168 resultados para Outcome results


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Early to mid-term fetuses heal cutaneous incisional wounds without scars; however, fetal response to burn injury has not been ascertained. We present a fetal model of thermal injury and subsequent analysis of fetal and lamb response to burn injury. A reproducible deep dermal burn injury was created in the fetus by application of water at 66 degrees C for 7 seconds, and at 82 degrees C for 10 seconds to the lamb. Macroscopically, the area of fetal scald was undetectable from day 7 post injury, while all lamb scalds were readily identified and eventually healed with scarring. Using a five-point histopathology scoring system for alteration in tissue morphology, differences were detected between control and scalded skin at all stages in lamb postburn, but no difference was detected in the fetal model after day 7. There were also large differences in content of alpha-smooth muscle actin and transforming growth factor-beta1 between control and scalded lamb and these differences were statistically significant at day 14 (P < 0.01). This novel model of fetal and lamb response to deep dermal injury indicates that the fetus heals a deep burn injury in a scarless fashion. Further elucidation of this specific fetal process of burn injury repair may lead to improved outcome for patients with burn injury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to explore whether participants' pretherapy coping strategies predicted the outcome of group cognitive behavioral therapy (CBT) for anxiety and depression. It was hypothesized that adaptive coping strategies such as the use of active planning and acceptance would be associated with higher reductions, whereas maladaptive coping strategies such as denial and disengagement would be associated with lower reductions in anxious and depressed symptoms following psychotherapy. There were 144 participants who completed group CBT for anxiety and depression. Measures of coping strategies were administered prior to therapy, whereas measures of depression and anxiety were completed both prior to and following therapy. The results showed that higher levels of denial were associated with a poorer outcome, in terms of change in anxiety but not depression, following therapy. These findings suggest the usefulness of using the Denial subscale from the revised Coping Orientation to Problems Experienced (COPE) as a predictor of outcome in group CBT for anxiety.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Lower extremities are particularly susceptible to injury in an under‐vehicle explosion. Operational fitness of military vehicles is assessed through anthropometric test devices (ATDs) in full‐scale blast tests. The aim of this study was to compare the response between the Hybrid‐III ATD, the MiL‐Lx ATD and cadavers in our traumatic injury simulator, which is able to replicate the response of the vehicle floor in an under‐vehicle explosion. All specimens were fitted with a combat boot and tested on our traumatic injury simulator in a seated position. The load recorded in the ATDs was above the tolerance levels recommended by NATO in all tests; no injuries were observed in any of the 3 cadaveric specimens. The Hybrid‐III produced higher peak forces than the MiL‐Lx. The time to peak strain in the calcaneus of the cadavers was similar to the time to peak force in the ATDs. Maximum compression of the sole of the combat boot was similar for cadavers and MiL‐Lx, but significantly greater for the Hybrid‐III. These results suggest that the MiL‐Lx has a more biofidelic response to under‐vehicle explosive events compared to the Hybrid‐III. Therefore, it is recommended that mitigation strategies are assessed using the MiL‐Lx surrogate and not the Hybrid‐III.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Despite the commonality of cough and its burden, there are no published data on the relationship between atopy or sex on objectively measured cough frequency or subjective cough scores in children. In 202 children with and without cough, we determined the effect of sex and atopy on validated cough outcome measurements (cough receptor sensitivity [CRS], objective cough counts, and cough scores). We hypothesized that in contrast to adult data, sex does not influence cough outcome measures, and atopy is not a determinant of these cough measurements. Methods We combined data from four previous studies. Atopy (skin prick test), the concentration of capsaicin causing two and five or more coughs (C2 and C5, respectively), objectively measured cough frequency, and cough scores were determined and their relationship explored. The children’s (93 girls, 109 boys) mean age was 10.6 years (SD 2.9), and 56% had atopy. Results In multivariate analysis, CRS was influenced by age (C2 coefficient, 5.9; P = .034; C5 coefficient, 29.1; P = .0001). Atopy and sex did not significantly influence any of the cough outcomes (cough counts, C2, C5, cough score) in control subjects and children with cough. Conclusions Atopy does not influence important cough outcome measures in children with and without chronic cough. However, age, but not sex, influences CRS in children. Unlike adult data, sex does not affect objective counts or cough score in children with and without chronic cough. Studies on cough in children should be age matched, but matching for atopic status and sex is less important.