663 resultados para drug comparison
Resumo:
Estimating the prevalence of drink driving is a difficult task. Self‐reported drink driving indicates that drink driving is far more common than official statistics suggest. In order to promote a responsible attitude towards alcohol consumption and drink driving within the Queensland community, the Queensland Police Service, Queensland Health and Queensland Transport developed the ‘Drink Rite’ program (Queensland Police Service information sheet, 2009). However, the feasibility of the program is now in doubt as the National Health and Medical Research Council’s guidelines for alcohol consumption changed in 2009 to state “For healthy men and women, drinking no more than four standard drinks on a single occasion reduces the risk of alcohol‐related injury arising from that occasion” (NHMRC Publication, 2009, p. 51). As such, adhering to the NHMRC guidelines places restrictions on how the existing Drink Rite program can be operated (i.e. by reducing the number of standard drinks provided to participants from eight to four). It is arguable that a reduction in the number of alcoholic drinks provided to participants in the program will result in a large reduction in observed BAC readings. This, in turn, will lead to a potential loss of message content when discussing the variation in the effects of alcohol.
Resumo:
Multifunctional bioactive materials with the ability to stimulate osteogenesis and angiogenesis of stem cells play an important role in the regeneration of bone defects. However, how to develop such biomaterials remains a significant challenge. In this study, we prepared mesoporous silica nanospheres (MSNs) with uniform sphere size (∼90 nm) and mesopores (∼2.7 nm), which could release silicon ions (Si) to stimulate the osteogenic differentiation of human bone marrow stromal cells (hBMSCs) via activating their ALP activity, bone-related gene and protein (OCN, RUNX2 and OPN) expression. Hypoxia-inducing therapeutic drug, dimethyloxaloylglycine (DMOG), was effectively loaded in the mesopores of MSNs (D-MSNs). The sustained release of DMOG from D-MSNs could stabilize HIF-1α and further stimulated the angiogenic differentiation of hBMSCs as indicated by the enhanced VEGF secretion and protein expression. Our study revealed that D-MSNs could combine the stimulatory effect on both osteogenic and angiogenic activity of hBMSCs. The potential mechanism of D-MSN-stimulated osteogenesis and angiogenesis was further elucidated by the supplementation of cell culture medium with pure Si ions and DMOG. Considering the easy handling characteristics of nanospheres, the prepared D-MSNs may be applied in the forms of injectable spheres for minimally invasive surgery, or MSNs/polymer composite scaffolds for bone defect repair. The concept of delivering both stimulatory ions and functional drugs may offer a new strategy to construct a multifunctional biomaterial system for bone tissue regeneration.
Resumo:
In this paper we excite bound long range stripe plasmon modes with a highly focused laser beam. We demonstrate highly confined plasmons propagating along a 50 μm long silver stripe 750 nm wide and 30 nm thick. Two excitation techniques were studied: focusing the laser spot onto the waveguide end and focusing the laser spot onto a silver grating. By comparing the intensity of the out-coupling photons at the end of the stripe for both grating and end excitation we are able to show that gratings provide an increase of a factor of two in the output intensity and thus out-coupling of plasmons excited by this technique are easier to detect. Authors expect that the outcome of this paper will prove beneficial for the development of passive nano-optical devices based on stripe waveguides, by providing insight into the different excitation techniques available and the advantages of each technique.
Resumo:
Multidrug resistance (MDR) occurs in prostate cancer, and this happens when the cancer cells resist chemotherapeutic drugs by pumping them out of the cells. MDR inhibitors such as cyclosporin A (CsA) can stop the pumping and enhance the drugs accumulated in the cells. The cellular drug accumulation is monitored using a microfluidic chip mounted on a single cell bioanalyzer. This equipment has been developed to measure accumulation of drugs such as doxorubicin (DOX) and fluorescently labeled paclitaxel (PTX) in single prostate cancer cells. The inhibition of drug efflux on the same prostate cell was examined in drug-sensitive and drug-resistant cells. Accumulation of these drug molecules was not found in the MDR cells, PC-3 RX-DT2R cells. Enhanced drug accumulation was observed only after treating the MDR cell in the presence of 5 μM of CsA as the MDR inhibitor. We envision this monitoring of the accumulation of fluorescent molecules (drug or fluorescent molecules), if conducted on single patient cancer cells, can provide information for clinical monitoring of patients undergoing chemotherapy in the future.
