70 resultados para Ward, Artemas--1727-1800


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports on an empirically based study of the Queensland (Australia) health and fitness industry over 15 years (1993 -2008). This study traces the development of the new occupation of fitness instructor in a service industry which has evolved si nce the 1980s and is embedded in values of consumption and individualism. It is the new world of work. The data from the 1993 study was historically significant, capturing the conditions o f employment in an unregulated setting prior to the introduction of the first industrial a ward in that industry in 1994. Fitness workers bargained directly with employers over all a spects of the employment relationship without the constraints of industrial regulation or the presence of trade unions. The substantive outcomes of the employment relationship were a direct reflection of m anagerial prerogative and worker orientation and preference, and did not reflect the rewards and outcomes traditionally found in Australian workplaces. While the focus of the 1993 research was on exploring the employment relationship in a deregulated environment, an unusual phenomenon was identified: fitness workers happily trading-off what would be considere d standard working conditions for the opportunity to work (‘take the stage’). Since then, several streams of literature have evolved providing a new context for understanding this phenomenon in the fitness industry, including: the sociology of the body (Shilling 1993; Turner 1996); emotional (Hochschild 1984) and aesthetic labour (Warhurst et al 2000); the so cial relations of production and space (Lefebvre 1991; Moss 1995); body history (Helps 2007); the sociology of consumption (Saunders 1988; Baudrillard 1998; Ritzer 2004); and work identity (Du Gay 1996; Strangleman 2004). The 2008 survey instrument replicated the 1993 study but was additionally informed b y the new literature. Surveys were sent to 310 commercial fitness centres and 4,800 fitness workers across Queensland. Worker orientation appears unchanged, and industry working conditions still seem atypical despite regulation si nce 1994. We argue that for many fitness workers the goal is to gain access to the fitness centre economy. For this they are willing to trade-off standard conditions of employment, and exchange traditional employm ent rewards for m ore intrinsic psycho-social rewards gained the through e xp o sure of their physical capital (Bourdieu 1984) o r bo dily prowess to the adoration o f their gazing clients. Building on the tradition of emotional labour and aesthetic labour, this study introduces the concept of ocularcentric labour: a state in which labour’s quest for the psychosocial rewards gained from their own body image shapes the employment relationship. With ocularcentric labour the p sycho-social rewards have greater value for the worker than ‘hard’, core conditions of employment, and are a significant factor in bargaining and outcomes, often substituting fo r direct earnings. The wo rkforce profile (young, female, casual) and their expectations (psycho-social rewards of ado ration and celebrity) challenge traditional trade unions in terms of what they can deliver, given the fitness workers’ willingness to trade-off minimum conditions, hard-won by unions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To evaluate staff perceptions about working environment, efficiency and the clinical safety of a cardiovascular intervention short stay unit (SSU) during the first year of operation. Design Postal questionnaire. Setting Cardiac catheterisation laboratory (CCL), coronary care unit (CCU), general cardiology ward (GCW) and the short stay unit (SSU) of a tertiary referral hospital situated in the mid coastal region of NSW. Subjects Cardiologists (including visiting medical officers [VMO]), cardiology fellows, cardiology advanced trainees and nurses. Results Responses on the working environment of the SSU and the discharge process were statistically significant. A substantial proportion of both nurses and doctors had concerns about patient safety, even though no adverse events were formally recorded in the database. Conclusions Though the participants of the survey agree on the efficiency of the SSU in providing beds to the hospital, they disagree on aspects that are important in the functioning of the SSU, including the working environment, patient selection and clinical safety. The results highlight potential issues that could be improved or addressed and are relevant to the rollout of SSUs across NSW.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cold-formed steel members have been widely used in residential, industrial and commercial buildings as primary load bearing structural elements and non-load bearing structural elements (partitions) due to their advantages such as higher strength to weight ratio over the other structural materials such as hot-rolled steel, timber and concrete. Cold-formed steel members are often made from thin steel sheets and hence they are more susceptible to various buckling modes. Generally short columns are susceptible to local or distortional buckling while long columns to flexural or flexural-torsional buckling. Fire safety design of building structures is an essential requirement as fire events can cause loss of property and lives. Therefore it is essential to understand the fire performance of light gauge cold-formed steel structures under fire conditions. The buckling behaviour of cold-formed steel compression members under fire conditions is not well investigated yet and hence there is a lack of knowledge on the fire performance of cold-formed steel compression members. Current cold-formed steel design standards do not provide adequate design guidelines for the fire design of cold-formed steel compression members. Therefore a research project based on extensive experimental and numerical studies was undertaken at the Queensland University of Technology to investigate the buckling behaviour of light gauge cold-formed steel compression members under simulated fire conditions. As the first phase of this