistant qualities. Currently plasterboard manufacturers use additives such as vermiculite to overcome shrinkage of gypsum core and glass fibre to bridge shrinkage cracks and enhance the integrity of board during calcination and after the loss of paper facings in fires. Past research has also attempted to reduce the thermal conductivity of plasterboards using fillers. However, no research has been undertaken to enhance the specific heat of plasterboard and the points of dehydration using chemical additives and fillers. Hence detailed experimental studies of powdered samples of plasterboard mixed with chemical additives and fillers in varying proportions were conducted. These tests showed the enhancement of specific heat of plasterboard. Numerical models were also developed to investigate the thermal performance of enhanced plasterboards under standard fire conditions. The results showed that the use of these enhanced plasterboards in steel wall systems can significantly improve their fire performance. This paper presents the details of this research and the results that can be used to enhance the fire safety of steel wall systems commonly used in buildings.
Resumo:
Fire safety of light gauge steel frame (LSF) stud walls is important in the design of buildings. Currently LSF walls are increasingly used in the building industry, and are usually made of cold-formed and thin-walled steel studs that are fire-protected by two layers of plasterboard on both sides. Many experimental and numerical studies have been undertaken to investigate the fire performance of load bearing LSF walls under standard fire conditions. However, the standard time-temperature curve does not represent the fire load present in typical residential and commercial buildings that include considerable amount of thermoplastic materials. Real building fires are unlikely to follow a standard time-temperature curve. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under realistic design fire conditions. Therefore in this research, finite element thermal models of the traditional LSF wall panels without cavity insulation and the new LSF composite wall panels were developed to simulate their fire performance under recently developed realistic design fire curves. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and literature review. The developed models were then validated by comparing their thermal performance results with available results from realistic design fire tests, and were later used in parametric studies. This paper presents the details of the developed finite element thermal models of load bearing LSF wall panels under realistic design fire time-temperature curves and the re-sults. It shows that finite element thermal models can be used to predict the fire performance of load bearing LSF walls with varying configurations of insulations and plasterboards under realistic design fires. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses.
Resumo:
There are no population studies of prevalence or incidence of child maltreatment in Australia. Child protection data gives some understanding but is restricted by system capacity and definitional issues across jurisdictions. Child protection data currently suggests that numbers of reports are increasing yearly, and the child protection system then becomes focussed on investigating all reports and diluting available resources for those children who are most in need of intervention. A public health response across multiple agencies enables responses to child safety across the entire population. All families are targeted at the primary level; examples include ensuring all parents know the dangers of shaking a baby or teaching children to say no if a situation makes them uncomfortable. The secondary level of prevention targets families with a number of risk factors, for example subsidised child care so children aren't left unsupervised after school when both parents have to be at work or home visiting for drug-addicted parents to ensure children are cared for. The tertiary response then becomes the responsibility of the child protection system and is reserved for those children where abuse and neglect are identified. This model requires that child safety is seen in a broader context than just the child protection system, and increasingly health professionals are being identified as an important component in the public health framework. If all injury is viewed as preventable and considered along a continuum of 'accidental' through to 'inflicted', it becomes possible to conceptualise child maltreatment in an injury context. Parental intent may not be to cause harm to the child, but by lack of insight or concern about risk, the potential for injury is high. The mechanisms for unintentional and intentional injury overlap and some suggest that by segregating child abuse (with the possible exception of sexual abuse) from unintentional injury, child abuse is excluded from the broader injury prevention initiative that is gaining momentum in the community. This research uses a public health perspective, specifically that of injury prevention, to consider the problem of child abuse. This study employed a mixed method design that incorporates secondary data analysis, data linkage and structured interviews of different professional groups. Datasets from the Queensland Injury Surveillance Unit (QISU) and The Department of Child Safety (DCS) were evaluated. Coded injury data was grouped according to intent of injury according to those with a code that indicated the ED presentation was due to child abuse, a code indicating that the injury was possibly due to abuse or, in the third group, the intent code indicated that the injury was unintentional and not due to abuse. Primary data collection from ED records was undertaken and information recoded to assess reliability and completeness. Emergency department data (QISU) was linked to Department of Child Safety Data to examine concordance and data quality. Factors influencing the collection and collation of these data were identified through structured interview methodology and analysed using qualitative