169 resultados para intraocular lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim was to document contact lens prescribing trends in Australia between 2000 and 2009. ---------- Methods: A survey of contact lens prescribing trends was conducted each year between 2000 and 2009. Australian optometrists were asked to provide information relating to 10 consecutive contact lens fittings between January and March each year. ---------- Results: Over the 10-year survey period, 1,462 practitioners returned survey forms representing a total of 13,721 contact lens fittings. The mean age (± SD) of lens wearers was 33.2 ± 13.6 years and 65 per cent were female. Between 2006 and 2009, rigid lens new fittings decreased from 18 to one per cent. Low water content lenses reduced from 11.5 to 3.2 per cent of soft lens fittings between 2000 and 2008. Between 2005 and 2009, toric lenses and multifocal lenses represented 26 and eight per cent, respectively, of all soft lenses fitted. Daily disposable, one- to two-week replacement and monthly replacement lenses accounted for 11.6, 30.0 and 46.5 per cent of all soft lens fittings over the survey period, respectively. The proportion of new soft fittings and refittings prescribed as extended wear has generally declined throughout the past decade. Multi-purpose lens care solutions dominate the market. Rigid lenses and monthly replacement soft lenses are predominantly worn on a full-time basis, whereas daily disposable soft lenses are mainly worn part-time.---------- Conclusions: This survey indicates that technological advances, such as the development of new lens materials, manufacturing methods and lens designs, and the availability of various lens replacement options, have had a significant impact on the contact lens market during the first decade of the 21st Century.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was designed to derive central and peripheral oxygen transmissibility (Dk/t) thresholds for soft contact lenses to avoid hypoxia-induced corneal swelling (increased corneal thickness) during open eye wear. Central and peripheral corneal thicknesses were measured in a masked and randomized fashion for the left eye of each of seven subjects before and after 3 h of afternoon wear of five conventional hydrogel and silicone hydrogel contact lens types offering a range of Dk/t from 2.4 units to 115.3 units. Curve fitting for plots of change in corneal thickness versus central and peripheral Dk/t found threshold values of 19.8 and 32.6 units to avoid corneal swelling during open eye contact lens wear for a typical wearer. Although some conventional hydrogel soft lenses are able to achieve this criterion for either central or peripheral lens areas (depending on lens power), in general, no conventional hydrogel soft lenses meet both the central and peripheral thresholds. Silicone hydrogel contact lenses typically meet both the central and peripheral thresholds and use of these lenses therefore avoids swelling in all regions of the cornea. ' 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 92B: 361–365, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim was to construct and advise on the use of a cost-per-wear model based on contact lens replacement frequency, to form an equitable basis for cost comparison. ---------- Methods: The annual cost of professional fees, contact lenses and solutions when wearing daily, two-weekly and monthly replacement contact lenses is determined in the context of the Australian market for spherical, toric and multifocal prescription types. This annual cost is divided by the number of times lenses are worn per year, resulting in a ‘cost-per-wear’. The model is presented graphically as the cost-per-wear versus the number of times lenses are worn each week for daily replacement and reusable (two-weekly and monthly replacement) lenses.---------- Results: The cost-per-wear for two-weekly and monthly replacement spherical lenses is almost identical but decreases with increasing frequency of wear. The cost-per-wear of daily replacement spherical lenses is lower than for reusable spherical lenses, when worn from one to four days per week but higher when worn six or seven days per week. The point at which the cost-per-wear is virtually the same for all three spherical lens replacement frequencies (approximately AUD$3.00) is five days of lens wear per week. A similar but upwardly displaced (higher cost) pattern is observed for toric lenses, with the cross-over point occurring between three and four days of wear per week (AUD$4.80). Multifocal lenses have the highest price, with cross-over points for daily versus two-weekly replacement lenses at between four and five days of wear per week (AUD$5.00) and for daily versus monthly replacement lenses at three days per week (AUD$5.50).