56 resultados para flat and curved layer slicing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Organic thin films have myriad of applications in biological interfaces, micro-electromechanical systems and organic electronics. Polyterpenol thin films fabricated via RF plasma polymerization have been substantiated as a promising gate insulating and encapsulating layer for organic optoelectronics, sacrificial place-holders for air gap fabrication as well as antibacterial coatings for medical implants. This study aims to understand the wettability and solubility behavior of the nonsynthetic polymer thin film, polyterpenol. Polyterpenol exhibited monopolar behavior, manifesting mostly electron donor properties, and was not water soluble due to the extensive intermolecular and intramolecular hydrogen bonds present. Hydrophobicity of polyterpenol surfaces increased for films fabricated at higher RF power attributed to reduction in oxygen containing functional groups and increased cross linking. The studies carried out under various deposition conditions vindicate that we could tailor the properties of the polyterpenol thin film for a given application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the results of an experimental and numerical program to investigate the circular hollow section (CHS) beams, strengthened using Carbon Fibre Reinforced Polymer (CFRP) sheets. The circular hollow shaped steel beams bonded with different CFRP layer orientations were tested under four-point bending. The mid-span deflection, service load and failure load were recorded. The LHL (where L, first inner longitudinal layer, H, second hoop layer and L, third outer longitudinal layer) and LLH (where L, first inner longitudinal layer, L, second longitudinal layer and H, third outer hoop layer) layer oriented strengthened beams perform slightly better than HHL (where H, first inner hoop layer, H, second hoop layer and L, third outer longitudinal layer) layer oriented strengthened beams. The LHL and LLH layer oriented treated beams showed very similar structural behaviour. Numerical analyses were then conducted on the CFRP strengthened steel CHS beams. The validity of the models has been assessed by comparing the failure loads and mid-span deflections. The effects of various parameters such as bond length, section types, tensile modulus of CFRP, adhesive layer thickness and adhesive types have been studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This two-part research project was undertaken as part of the planning process by Queensland Health (QH), Cancer Screening Services Unit (CSSU), Queensland Bowel Cancer Screening Program (QBCSP), in partnership with the National Bowel Cancer Screening Program (NBCSP), to prepare for the implementation of the NBCSP in public sector colonoscopy services in QLD in late 2006. There was no prior information available on the quality of colonoscopy services in Queensland (QLD) and no prior studies that assessed the quality of colonoscopy training in Australia. Furthermore, the NBCSP was introduced without extra funding for colonoscopy service improvement or provision for increases in colonoscopic capacity resulting from the introduction of the NBCSP. The main purpose of the research was to record baseline data on colonoscopy referral and practice in QLD and current training in colonoscopy Australia-wide. It was undertaken from a quality improvement perspective. Implementation of the NBCSP requires that all aspects of the screening pathway, in particular colonoscopy services for the assessment of positive Faecal Occult Blood Tests (FOBTs), will be effective, efficient, equitable and evidence-based. This study examined two important aspects of the continuous quality improvement framework for the NBCSP as they relate to colonoscopy services: (1) evidence-based practice, and (2) quality of colonoscopy training. The Principal Investigator was employed as Senior Project Officer (Training) in the QBCSP during the conduct of this research project. Recommendations from this research have been used to inform the development and implementation of quality improvement initiatives for provision of colonoscopy in the NBCSP, its QLD counterpart the QBCSP and colonoscopy services in QLD, in general. Methods – Part 1 Chart audit of evidence-based practice: The research was undertaken in two parts from 2005-2007. The first part of this research comprised a retrospective chart audit of 1484 colonoscopy records (some 13% of all colonoscopies conducted in public sector facilities in the year 2005) in three QLD colonoscopy services. Whilst some 70% of colonoscopies are currently conducted in the private sector, only public sector colonoscopy facilities provided colonoscopies under the NBCSP. The aim of this study was to compare colonoscopy referral and practice with explicit criteria derived from the National Health & Medical Research Council (NHMRC) (1999) Clinical Practice Guidelines for the Prevention, Early Detection and Management of Colorectal Cancer, and describe the nature