85 resultados para cogumelo medicinal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcutaneous immunization (TCI) involves the direct application of antigen plus adjuvant to skin, taking advantage of the large numbers of Langerhans cells and other resident skin dendritic cells, that process antigen then migrate to draining lymph nodes where immune responses are initiated. We have used this form of immunization to protect mice against genital tract and respiratory tract chlamydial infection. Protection was associated with local antibody responses in the vagina, uterus and lung as well as strong Th1 responses in the lymph nodes draining the reproductive tract and lungs respectively. In this study we show that topical application of GM-CSF to skin enhances the numbers and activation status of epidermal dendritic cells. Topical application of GM-CSF also increased the immune responses elicited by TCI. GM-CSF supplementation greatly increased cytokine (IFNgamma and IL-4) gene expression in lymph node and splenic cells compared to cells from animals immunized without GM-CSF. IgG responses in serum, uterine lavage and bronchoalveolar lavage and IgA responses in vaginal lavage were also increased by topical application of GM-CSF. The studies show that TCI induces protection against genital and respiratory tract chlamydial infections and that topical application of cytokines such as GM-CSF can enhance TCI-induced antibody and cell-mediated immunity.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We examine the test-retest reliability of biceps brachii tissue oxygenation index (TOI) parameters measured by near-infrared spectroscopy during a 10-s sustained and a 30-repeated (1-s contraction, 1-s relaxation) isometric contraction task at 30% of maximal voluntary contraction (30% MVC) and maximal (100% MVC) intensities. Eight healthy men (23 to 33 yr) were tested on three sessions separated by 3 h and 24 h, and the within-subject reliability of torque and each TOI parameter were determined by Bland-Altman+/-2 SD limits of agreement plots and coefficient of variation (CV). No significant (P>0.05) differences between the three sessions were found for mean values of torque and TOI parameters during the sustained and repeated tasks at both contraction intensities. All TOI parameters were within+/-2 SD limits of agreement. The CVs for torque integral were similar between the sustained and repeated task at both intensities (4 to 7%); however, the CVs for TOI parameters during the sustained and repeated task were lower for 100% MVC (7 to 11%) than for 30% MVC (22 to 36%). It is concluded that the reliability of the biceps brachii NIRS parameters during both sustained and repeated isometric contraction tasks is acceptable.