---------- Conclusions: This cost-per-wear model can be used to assist practitioners and patients in making an informed decision in relation to the cost of contact lens wear as one of many considerations that must be taken into account when deciding on the most suitable lens replacement modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silicone hydrogel contact lenses were introduced into the market in 1999. To assess prescribing trends of this lens type since then, up to 1000 survey forms were sent to contact lens fitters in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA each year between 2000 and 2008. Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Analysis of returned forms revealed a rapid increase in the prescribing of silicone hydrogel lenses over the survey period. In 2008, silicone hydrogel lenses represented 36% of all soft lenses prescribed. The categorization of the majority of lenses prescribed as ‘refits’ is primarily attributed to the mass conversion of lens wearers from hydrogel to silicone hydrogel lenses. Silicone hydrogels may soon represent the majority of soft contact lenses prescribed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Daily disposable contact lenses were introduced into the market 16 years ago. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, The Netherlands, Norway, the UK and the USA between 2000 and 2008 indicates an overall increase in daily disposable lens fitting during this period. Daily disposable lenses are especially popular in Japan, Norway and the UK. There is a trend for these lenses to be fitted on a part-time basis. Males are over-represented in daily disposable lens fitting—a trend that is especially evident in Canada. Daily disposable lens wearers are about two years younger than wearers of reusable lenses in Japan and The Netherlands. The convenience and health benefits of daily disposable lenses are expected to fuel continued growth in this sector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Knowledge of differences in the demographics of contact lens prescribing between nations, and changes over time, can assist (a) the contact lens industry in developing and promoting various product types in different world regions, and (b) practitioners in understanding their prescribing habits in an international context. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA between 2000 and 2008 reveal an ageing demographic, with Japan being the most youthful. The majority of fits are to females, with statistically significant differences between nations, ranging from 62 per cent of fits in Norway to 68 per cent in Japan. The small overall decline in the proportion of new fits, and commensurate increase in refits, over the survey periodmay indicate a growing rate of conversion of lens wearers to more advanced lens types, such as silicone hydrogels. � 2009 British Contact Lens Association.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thoroughly revised and updated, this popular book provides a comprehensive yet easy to read guide to modern contact lens practice. Beautifully re-designed in a clean, contemporary layout, this second edition presents relevant and up-to-date information in a systematic manner, with a logical flow of subject matter from front to back. This book wonderfully captures the ‘middle ground’ in the contact lens field … somewhere between a dense research-based tome and a basic fitting guide. As such, it is ideally suited for both students and general eye care practitioners who require a practical, accessible and uncluttered account of the contact lens field. Contents Part 1 Introduction Historical perspective. The anterior eye Visual optics Clinical instruments Part 2 Soft contact lenses Soft lens materials Soft lens manufacture Soft lens optics Soft lens measurement Soft lens design and fitting Soft toric lens design and fitting Soft lens care systems Part 3 Rigid contact lenses Rigid lens materials Rigid lens manufacture Rigid lens optics Rigid lens measurement Rigid lens design and fitting Rigid toric lens design and fitting Rigid lens care systems Part 4 Lens replacement modalities Unplanned lens replacement Daily soft lens replacement Planned soft lens replacement Planned rigid lens replacement Part 5 Special lenses and fitting considerations Scleral lenses Tinted lenses Presbyopia Continuous wear Sport Keratoconus High ametropia Paediatric fitting Therapeutic applications Post-refractive Surgery Post-keratoplasty Orthokeratology Diabetes Part 6 Patient examination and management History taking Preliminary examination Patient education Aftercare Complications Digital imaging Compliance Practice management Appendices Index