of variance with the guidelines. Symptomatic presentations were the most common indication for colonoscopy (60.9%). These comprised per rectal bleeding (31.0%), change of bowel habit (22.1%), abdominal pain (19.6%), iron deficiency anaemia (16.2%), inflammatory bowel disease (8.9%) and other symptoms (11.4%). Surveillance and follow-up colonoscopies accounted for approximately one-third of the remaining colonoscopy workload across sites. Gastroenterologists (GEs) performed relatively more colonoscopies per annum (59.9%) compared to general surgeons (GS) (24.1%), colorectal surgeons (CRS) (9.4%) and general physicians (GPs) (6.5%). Guideline compliance varied with the designation of the colonoscopist. Compliance was lower for CRS (62.9%) compared to GPs (76.0%), GEs (75.0%), GSs (70.9%, p<0.05). Compliance with guideline recommendations for colonoscopic surveillance for family history of colorectal cancer (23.9%), polyps (37.0%) and a past history of bowel cancer (42.7%), was by comparison significantly lower than for symptomatic presentations (94.4%), (p<0.001). Variation with guideline recommendations occurred more frequently for polyp surveillance (earlier than guidelines recommend, 47.9%) and follow-up for past history of bowel cancer (later than recommended, 61.7%, p<0.001). Bowel cancer cases detected at colonoscopy comprised 3.6% of all audited colonoscopies. Incomplete colonoscopies occurred in 4.3% of audited colonoscopies and were more common among women (76.6%). For all colonoscopies audited, the rate of incomplete colonoscopies for GEs was 1.6% (CI 0.9-2.6), GPs 2.0% (CI 0.6-7.2), GS 7.0% (CI 4.8-10.1) and CRS 16.4% (CI 11.2-23.5). 18.6% (n=55) of patients with a documented family history of bowel cancer had colonoscopy performed against guidelines recommendations (for general (category 1) population risk, for reasons of patient request or family history of polyps, rather than for high risk status for colorectal cancer). In general, family history was inadequately documented and subsequently applied to colonoscopy referral and practice. Methods - Part 2 Surveys of quality of colonoscopy training: The second part of the research consisted of Australia-wide anonymous, self-completed surveys of colonoscopy trainers and their trainees to ascertain their opinions on the current apprenticeship model of colonoscopy in Australia and to identify any training needs. Overall, 127 surveys were received from colonoscopy trainers (estimated response rate 30.2%). Approximately 50% of trainers agreed and 27% disagreed that current numbers of training places were adequate to maintain a skilled colonoscopy workforce in preparation for the NBCSP. Approximately 70% of trainers also supported UK-style colonoscopy training within dedicated accredited training centres using a variety of training approaches including simulation. A collaborative approach with the private sector was seen as beneficial by 65% of trainers. Non-gastroenterologists (non-GEs) were more likely than GEs to be of the opinion that simulators are beneficial for colonoscopy training (χ2-test = 5.55, P = 0.026). Approximately 60% of trainers considered that the current requirements for recognition of training in colonoscopy could be insufficient for trainees to gain competence and 80% of those indicated that ≥ 200 colonoscopies were needed. GEs (73.4%) were more likely than non-GEs (36.2%) to be of the opinion that the Conjoint Committee standard is insufficient to gain competence in colonoscopy (χ2-test = 16.97, P = 0.0001). The majority of trainers did not support training either nurses (73%) or GPs in colonoscopy (71%). Only 81 (estimated response rate 17.9%) surveys were received from GS trainees (72.1%), GE trainees (26.3%) and GP trainees (1.2%). The majority were males (75.9%), with a median age 32 years and who had trained in New South Wales (41.0%) or Victoria (30%). Overall, two-thirds (60.8%) of trainees indicated that they deemed the Conjoint Committee standard sufficient to gain competency in colonoscopy. Between specialties, 75.4% of GS trainees indicated that the Conjoint Committee standard for recognition of colonoscopy was sufficient to gain competence in colonoscopy compared to only 38.5% of GE trainees. Measures of competency assessed and recorded by trainees in logbooks centred mainly on caecal intubation (94.7-100%), complications (78.9-100%) and withdrawal time (51-76.2%). Trainees described limited access to colonoscopy training lists due to the time inefficiency of the apprenticeship model and perceived monopolisation of these by GEs and their trainees. Improvements to the current training model suggested by trainees included: more use of simulation, training tools, a United Kingdom (UK)-style training course, concentration on quality indicators, increased access to training lists, accreditation of trainers and interdisciplinary colonoscopy training. Implications for the NBCSP/QBCSP: The introduction of the NBCSP/QBCSP necessitates higher quality colonoscopy services if it is to achieve its ultimate goal of decreasing the incidence of morbidity and mortality associated with bowel cancer in Australia. This will be achieved under a new paradigm for colonoscopy training and implementation of evidence-based practice across the screening pathway and specifically targeting areas highlighted in this thesis. Recommendations for improvement of NBCSP/QBCSP effectiveness and efficiency include the following: 1. Implementation of NBCSP and QBCSP health promotion activities that target men, in particular, to increase FOBT screening uptake. 