methods. Secondary analysis of QISU data indicated that codes lacking specific information on the injury event were more likely to also have an intent code indicating abuse than those records where there was specific information on the injury event. Codes for abuse appeared in only 1.2% of the 84,765 records analysed. Unintentional injury was the most commonly coded intent (95.3%). In the group with a definite abuse code assigned at triage, 83% linked to a record with DCS and cases where documentation indicated police involvement were significantly more likely to be associated with a DCS record than those without such documentation. In those coded with an unintentional injury code, 22% linked to a DCS record with cases assigned an urgent triage category more likely to link than those with a triage category for resuscitation and children who presented to regional or remote hospitals more likely to link to a DCS record than those presenting to urban hospitals. Twenty-nine per cent of cases with a code indicating possible abuse linked to a DCS record. In documentation that indicated police involvement in the case, a code for unspecified activity when compared to cases with a code indicating involvement in a sporting activity and children less than 12 months of age compared to those in the 13-17 year old age group were all variables significantly associated with linkage to a DCS record. Only 13% of records contained documentation indicating that child abuse and neglect were considered in the diagnosis of the injury despite almost half of the sample having a code of abuse or possible abuse. Doctors and nurses were confident in their knowledge of the process of reporting child maltreatment but less confident about identifying child abuse and neglect and what should be reported. Many were concerned about implications of reporting, for the child and family and for themselves. A number were concerned about the implications of not reporting, mostly for the wellbeing of the child and a few in terms of their legal obligations as mandatory reporters. The outcomes of this research will help improve the knowledge of barriers to effective surveillance of child abuse in emergency departments. This will, in turn, ensure better identification and reporting practises; more reliable official statistical collections and the potential of flagging high-risk cases to ensure adequate departmental responses have been initiated.
Resumo:
Load bearing Light Gauge Steel Frame (LSF) walls made of cold-formed steel studs and tracks are commonly used in residential and commercial buildings. Fire safety of these walls is essential to minimize the damage caused by fire related accidents. Past investigations on the fire performance of load bearing LSF wall systems have been limited to LSF walls made of conventional lipped channel section studs. Although structurally efficient hollow flange steel sections are available in the building industry, they are not used as LSF wall studs due to the lack of fire performance data for such walls. The hollow flange sections have torsionally rigid hollow flanges that eliminate the occurrence of local and distortional buckling to an extent, thereby increasing their structural efficiency. The weaknesses of hollow flange sections such as lower lateral distortional buckling capacity are also eliminated when they are used as studs of LSF walls as the plasterboard restraints will prevent any lateral movement. Therefore hollow flange sections can be considered as structurally more efficient studs for use in LSF wall systems. This paper reports the full scale fire tests of LSF walls made of hollow flange section studs under standard fire conditions. The frames were made of 1.6 mm thick and 150 mm deep hollow flange section studs with two closed rectangular flanges of 45 mm width x 15 mm depth. Dual plasterboards were attached on both sides of the test wall panels. The load ratio was varied and the failure times, the lateral deflections and the axial displacements of the test walls were obtained. The failure behaviour of LSF walls made of hollow flange section studs was found to be different to that of LSF walls made of conventional lipped channel section studs. The results of these fire tests show that hollow flange section studs have a higher potential in being used in load bearing LSF Walls.
Resumo:
Cold-formed steel lipped channels are commonly used in LSF wall construction as load bearing studs with plasterboards on both sides. Under fire conditions, cold-formed thin-walled steel sections heat up quickly resulting in fast reduction in their strength and stiffness. Usually the LSF wall panels are subjected to fire from one side which will cause thermal bowing, neutral axis shift and magnification effects due to the development of non-uniform temperature distributions across the stud. This will induce an additional bending moment in the stud and hence the studs in LSF wall panels should be designed as a beam column considering both the applied axial compression load and the additional bending moment. Traditionally the fire resistance rating of these wall panels is based on approximate prescriptive methods. Very often they are limited to standard wall configurations used by the industry. Therefore a detailed research study is needed to develop fire design rules to predict the failure load and hence the failure time of LSF wall panels subject to non-uniform temperature distributions. This paper presents the details of an investigation to develop suitable fire design rules for LSF wall studs under non-uniform elevated temperature distributions. Applications of the previously developed fire design rules based on AISI design manual and Eurocode 3 Parts 1.2 and 1.3 to LSF wall studs were investigated in detail and new simplified fire design rules based on AS/NZS 4600 and Eurocode 3 Part 1.3 were proposed in the current study with suitable allowances for the interaction effects of compression and bending actions. The accuracy of the proposed fire design rules was verified by using the results from full scale fire tests and extensive numerical studies.
