50 resultados para TAP


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patient-centred care has been touted as the cornerstone of an effective and efficient primary health care system. However, primary care by its nature is a fragmented system. The system co-evolves in response to needs rather than being planned. In recent years, Medicare Locals were formed in Australia with the intention to tap into this pragmatic nature of primary care and foster health services delivery which is responsive to community and individual patient needs i.e. ‘patient-centred care’. However, it remains to be seen what and how theoretical framework/s can inform this work. For this presentation we aim to illustrate with a case study how hepatitis C is currently managed in primary care and hypothesise what a congruent model of patient-centred care for hepatitis C management could look like.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The IEC 61850 family of standards for substation communication systems were released in the early 2000s, and include IEC 61850-8-1 and IEC 61850-9-2 that enable Ethernet to be used for process-level connections between transmission substation switchyards and control rooms. This paper presents an investigation of process bus protection performance, as the in-service behavior of multi-function process buses is largely unknown. An experimental approach was adopted that used a Real Time Digital Simulator and 'live' substation automation devices. The effect of sampling synchronization error and network traffic on transformer differential protection performance was assessed and compared to conventional hard-wired connections. Ethernet was used for all sampled value measurements, circuit breaker tripping, transformer tap-changer position reports and Precision Time Protocol synchronization of sampled value merging unit sampling. Test results showed that the protection relay under investigation operated correctly with process bus network traffic approaching 100% capacity. The protection system was not adversely affected by synchronizing errors significantly larger than the standards permit, suggesting these requirements may be overly conservative. This 'closed loop' approach, using substation automation hardware, validated the operation of protection relays under extreme conditions. Digital connections using a single shared Ethernet network outperformed conventional hard-wired solutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Integration of small-scale electricity generators, known as Distributed Generation (DG), into the distribution networks has become increasingly popular at the present. This tendency together with the falling price of synchronous-type generator has potential to give the DG a better chance in participating in the voltage regulation process together with other devices already available in the system. The voltage control issue turns out to be a very challenging problem for the distribution engineers since existing control coordination schemes would need to be reconsidered to take into account the DG operation. In this paper, we propose a control coordination technique, which is able to utilize the ability of the DG as a voltage regulator, and at the same time minimizes interaction with other active devices, such as On-load Tap Changing Transformer (OLTC) and voltage regulator. The technique has been developed based on the concept of control zone, Line Drop Compensation (LDC), as well as the choice of controller's parameters. Simulations carried out on an Australian system show that the technique is suitable and flexible for any system with multiple regulating devices including DG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis presents social requirements and design considerations from a study evaluating interactive approaches to social navigation and user-generated information sharing in urban environments using mobile devices. It investigates innovative ways to leverage mobile information and communication technology in order to provide a social navigation platform for residents and visitors in and for public urban places. Through a design case study this work presents CityFlocks, a mobile information system that offers an easy way for information-seeking new residents or visitors to access tacit knowledge from local people about their new community. It is intended to enable visitors and new residents in a city to tap into the knowledge and experiences of local residents in order to gather information about their new environment. Its design specifically aims to lower existing barriers of access and facilitate social navigation in urban places. In various user tests it evaluates two general user interaction alternatives – direct and indirect social navigation – and analyses which interaction method works better for people using a mobile device to socially navigate urban environments. The outcomes are relevant for the user interaction design of future mobile information systems that leverage the social navigation approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using our porcine model of deep dermal partial thickness burn injury, various cooling techniques (15 degrees C running water, 2 degrees C running water, ice) of first aid were applied for 20 minutes compared with a control (ambient temperature). The subdermal temperatures were monitored during the treatment and wounds observed and photographed weekly for 6 weeks, observing reepithelialization, wound surface area and cosmetic appearance. Tissue histology and scar tensile strength were examined 6 weeks after burn. The 2 degrees C and ice treatments decreased the subdermal temperature the fastest and lowest, however, generally the 15 and 2 degrees C treated wounds had better outcomes in terms of reepithelialization, scar histology, and scar appearance. These findings provide evidence to support the current first aid guidelines of cold tap water (approximately 15 degrees C) for 20 minutes as being beneficial in helping to heal the burn wound. Colder water at 2 degrees C is also beneficial. Ice should not be used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Throughout history there have been many different and sometimes bizarre treatments prescribed for burns. Unfortunately many of these treatments still persist