742 resultados para Anthony Munday
Resumo:
The role of the screen producer is ramifying. Not only are there numerous producer categories, but the screen producer function is also found on a continuum across film, television, advertising, corporate video, and the burgeoning digital media sector. In recent years, fundamental changes to distribution and consumption practices and technologies should have had a correlate impact on screen production practices and on the role of existing screen producers. At the same time, new and recent producers are learning and practicing their craft in a field that has already been transformed by digitisation and media convergence. Our analysis of the work, experience and outlook of screen producers in this chapter is based on data collected in the Australian Screen Producer Survey (ASPS), a nation-wide survey conducted by the ARC Centre of Excellence for Creative Industries and Innovation, the media marketing firm Bergent Research, and the Centre for Screen Business at the Australian Film, Television and Radio School (AFTRS) in 2008/09 and 2011. We analyse the results to better understand the practice of screen production in a period of industry transition, and to recognise the persistence of established production cultures that serve to distinguish different industry sectors.
Resumo:
Monitoring stream networks through time provides important ecological information. The sampling design problem is to choose locations where measurements are taken so as to maximise information gathered about physicochemical and biological variables on the stream network. This paper uses a pseudo-Bayesian approach, averaging a utility function over a prior distribution, in finding a design which maximizes the average utility. We use models for correlations of observations on the stream network that are based on stream network distances and described by moving average error models. Utility functions used reflect the needs of the experimenter, such as prediction of location values or estimation of parameters. We propose an algorithmic approach to design with the mean utility of a design estimated using Monte Carlo techniques and an exchange algorithm to search for optimal sampling designs. In particular we focus on the problem of finding an optimal design from a set of fixed designs and finding an optimal subset of a given set of sampling locations. As there are many different variables to measure, such as chemical, physical and biological measurements at each location, designs are derived from models based on different types of response variables: continuous, counts and proportions. We apply the methodology to a synthetic example and the Lake Eacham stream network on the Atherton Tablelands in Queensland, Australia. We show that the optimal designs depend very much on the choice of utility function, varying from space filling to clustered designs and mixtures of these, but given the utility function, designs are relatively robust to the type of response variable.
Resumo:
This paper describes a new method of indexing and searching large binary signature collections to efficiently find similar signatures, addressing the scalability problem in signature search. Signatures offer efficient computation with acceptable measure of similarity in numerous applications. However, performing a complete search with a given search argument (a signature) requires a Hamming distance calculation against every signature in the collection. This quickly becomes excessive when dealing with large collections, presenting issues of scalability that limit their applicability. Our method efficiently finds similar signatures in very large collections, trading memory use and precision for greatly improved search speed. Experimental results demonstrate that our approach is capable of finding a set of nearest signatures to a given search argument with a high degree of speed and fidelity.
Resumo:
Human lymphatic vascular malformations (LMs), also known as cystic hygromas or lymphangioma, consist of multiple lymphatic endothelial cell-lined lymph-containing cysts. No animal model of this disease exists. To develop a mouse xenograft model of human LM, CD34NegCD31Pos LM lymphatic endothelial cells (LM-LEC) were isolated from surgical specimens and compared to foreskin CD34NegCD31Pos lymphatic endothelial cells (LECs). Cells were implanted into a mouse tissue engineering model for 1, 2 and 4 weeks. In vitro LM-LECs showed increased proliferation and survival under starvation conditions (P < 0.0005 at 48 h, two-way ANOVA), increased migration (P < 0.001, two-way ANOVA) and formed fewer (P = 0.029, independent samples t test), shorter tubes (P = 0.029, independent samples t test) than foreskin LECs. In vivo LM-LECs implanted into a Matrigel™-containing mouse chamber model assembled to develop vessels with dilated cystic lumens lined with flat endothelium, morphology similar to that of clinical LMs. Human foreskin LECs failed to survive implantation. In LM-LEC implanted chambers the percent volume of podoplaninPos vessels was 1.18 ± 2.24 % at 1 week, 6.34 ± 2.68 % at 2 weeks and increasing to 7.67 ± 3.60 % at 4 weeks. In conclusion, the significantly increased proliferation, migration, resistance to apoptosis and decreased tubulogenesis of LM-LECs observed in vitro is likely to account for their survival and assembly into stable LM-like structures when implanted into a mouse vascularised chamber model. This in vivo xenograft model will provide the basis of future studies of LM biology and testing of potential pharmacological interventions for patients with lymphatic malformations.