Resumo:
Light Gauge Steel Framing (LSF) walls made of cold-formed and thin-walled steel lipped channel studs with plasterboard linings on both sides are commonly used in commercial, industrial and residential buildings. However, there is limited data about their structural and thermal performance under fire conditions while past research showed contradicting results about the benefits of using cavity insulation. A new composite wall panel was recently proposed to improve the fire resistance rating of LSF walls, where an insulation layer was used externally between the plasterboards on both sides of the wall frame instead of using it in the cavity. In this research 11 full scale tests were conducted on conventional load bearing steel stud walls with and without cavity insulation, and the new composite panel system to study their thermal and structural performance under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls, and provided supporting research data. They demonstrated that the use of insulation externally in a composite panel enhanced the thermal and structural performance of LSF walls and increased their fire resistance rating. This paper presents the details of the LSF wall tests and the thermal and structural performance data and fire resistance rating of load-bearing wall assemblies lined with varying plasterboard-insulation configurations under two different load ratios. Fire test results including the time–temperature and deflection profiles are presented along with the failure times and modes.
Resumo:
Light Gauge Steel Framing (LSF) walls are made of cold-formed, thin-walled steel lipped channel studs with plasterboard linings on both sides. However, these thin-walled steel sections heat up quickly and lose their strength under fire conditions despite the protection provided by plasterboards. A new composite wall panel was recently proposed to improve the fire resistance rating of LSF walls, where an insulation layer was used externally between the plasterboards on both sides of the wall frame instead of using it in the cavity. A research study using both fire tests and numerical studies was undertaken to investigate the structural and thermal behaviour of load bearing LSF walls made of both conventional and the new composite panels under standard fire conditions and to determine their fire resistance rating. This paper presents the details of finite element models of LSF wall studs developed to simulate the structural performance of LSF wall panels under standard fire conditions. Finite element analyses were conducted under both steady and transient state conditions using the time-temperature profiles measured during the fire tests. The developed models were validated using the fire test results of 11 LSF wall panels with various plasterboard/insulation configurations and load ratios. They were able to predict the fire resistance rating within five minutes. The use of accurate numerical models allowed the inclusion of various complex structural and thermal effects such as local buckling, thermal bowing and neutral axis shift that occurred in thin-walled steel studs under non-uniform elevated temperature conditions. Finite element analyses also demonstrated the improvements offered by the new composite panel system over the conventional cavity insulated system.
Resumo:
Light gauge steel frame wall systems are commonly used in industrial and commercial buildings, and there is a need for simple fire design rules to predict their load capacities and fire resistance ratings. During fire events, the light gauge steel frame wall studs are subjected to non-uniform temperature distributions that cause thermal bowing, neutral axis shift and magnification effects and thus resulting in a combined axial compression and bending action on the studs. In this research, a series of full-scale fire tests was conducted first to evaluate the performance of light gauge steel frame wall systems with eight different wall configurations under standard fire conditions. Finite element models of light gauge steel frame walls were then developed, analysed under transient and steady-state conditions and validated using full-scale fire tests. Using the results from fire tests and finite element analyses, a detailed investigation was undertaken into the prediction of axial compression strength and failure times of light gauge steel frame wall studs in standard fires using the available fire design rules based on Australian, American and European standards. The results from both fire tests and finite element analyses were used to investigate the ability of these fire design rules to include the complex effects of non-uniform temperature distributions and their accuracy in predicting the axial compression strength of wall studs and the failure times. Suitable modifications were then proposed to the fire design rules. This article presents the details of this investigation on the fire design rules of light gauge steel frame walls and the results.