Resumo:
Purpose/Objectives: To examine and compare the reliability of four body composition methods commonly used in assessing breast cancer survivors. Design: Cross-sectional. Setting: A rehabilitation facility at a university-based comprehensive cancer center in the southeastern United States. Sample: 14 breast cancer survivors aged 40-71 years. Methods: Body fat (BF) percentage was estimated via bioelectric impedance analysis (BIA), air displacement plethysmography (ADP), and skinfold thickness (SKF) using both three- and seven-site algorithms, where reliability of the methods was evaluated by conducting two tests for each method (test 1 and test 2), one immediately after the other. An analysis of variance was used to compare the results of BF percentage among the four methods. Intraclass correlation coefficient (ICC) was used to test the reliability of each method. Main Research Variable: BF percentage. Findings: Significant differences in BF percentage were observed between BIA and all other methods (three-site SKF, p < 0.001; seven-site SKF, p < 0.001; ADP, p = 0.002). No significant differences (p > 0.05) in BF percentage between three-site SKF, seven-site SKF, and ADP were observed. ICCs between test 1 and test 2 for each method were BIA = 1, ADP = 0.98, three-site SKF = 0.99, and seven-site SKF = 0.94. Conclusions: ADP and both SKF methods produce similar estimates of BF percentage in all participants, whereas BIA overestimated BF percentage relative to the other measures. Caution is recommended when using BIA as the body composition method for breast cancer survivors who have completed treatment but are still undergoing adjuvant hormonal therapy. Implications for Nursing: Measurements of body composition can be implemented very easily as part of usual care and should serve as an objective outcome measure for interventions designed to promote healthy behaviors among breast cancer survivors. - See more at: https://onf.ons.org/onf/38/4/comparison-body-composition-assessment-methods-breast-cancer-survivors#sthash.5djfTS1Q.dpuf
Resumo:
The Wechsler and Stanford Binet scales are among the most commonly used tests of intelligence. In clinical practice, they often seem to be used interchangeably. This paper reports the results of two studies that compared the most recent editions of two Wechsler scales (WPPSI-III and WISC-IV) with the Stanford-Binet Fifth Edition (SB5). The participants in the first study were 36 typically developing 4-year-old children who completed the WPPSI-III and SB5 in counter-balanced order. Although correlations of composite scores ranged from r = .59 to r = .82 and were similar to those reported for earlier versions of the two instruments, more than half the sample had a score discrepancy greater than 10 points across the two instruments. In the second study, the WISC-IV and SB5 were administered to 30 children aged 12-14 years. There was a significant difference between Full Scale IQs on the two measures, with scores being higher on the WISC-IV. Differences between the two verbal scales were also significant and favoured the WISC-IV. There were moderate correlations of Full Scale IQs (r = .58) and Nonverbal IQs (r = .54) but the relationship between the two Verbal scales was not significant. For some children, notable score differences led to different categorisations of their level of intellectual ability The findings suggest that the Wechsler and Stanford Binet scales cannot be presumed to be interchangeable. The discussion focuses on how psychologists might reconcile large differences in test scores and the need for caution when interpreting and comparing test results.
Resumo:
BACKGROUND: An early response to antipsychotic treatment in patients with psychosis has been associated with a better course and outcome. However, factors that predict treatment response are not well understood. The onset of schizophrenia and related disorders has been associated with increased levels of stress and hyper-activation of the hypothalamic-pituitary-adrenal (HPA) axis. This study examined whether pituitary volume at the onset of psychosis may be a potential predictor of early treatment response in first-episode psychosis (FEP) patients. METHODS: We investigated the relationship between baseline pituitary volume and symptomatic treatment response over 12 weeks using mixed model analysis in a sample of 42 drug-naïve or early treated FEP patients who participated in a controlled dose-finding study of quetiapine fumarate. Logistic regression was used to examine predictors of treatment response. Pituitary volume was measured from magnetic resonance imaging scans that were obtained upon entry into the trial. RESULTS: Larger pituitary volume was associated with less improvement in overall psychotic symptoms (Brief Psychiatric Rating Scale (BPRS) P=0.031) and positive symptoms (BPRS positive symptom subscale P=0.010). Regardless of gender, patients with a pituitary volume at the 25th percentile (413 mm(3)) were approximately three times more likely to respond to treatment by week 12 than those at the 75th percentile (635 mm(3)) (odds ratio=3.07, CI: 0.90-10.48). CONCLUSION: The association of baseline pituitary volumes with early treatment response highlights the importance of the HPA axis in emerging psychosis. Potential implications for treatment strategies in early psychosis are discussed.