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Accelerometers are recognized as a valid and objective tool to assess free-living physical activity. Despite the widespread use of accelerometers, there is no standardized way to process and summarize data from them, which limits our ability to compare results across studies. This paper a) reviews decision rules researchers have used in the past, b) compares the impact of using different decision rules on a common data set, and c) identifies issues to consider for accelerometer data reduction. Methods The methods sections of studies published in 2003 and 2004 were reviewed to determine what decision rules previous researchers have used to identify wearing period, minimal wear requirement for a valid day, spurious data, number of days used to calculate the outcome variables, and extract bouts of moderate to vigorous physical activity (MVPA). For this study, four data reduction algorithms that employ different decision rules were used to analyze the same data set. Results The review showed that among studies that reported their decision rules, much variability was observed. Overall, the analyses suggested that using different algorithms impacted several important outcome variables. The most stringent algorithm yielded significantly lower wearing time, the lowest activity counts per minute and counts per day, and fewer minutes of MVPA per day. An exploratory sensitivity analysis revealed that the most stringent inclusion criterion had an impact on sample size and wearing time, which in turn affected many outcome variables. Conclusions These findings suggest that the decision rules employed to process accelerometer data have a significant impact on important outcome variables. Until guidelines are developed, it will remain difficult to compare findings across studies

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The general aim of designated driver programs is to reduce the level of drink driving by encouraging potential drink drivers to travel with a driver who has abstained from (or at least limited) consuming alcohol. Designated driver programs appear to be quite widespread around the world, however a limited number have been subject to rigorous evaluation. This paper reports results from an outcome evaluation of a designated driver program called ‘Skipper’, which was trialled in a provincial city in Queensland, Australia. The outcome evaluation included surveys three weeks prior to (baseline), four months following (1st follow-up), and 16 months following (2nd follow-up) the commencement of the trial in both the ‘intervention area’ (baseline, n = 202; 1st follow-up, n = 211; 2nd follow-up, n = 200) and a ‘comparison area’(baseline, n = 203; 1st follow-up, n = 199; 2nd follow-up, n = 201); and a comparison of random breath testing and crash data before and after the trial. The survey results indicate that awareness of the program in the intervention area was quite high four months following its introduction and that this was maintained at 16 months. The results also suggest that the ‘Skipper’ program and the related publicity had positive impacts on behaviour with an increase in the proportion of people participating in designated driver as a passenger. It is less clear, however, whether the ‘Skipper’ program impacted on other behaviours of interest, such as drink driving or involvement in alcohol-related crashes. Suggestions for further research and program improvement are discussed as well as limitations of the research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Monitoring gases for environmental, industrial and agricultural fields is a demanding task that requires long periods of observation, large quantity of sensors, data management, high temporal and spatial resolution, long term stability, recalibration procedures, computational resources, and energy availability. Wireless Sensor Networks (WSNs) and Unmanned Aerial Vehicles (UAVs) are currently representing the best alternative to monitor large, remote, and difficult access areas, as these technologies have the possibility of carrying specialised gas sensing systems, and offer the possibility of geo-located and time stamp