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Despite declining rates of cardiovascular disease (CVD) mortality in developed countries, lower socioeconomic groups continue to experience a greater burden of the disease. There are now many evidence-based treatments and prevention strategies for the management of CVD and it is essential that their impact on the more disadvantaged group is understood if socioeconomic inequalities in CVD are to be reduced. Aims: To determine whether key interventions for CVD prevention and treatment are effective among lower socioeconomic groups, to describe barriers to their effectiveness and the potential or actual impact of these interventions on the socioeconomic gradient in CVD. Methods: Interventions were selected from four stages of the CVD continuum. These included smoking reduction strategies, absolute risk assessment, cardiac rehabilitation, secondary prevention medications, and heart failure self-management programmes. Electronic searches were conducted using terms for each intervention combined with terms for socioeconomic status (SES). Results: Only limited evidence was found for the effectiveness of the selected interventions among lower SES groups and there was little exploration of socioeconomic-related barriers to their uptake. Some broad themes and key messages were identified. In the majority of findings examined, it was clear that the underlying material, social and environmental factors associated with disadvantage are a significant barrier to the effectiveness of interventions. Conclusion: Opportunities to reduce socioeconomic inequalities occur at all stages of the CVD continuum. Despite this, current treatment and prevention strategies may be contributing to the widening socioeconomic-CVD gradient. Further research into the impact of best-practice interventions for CVD upon lower SES groups is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the capabilities of laser scanning confocal microscopy (LSCM) for undertaking qualitative and quantitative investigations of the response of the bulbar conjunctiva to contact lens wear. Methods: LSCM was used to observe and measure morphological characteristics of the bulbar conjunctiva of 11 asymptomatic soft contact lens wearers and 11 healthy volunteer subjects (controls). Results: The appearance of the bulbar conjunctiva is consistent with known histology of this tissue based on light and electron microscopy. The thickness of the bulbar conjunctival epithelium of lens wearers (30.9 ± 1.1 μm) was less than that of controls (32.9 ± 1.1 μm) (P < 0.0001). Superficial and basal bulbar conjunctival epithelial cell densities in contact lens wearers were 91% and 79% higher, respectively, than that in controls (P < 0.0001). No difference was observed in goblet and Langerhans cell density between lens wearers and controls. Conjunctival microcysts were observed in greater numbers, and were larger in size, in lens wearers compared with controls. Conclusions: The effects of contact lens wear on the human bulbar conjunctiva can be investigated effectively at a cellular level using LSCM. The observations in this study suggest that contact lens wear can induce changes in the bulbar conjunctiva such as epithelial thinning and accelerated formation and enlargement of microcysts, increased epithelial cell density, but has no impact on goblet or Langerhans cell density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There have been significant improvements in toric soft contact lens design over the past decade. Data from our international contact lens prescribing survey were mined to assess recent trends in toric soft contact lens fitting. This survey was conducted by sending up to 1000 survey forms to contact lens fitters in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA each year between 2000 and 2009. Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the forms and to return them to us for analysis. The data revealed a gradual increase in the extent of toric soft lens fitting this century. Excluding Japan – which had a consistently low rate of soft toric lens fitting over the survey period – soft toric lenses now represent over 35% of all soft lenses prescribed; it can be assumed that, on average (and again excluding Japan), all cases of astigmatism 0.75 D or less remains uncorrected among contact lens wearers. Toric lenses are fitted more to those who are older, full-time wearers and reusable lens wearers, and less to those wearing silicone hydrogel and extended wear lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the paper is to provide a collaborative practitioner/academic interpretation of a destination’s competitiveness through the lens of brand positioning in the domestic short break drive market. A 173 item questionnaire, which was mailed to a systematic random sample of 3000 households in the target market, attracted a 17% useable response. The paper compares how one destination, the Sunshine Coast, is positioned in its most important market, in relation to the brand identity intended by the destination marketing organisation (DMO). Key constructs were brand salience, brand associations and brand resonance. The Sunshine Coast was found to hold a leadership position in the minds of consumers, and the results indicated a strong level of congruence between actual market perceptions and the brand identity intended by the DMO. There were strong associations between brand salience, brand associations and brand resonance. The findings provided the destination of interest with both a measure