today, although they often do not have sufficient evidence to support their use. This paper reviews common first aid and pre-hospital treatments for burns (water--cold or warm, ice, oils, powders and natural plant therapies), possible mechanisms whereby they might work and the literature which supports their use. From the published work to date, the current recommendations for the first aid treatment of burn injuries should be to use cold running tap water (between 2 and 15 degrees C) on the burn, not ice or alternative plant therapies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Single phase distributed energy resources (DERs) can cause voltage rise along distribution feeder and power imbalance among the phases. Usually transformer tap setting are used to mitigate voltage drop along feeders. However this can aggravate the voltage rise problem when DERs are connected. Moreover if the power generation in a phase is more than its load demand, the excess power in that phase will be fed back to the transmission network. In this paper, a unified power quality compensator (UPQC) has been utilized to alleviate the voltage quality excess power circulation problems. Through analysis and simulation results, the mode of operation of UPQC is highlighted. The proposals are validated through extensive digital computer simulation studies using PSCAD and MATLAB.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new hybrid evolutionary algorithm based on Particle Swarm Optimization (PSO) and Ant Colony Optimization (ACO) for daily Volt/Var control in distribution system including Distributed Generators (DGs). Due to the small X/R ratio and radial configuration of distribution systems, DGs have much impact on this problem. Since DGs are independent power producers or private ownership, a price based methodology is proposed as a proper signal to encourage owners of DGs in active power generation. Generally, the daily Volt/Var control is a nonlinear optimization problem. Therefore, an efficient hybrid evolutionary method based on Particle Swarm Optimization and Ant Colony Optimization (ACO), called HPSO, is proposed to determine the active power values of DGs, reactive power values of capacitors and tap positions of transformers for the next day. The feasibility of the proposed algorithm is demonstrated and compared with methods based on the original PSO, ACO and GA algorithms on IEEE 34-bus distribution feeder.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Organizations invest in ways to stimulate new ideas for new products and services for the benefit of the organization, engaging in tournaments and competitions to generate new ideas or to combine existing ideas in new ways for new products and services (Terweisch and Uhlrich, 2009). Specifically, some large companies have developed platforms for posting intractable problems to tap into the ideas and problem solving abilities of a broader range of people (Huston and Sakkab, 2006; Morgan and Wang, 2010), and to develop new and elegant solutions often in an open innovation approach (Chesbrough, 2003). The notion of ingenuity is often applied to individuals who create innovative solutions in situations of constraint, where ingenuity in the form of elegant solutions can be understood as one form of resourcefulness (Young, 2011). However, the notion of organizational ingenuity locates ingenuity more centrally to an organization's strategic decision making and implementation, embedding ingenuity into the company's culture. Studies of organizations displaying ingenuity indicate a range of possibilities from extreme ingenuity (Baker and Nelson, 2005) to less dramatic but substantial changes (Thomke, 2003), sometimes in an experimental phase or as part of a move towards a new and distinct identity for ongoing innovation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose This paper describes the implementation and evaluation of an intervention aimed at increasing the dog-walking behaviour of residents from a community of approximately 60,000. This intervention was a sub strategy of the 10 000 Steps Rockhampton project – a community intervention aimed at decreasing sedentary behaviour in the adult population. Methods Brochures and posters were developed that promoted dog walking as a means to improve both human and canine health. The brochures were distributed by the local council to over 8 000 homes with the annual dog-renewal registrations. Results Evaluation of the intervention included a telephone survey of a randomly selected sample of Rockhampton residents (n=420) four-months post intervention. Although 63.6% of participants reported that owning a dog increased their physical activity levels, 40% of dog-owners did not walk their dog at all in the last week. The outcome evaluation of the intervention showed that 20.2% of dog-owners recalled receiving the brochure. Overall 15.3% of respondents with a dog in their household reported an increase in their physical activity levels since the intervention, 8.4% reported a decrease. Conclusions The intervention was an innovative and cost-effective way to tap into a section of the population that can benefit from engaging in regular walking behaviour. It was also a unique and useful way to engage local council in physical activity health promotion as part of a larger ongoing community-wide intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, integration of small-scale electricity generators, known as Distributed Generation (DG), into distribution networks has become increasingly popular. This tendency together with the falling price of DG units has a great potential in giving the DG a better chance to participate in voltage regulation process, in parallel with other regulating devices already available in the distribution systems. The voltage control issue turns out to be a very challenging problem for distribution engineers, since existing control coordination schemes need to be reconsidered to take into account the DG operation. In this paper, a control coordination approach is proposed, which is able to utilize the ability of the DG as a voltage regulator, and at the same time minimize the interaction of DG with another DG or other active devices, such as On-load Tap Changing Transformer (OLTC). The proposed technique has