samples. However, these technologies are not fully functional for scientific and commercial applications as their development and availability is limited by a number of factors: the cost of sensors required to cover large areas, their stability over long periods, their power consumption, and the weight of the system to be used on small UAVs. Energy availability is a serious challenge when WSN are deployed in remote areas with difficult access to the grid, while small UAVs are limited by the energy in their reservoir tank or batteries. Another important challenge is the management of data produced by the sensor nodes, requiring large amount of resources to be stored, analysed and displayed after long periods of operation. In response to these challenges, this research proposes the following solutions aiming to improve the availability and development of these technologies for gas sensing monitoring: first, the integration of WSNs and UAVs for environmental gas sensing in order to monitor large volumes at ground and aerial levels with a minimum of sensor nodes for an effective 3D monitoring; second, the use of solar energy as a main power source to allow continuous monitoring; and lastly, the creation of a data management platform to store, analyse and share the information with operators and external users. The principal outcomes of this research are the creation of a gas sensing system suitable for monitoring any kind of gas, which has been installed and tested on CH4 and CO2 in a sensor network (WSN) and on a UAV. The use of the same gas sensing system in a WSN and a UAV reduces significantly the complexity and cost of the application as it allows: a) the standardisation of the signal acquisition and data processing, thereby reducing the required computational resources; b) the standardisation of calibration and operational procedures, reducing systematic errors and complexity; c) the reduction of the weight and energy consumption, leading to an improved power management and weight balance in the case of UAVs; d) the simplification of the sensor node architecture, which is easily replicated in all the nodes. I evaluated two different sensor modules by laboratory, bench, and field tests: a non-dispersive infrared module (NDIR) and a metal-oxide resistive nano-sensor module (MOX nano-sensor). The tests revealed advantages and disadvantages of the two modules when used for static nodes at the ground level and mobile nodes on-board a UAV. Commercial NDIR modules for CO2 have been successfully tested and evaluated in the WSN and on board of the UAV. Their advantage is the precision and stability, but their application is limited to a few gases. The advantages of the MOX nano-sensors are the small size, low weight, low power consumption and their sensitivity to a broad range of gases. However, selectivity is still a concern that needs to be addressed with further studies. An electronic board to interface sensors in a large range of resistivity was successfully designed, created and adapted to operate on ground nodes and on-board UAV. The WSN and UAV created were powered with solar energy in order to facilitate outdoor deployment, data collection and continuous monitoring over large and remote volumes. The gas sensing, solar power, transmission and data management systems of the WSN and UAV were fully evaluated by laboratory, bench and field testing. The methodology created to design, developed, integrate and test these systems was extensively described and experimentally validated. The sampling and transmission capabilities of the WSN and UAV were successfully tested in an emulated mission involving the detection and measurement of CO2 concentrations in a field coming from a contaminant source; the data collected during the mission was transmitted in real time to a central node for data analysis and 3D mapping of the target gas. The major outcome of this research is the accomplishment of the first flight mission, never reported before in the literature, of a solar powered UAV equipped with a CO2 sensing system in conjunction with a network of ground sensor nodes for an effective 3D monitoring of the target gas. A data management platform was created using an external internet server, which manages, stores, and shares the data collected in two web pages, showing statistics and static graph images for internal and external users as requested. The system was bench tested with real data produced by the sensor nodes and the architecture of the platform was widely described and illustrated in order to provide guidance and support on how to replicate the system. In conclusion, the overall results of the project provide guidance on how to create a gas sensing system integrating WSNs and UAVs, how to power the system with solar energy and manage the data produced by the sensor nodes. This