Resumo:
As Drs Patel and McGhee intimate, the original nerve mapping technique they described 1 was tedious and time-consuming, requiring the capture of hundreds of separate images and many hours of manual montaging to form a confluent map. The maps they published also had distracting component image delineation. It is for these reasons that a number of research groups have sought to develop automated techniques for generating these nerve maps (Table 1).2–6...
Resumo:
The report of this subcommittee concerns the impact of contact lenses (CLs) on the ocular surface, with a particular emphasis on CL discomfort (CLD). We define the ocular surface, its regional anatomy, and the physiological responses of each region to CL wear.
Resumo:
Aims Corneal nerve morphology and corneal sensation threshold have recently been explored as potential surrogate markers for the evaluation of diabetic neuropathy. We present the baseline findings of the ‘Longitudinal Assessment of Neuropathy in type 1 Diabetes using novel ophthalmic Markers’(LANDMark) study. Methods The LANDMark study is a 4-year, two-site, natural history study of three participant groups: type 1 diabetes with neuropathy (T1W), type 1 diabetes without neuropathy (T1WO) and control participants without diabetes or neuropathy. All participants undergo a detailed annual assessment of neuropathy including corneal nerve parameters measured using corneal confocal microscopy and corneal sensitivity measured using non-contact corneal aesthesiometry. Results 76 T1W, 166 T1WO and 154 control participants were enrolled into the study. Corneal sensation threshold (mbars) was significantly higher (i.e. sensitivity was lower) in T1W (1.0 ± 1.1) than T1WO (0.7 ± 0.7) and controls (0.6 ± 0.4) (p < 0.001), with no difference between T1WO and controls. Corneal nerve fibre length was lower in T1W (14.0 ± 6.4 mm/mm2) compared to T1WO (19.1 ± 5.8 mm/mm2) and controls (23.2 ± 6.3 mm/mm2) (p < 0.001). Corneal nerve fibre length was lower in T1WO compared to controls. Conclusions The LANDMark baseline findings confirm a reduction in corneal sensitivity only in Type 1 patients with neuropathy. However, corneal nerve fibre length is reduced even in Type 1 patients without neuropathy with an even greater deficit in Type 1 patients with neuropathy.
Resumo:
AIMS: Recent studies on corneal markers have advocated corneal nerve fibre length as the most important measure of diabetic peripheral neuropathy. The aim of this study was to determine if standardizing corneal nerve fibre length for tortuosity increases its association with other measures of diabetic peripheral neuropathy. METHODS: Two hundred and thirty-one individuals with diabetes with either predominantly mild or absent neuropathic changes and 61 control subjects underwent evaluation of diabetic neuropathy symptom score, neuropathy disability score, testing with 10-g monofilament, quantitative sensory testing (warm, cold, vibration detection) and nerve conduction studies. Corneal nerve fibre length and corneal nerve fibre tortuosity were measured using corneal confocal microscopy. A tortuosity-standardised corneal nerve fibre length variable was generated by dividing corneal nerve fibre length by corneal nerve fibre tortuosity. Differences in corneal nerve morphology between individuals with and without diabetic peripheral neuropathy and control subjects were determined and associations were estimated between corneal morphology and established tests of, and risk factors for, diabetic peripheral neuropathy. RESULTS: The tortuosity-standardised corneal nerve fibre length variable was better than corneal nerve fibre length in demonstrating differences between individuals with diabetes, with and without neuropathy (tortuosity-standardised corneal nerve fibre length variable: 70.5 ± 27.3 vs. 84.9 ± 28.7, P < 0.001, receiver operating characteristic area under the curve = 0.67; corneal nerve fibre length: 15.9 ± 6.9 vs. 18.4 ± 6.2 mm/mm(2) , P = 0.004, receiver operating characteristic area under the curve = 0.64). Furthermore, the tortuosity-standardised corneal nerve fibre length variable demonstrated a significant difference between the control subjects and individuals with diabetes, without neuropathy, while corneal nerve fibre length did not (tortuosity-standardised corneal nerve fibre length variable: 94.3 ± 27.1 vs. 84.9 ± 28.7, P = 0.028; corneal nerve fibre length: 20.1 ± 6.3 vs. 18.4 ± 6.2 mm/mm(2) , P = 0.084). Correlations between corneal nerve fibre length and established measures of neuropathy and risk factors for neuropathy were higher when a correction was made for the nerve tortuosity. CONCLUSIONS: Standardizing corneal nerve fibre length for tortuosity enhances the ability to differentiate individuals with diabetes, with and without neuropathy.