been developed based on the concepts of protection principles (magnitude grading and time grading) for response coordination of DG and other regulating devices and uses Advanced Line Drop Compensators (ALDCs) for implementation. A distribution feeder with tap changing transformer and DG units has been extracted from a practical system to test the proposed control technique. The results show that the proposed method provides an effective solution for coordination of DG with another DG or voltage regulating devices and the integration of protection principles has considerably reduced the control interaction to achieve the desired voltage correction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective Research into youth caregiving in families where a parent experiences a significant medical condition has been hampered by a lack of contextually sensitive measures of the nature and breadth of young caregiving experiences. This study examined the factor structure and measurement invariance of such a measure called the Young Carer of Parents Inventory (YCOPI; Pakenham et al., 2006) using confirmatory factor analysis across 3 groups of youth. The YCOPI has 2 parts: YCOPI-A with 5 factors assessing caregiving experiences that are applicable to all caregiving contexts; YCOPI-B with 4 factors that tap dimensions related to youth caregiving in the context of parent illness. Design Two samples (ages 9–20 years) were recruited: a community sample of 2,429 youth from which 2 groups were derived (“healthy” family [HF], n = 1760; parental illness [PI], n = 446), and a sample of 130 youth of a parent with multiple sclerosis). Results With some modification, the YCOPI-A demonstrated a replicable factor structure across 3 groups, and exhibited only partial measurement invariance across the HF and PI groups. The impact of assuming full measurement invariance on latent mean differences appeared small, supporting use of the measure in research and applied settings when estimated using latent factors and controlling for measurement invariance. PI youth reported significantly higher scores than did HF youth on all YCOPI-A subscales. The YCOPI-B requires some modifications, and further development work is recommended. Conclusion The factor structure that emerged and the addition of new items constitutes the YCOPI-Revised. Findings support the use of the YCOPI-Revised in research and applied settings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The expression of biomass-degrading enzymes (such as cellobiohydrolases) in transgenic plants has the potential to reduce the costs of biomass saccharification by providing a source of enzymes to supplement commercial cellulase mixtures. Cellobiohydrolases are the main enzymes in commercial cellulase mixtures. In the present study, a cellobiohydrolase was expressed in transgenic corn stover leaf and assessed as an additive for two commercial cellulase mixtures for the saccharification of pretreated sugar cane bagasse obtained by different processes. Results Recombinant cellobiohydrolase in the senescent leaves of transgenic corn was extracted using a simple buffer with no concentration step. The extract significantly enhanced the performance of Celluclast 1.5 L (a commercial cellulase mixture) by up to fourfold on sugar cane bagasse pretreated at the pilot scale using a dilute sulfuric acid steam explosion process compared to the commercial cellulase mixture on its own. Also, the extracts were able to enhance the performance of Cellic CTec2 (a commercial cellulase mixture) up to fourfold on a range of residues from sugar cane bagasse pretreated at the laboratory (using acidified ethylene carbonate/ethylene glycol, 1-butyl-3-methylimidazolium chloride, and ball-milling) and pilot (dilute sodium hydroxide and glycerol/hydrochloric acid steam explosion) scales. We have demonstrated using tap water as a solvent (under conditions that mimic an industrial process) extraction of about 90% recombinant cellobiohydrolase from senescent, transgenic corn stover leaf that had minimal tissue disruption. Conclusions The accumulation of recombinant cellobiohydrolase in senescent, transgenic corn stover leaf is a viable strategy to reduce the saccharification cost associated with the production of fermentable sugars from pretreated biomass. We envisage an industrial-scale process in which transgenic plants provide both fibre and biomass-degrading enzymes for pretreatment and enzymatic hydrolysis, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Integration of small-scale electricity generators, known as distributed generation (DG), into the distribution networks has become increasingly popular at the present. This tendency together with the falling price of the synchronous-type generator has potential to give DG a better chance at participating in the voltage regulation process together with other devices already available in the system. The voltage control issue turns out to be a very challenging problem for the distribution engineers since existing control coordination schemes would need to be reconsidered to take into account the DG operation. In this paper, we propose a control coordination technique, which is able to utilize the ability of DG as a voltage regulator and, at the same time, minimize interaction with other active devices, such as an on-load tap changing transformer and a voltage regulator. The technique has been developed based on the concept of control zone, line drop compensation, dead band, as well as the choice of controllers' parameters. Simulations carried out on an Australian system show that the technique is suitable and flexible for any system with multiple regulating devices including DG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work is a MATLAB/Simulink model of a controller for a three-phase, four-wire, grid-interactive inverter. The model provides capacity for simulating the performance of power electroinic hardware, as well as code generation for an embedded controller. The implemented hardware topology is a three-leg bridge with a neutral connection to the centre-tap of the DC bus. An LQR-based current controller and MAF-based phase detector are implemented. The model is configured for code generation for a Texas Instruments TMS320F28335 Digital Signal Processor (DSP).