320 resultados para Axial skeleton
Resumo:
The time course of elongation and recovery of axial length associated with a 30 minute accommodative task was studied using optical low coherence reflectometry in a population of young adult myopic (n = 37) and emmetropic (n = 22) subjects. Ten of the 59 subjects were excluded from analysis either due to inconsistent accommodative response, or incomplete anterior biometry data. Those subjects with valid data (n = 49) were found to exhibit a significant axial elongation immediately following the commencement of a 30 minute, 4 D accommodation task, which was sustained for the duration of the task, and ¬was evident to a lesser extent immediately following task cessation. During the accommodation task, on average, the myopic subjects exhibited 22 ± 34 µm, and the emmetropic subjects 6 ± 22 µm of axial elongation, however the differences in axial elongation between the myopic and emmetropic subjects were not statistically significant (p = 0.136). Immediately following the completion of the task, the myopic subjects still exhibited an axial elongation (mean magnitude 12 ± 28 µm), that was significantly greater (p < 0.05) than the changes in axial length observed in the emmetropic subjects (mean change -3 ± 16 µm). Axial length had returned to baseline levels 10 minutes after completion of the accommodation task. The time for recovery from accommodation-induced axial elongation was greater in myopes, which may reflect differences in the biomechanical properties of the globe associated with refractive error. Changes in subfoveal choroidal thickness were able to be measured in 37 of the 59 subjects, and a small amount of choroidal thinning was observed during the accommodation task that was statistically significant in the myopic subjects (p < 0.05). These subfoveal choroidal changes could account for some but not all of the increased axial length during accommodation.
Resumo:
Purpose. The purpose of the study was to investigate the changes in axial length occurring with shifts in gaze direction. Methods. Axial length measurements were obtained from the left eye of 30 young adults (10 emmetropes, 10 low myopes, and 10 moderate myopes) through a rotating prism with 15° deviation, along the foveal axis, using a noncontact optical biometer in each of the nine different cardinal directions of gaze over 5 minutes. The subject's fellow eye fixated on an external distance (6 m) target to control accommodation, also with 15° deviation. Axial length measurements were also performed in 15° and 25° downward gaze with the biometer inclined on a tilting table, allowing gaze shifts to be achieved with either full head turn but no eye turn, or full eye turn with no head turn. Results. There was a significant influence of gaze angle and time on axial length (both P < 0.001), with the greatest axial elongation (+18 ± 8 μm) occurring with inferonasal gaze (P < 0.001) and a slight decrease in axial length in superior gaze (−12 ± 17 μm) compared with primary gaze (P < 0.001). In downward gaze, a significant axial elongation occurred when eye turn was used (P < 0.001), but not when head turn was used to shift gaze (P > 0.05). Conclusions. The angle of gaze has a small but significant short-term effect on axial length, with greatest elongation occurring in inferonasal gaze. The elongation of the eye appears to be due to the influence of the extraocular muscles, in particular the oblique muscles.
Resumo:
Recent research indicates that brief periods (60 minutes) of monocular defocus lead to small but significant changes in human axial length. However, the effects of longer periods of defocus on the axial length of human eyes are unknown. We examined the influence of a 12 hour period of monocular myopic defocus on the natural daily variations occurring in axial length and choroidal thickness of young adult emmetropes. A series of axial length and choroidal thickness measurements (collected at ~3 hourly intervals, with the first measurement at ~9 am and the final measurement at ~9 pm) were obtained for 13 emmetropic young adults over three consecutive days. The natural daily rhythms (Day 1, baseline day, no defocus), the daily rhythms with monocular myopic defocus (Day 2, defocus day, +1.50 DS spectacle lens over the right eye), and the recovery from any defocus induced changes (Day 3, recovery day, no defocus) were all examined. Significant variations over the course of the day were observed in both axial length and choroidal thickness on each of the three measurement days (p<0.0001). The magnitude and timing of the daily variations in axial length and choroidal thickness were significantly altered with the monocular myopic defocus on day 2 (p<0.0001). Following the introduction of monocular myopic defocus, the daily peak in axial length occurred approximately 6 hours later, and the peak in choroidal thickness approximately 8.5 hours earlier in the day compared to days 1 and 3 (with no defocus). The mean amplitude (peak to trough) of change in axial length (0.030 ± 0.012 on day 1, 0.020 ± 0.010 on day 2 and 0.033 ± 0.012 mm on day 3) and choroidal thickness (0.030 ± 0.007 on day 1, 0.022 ± 0.006 on day 2 and 0.027 ± 0.009 mm on day 3) were also significantly different between the three days (both p<0.05). The introduction of monocular myopic defocus disrupts the daily variations in axial length and choroidal thickness of human eyes (in terms of both amplitude and timing) that return to normal the following day after removal of the defocus.