of past marketing effectiveness as well as positive indicators of future performance. The paper represents collaboration between a tourism practitioner and a tourism academic, and attempts a contribution to the emerging literature on destination competitiveness through the lens of positioning theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim was to determine world-wide patterns of fitting contact lenses for the correction of presbyopia. Methods: Up to 1,000 survey forms were sent to contact lens fitters in each of 38 countries between January and March every year over five consecutive years (2005 to 2009). Practitioners were asked to record data relating to the first 10 contact lens fittings or refittings performed after receiving the survey form. Results: Data were received relating to 16,680 presbyopic (age 45 years or older) and 84,202 pre-presbyopic (15 to 44 years) contact lens wearers. Females are over-represented in presbyopic versus pre-presbyopic groups, possibly reflecting a stronger desire for the cosmetic benefits of contact lenses among older women. The extent to which multifocal and monovision lenses are prescribed for presbyopes varies considerably among nations, ranging from 79 per cent of all soft lenses in Portugal to zero in Singapore. There appears to be significant under-prescribing of contact lenses for the correction of presbyopia, although for those who do receive such corrections, three times more multifocal lenses are fitted compared with monovision fittings. Presbyopic corrections are most frequently prescribed for full-time wear and monthly replacement. Conclusions: Despite apparent improvements in multifocal design and an increase in available multifocal options in recent years, practitioners are still under-prescribing with respect to the provision of appropriate contact lenses for the correction of presbyopia. Training of contact lens practitioners in presbyopic contact lens fitting should be accelerated and clinical and laboratory research in this field should be intensified to enhance the prospects of meeting the needs of presbyopic contact lens wearers more fully.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The depth of focus (DOF) can be defined as the variation in image distance of a lens or an optical system which can be tolerated without incurring an objectionable lack of sharpness of focus. The DOF of the human eye serves a mechanism of blur tolerance. As long as the target image remains within the depth of focus in the image space, the eye will still perceive the image as being clear. A large DOF is especially important for presbyopic patients with partial or complete loss of accommodation (presbyopia), since this helps them to obtain an acceptable retinal image when viewing a target moving through a range of near to intermediate distances. The aim of this research was to investigate the DOF of the human eye and its association with the natural wavefront aberrations, and how higher order aberrations (HOAs) can be used to expand the DOF, in particular by inducing spherical aberrations ( 0 4 Z and 0 6 Z ). The depth of focus of the human eye can be measured using a variety of subjective and objective methods. Subjective measurements based on a Badal optical system have been widely adopted, through which the retinal image size can be kept constant. In such measurements, the subject.s tested eye is normally cyclopleged. Objective methods without the need of cycloplegia are also used, where the eye.s accommodative response is continuously monitored. Generally, the DOF measured by subjective methods are slightly larger than those measured objectively. In recent years, methods have also been developed to estimate DOF from retinal image quality metrics (IQMs) derived from the ocular wavefront aberrations. In such methods, the DOF is defined as the range of defocus error that degrades the retinal image quality calculated from the IQMs to a certain level of the possible maximum value. In this study, the effect of different amounts of HOAs on the DOF was theoretically evaluated by modelling and comparing the DOF of subjects from four different clinical groups, including young emmetropes (20 subjects), young myopes (19 subjects), presbyopes (32 subjects) and keratoconics (35 subjects). A novel IQM-based through-focus algorithm was developed to theoretically predict the DOF of subjects with their natural HOAs. Additional primary spherical aberration ( 0 4 Z ) was also induced in the wavefronts of myopes and presbyopes to simulate the effect of myopic refractive correction (e.g. LASIK) and presbyopic correction (e.g. progressive power IOL) on the subject.s DOF. Larger amounts of HOAs were found to lead to greater values of predicted DOF. The introduction of primary spherical aberration was found to provide moderate increase of DOF while slightly deteriorating the image quality at the same time. The predicted DOF was also affected by the IQMs and the threshold level adopted. We then investigated the influence of