research, a detailed review was undertaken on the mechanical properties of light gauge cold-formed steels at elevated temperatures and the most reliable predictive models for mechanical properties and stress-strain models based on detailed experimental investigations were identified. Their accuracy was verified experimentally by carrying out a series of tensile coupon tests at ambient and elevated temperatures. As the second phase of this research, local buckling behaviour was investigated based on the experimental and numerical investigations at ambient and elevated temperatures. First a series of 91 local buckling tests was carried out at ambient and elevated temperatures on lipped and unlipped channels made of G250-0.95, G550-0.95, G250-1.95 and G450-1.90 cold-formed steels. Suitable finite element models were then developed to simulate the experimental conditions. These models were converted to ideal finite element models to undertake detailed parametric study. Finally all the ultimate load capacity results for local buckling were compared with the available design methods based on AS/NZS 4600, BS 5950 Part 5, Eurocode 3 Part 1.2 and the direct strength method (DSM), and suitable recommendations were made for the fire design of cold-formed steel compression members subject to local buckling. As the third phase of this research, flexural-torsional buckling behaviour was investigated experimentally and numerically. Two series of 39 flexural-torsional buckling tests were undertaken at ambient and elevated temperatures. The first series consisted 2800 mm long columns of G550-0.95, G250-1.95 and G450-1.90 cold-formed steel lipped channel columns while the second series contained 1800 mm long lipped channel columns of the same steel thickness and strength grades. All the experimental tests were simulated using a suitable finite element model, and the same model was used in a detailed parametric study following validation. Based on the comparison of results from the experimental and parametric studies with the available design methods, suitable design recommendations were made. This thesis presents a detailed description of the experimental and numerical studies undertaken on the mechanical properties and the local and flexural-torsional bucking behaviour of cold-formed steel compression member at ambient and elevated temperatures. It also describes the currently available ambient temperature design methods and their accuracy when used for fire design with appropriately reduced mechanical properties at elevated temperatures. Available fire design methods are also included and their accuracy in predicting the ultimate load capacity at elevated temperatures was investigated. This research has shown that the current ambient temperature design methods are capable of predicting the local and flexural-torsional buckling capacities of cold-formed steel compression members at elevated temperatures with the use of reduced mechanical properties. However, the elevated temperature design method in Eurocode 3 Part 1.2 is overly conservative and hence unsuitable, particularly in the case of flexural-torsional buckling at elevated temperatures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: There are indications that pre-hospital emergency care and management of patients can help reduce the demand for hospital emergency departments (EDs). Ambulance services play a significant role at this stage of care. In 2003, the Queensland Government introduced a Community Ambulance Cover (CAC) levy in return for a free ambulance service at the point of access to all Queenslanders. This may have led to the impression in consumers of an entitlement to free ambulance services under any circumstances regardless of the urgency of the matter which may have in turn contributed to the crowding of EDs in Queensland. Objectives: This paper aims to answer the following questions: - How many patients arrive at hospital EDs by ambulance in Queensland, compared to other modes of arrival? - How has this changed over time, particularly after the CAC introduction in 2003? What percentage of ambulance arrivals are urgent ED patients? - Has the perceived free ambulance services created extra demand for EDs in Queensland, compared with other Australian jurisdictions that charge patients for ambulance services? Methods: We will secondary analyse the data from sources such as Queensland Ambulance Services, Department of Health and Australian Bureau of Statistics to answer the research questions. Findings and Conclusions Queensland has the highest utilization rate of ambulance services (about 18% in 2007-08) and the highest annual growth rate in demand for these services (7.7% on average since 2000-01), well above the population growth. On the other hand, the proportion of ED patients arriving by ambulance in Queensland has increased by about 4% annually. However, when compared with other states and territories with charge at the point of access, it seems that the growth in demand for EDs cannot be explained solely or mainly by CAC or ambulance utilisation in Queensland.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Autistic Behavioural Indicators Instrument (ABII) is an 18-item instrument developed to identify children with Autistic Disorder (AD) based on the presence of unique autistic behavioural indicators. The ABII was administered to 20 children with AD, 20 children with speech and language impairment (SLI) and 20 typically developing (TD) children aged 2-6 years. Results indicated that the ABII discriminated children diagnosed with AD from those diagnosed with SLI and those who were TD, based on the presence of specific social attention, sensory, and behavioural symptoms. A combination of symptomology across these domains correctly classified 100% of children with and without AD. The paper concludes that the ABII shows considerable promise as an instrument for the early identification of AD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rodenticide use in agriculture can lead to the secondary poisoning of avian predators. Currently the Australian sugarcane industry has two rodenticides, Racumin® and Rattoff®, available