32 resultados para Tales--Iran--Early works to 1800


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: An early response to antipsychotic treatment in patients with psychosis has been associated with a better course and outcome. However, factors that predict treatment response are not well understood. The onset of schizophrenia and related disorders has been associated with increased levels of stress and hyper-activation of the hypothalamic-pituitary-adrenal (HPA) axis. This study examined whether pituitary volume at the onset of psychosis may be a potential predictor of early treatment response in first-episode psychosis (FEP) patients. METHODS: We investigated the relationship between baseline pituitary volume and symptomatic treatment response over 12 weeks using mixed model analysis in a sample of 42 drug-naïve or early treated FEP patients who participated in a controlled dose-finding study of quetiapine fumarate. Logistic regression was used to examine predictors of treatment response. Pituitary volume was measured from magnetic resonance imaging scans that were obtained upon entry into the trial. RESULTS: Larger pituitary volume was associated with less improvement in overall psychotic symptoms (Brief Psychiatric Rating Scale (BPRS) P=0.031) and positive symptoms (BPRS positive symptom subscale P=0.010). Regardless of gender, patients with a pituitary volume at the 25th percentile (413 mm(3)) were approximately three times more likely to respond to treatment by week 12 than those at the 75th percentile (635 mm(3)) (odds ratio=3.07, CI: 0.90-10.48). CONCLUSION: The association of baseline pituitary volumes with early treatment response highlights the importance of the HPA axis in emerging psychosis. Potential implications for treatment strategies in early psychosis are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The responses of composite buildings under wind loads clearly become more critical as the building becomes taller, less stiff and more lightweight. When the composite building increases in height, the stiffness of the structure becomes more important factor and introduction to belt truss and outrigger system is often used to provide sufficient lateral stiffness to the structure. Most of the research works to date is limited to reinforced concrete building with outrigger system of concrete structure, simple building plan layout, single height of a building, one direction wind and single level of outrigger arrangement. There is a scarcity in research works about the effective position of outrigger level on composite buildings under lateral wind loadings when the building plan layout, height and outrigger arrangement are varied. The aim of this paper is to determine the optimum location of steel belt and outrigger systems by using different arrangement of single and double level outrigger for different size, shape and height of composite building. In this study a comprehensive finite element modelling of composite building prototypes is carried out, with three different layouts (Rectangular, Octagonal and L shaped) and for three different storey (28, 42 and 57-storey). Models are analysed for dynamic cyclonic wind loads with various combination of steel belt and outrigger bracings. It is concluded that the effectiveness of the single and double level steel belt and outrigger bracing are varied based on their positions for different size, shape and height of composite building.