2. Improved colonoscopy training for trainees and refresher courses or retraining for existing proceduralists to improve completion rates (especially for female NBCSP/QBCSP participants), and polyp and adenoma detection and removal, including newer techniques to detect flat and depressed lesions. 3. Introduction of colonoscopy training initiatives for trainees that are aligned with NBCSP/QBCSP colonoscopy quality indicators, including measurement of training outcomes using objective quality indicators such as caecal intubation, withdrawal time, and adenoma detection rate. 4. Introduction of standardised, interdisciplinary colonoscopy training to reduce apparent differences between specialties with regard to compliance with guideline recommendations, completion rates, and quality of polypectomy. 5. Improved quality of colonoscopy training by adoption of a UK-style training program with centres of excellence, incorporating newer, more objective assessment methods, use of a variety of training tools such as simulation and rotations of trainees between metropolitan, rural, and public and private sector training facilities. 6. Incorporation of NHMRC guidelines into colonoscopy information systems to improve documentation, provide guideline recommendations at the point of care, use of gastroenterology nurse coordinators to facilitate compliance with guidelines and provision of guideline-based colonoscopy referral letters for GPs. 7. Provision of information and education about the NBCSP/QBCSP, bowel cancer risk factors, including family history and polyp surveillance guidelines, for participants, GPs and proceduralists. 8. Improved referral of NBCSP/QBCSP participants found to have a high-risk family history of bowel cancer to appropriate genetics services.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis aimed to investigate the way in which distance runners modulate their speed in an effort to understand the key processes and determinants of speed selection when encountering hills in natural outdoor environments. One factor which has limited the expansion of knowledge in this area has been a reliance on the motorized treadmill which constrains runners to constant speeds and gradients and only linear paths. Conversely, limits in the portability or storage capacity of available technology have restricted field research to brief durations and level courses. Therefore another aim of this thesis was to evaluate the capacity of lightweight, portable technology to measure running speed in outdoor undulating terrain. The first study of this thesis assessed the validity of a non-differential GPS to measure speed, displacement and position during human locomotion. Three healthy participants walked and ran over straight and curved courses for 59 and 34 trials respectively. A non-differential GPS receiver provided speed data by Doppler Shift and change in GPS position over time, which were compared with actual speeds determined by chronometry. Displacement data from the GPS were compared with a surveyed 100m section, while static positions were collected for 1 hour and compared with the known geodetic point. GPS speed values on the straight course were found to be closely correlated with actual speeds (Doppler shift: r = 0.9994, p < 0.001, Δ GPS position/time: r = 0.9984, p < 0.001). Actual speed errors were lowest using the Doppler shift method (90.8% of values within ± 0.1 m.sec -1). Speed was slightly underestimated on a curved path, though still highly correlated with actual speed (Doppler shift: r = 0.9985, p < 0.001, Δ GPS distance/time: r = 0.9973, p < 0.001). Distance measured by GPS was 100.46 ± 0.49m, while 86.5% of static points were within 1.5m of the actual geodetic point (mean error: 1.08 ± 0.34m, range 0.69-2.10m). Non-differential GPS demonstrated a highly accurate estimation of speed across a wide range of human locomotion velocities using only the raw signal data with a minimal decrease in accuracy around bends. This high level of resolution was matched by accurate displacement and position data. Coupled with reduced size, cost and ease of use, the use of a non-differential receiver offers a valid alternative to differential GPS in the study of overground locomotion. The second study of this dissertation examined speed regulation during overground running on a hilly course. Following an initial laboratory session to calculate physiological thresholds (VO2 max and ventilatory thresholds), eight experienced long distance runners completed a self- paced