system can be used in a wide range of outdoor applications, especially in agriculture, bushfires, mining studies, zoology, and botanical studies opening the way to an ubiquitous low cost environmental monitoring, which may help to decrease our carbon footprint and to improve the health of the planet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Design Delphi panel and cohort study. Objective To develop and refine a condition-specific, patient-reported outcome measure, the Ankle Fracture Outcome of Rehabilitation Measure (A-FORM), and to examine its psychometric properties, including factor structure, reliability, and validity, by assessing item fit with the Rasch model. Background To our knowledge, there is no patient-reported outcome measure specific to ankle fracture with a robust content foundation. Methods A 2-stage research design was implemented. First, a Delphi panel that included patients and health professionals developed the items and refined the item wording. Second, a cohort study (n = 45) with 2 assessment points was conducted to permit preliminary maximum-likelihood exploratory factor analysis and Rasch analysis. Results The Delphi panel reached consensus on 53 potential items that were carried forward to the cohort phase. From the 2 time points, 81 questionnaires were completed and analyzed; 38 potential items were eliminated on account of greater than 10% missing data, factor loadings, and uniqueness. The 15 unidimensional items retained in the scale demonstrated appropriate person and item reliability after (and before) removal of 1 item (anxious about footwear) that had a higher-than-ideal outfit statistic (1.75). The “anxious about footwear” item was retained in the instrument, but only the 14 items with acceptable infit and outfit statistics (range, 0.5–1.5) were included in the summary score. Conclusion This investigation developed and refined the A-FORM (Version 1.0). The A-FORM items demonstrated favorable psychometric properties and are suitable for conversion to a single summary score. Further studies utilizing the A-FORM instrument are warranted. J Orthop Sports Phys Ther 2014;44(7):488–499. Epub 22 May 2014. doi:10.2519/jospt.2014.4980

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the variety of PV inverter types and the number of transformerless PV inverters on the Australian market increasing, we revisit some of the issues associated with these topologies. A recent electric shock incident in Queensland (luckily without serious outcome) associated with a transformerless PV system, highlights the need for earthing PV array structures and PV module frames to prevent capacitive leakage currents causing electric shock. The presented test results of the relevant voltages associated with leakage currents of five transformerless PV inverters stress this requirement, which is currently being addressed by both the Clean Energy Council and Standards Australia. DC current injection tests were performed on the same five inverters and were used to develop preliminary recommendations for a more meaningful DC current test procedure for AS4777 Part 2. The test circuit, methodology and results are presented and discussed. A notable temperature dependency of DC current injections with three of the five inverters suggests that DC current injection should be tested at high and low internal inverter temperatures whereas the power dependency noted only for one inverter does not seem to justify recommendations for a (rather involved) standard test procedure at different power levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Only some of the information contained in a medical record will be useful to the prediction of patient outcome. We describe a novel method for selecting those outcome predictors which allow us to reliably discriminate between adverse and benign end results. Using the area under the receiver operating characteristic as a nonparametric measure of discrimination, we show how to calculate the maximum discrimination attainable with a given set of discrete valued features. This upper limit forms the basis of our feature selection algorithm. We use the algorithm to select features (from maternity records) relevant to the prediction of failure to progress in labour. The results of this analysis motivate investigation of those predictors of failure to progress relevant to parous and nulliparous sub-populations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose Dermatologic adverse events (dAEs) in cancer treatment are frequent with the use of targeted therapies. These dAEs have been shown to have significant impact on health-related quality of life (HRQoL). While standardized assessment tools have been developed for physicians to assess severity of dAEs, there is a discord between objective and subjective measures. The