for in-crop use but, like many agricultural industries, it lacks an ecologically-based method of determining the potential secondary poisoning risk the use of these rodenticides poses to avian predators. The material presented in this thesis addresses this by: a. determining where predator/prey interactions take place in sugar producing districts; b. quantifying the amount of rodenticide available to avian predators and the probability of encounter; and c. developing a stochastic model that allows secondary poisoning risk under various rodenticide application scenarios to be investigated. Results demonstrate that predator/prey interactions are highly constrained by environmental structure. Rodents used crops that provided high levels of canopy cover and therefore predator protection and poorly utilised open canopy areas. In contrast, raptors over-utilised areas with low canopy cover and low rodent densities, but which provided high accessibility to prey. Given this pattern of habitat use, and that industry baiting protocols preclude rodenticide application in open canopy crops, these results indicate that secondary poisoning can only occur if poisoned rodents leave closed canopy crops and become available for predation in open canopy areas. Results further demonstrate that after in-crop rodenticide application, only a small proportion of rodents available in open areas are poisoned and that these rodents carry low levels of toxicant. Coupled with the low level of rodenticide use in the sugar industry, the high toxic threshold raptors have to these toxicants and the low probability of encountering poisoned rodents, results indicate that the risk of secondary poisoning events occurring is minimal. A stochastic model was developed to investigate the effect of manipulating factors that might influence secondary poisoning hazard in a sugarcane agro-ecosystem. These simulations further suggest that in all but extreme scenarios, the risk of secondary poisoning is also minimal. Collectively, these studies demonstrate that secondary poisoning of avian predators associated with the use of the currently available rodenticides in Australian sugar producing districts is minimal. Further, the ecologically-based method of assessing secondary poisoning risk developed in this thesis has broader applications in other agricultural systems where rodenticide use may pose risks to avian predators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Management of acute heart failure is an important consideration in critical care. Mechanical support of the failing heart is crucial for improving health outcomes. The most common Australasian application of intraaortic balloon counterpulsation (IABP) is in the setting of cardiogenic shock. High end users of IABP (>37/annum) demonstrate significantly lower mortality for cardiogenic shock managed with IABP (p <0.001) in contrast to hospitals which employ limited IABP (<4/annum). This underscores the importance of proficiency in managing patient receiving IABP support. Nurses play a crucial role in carding for patients with acute heart failure. This paper summarises care considerations for management of the IABP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the findings of an investigation into the rate-limiting mechanism for the heterogeneous burning in oxygen under normal gravity and microgravity of cylindrical iron rods. The original objective of the work was to determine why the observed melting rate for burning 3.2-mm diameter iron rods is significantly higher in microgravity than in normal gravity. This work, however, also provided fundamental insight into the rate-limiting mechanism for heterogeneous burning. The paper includes a summary of normal-gravity and microgravity experimental results, heat transfer analysis and post-test microanalysis of quenched samples. These results are then used to show that heat transfer across the solid/liquid interface is the rate-limiting mechanism for melting and burning, limited by the interfacial surface area between the molten drop and solid rod. In normal gravity, the work improves the understanding of trends reported during standard flammability testing for metallic materials, such as variations in melting rates between test specimens with the same cross-sectional area but different crosssectional shape. The work also provides insight into the effects of configuration and orientation, leading to an improved application of standard test results in the design of oxygen system components. For microgravity applications, the work enables the development of improved methods for lower cost metallic material flammability testing programs. In these ways, the work provides fundamental insight into the heterogeneous burning process and contributes to improved fire safety for oxygen systems in applications involving both normal-gravity and microgravity environments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a proposed qualitative framework to discuss the heterogeneous burning of metallic materials, through parameters and factors that influence the melting rate of the solid metallic fuel (either in a standard test or in service). During burning, the melting rate is related to the burning rate and is therefore an important parameter for describing and understanding the burning process, especially since the melting rate is commonly recorded during standard flammability testing for metallic materials and is incorporated into many relative flammability ranking schemes. However, whilst the factors that influence melting rate (such as oxygen pressure or specimen diameter) have been well characterized, there is a need for an improved understanding of how these parameters interact as part of the overall melting and burning of the system. Proposed here is the ‘Melting Rate Triangle’, which aims to provide this focus through a conceptual framework for understanding how the melting rate (of solid fuel) is determined and regulated during heterogeneous burning. In the paper, the proposed conceptual model is shown to be both (a) consistent with known trends and previously observed results, and (b)capable of being expanded to incorporate