time trial over three laps of an outdoor course involving uphill, downhill and level sections. A portable gas analyser, GPS receiver and activity monitor were used to collect physiological, speed and stride frequency data. Participants ran 23% slower on uphills and 13.8% faster on downhills compared with level sections. Speeds on level sections were significantly different for 78.4 ± 7.0 seconds following an uphill and 23.6 ± 2.2 seconds following a downhill. Speed changes were primarily regulated by stride length which was 20.5% shorter uphill and 16.2% longer downhill, while stride frequency was relatively stable. Oxygen consumption averaged 100.4% of runner’s individual ventilatory thresholds on uphills, 78.9% on downhills and 89.3% on level sections. Group level speed was highly predicted using a modified gradient factor (r2 = 0.89). Individuals adopted distinct pacing strategies, both across laps and as a function of gradient. Speed was best predicted using a weighted factor to account for prior and current gradients. Oxygen consumption (VO2) limited runner’s speeds only on uphill sections, and was maintained in line with individual ventilatory thresholds. Running speed showed larger individual variation on downhill sections, while speed on the level was systematically influenced by the preceding gradient. Runners who varied their pace more as a function of gradient showed a more consistent level of oxygen consumption. These results suggest that optimising time on the level sections after hills offers the greatest potential to minimise overall time when running over undulating terrain. The third study of this thesis investigated the effect of implementing an individualised pacing strategy on running performance over an undulating course. Six trained distance runners completed three trials involving four laps (9968m) of an outdoor course involving uphill, downhill and level sections. The initial trial was self-paced in the absence of any temporal feedback. For the second and third field trials, runners were paced for the first three laps (7476m) according to two different regimes (Intervention or Control) by matching desired goal times for subsections within each gradient. The fourth lap (2492m) was completed without pacing. Goals for the Intervention trial were based on findings from study two using a modified gradient factor and elapsed distance to predict the time for each section. To maintain the same overall time across all paced conditions, times were proportionately adjusted according to split times from the self-paced trial. The alternative pacing strategy (Control) used the original split times from this initial trial. Five of the six runners increased their range of uphill to downhill speeds on the Intervention trial by more than 30%, but this was unsuccessful in achieving a more consistent level of oxygen consumption with only one runner showing a change of more than 10%. Group level adherence to the Intervention strategy was lowest on downhill sections. Three runners successfully adhered to the Intervention pacing strategy which was gauged by a low Root Mean Square error across subsections and gradients. Of these three, the two who had the largest change in uphill-downhill speeds ran their fastest overall time. This suggests that for some runners the strategy of varying speeds systematically to account for gradients and transitions may benefit race performances on courses involving hills. In summary, a non – differential receiver was found to offer highly accurate measures of speed, distance and position across the range of human locomotion speeds. Self-selected speed was found to be best predicted using a weighted factor to account for prior and current gradients. Oxygen consumption limited runner’s speeds only on uphills, speed on the level was systematically influenced by preceding gradients, while there was a much larger individual variation on downhill sections. Individuals were found to adopt distinct but unrelated pacing strategies as a function of durations and gradients, while runners who varied pace more as a function of gradient showed a more consistent level of oxygen consumption. Finally, the implementation of an individualised pacing strategy to account for gradients and transitions greatly increased runners’ range of uphill-downhill speeds and was able to improve performance in some runners. The efficiency of various gradient-speed trade- offs and the factors limiting faster downhill speeds will however require further investigation to further improve the effectiveness of the suggested strategy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the results of a series of tension tests on CFRP bonded steel plate double strap joints. The main aim of this research is to provide detailed understanding of bond characteristics using experimental and numerical analysis of strengthened double strap joints under tension. A parametric study has been performed by numerical modelling with the variables of CFRP bond lengths, adhesive maximum strain and adhesive layer