Resumo:
The residence time distribution (RTD) is a crucial parameter when treating engine exhaust emissions with a Dielectric Barrier Discharge (DBD) reactor. In this paper, the residence time of such a reactor is investigated using a finite element based software: COMSOL Multiphysics 4.3. Non-thermal plasma (NTP) discharge is being introduced as a promising method for pollutant emission reduction. DBD is one of the most advantageous of NTP technologies. In a two cylinder co-axial DBD reactor, tubes are placed between two electrodes and flow passes through the annuals between these barrier tubes. If the mean residence time increases in a DBD reactor, there will be a corresponding increase in reaction time and consequently, the pollutant removal efficiency can increase. However, pollutant formation can occur during increased mean residence time and so the proportion of fluid that may remain for periods significantly longer than the mean residence time is of great importance. In this study, first, the residence time distribution is calculated based on the standard reactor used by the authors for ultrafine particle (10-500 nm) removal. Then, different geometrics and various inlet velocities are considered. Finally, for selected cases, some roughness elements added inside the reactor and the residence time is calculated. These results will form the basis for a COMSOL plasma and CFD module investigation.
Resumo:
The first fiber Bragg grating (FBG) accelerometer using direct transverse forces is demonstrated by fixing the FBG by its two ends and placing a transversely moving inertial object at its middle. It is very sensitive because a lightly stretched FBG is more sensitive to transverse forces than axial forces. Its resonant frequency and static sensitivity are analyzed by the classic spring-mass theory, assuming the axial force changes little. The experiments show that the theory can be modified for cases where the assumption does not hold. The resonant frequency can be modified by a linear relationship experimentally achieved, and the static sensitivity by an alternative method proposed. The principles of the over-range protection and low cross axial sensitivity are achieved by limiting the movement of the FBG and were validated experimentally. The sensitivities 1.333 and 0.634 nm/g were experimentally achieved by 5.29 and 2.83 gram inertial objects at 10 Hz from 0.1 to 0.4 g (g = 9.8 m/s 2), respectively, and their resonant frequencies were around 25 Hz. Their theoretical static sensitivities and resonant frequencies found by the modifications are 1.188 nm/g and 26.81 Hz for the 5.29 gram one and 0.784 nm/g and 29.04 Hz for the 2.83 gram one, respectively.
Resumo:
This paper describes a study of the theoretical and experimental behaviour of box-columns of varying b/t ratios under loadings of axial compression and torsion and their combinations. Details of the testing rigs and the testing methods, the results obtained such as the load-deflection curves and the interaction diagrams, and experimental observations regarding the behaviour of box-models and the types of local plastic mechanisms associated with each type of loading are presented. A simplified rigid-plastic analysis is carried out to study the collapse behaviour of box-columns under these loadings, based on the observed plastic mechanisms, and the results are compared with those of experiments.
Resumo:
Purpose To investigate the influence of monocular hyperopic defocus on the normal diurnal rhythms in axial length and choroidal thickness of young adults. Methods A series of axial length and choroidal thickness measurements (collected at ~3 hourly intervals, with the first measurement at ~9 am and the final measurement at ~9 pm) were obtained for 15 emmetropic young adults over three consecutive days. The natural diurnal rhythms (Day 1, no defocus), diurnal rhythms with monocular hyperopic defocus (Day 2, – 2.00 DS spectacle lens over the right eye), and the recovery from any defocus induced changes (Day 3, no defocus) in diurnal rhythms were examined. Results Both axial length and choroidal thickness underwent significant diurnal changes on each of the three measurement days (p<0.0001). The introduction of monocular hyperopic defocus resulted in significant changes in the diurnal variations observed in both parameters (p<0.05). A significant (p<0.001) increase in the mean amplitude (peak to trough) of change in axial length (mean increase, 0.016 ± 0.005 mm) and choroidal thickness (mean increase, 0.011 ± 0.003 mm) was observed on day 2 with hyperopic defocus compared to the two ‘no defocus’ days (days 1 and 3). At the second measurement (mean time 12:10 pm) on the day with hyperopic defocus, the eye was significantly longer by 0.012 ± 0.002 mm compared to the other two days (p<0.05). No significant difference was observed in the average timing of the daily peaks in axial length (mean peak time 12:12 pm) and choroidal thickness (21:02 pm) over the three days. Conclusions The introduction of monocular hyperopic defocus resulted in a significant increase in the amplitude of the diurnal change in axial length and choroidal thickness that returned to normal the following day after removal of the blur stimulus.