new data. Also shown are examples of how the Melting Rate Triangle can improve the interpretation of flammability test results. Slusser and Miller previously published an ‘Extended Fire Triangle’ as a useful conceptual model of ignition and the factors affecting ignition, providing industry with a framework for discussion. In this paper it is shown that a ‘Melting Rate Triangle’ provides a similar qualitative framework for burning, leading to an improved understanding of the factors affecting fire propagation and extinguishment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper examines the patterns of television news coverage of the political parties, their leaders and the issues they raised during the 2001 Australian federal election campaign. By focusing on some issues, parties and leaders, television has long been argued to constrain voters' evaluations. We find that television news coverage in the 2001 Australian election campaign focused primarily on international issues, especially terrorism and asylum seekers, and on the two major parties - virtually to the exclusion of coverage of the minor parties and their leaders. Within the major party 'two-horse race', television gave substantially more coverage to the leaders than to the parties themselves, thereby sustaining what some have called a 'presidential'-style political contest. John Howard emerged as the winner in the leaders' stakes, garnering more coverage than Labor's Kim Beazley.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The macerals in bituminous coals with varying organic sulfur content from the Early Permian Greta Coal Measures at three locations (Southland Colliery, Drayton Colliery and the Cranky Corner Basin), in and around the Sydney Basin (Australia), have been studied using light-element electron microprobe (EMP) analysis and micro-ATR–FTIR. Electron microprobe analysis of individual macerals reveals that the vitrinite in both the Cranky Corner Basin and Drayton Colliery (Puxtrees seam) samples have similar carbon contents (ca. 78% C in telocollinite), suggesting that they are of equivalent rank. However, the Cranky Corner coals have anomalously low vitrinite reflectance (down to 0.45%) vs. the Drayton materials (ca. 0.7%). They also have very high organic S content (3–6.5%) and lower O content (ca. 10%) than the equivalent macerals in the Drayton sample (0.7% S and 15.6% O). A study was carried out to investigate the impacts of the high organic S on the functional groups of the macerals in these two otherwise iso-rank, stratigraphically-equivalent seams. An iso-rank low-S coal from the overlying Wittingham Coal Measures near Muswellbrook and coals of slightly higher rank from the Greta Coal Measures at Southland Colliery near Cessnock were also evaluated using the same techniques to extend the data set. Although the telocollinite in the Drayton and Cranky Corner coals have very similar carbon content (ca.78% C), the ATR–FTIR spectra of the vitrinite and inertinite macerals in these respectively low S and high S coals show some distinct differences in IR absorbance from various aliphatic and aromatic functional groups. The differences in absorbance of the aliphatic stretching bands (2800–3000 cm−1) and the aromatic carbon (CC) peak at 1606 cm−1 are very obvious. Compared to that of the Drayton sample (0.7% S and 15% O), the telocollinite of the Cranky Corner coal (6% S and 10% O) clearly shows: (i) less absorbance from OH groups, represented by a broad region around 3553 cm−1, (ii) much stronger aliphatic C–H absorbance (stretching modes around 3000–2800 cm−1 and bending modes around 1442 cm−1) and (iii) less absorbance from aromatic carbon functional groups (peaking at 1606 cm−1). Evaluation of the iso-rank Drayton and Cranky Corner coals shows that: (i) the aliphatic C–H absorbances decrease with increasing oxygen content but increase with increasing organic S content and (ii) the aromatic H to aliphatic H ratio (Har/Hali) for the telocollinite increases with (organic) O%, but decreases progressively with increasing organic S. The high organic S content in the maceral appears to be accompanied by a greater proportion of aliphatic functional groups, possibly as a result of some of the O within maceral ring structures in the high S coal samples being replaced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is a report of a study to explore what constitutes nurse-patient interactions and to ascertain patients' perceptions of these interactions. BACKGROUND: Nurses maintain patient integrity through caring practices. When patients feel disempowered or that their integrity is threatened they are more likely to make a complaint. When nurses develop a meaningful relationship with patients they recognize and address their concerns. It is increasingly identified in the literature that bureaucratic demands, including increased workloads and reduced staffing levels, result in situations where the development of a 'close' relationship is limited. METHOD: Data collection took two forms: twelve 4-hour observation periods of nurse-patient interactions in one cubicle (of four patients) in a medical and a surgical ward concurrently over a 4-week period; and questionnaires from inpatients of the two wards who were discharged during the 4-week data collection period in 2005. FINDINGS: Observation data showed that nurse-patient interactions were mostly friendly and informative. Opportunities to develop closeness were limited. Patients were mostly satisfied with interactions. The major source of dissatisfaction was when patients perceived that nurses were not readily available to respond to specific requests. Comparison of the observation and survey data indicated that patients still felt 'cared for' even when practices did not culminate in a 'connected' relationship. CONCLUSION: The findings suggest that patients believe that caring is demonstrated when nurses respond to specific requests. Patient satisfaction with the service is more likely to be improved if nurses can readily adapt their work to accommodate patients' requests or, alternatively, communicate why these requests cannot be immediately addressed.