the chosen threshold level of the IQMs on the predicted DOF, and how it relates to the subjectively measured DOF. The subjective DOF was measured in a group of 17 normal subjects, and we used through-focus visual Strehl ratio based on optical transfer function (VSOTF) derived from their wavefront aberrations as the IQM to estimate the DOF. The results allowed comparison of the subjective DOF with the estimated DOF and determination of a threshold level for DOF estimation. Significant correlation was found between the subject.s estimated threshold level for the estimated DOF and HOA RMS (Pearson.s r=0.88, p<0.001). The linear correlation can be used to estimate the threshold level for each individual subject, subsequently leading to a method for estimating individual.s DOF from a single measurement of their wavefront aberrations. A subsequent study was conducted to investigate the DOF of keratoconic subjects. Significant increases of the level of HOAs, including spherical aberration, coma and trefoil, can be observed in keratoconic eyes. This population of subjects provides an opportunity to study the influence of these HOAs on DOF. It was also expected that the asymmetric aberrations (coma and trefoil) in the keratoconic eye could interact with defocus to cause regional blur of the target. A dual-Badal-channel optical system with a star-pattern target was used to measure the subjective DOF in 10 keratoconic eyes and compared to those from a group of 10 normal subjects. The DOF measured in keratoconic eyes was significantly larger than that in normal eyes. However there was not a strong correlation between the large amount of HOA RMS and DOF in keratoconic eyes. Among all HOA terms, spherical aberration was found to be the only HOA that helped to significantly increase the DOF in the studied keratoconic subjects. Through the first three studies, a comprehensive understanding of DOF and its association to the HOAs in the human eye had been achieved. An adaptive optics system was then designed and constructed. The system was capable of measuring and altering the wavefront aberrations in the subject.s eye and measuring the resulting DOF under the influence of different combination of HOAs. Using the AO system, we investigated the concept of extending the DOF through optimized combinations of 0 4 Z and 0 6 Z . Systematic introduction of a targeted amount of both 0 4 Z and 0 6 Z was found to significantly improve the DOF of healthy subjects. The use of wavefront combinations of 0 4 Z and 0 6 Z with opposite signs can further expand the DOF, rather than using 0 4 Z or 0 6 Z alone. The optimal wavefront combinations to expand the DOF were estimated using the ratio of increase in DOF and loss of retinal image quality defined by VSOTF. In the experiment, the optimal combinations of 0 4 Z and 0 6 Z were found to provide a better balance of DOF expansion and relatively smaller decreases in VA. Therefore, the optimal combinations of 0 4 Z and 0 6 Z provides a more efficient method to expand the DOF rather than 0 4 Z or 0 6 Z alone. This PhD research has shown that there is a positive correlation between the DOF and the eye.s wavefront aberrations. More aberrated eyes generally have a larger DOF. The association of DOF and the natural HOAs in normal subjects can be quantified, which allows the estimation of DOF directly from the ocular wavefront aberration. Among the Zernike HOA terms, spherical aberrations ( 0 4 Z and 0 6 Z ) were found to improve the DOF. Certain combinations of 0 4 Z and 0 6 Z provide a more effective method to expand DOF than using 0 4 Z or 0 6 Z alone, and this could be useful in the optimal design of presbyopic optical corrections such as multifocal contact lenses, intraocular lenses and laser corneal surgeries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a novel method and instrument for in vivo imaging and measurement of the human corneal dynamics during an air puff. The instrument is based on high-speed swept source optical coherence tomography (ssOCT) combined with a custom adapted air puff chamber from a non-contact tonometer, which uses an air stream to deform the cornea in a non-invasive manner. During the short period of time that the deformation takes place, the ssOCT acquires multiple A-scans in time (M-scan) at the center of the air puff, allowing observation of the dynamics of the anterior and posterior corneal surfaces as well as the anterior lens surface. The dynamics of the measurement are driven by the biomechanical properties of the human eye as well as its intraocular pressure. Thus, the analysis of the M-scan may provide useful information about the biomechanical behavior of the anterior segment during the applanation caused by the air puff. An initial set of controlled clinical experiments are shown to comprehend the performance of the instrument and its potential applicability to further understand the eye biomechanics and intraocular pressure measurements. Limitations and possibilities of the new apparatus are discussed.