Resumo:
Marble from the Chillagoe deposits was extensively used in the construction of Australia’s parliament house. Near infrared (NIR) spectroscopy has been applied to study the quality of marble from the Chillagoe marble deposits and to distinguish between different types of marble in the Chillagoe deposits. A comparison of the NIR spectra of marble with dolomite and monohydrocalcite is made. The spectrum of the marble closely resembles that of monohydrocalcite and is different from that of dolomite. The infrared spectra of the minerals are characterised by OH and water stretching vibrations. Both the first and second fundamental overtones of these bands are observed in the NIR spectra. Marble is characterised by NIR bands at 4005, 4268 and 4340 cm–1, attributed to carbonate combination bands and overtones. Marble also shows NIR bands at 5005, 5106, 5234 and 5334 cm–1 assigned to water combination bands. Finally the NIR spectrum of the marble displays broad low-intensity features centred upon 6905 cm–1 attributed to the water first overtones. It appears feasible to identify marble through the use of NIR spectroscopy.
Resumo:
The minerals clinotyrolite and fuxiaotuite are discredited in terms of the mineral tangdanite. The mixed anion mineral tangdanite Ca2Cu9(AsO4)4(SO4)0.5(OH)9 9H2O has been studied using a combination of Raman and infrared spectroscopy. Characteristic bands associated with arsenate, sulphate and hydroxyl units are identified. Broad bands in the OH stretching region are observed and are resolved into component bands. These bands are assigned to water and hydroxyl stretching vibrations. Two intense Raman bands at 837 and approximately 734 cm−1 are assigned to the ν1 (AsO4)3− symmetric stretching and ν3 (AsO4)3− antisymmetric stretching modes. Infrared bands at 1023 cm−1 are assigned to the (SO4)2− ν1 symmetric stretching mode, and infrared bands at 1052, 1110 and 1132 cm−1 assigned to (SO4)2− ν3 antisymmetric stretching modes, confirming the presence of the sulphate anion in the tangdanite structure. Raman bands at 593 and 628 cm−1 are attributed to the (SO4)2− ν4 bending modes. Low-intensity Raman bands found at 457 and 472 cm−1 are assigned to the (AsO4)3− ν2 bending modes. A comparison is made with the previously obtained spectral data on the discredited mineral clinotyrolite.
Resumo:
Purpose The role of fine lactose in the dispersion of salmeterol xinafoate (SX) from lactose mixtures was studied by modifying the fine lactose concentration on the surface of the lactose carriers using wet decantation. Methods Fine lactose was removed from lactose carriers by wet decantation using ethanol saturated with lactose. Particle sizing was achieved by laser diffraction. Fine particle fractions (FPFs) were determined by Twin Stage Impinger using a 2.5% SX mixture, and SX was analyzed by a validated high-performance liquid chromatography method. Adhesion forces between probes of SX and silica and the lactose surfaces were determined by atomic force microscopy. Results FPFs of SX were related to fine lactose concentration in the mixture for inhalation grade lactose samples. Reductions in FPF (2-4-fold) of Aeroflo 95 and 65 were observed after removing fine lactose by wet decantation; FPFs reverted to original values after addition of micronized lactose to decanted mixtures. FPFs of SX of sieved and decanted fractions of Aeroflo carriers were significantly different (p < 0.001). The relationship between FPF and fine lactose concentration was linear. Decanted lactose demonstrated surface modification through increased SX-lactose adhesion forces; however, any surface modification other than removal of fine lactose only slightly influenced FPF. Conclusions Fine lactose played a key and dominating role in controlling FPF. SX to fine lactose ratios influenced dispersion of SX with maximum dispersion occurring as the ratio approached unity.
Resumo:
This study develops and tests a model through a multi-country study that considers consumer wine knowledge and wine experience, wine brand trust and wine brand satisfaction as antecedents of wine brand love, and wine brand loyalty as a consequence of wine brand love. Data were collected in five wine-producing countries (Australia, Chile, France, Mexico and Portugal) with a final sample of 3462 completed surveys. Hypotheses were tested with structural equation modeling and the findings confirm the importance of brand love as both a mediator and direct influence on brand loyalty for wine consumers. Furthermore, brand satisfaction was positively and significantly related to brand love. In addition, wine experience, rather than wine knowledge, positively influenced brand trust and satisfaction. Finally, results also identify differences between countries thereby providing insights into how companies should focus their marketing strategies internationally.