identification of patient-reported outcome (PRO) instruments useful in the context of targeted cancer therapies is therefore important in both the clinical and research settings for the overall evaluation of dAEs and their impact on HRQoL. Methods A comprehensive, systematic literature search of published articles was conducted by two independent reviewers in order to identify PRO instruments previously utilized in patient populations with dAEs from targeted cancer therapies. The identified PRO instruments were studied to determine which HRQoL issues relevant to dAEs were addressed, as well as the process of development and validation of these instruments. Results Thirteen articles identifying six PRO instruments met the inclusion criteria. Four instruments were general dermatology (Skindex-16©, Skindex-29©, Dermatology Life Quality Index (DLQI), and DIELH-24) and two were symptom-specific (functional assessment of cancer therapy-epidermal growth factor receptor inhibitor-18 (FACT-EGFRI-18) and hand-foot syndrome-14 (HFS-14)). Conclusions While there are several PRO instruments that have been tested in the context of targeted cancer therapy, additional work is needed to develop new instruments and to further validate the instruments identified in this study in patients receiving targeted therapies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study investigated the influence of injury cause, contact-sport participation, and prior knowledge of mild traumatic brain injury (mTBI) on injury beliefs and chronic symptom expectations of mTBI. Method: A total of 185 non-contact-sport players (non-CSPs) and 59 contact-sport players (CSPs) with no history of mTBI were randomly allocated to one of two conditions in which they read either a vignette depicting a sport-related mTBI (mTBIsport) or a motor-vehicle-accident-related mTBI (mTBIMVA). The vignettes were otherwise standardized to convey the same injury parameters (e.g., duration of loss of consciousness). After reading a vignette, participants reported their injury beliefs (i.e., perceptions of injury undesirability, chronicity, and consequences) and their expectations of chronic postconcussion syndrome (PCS) and posttraumatic stress disorder (PTSD) symptoms. Results: Non-CSPs held significantly more negative beliefs and expected greater PTSD symptomatology and greater PCS affective symptomatology from an mTBIMVA vignette thann mTBIsport vignette, but this difference was not found for CSPs. Unlike CSPs, non-CSPs who personally knew someone who had sustained an mTBI expected significantly less PCS symptomatology than those who did not. Despite these different results for non-CSPs and CSPs, overall, contact-sport participation did not significantly affect injury beliefs and symptom expectations from an mTBIsport. Conclusions: Expectations of persistent problems after an mTBI are influenced by factors such as injury cause even when injury parameters are held constant. Personal knowledge of mTBI, but not contact sport participation, may account for some variability in mTBI beliefs and expectations. These factors require consideration when assessing mTBI outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To review records of 330 patients who underwent surgery for femoral neck fractures with or without preoperative anticoagulation therapy. METHODS Medical records of 235 women and 95 men aged 48 to 103 years (mean, 81.6; standard deviation [SD], 13.1) who underwent surgery for femoral neck fractures with or without preoperative anticoagulation therapy were reviewed. 30 patients were on warfarin, 105 on aspirin, 28 on clopidogrel, and 167 were controls. The latter 3 groups were combined as the non-warfarin group and compared with the warfarin group. Hospital mortality, time from admission to surgery, length of hospital stay, return to theatre, and postoperative complications (wound infection, deep vein thrombosis, and pulmonary embolism) were assessed. RESULTS The warfarin and control groups were significantly younger than the clopidogrel and aspirin groups (80.8 vs. 80.0 vs. 84.2 vs. 83.7 years, respectively, p<0.05). 