thicknesses. Finally, bond-slip models are proposed for three different types of adhesives within the range of the parametric study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This chapter reviews green grains from the shelf of French Guiana as a regional example of sedimentologic process occurring on the whole stable continental margin from the Amazon to the Orinoco River. Green grains have been observed and analyzed off the Orinoco delta and on the continental shelf of Surinam. These green grains were identified as “chamosite” and “glauconite.” The muddy coast of French Guiana is generally very flat and occupied by wet swamps and mangrove as a result of the equatorial climate. Most green grains on the continental shelf represent the verdine facies. Green grains are ubiquitous on the shelf and top of the slope off French Guiana. Two sedimentological facies exist: glaucony deeper than 150 m and verdine at shallower depths. The verdine facies has mainly developed from mineral debris and especially chloritized biotite. Carbonate bioclasts and faecal pellets are also utilized. The mica flakes were never wholly replaced by authigenic clay and the phenomenon leads to mixed grains where authigenic and substrate remains are recognizable. Carbonate substrates lead to mainly clay pure green grains becasue the initial carbonate has been dissolved. The formation of verdine can be located in a general marine environment at a comparatively warm sea-water temperature and at a depth probably shallower than 60 m.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modelling video sequences by subspaces has recently shown promise for recognising human actions. Subspaces are able to accommodate the effects of various image variations and can capture the dynamic properties of actions. Subspaces form a non-Euclidean and curved Riemannian manifold known as a Grassmann manifold. Inference on manifold spaces usually is achieved by embedding the manifolds in higher dimensional Euclidean spaces. In this paper, we instead propose to embed the Grassmann manifolds into reproducing kernel Hilbert spaces and then tackle the problem of discriminant analysis on such manifolds. To achieve efficient machinery, we propose graph-based local discriminant analysis that utilises within-class and between-class similarity graphs to characterise intra-class compactness and inter-class separability, respectively. Experiments on KTH, UCF Sports, and Ballet datasets show that the proposed approach obtains marked improvements in discrimination accuracy in comparison to several state-of-the-art methods, such as the kernel version of affine hull image-set distance, tensor canonical correlation analysis, spatial-temporal words and hierarchy of discriminative space-time neighbourhood features.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In previous Analytical Electron Microscope studies of extraterrestrial Chondritic Porous Aggregate (CPA) W7029* A, we have reported on the presence of layer silicates(Rietmeijer and Mackinnon, 1984a; Mackinnon and Rietmeijer, 1983) and metal oxides (Rietmeijer and Mackinnon, 1984a; Mackinnon and Rietmeijer, 1984). We present here a continuation ofthis detailed mineralogical study and propose a scenario which may account for the variety and types of phases observed in this CPA. At least 50% ofCPA W7029*A is carbonaceous material, primarily poorly graphitised carbon (POC) with morphologies similar to POC in acid residues of carbonaceous chondrites (Smith and Busek, 1981; Lumpkin, 1983). The basal spacing of graphite in CPA W7029*A ranges from 3.47-3.52 A and compares with doo, of graphite in the Allende residues (Smith and Buseck, 1981; Lumpkin, 1983). Low-temperature phases comprise - 20% of CPA W7029*A and include layer silicates, Bi,O" a-FeOOH(Rietmeijer and Mackinnon, 1984a; Mackinnon and Rietmeijer, 1983), BaSO.,.Ti.O, plates, pentlandite-violarite and bornite. Clusters of Mg-rich olivine and pyroxene make up - 12% of the aggregate...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many older people have difficulties using modern consumer products due to increased product complexity both in terms of functionality and interface design. Previous research has shown that older people have more difficulty in using complex devices intuitively when compared to the younger. Furthermore, increased life expectancy and a falling birth rate have been catalysts for changes in world demographics over the past two decades. This trend also suggests a proportional increase of older people in the work-force. This realisation has led to research on the effective use of technology by older populations in an effort to engage them more productively and to assist them in leading independent lives. Ironically, not enough attention has been paid to the development of interaction design strategies that would actually enable older users to better exploit new technologies. Previous research suggests that if products are designed to reflect people's prior knowledge, they will appear intuitive to use. Since