Resumo:
TCNQ·− radical anions (TCNQ = 7,7,8,8,-tetracyanoquinodimethane) form a wide range of semiconducting coordination polymers when coordinated to transition metals. Some such as CuTCNQ and AgTCNQ exhibit molecular switching and memory storage properties; others have intriguing magnetic properties and for example may behave as molecular magnets at low temperature. In this review, the electro- and photo-chemical synthesis and characterization of this important class of material is reviewed. In particular, the electrochemistry and the redox properties of TCNQ derivatives of coordination polymers based on Cu, Ag, Mn, Fe, Co, Ni, Zn and Cd transition metals are surveyed, with an emphasis on the mechanistic aspects of their electrochemical formation via nucleation–growth processes. Given that TCNQ is an extremely good electron acceptor, readily forming TCNQ•− and TCNQ2-, electrochemical reduction of TCNQ in the presence of a transition metal ion provides an ideal method for synthesis of metal-TCNQ materials by electrocrystallization from organic solvents and ionic liquids or solid-solid transformation using TCNQ modified electrodes from aqueous media containing transition metal electrolytes. The significance of the reversible formal potential (E0f) in these studies is discussed. The coupling of electrocrystallisation on electrode surfaces and microscopic characterization of the electrodeposited materials reveals a wide range of morphologies and phases which strongly influence their properties and applications. Since TCNQ also can be photo-reduced in the presence of suitable electron donors, analogous photochemical approaches to the synthesis of TCNQ-transition metal derivatives are available. The advantages of electrochemical and photochemical methods of synthesis relative to chemical synthesis are outlined.
Resumo:
Bladder cancer is associated with high recurrence and mortality rates due to metastasis. The elucidation of metastasis suppressors may offer therapeutic opportunities if their mechanisms of action can be elucidated and tractably exploited. In this study, we investigated the clinical and functional significance of the transcription factor activating transcription factor 3 (ATF3) in bladder cancer metastasis. Gene expression analysis revealed that decreased ATF3 was associated with bladder cancer progression and reduced survival of patients with bladder cancer. Correspondingly, ATF3 overexpression in highly metastatic bladder cancer cells decreased migration in vitro and experimental metastasis in vivo. Conversely, ATF3 silencing increased the migration of bladder cancer cells with limited metastatic capability in the absence of any effect on proliferation. In keeping with their increased motility, metastatic bladder cancer cells had increased numbers of actin filaments. Moreover, ATF3 expression correlated with expression of the actin filament severing protein gelsolin (GSN). Mechanistic studies revealed that ATF3 upregulated GSN, whereas ATF3 silencing reduced GSN levels, concomitant with alterations in the actin cytoskeleton. We identified six ATF3 regulatory elements in the first intron of the GSN gene confirmed by chromatin immunoprecipitation analysis. Critically, GSN expression reversed the metastatic capacity of bladder cancer cells with diminished levels of ATF3. Taken together, our results indicate that ATF3 suppresses metastasis of bladder cancer cells, at least in part through the upregulation of GSN-mediated actin remodeling. These findings suggest ATF3 coupled with GSN as prognostic markers for bladder cancer metastasis.
Resumo:
Importance Approximately one-third of patients with peripheral artery disease experience intermittent claudication, with consequent loss of quality of life. Objective To determine the efficacy of ramipril for improving walking ability, patient-perceived walking performance, and quality of life in patients with claudication. Design, Setting, and Patients Randomized, double-blind, placebo-controlled trial conducted among 212 patients with peripheral artery disease (mean age, 65.5 [SD, 6.2] years), initiated in May 2008 and completed in August 2011 and conducted at 3 hospitals in Australia. Intervention Patients were randomized to receive 10 mg/d of ramipril (n = 106) or matching placebo (n = 106) for 24 weeks. Main Outcome Measures Maximum and pain-free walking times were recorded during a standard treadmill test. The Walking Impairment Questionnaire (WIQ) and Short-Form 36 Health Survey (SF-36) were used to assess walking ability and quality of life, respectively. Results At 6 months, relative to placebo, ramipril was associated with a 75-second (95% CI, 60-89 seconds) increase in mean pain-free walking time (P < .001) and a 255-second (95% CI, 215-295 seconds) increase in maximum walking time (P < .001). Relative to placebo, ramipril improved the WIQ median distance score by 13.8 (Hodges-Lehmann 95% CI, 12.2-15.5), speed score by 13.3 (95% CI, 11.9-15.2), and stair climbing score by 25.2 (95% CI, 25.1-29.4) (P < .001 for all). The overall SF-36 median Physical Component Summary score improved by 8.2 (Hodges-Lehmann 95% CI, 3.6-11.4; P = .02) in the ramipril group relative to placebo. Ramipril did not affect the overall SF-36 median Mental Component Summary score. Conclusions and Relevance Among patients with intermittent claudication, 24-week treatment with ramipril resulted in significant increases in pain-free and maximum treadmill walking times compared with placebo. This was associated with a significant increase in the physical functioning component of the SF-36 score. Trial Registration clinicaltrials.gov Identifier: NCT00681226