81% of the patients underwent surgery within 48 hours of admission. The overall mean time from admission to surgery was 1.8 days; it was longer in the warfarin than the aspirin, clopidogrel, and control groups (3.3 vs. 1.8 vs. 1.6 vs. 1.6 days, respectively, p<0.001). The mean length of hospital stay was 17.5 (SD, 9.6; range, 3-54) days. The overall hospital mortality was 3.9%; it was 6.7% in the warfarin group, 3.8% in the aspirin group, 3.6% in the clopidogrel group, and 3.6% in the control group (p=0.80). Four patients returned to theatre for surgery: one in the warfarin group for washout of a haematoma, 2 in the aspirin group for repositioning of a mal-fixation and for debridement of wound infection, and one in the control group for debridement of wound infection. The warfarin group did not differ significantly from non-warfarin group in terms of postoperative complication rate (6.7% vs. 2.7%, p=0.228) and the rate of return to theatre (3.3% vs. 1%, p=0.318). CONCLUSION It is safe to continue aspirin and clopidogrel prior to surgical treatment for femoral neck fracture. The risk of delaying surgery outweighs the peri-operative bleeding risk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the efficacy and safety of adalimumab in patients with non-radiographic axial spondyloarthritis (nr-axSpA). Methods: Patients fulfilled Assessment of Spondyloarthritis international Society (ASAS) criteria for axial spondyloarthritis, had a Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) score of ≥ 4, total back pain score of ≥ 4 (10 cm visual analogue scale) and inadequate response, intolerance or contraindication to non-steroidal anti-inflammatory drugs (NSAIDs); patients fulfilling modified New York criteria for ankylosing spondylitis were excluded. Patients were randomised to adalimumab (N=91) or placebo (N=94). The primary endpoint was the percentage of patients achieving ASAS40 at week 12. Efficacy assessments included BASDAI and Ankylosing Spondylitis Disease Activity Score (ASDAS). MRI was performed at baseline and week 12 and scored using the Spondyloarthritis Research Consortium of Canada (SPARCC) index. Results: Significantly more patients in the adalimumab group achieved ASAS40 at week 12 compared with patients in the placebo group (36% vs 15%, p<0.001). Significant clinical improvements based on other ASAS responses, ASDAS and BASDAI were also detected at week 12 with adalimumab treatment, as were improvements in quality of life measures. Inflammation in the spine and sacroiliac joints on MRI significantly decreased after 12 weeks of adalimumab treatment. Shorter disease duration, younger age, elevated baseline C-reactive protein or higher SPARCC MRI sacroiliac joint scores were associated with better week 12 responses to adalimumab. The safety profile was consistent with what is known for adalimumab in ankylosing spondylitis and other diseases. Conclusions: In patients with nr-axSpA, adalimumab treatment resulted in effective control of disease activity, decreased inflammation and improved quality of life compared with placebo. Results from ABILITY-1 suggest that adalimumab has a positive benefit-risk profile in active nr-axSpA patients with inadequate response to NSAIDs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Physical and psychological decline is common in the post-treatment breast cancer population, yet the efficacy of concurrent interventions to meet both physical- psychosocial needs in this population has not been extensively examined. PURPOSE: This study explores the effects of a combined exercise and psychosocial intervention model on selected physiological-psychological parameters in post-treated breast cancer. METHODS: Forty-one breast cancer survivors were randomly assigned to one of four groups for an 8-week intervention: exercise only [EX, n=13] (aerobic and resistance training), psychosocial therapy only [PS, n=11] (biofeedback), combined EX and PS [EX+PS, n=11], or to control conditions [CO, n=6]. Mean delta score (post-intervention - baseline) were calculated for each of the following: body weight, % body fat (skin folds), predicted VO2max (Modified Bruce Protocol), overall dynamic muscular endurance [OME] (RMCRI protocol), static balance (Single leg stance test), dynamic balance (360° turn and 4-square step test), fatigue (Revised Piper Scale), and quality of life (FACT-B). A one-way ANOVA was used to analyze the preliminary results of this on-going randomized trial. RESULTS: Overall, there were significant differences in the delta scores for predicted VO2max, OME, and dynamic balance among the 4 groups (p<0.05). The EX+PS group showed a significant improvement in VO2max compared with the PS group (4.2 ± 3.8 vs. -0.9 ± 4.2 mL/kg/min; p<0.05). Both the EX+PS and EX groups showed significant improvements in OME compared with the PS and CO groups (44.5 ± 23.5 and 43.4 ± 22.1 vs. -3.9 ± 15.2 and 2.7 ± 13.7 repetitions; p<0.05). All 3 intervention groups showed significant improvements in dynamic balance compared with the CO group (-0.8 ± 0.6, -0.6 ± 0.8, and -0.6 ±1.0 vs. 0.6 ± 0.6 seconds; p<0.05). Overall, changes in fatigue tended towards significance among the 4 groups (p = 0.08), with decreased fatigue in the intervention groups and increased fatigue in the CO group. CONCLUSIONS: Our preliminary findings suggest that EX and PS seem to produce greater positive changes in the outcome measures than CO. However, at this point no definite conclusions can be made on the additive effects of combining the EX and PS interventions.