intuitive interfaces utilise domain-specific prior knowledge of users, they require minimal learning for effective interaction. However, older people are very diverse in their capabilities and domain-specific prior knowledge. In addition, ageing also slows down the process of acquiring new knowledge. Keeping these suggestions and limitations in view, the aim of this study was set to investigate possible approaches to developing interfaces that facilitate their intuitive use by older people. In this quest to develop intuitive interfaces for older people, two experiments were conducted that systematically investigated redundancy (the use of both text and icons) in interface design, complexity of interface structure (nested versus flat), and personal user factors such as cognitive abilities, perceived self-efficacy and technology anxiety. All of these factors could interfere with intuitive use. The results from the first experiment suggest that, contrary to what was hypothesised, older people (65+ years) completed the tasks on the text only based interface design faster than on the redundant interface design. The outcome of the second experiment showed that, as expected, older people took more time on a nested interface. However, they did not make significantly more errors compared with younger age groups. Contrary to what was expected, older age groups also did better under anxious conditions. The findings of this study also suggest that older age groups are more heterogeneous in their capabilities and their intuitive use of contemporary technological devices is mediated more by domain-specific technology prior knowledge and by their cognitive abilities, than chronological age. This makes it extremely difficult to develop product interfaces that are entirely intuitive to use. However, by keeping in view the cognitive limitations of older people when interfaces are developed, and using simple text-based interfaces with flat interface structure, would help them intuitively learn and use complex technological products successfully during early encounter with a product. These findings indicate that it might be more pragmatic if interfaces are designed for intuitive learning rather than for intuitive use. Based on this research and the existing literature, a model for adaptable interface design as a strategy for developing intuitively learnable product interfaces was proposed. An adaptable interface can initially use a simple text only interface to help older users to learn and successfully use the new system. Over time, this can be progressively changed to a symbols-based nested interface for more efficient and intuitive use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the shape design optimisation using morphing aerofoil/wing techniques, namely the leading and/or trailing edge deformation of a natural laminar flow RAE 5243 aerofoil is investigated to reduce transonic drag without taking into account of the piezo actuator mechanism. Two applications using a Multi-Objective Genetic Algorithm (MOGA)coupled with Euler and boundary analyser (MSES) are considered: the first example minimises the total drag with a lift constraint by optimising both the trailing edge actuator position and trailing edge deformation angle at a constant transonic Mach number (M! = 0.75)and boundary layer transition position (xtr = 45%c). The second example consists of finding reliable designs that produce lower mean total drag (μCd) and drag sensitivity ("Cd) at different uncertainty flight conditions based on statistical information. Numerical results illustrate how the solution quality in terms of mean drag and its sensitivity can be improved using MOGA software coupled with a robust design approach taking account of uncertainties (lift and boundary transition positions) and also how transonic flow over aerofoil/wing can be controlled to the best advantage using morphing techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nanomaterials are prone to influence by chemical adsorption because of their large surface to volume ratios. This enables sensitive detection of adsorbed chemical species which, in turn, can tune the property of the host material. Recent studies discovered that single and multi-layer molybdenum disulfide (MoS2) films are ultra-sensitive to several important environmental molecules. Here we report new findings from ab inito calculations that reveal substantially enhanced adsorption of NO and NH3 on strained monolayer MoS2 with significant impact on the properties of the adsorbates and the MoS2 layer. The magnetic moment of adsorbed NO can be tuned between 0 and 1 μB; strain also induces an electronic phase transition between half-metal and metal. Adsorption of NH3 weakens the MoS2 layer considerably, which explains the large discrepancy between the experimentally measured strength and breaking strain of MoS2 films and previous theoretical predictions. On the other hand, adsorption of NO2, CO, and CO2 is insensitive to the strain condition in the MoS2 layer. This contrasting behavior