Resumo:
On the basis of the growing interest on the impact of airborne particles on human exposure as well as the strong debate in Western countries on the emissions of waste incinerators, this work reviewed existing literature to: (i) show the emission factors of ultrafine particles (particles with a diameter less than 100 nm) of waste incinerators, and; (ii) assess the contribution of waste incinerators in terms of ultrafine particles to exposure and dose of people living in the surrounding areas of the plants in order to estimate eventual risks. The review identified only a limited number of studies measuring ultrafine particle emissions, and in general they report low particle number concentrations at the stack (the median value was equal to 5.5×103 part cm-3), in most cases higher than the outdoor background value. The lowest emissions were achieved by utilization of the bag-house filter which has an overall number-based filtration efficiency higher than 99%. Referring to reference case, the corresponding emission factor is equal to 9.1×1012 part min-1, that is lower than one single high-duty vehicle. Since the higher particle number concentrations found in the most contributing microenvironments to the exposure (indoor home, transportation, urban outdoor), the contribution of the waste incinerators to the daily dose can be considered as negligible.
Resumo:
Overhead high-voltage power lines are known sources of corona ions. These ions rapidly attach to aerosols to form charged particles in the environment. Although the effect of ions and charged particles on human health is largely unknown, much attention has focused on the increasing exposure as a result of the expanding power network in urban residential areas. However, it is not widely known that a large number of charged particles in urban environments originate from motor vehicle emissions. In this study, for the first time, we compare the concentrations of charged nanoparticles near busy roads and overhead power lines. We show that large concentrations of both positive and negative charged nanoparticles are present near busy roadways and that these concentrations commonly exceed those under high-voltage power lines. We estimate that the concentration of charged nanoparticles found near two freeways carrying around 120 vehicles per minute exceeded the corresponding maximum concentrations under two corona-emitting overhead power lines by as much as a factor of 5. The difference was most pronounced when a significant fraction of traffic consisted of heavy-duty diesel vehicles which typically have high particle and charge emission rates.
Resumo:
Background: The Pharmacy Board of Australia stipulated that for renewal of registration, pharmacists must have accrued a minimum of 20 CPD credits over the 2010-11 registration years (1). Mandatory CPD is not new in Pharmacy. The UK and New Zealand have both established systems of CPD in recent years. The purpose of this study is to investigate established CPD processes in the UK and New Zealand with the view to making recommendations for the implementation of the CPD process in Australia. Objectives: To compare the acquisition and guidance on documentation of CPD credit points in Australia, New Zealand and the United Kingdom. Methodology: A comparative online search of the websites of each of the registering authorities was undertaken. Any practice standards or guidelines which relate to registration or continuing professional development were analysed and compared. Results: In New Zealand the Pharmacy Council require Pharmacists to have a minimum of 12 outcome credits over a 3-year period for recertification (2, 3). The outcome credit related to each CPD action and is based on relevance to the pharmacist and their practice. It is graded between one, for CPD which has occasional relevance to practice and three which have considerable relevance to practice. There are examples of completed CPD recording sheets on their website (8). In the UK, The General Pharmaceutical Council require Pharmacists to make a minimum of nine CPD entries per year (4) and detailed guidance on how to record CPD activities is provided (5,7). The Pharmacy Board of Australia divides CPD activities into three groups (6). Of the 20 credits required annually only 10 can be gained from group one activities, which is information accessed without assessment. There is only brief guidance on the recording of CPD. Discussion: The GPhC in the UK provided the most comprehensive guidance on acquisition of CPD credit points and documentation (5,7) The Pharmacy Council of New Zealand made CPD points relevant to practice.(2,8) The Pharmacy Board of Australia provided limited information for pharmacists on CPD activities, which may impede pharmacist participation. Information may assist in increasing pharmacists’ engagement in CPD activities. In conclusion, there is variation between the three countries in the amount and type of information provided about CPD requirements.
Resumo:
Background Balance dysfunction is one of the most common problems in people who suffer stroke. To parameterize functional tests standardized by inertial sensors have been promoted in applied medicine. The aim of this study was to compare the kinematic variables of the Functional Reach Test (FRT) obtained by two inertial sensors placed on the trunk and lumbar region between stroke survivors (SS) and healthy older adults (HOA) and to analyze the reliability of the kinematic measurements obtained. Methods Cross-sectional study. Five SS and five HOA over 65. A descriptive analysis of the average range as well as all kinematic variables recorded was developed. The intrasubject and intersubject reliability of the measured variables was directly calculated. Results In the same intervals, the angular displacement was greater in the HOA group; however, they were completed at similar times for both groups, and HOA conducted the test at a higher speed and greater acceleration in each of the intervals. The SS values were higher than HOA values in the maximum and minimum acceleration in the trunk and in the lumbar region. Conclusions The SS show less functional reach, a narrower, slower and less accelerated movement during the FRT execution, but with higher peaks of acceleration and speed when they are compared with HOA.