Resumo:
Material yielding is typically modeled either by plastic zone or plastic hinge methods under the context of geometric and material nonlinear finite element methods. In fire analysis of steel structures, the plastic zone method is widely used, but it requires extensively more computational efforts. The objective of this paper is to develop the nonlinear material model allowing for interaction of both axial force and bending moment, which relies on the plastic hinge method to achieve numerical efficiency and reduce computational effort. The biggest advantage of the plastic-hinge approach is its computational efficiency and easy verification by the design code formulae of the axial force–moment interaction yield criterion for beam–column members. Further, the method is reliable and robust when used in analysis of practical and large structures. In order to allow for the effect of catenary action, axial thermal expansion is considered in the axial restraint equations. The yield function for material yielding incorporated in the stiffness formulation, which allows for both axial force and bending moment effects, is more accurate and rational to predict the behaviour of the frames under fire. In the present fire analysis, the mechanical properties at elevated temperatures follow mainly the Eurocode 3 [Design of steel structures, Part 1.2: Structural fire design. European Committee for Standisation; 2003]. Example of a tension member at a steady state heating condition is modeled to verify the proposed spring formulation and to compare with results by others. The behaviour of a heated member in a highly redundant structure is also studied by the present approach.
Resumo:
This paper focuses on the use of externally bonded Carbon Fiber Reinforced Polymer (CFRP) materials to strengthen steel plates subjected to compression. A fully slender steel section was selected in this test programme. CFRP strengthened steel plates and non strengthened plates were tested to fail under compressive load. The middle part of the strut was strengthened using CFRP sheet. The length of the strengthened zone was varied. Eight specimens were tested in this test programme. The test results showed a significant strength gain of 47% and delaying of lateral torsional buckling failure mode of strengthened members. This study confirms that there is great potential to increase the short term performance of CFRP strengthened steel structure under axial compression.
Resumo:
Purpose: To investigate the changes occurring in the axial length, choroidal thickness and anterior biometrics of the eye during a 10 minute near task performed in downward gaze. Methods: Twenty young adult subjects (10 emmetropes and 10 myopes) participated in this study. To measure ocular biometrics in downward gaze, an optical biometer was inclined on a custom built, height and tilt adjustable table. Baseline measures were collected after each subject performed a distance primary gaze control task for 10 mins, to provide wash-out period for prior visual tasks before each of three different accommodation/gaze conditions. These other three conditions included a near task (2.5 D) in primary gaze, and a near (2.5 D) and a far (0 D) accommodative task in downward gaze (25°), all for 10 mins duration. Immediately after, and then 5 and 10 mins from the commencement of each trial, measurements of ocular biometrics (e.g. anterior biometrics, axial length, choroidal thickness and retinal thickness) were obtained. Results: Axial length increased with accommodation and was significantly greater for downward gaze with accommodation (mean change ± SD 23 ± 13 µm at 10 mins) compared to primary gaze with accommodation (mean change 8 ± 15 µm at 10 mins) (p < 0.05). A small amount of choroidal thinning was also found during accommodation that was statistically significant in downward gaze (13 ± 14 µm at 10 mins, p < 0.05). Accommodation in downward gaze also caused greater changes in anterior chamber depth and lens thickness compared to accommodation in primary gaze. Conclusion: Axial length, choroidal thickness and anterior eye biometrics change significantly during accommodation in downward gaze as a function of time. These changes appear to be due to the combined influence of biomechanical factors (i.e. extraocular muscle forces, ciliary muscle contraction) associated with near tasks in downward gaze.
Resumo:
Vibration characteristics of columns are influenced by their axial loads. Numerous methods have been developed to quantify axial load and deformation in individual columns based on their natural frequencies. However, these methods cannot be applied to columns in a structural framing system as the natural frequency is a global parameter of the entire framing system. This paper presents an innovative method to quantify axial deformations of columns in a structural framing system using its vibration characteristics, incorporating the influence of load tributary areas, boundary conditions and load migration among the columns.