Resumo:
Electrocatalytic processes will undoubtedly be at the heart of energising future transportation and technology with the added importance of being able to create the necessary fuels required to do so in an environmentally friendly and cost effective manner. For this to be successful two almost mutually exclusive surface properties need to be reconciled, namely producing highly active/reactive surface sites that exhibit long term stability. This article reviews the various approaches which have been undertaken to study the elusive nature of these active sites on metal surfaces which are considered as adatoms or clusters of adatoms with low coordination number. This includes the pioneering studies at extended well defined stepped single crystal surfaces using cyclic voltammetry up to the highly sophisticated in situ electrochemical imaging techniques used to study chemically synthesised nanomaterials. By combining the information attained from single crystal surfaces, individual nanoparticles of defined size and shape, density functional theory calculations and new concepts such as mesoporous multimetallic thin films and single atom electrocatalysts new insights into the design and fabrication of materials with highly active but stable active sites can be achieved. The area of electrocatalysis is therefore not only a fascinating and exciting field in terms of realistic technological and economical benefits but also from the fundamental understanding that can be acquired by studying such an array of interesting materials.
Resumo:
Small-scale pumps will be the heartbeat of many future micro/nanoscale platforms. However, the integration of small-scale pumps is presently hampered by limited flow rate with respect to the input power, and their rather complicated fabrication processes. These issues arise as many conventional pumping effects require intricate moving elements. Here, we demonstrate a system that we call the liquid metal enabled pump, for driving a range of liquids without mechanical moving parts, upon the application of modest electric field. This pump incorporates a droplet of liquid metal, which induces liquid flow at high flow rates, yet with exceptionally low power consumption by electrowetting/deelectrowetting at the metal surface. We present theory explaining this pumping mechanism and show that the operation is fundamentally different from other existing pumps. The presented liquid metal enabled pump is both efficient and simple, and thus has the potential to fundamentally advance the field of microfluidics.
Resumo:
Purpose To investigate the application of retinal nerve fibre layer (RNFL) thickness as a marker for severity of diabetic peripheral neuropathy (DPN) in people with Type 2 diabetes. Methods This was a cross-sectional study whereby 61 participants (mean age 61 [41-75 years], mean duration of diabetes 14 [1-40 years], 70% male) with Type 2 diabetes and DPN underwent optical coherence tomography (OCT) scans. Global and 4 quadrant (TSNI) RNFL thicknesses were measured at 3.45mm around the optic nerve head of one eye. Neuropathy disability score (NDS) was used to assess the severity of DPN on a 0 to 10 scale. Participants were divided into three age-matched groups representing mild (NDS=3-5), moderate (NDS=6-8) and severe (NDS=9-10) neuropathy. Two regression models were fitted for statistical analysis: 1) NDS scores as co-variate for global and quadrant RNFL thicknesses, 2) NDS groups as a factor for global RNFL thickness only. Results Mean (SD) RNFL thickness (µm) was 103(9) for mild neuropathy (n=34), 101(10) for moderate neuropathy (n=16) and 95(13) in the group with severe neuropathy (n=11). Global RNFL thickness and NDS scores were statistically significantly related (b=-1.20, p=0.048). When neuropathy was assessed across groups, a trend of thinner mean RNFL thickness was observed with increasing severity of neuropathy; however, this result was not statistically significant (F=2.86, p=0.065). TSNI quadrant analysis showed that mean RNFL thickness reduction in the inferior quadrant was 2.55 µm per 1 unit increase in NDS score (p=0.005). However, the regression coefficients were not statistically significant for RNFL thickness in the superior (b=-1.0, p=0.271), temporal (b=-0.90, p=0.238) and nasal (b=-0.99, p=0.205) quadrants. Conclusions RNFL thickness was reduced with increasing severity of DPN and the effect was most evident in the inferior quadrant. Measuring RNFL thickness using OCT may prove to be a useful, non-invasive technique for identifying severity of DPN and may also provide additional insight into common mechanisms for peripheral neuropathy and RNFL damage.