allows sensitive strain engineering of selective chemical adsorption on MoS2 with effective tuning of mechanical, electronic, and magnetic properties. These results suggest new design strategies for constructing MoS2-based ultrahigh-sensitivity nanoscale sensors and electromechanical devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mass spectrometry is now an indispensable tool for lipid analysis and is arguably the driving force in the renaissance of lipid research. In its various forms, mass spectrometry is uniquely capable of resolving the extensive compositional and structural diversity of lipids in biological systems. Furthermore, it provides the ability to accurately quantify molecular-level changes in lipid populations associated with changes in metabolism and environment; bringing lipid science to the "omics" age. The recent explosion of mass spectrometry-based surface analysis techniques is fuelling further expansion of the lipidomics field. This is evidenced by the numerous papers published on the subject of mass spectrometric imaging of lipids in recent years. While imaging mass spectrometry provides new and exciting possibilities, it is but one of the many opportunities direct surface analysis offers the lipid researcher. In this review we describe the current state-of-the-art in the direct surface analysis of lipids with a focus on tissue sections, intact cells and thin-layer chromatography substrates. The suitability of these different approaches towards analysis of the major lipid classes along with their current and potential applications in the field of lipid analysis are evaluated. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A, dry, non-hydrostatic sub-cloud model is used to simulate an isolated stationary downburst wind event to study the influence topographic features have on the near-ground wind structure of these storms. It was generally found that storm maximum wind speeds could be increased by up to 30% because of the presence of a topographic feature at the location of maximum wind speeds. Comparing predicted velocity profile amplification with that of a steady flow impinging jet, similar results were found despite the simplifications made in the impinging jet model. Comparison of these amplification profiles with those found in the simulated boundary layer winds reveal reductions of up to 30% in the downburst cases. Downburst and boundary layer amplification profiles were shown to become more similar as the topographic feature height was reduced with respect to the outflow depth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One-dimensional ZnO nanostructures were successfully synthesized on single-crystal silicon substrates via a simple thermal evaporation and vapour-phase transport method under different process temperatures from 500 to 1000 °C. The detailed and in-depth analysis of the experimental results shows that the growth of ZnO nanostructures at process temperatures of 500, 800, and 1000 °C is governed by different growth mechanisms. At a low process temperature of 500 °C, the ZnO nanostructures feature flat and smooth tips, and their growth is primarily governed by the vapour-solid mechanism. At an intermediate process temperature of 800 °C, the ZnO nanostructures feature cone-shape tips, and their growth is primarily governed by the self-catalyzed and saturated vapour–liquid–solid mechanism. At a high process temperature of 1000 °C, the alloy tip appears on the front side of the ZnO nanostructures, and their growth is primarily governed by the common catalyst-assisted vapour–liquid–solid mechanism. It is also shown that the morphological, structural, optical, and compositional properties of the synthesized ZnO nanostructures are closely related to the process temperature. These results are highly relevant to the development of light-emitting diodes, chemical sensors, energy conversion devices, and other advanced applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Catalytic probes are used for plasma diagnostics in order to quantify the density of neutral atoms. The probe response primarily depends on the probe material and its surface morphology. Here we report on the design, operation and modelling of the response of niobium pentoxide sensors with a flat and nanowire (NW) surfaces. These sensors were used to detect neutral oxygen atoms in the afterglow region of an inductively coupled rf discharge in oxygen. A very different response of the flat-surface and NW probes to the varying densities of oxygen atoms was explained by modelling heat conduction and taking into account the associated temperature gradients. It was found that the nanostructure probe can measure in a broader range than the flat oxide probe due to an increase in the surface to volume ratio, and the presence of nanostructures which act as a thermal barrier against sensor overheating. These results can be used for the development of the new generation of catalytic probes for gas/discharge diagnostics in a range of industrial and environmental applications.