Resumo:
Traditionally the fire resistance rating of LSF wall systems is based on approximate prescriptive methods developed using limited fire tests. Therefore a detailed research study into the performance of load bearing LSF wall systems under standard fire conditions was undertaken to develop improved fire design rules. It used the extensive fire performance results of eight different LSF wall systems from a series of full scale fire tests and numerical studies for this purpose. The use of previous fire design rules developed for LSF walls subjected to non-uniform elevated temperature distributions based on AISI design manual and Eurocode3 Parts 1.2 and 1.3 was investigated first. New simplified fire design rules based on AS/NZS 4600, North American Specification and Eurocode 3 Part 1.3 were then proposed in this study with suitable allowances for the interaction effects of compression and bending actions. The importance of considering thermal bowing, magnified thermal bowing and neutral axis shift in the fire design was also investigated. A spread sheet based design tool was developed based on the new design rules to predict the failure load ratio versus time and temperature curves for varying LSF wall configurations. The accuracy of the proposed design rules was verified using the test and FEA results for different wall configurations, steel grades, thicknesses and load ratios. This paper presents the details and results of this study including the improved fire design rules for predicting the load capacity of LSF wall studs and the failure times of LSF walls under standard fire conditions.
Resumo:
Recent fire research into the behaviour of light gauge steel frame (LSF) wall systems has devel-oped fire design rules based on Australian and European cold-formed steel design standards, AS/NZS 4600 and Eurocode 3 Part 1.3. However, these design rules are complex since the LSF wall studs are subjected to non-uniform elevated temperature distributions when the walls are exposed to fire from one side. Therefore this paper proposes an alternative design method for routine predictions of fire resistance rating of LSF walls. In this method, suitable equations are recommended first to predict the idealised stud time-temperature pro-files of eight different LSF wall configurations subject to standard fire conditions based on full scale fire test results. A new set of equations was then proposed to find the critical hot flange (failure) temperature for a giv-en load ratio for the same LSF wall configurations with varying steel grades and thickness. These equations were developed based on detailed finite element analyses that predicted the axial compression capacities and failure times of LSF wall studs subject to non-uniform temperature distributions with varying steel grades and thicknesses. This paper proposes a simple design method in which the two sets of equations developed for time-temperature profiles and critical hot flange temperatures are used to find the failure times of LSF walls. The proposed method was verified by comparing its predictions with the results from full scale fire tests and finite element analyses. This paper presents the details of this study including the finite element models of LSF wall studs, the results from relevant fire tests and finite element analyses, and the proposed equations.
Resumo:
Cold–formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design of buildings. A composite LSF wall panel system was developed recently, where a thin insulation was sandwiched between two plasterboards to improve the fire performance of LSF walls. Many experimental and numerical studies have been undertaken to investigate the fire performance of non-load bearing LSF wall under standard conditions. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under standard and realistic design fire conditions. Therefore in this research, finite element thermal models of both the conventional load bearing LSF wall panels with cavity insulation and the innovative LSF composite wall panel were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and available literature. The developed models were then validated by comparing their results with available fire test results of load bearing LSF wall. This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results. It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses. Finite element analysis results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection to them. Effects of realistic design fire conditions are also presented in this paper.
Resumo:
BACKGROUND: Public hospital EDs in Australia have become increasingly congested because of increasing demand and access block. Six per cent of ED patients attend private hospital EDs whereas 45% of the population hold private health insurance. OBJECTIVES: This study describes the patients attending a small selection of four private hospital EDs in Queensland and Victoria, and tests the feasibility of a private ED database. METHODS: De-identified routinely collected patient data were provided by the four participating private hospital and amalgamated into a single data set. RESULT: The mean age of private ED patients was 52 years. Males outnumbered females in all age groups except > 80 years. Attendance was higher on weekends and Mondays, and between 08.00 and 20.00 h. There were 6.6% of the patients triaged as categories 1 and 2, and 60% were categories 4 or 5. There were 36.4% that required hospital admission. Also, 96% of the patients had some kind of insurance. Furthermore, 72% were self-referred and 12% were referred by private medical practitioners. Approximately 25% arrived by ambulance. There were 69% that completed their ED treatment within 4 h. CONCLUSION: This study is the first public description of patients attending private EDs in Australia. Private EDs have a significant role to play in acute medical care and in providing access to private hospitals which could alleviate pressure on public EDs. This study demonstrates the need for consolidated data based on a consistent data set and data dictionary to enable system-wide analysis, benchmarking and evaluation