Resumo:
Purpose: To investigate the changes in axial length with the combined effect of accommodation and angle of gaze (convergence and downward gaze) over 5 minutes in groups of myopes and emmetropes. Methods: A total of 31 subjects (nine emmetropes, 10 low myopes, and 12 moderate to high myopes) aged from 18 to 31 years were recruited. To measure ocular biometrics in inferonasal gaze with accommodation, an optical biometer (Lenstar LS900) was inclined on a tilt and height adjustable stage, with the subject’s chinrest mounted on a rotary stage to induce various levels of convergence by rotation of the subject’s head in primary or downward gaze. Initially, the subjects performed a distance viewing task in primary gaze for 10 minutes to provide a ‘wash-out’ period for prior visual tasks, and then the subject’s axial length and ocular biometrics were measured in nine different combinations of gaze/accommodation over 5 minutes. These nine sessions for all gaze measurements (i.e. three levels of accommodation 9 three levels of convergence) were completed across 3 days of testing (one accommodation condition on each day).The nine combinations of gaze/accommodation were based on those required to view the centre, right and left edges of a distant TV at 6 m in primary gaze, an intermediate task (i.e. computer at 50 cm in 10° downward gaze) and a near task (i.e. reading A4 page at 20 cm in 20° downward gaze). Subjects were wearing a custom built three-axes head tracker throughout the experiment that monitored subjects’ relative head movements (roll, pitch and yaw) during measurements. Results: A significant increase in axial length occurred with the combined effect of accommodation, convergence and downward gaze (repeated measures ANOVA, p < 0.001), with the greatest axial elongation during the near task in downward gaze with convergence (i.e. downward 20°/inward 33°, with 5 D accommodation) (mean change 33 ± 13 lm, after 5 minutes task) followed by the intermediate task (i.e. downward 10°/inward 25°, with 2 D accommodation) (mean change 14 ± 11 lm, after 5 minutes task).Changes in axial length for the distance task (i.e. primary gaze/9° convergence, with 0.16 D accommodation) were not statistically significant (mean change 4 ± 8 lm, after 5 minutes task, p > 0.05). Moderate to high myopes had a greater change in the axial length (mean change 40 ± 11 lm after 5 minutes of near task) than that of emmetropes (mean change 29 ± 15 lm after 5 minutes of near task) and low myopes (mean change 29 ± 16 lm after 5 minutes of near task) associated with time (p = 0.02) and accommodation by time (p = 0.03). Conclusions: The combination of accommodation, convergence and downward angle has a significant short term effect on axial length over time. The near task in downward gaze with convergence caused a greater change in axial length than the intermediate and distant visual tasks. The greater axial elongation measured in the infero-nasal direction with accommodation is most likely associated with a combination of biomechanical factors such as, extraocular muscle forces and ciliary muscle contraction.
Resumo:
Although accelerometers are extensively used for assessing gait, limited research has evaluated the concurrent validity of these devices on less predictable walking surfaces or the comparability of different methods used for gravitational acceleration compensation. This study evaluated the concurrent validity of trunk accelerations derived from a tri-axial inertial measurement unit while walking on firm, compliant and uneven surfaces and contrasted two methods used to remove gravitational accelerations: i) subtraction of the best linear fit from the data (detrending), and; ii) use of orientation information (quaternions) from the inertial measurement unit. Twelve older and twelve younger adults walked at their preferred speed along firm, compliant and uneven walkways. Accelerations were evaluated for the thoracic spine (T12) using a tri-axial inertial measurement unit and an eleven-camera Vicon system. The findings demonstrated excellent agreement between accelerations derived from the inertial measurement unit and motion analysis system, including while walking on uneven surfaces that better approximate a real-world setting (all differences <0.16 m.s−2). Detrending produced slightly better agreement between the inertial measurement unit and Vicon system on firm surfaces (delta range: −0.05 to 0.06 vs. 0.00 to 0.14 m.s−2), whereas the quaternion method performed better when walking on compliant and uneven walkways (delta range: −0.16 to −0.02 vs. −0.07 to 0.07 m.s−2). The technique used to compensate for gravitational accelerations requires consideration in future research, particularly when walking on compliant and uneven surfaces. These findings demonstrate trunk accelerations can be accurately measured using a wireless inertial measurement unit and are appropriate for research that evaluates healthy populations in complex environments.
Resumo:
This paper presents the modeling and motion-sensorless direct torque and flux control of a novel dual-airgap axial-flux permanent-magnet machine optimized for use in flywheel energy storage system (FESS) applications. Independent closed-loop torque and stator flux regulation are performed in the stator flux ( x-y) reference frame via two PI controllers. This facilitates fast torque dynamics, which is critical as far as energy charging/discharging in the FESS is concerned. As FESS applications demand high-speed operation, a new field-weakening algorithm is proposed in this paper. Flux weakening is achieved autonomously once the y-axis voltage exceeds the available inverter voltage. An inherently speed sensorless stator flux observer immune to stator resistance variations and dc-offset effects is also proposed for accurate flux and speed estimation. The proposed observer eliminates the rotary encoder, which in turn reduces the overall weight and cost of the system while improving its reliability. The effectiveness of the proposed control scheme has been verified by simulations and experiments on a machine prototype.