Objective To compare the level of agreement in results obtained from four physical activity (PA) measurement instruments that are in use in Australia and around the world. Methods 1,280 randomly selected participants answered two sets of PA questions by telephone. 428 answered the Active Australia (AA) and National Health Surveys, 427 answered the AA and CDC Behavioural Risk Factor Surveillance System surveys (BRFSS), and 425 answered the AA survey and the short International Physical Activity Questionnaire (IPAQ). Results Among the three pairs of survey items, the difference in mean total PA time was lowest when the AA and NHS items were asked (difference=24) (SE:17) minutes, compared with 144 (SE:21) mins for AA/BRFSS and 406 (SE:27) mins for AA/IPAQ). Correspondingly, prevalence estimates for 'sufficiently active' were similar for AA and NHS (56% and 55% respectively), but about 10% higher when BRFSS data were used, and about 26% higher when the IPAQ items were used, compared with estimates from the AA survey. Conclusions The findings clearly demonstrate that there are large differences in reported PA times and hence in prevalence estimates of 'sufficient activity' from these four measures. Implications It is important to consistently use the same survey for population monitoring purposes. As the AA survey has now been used three times in national surveys, its continued use for population surveys is recommended so that trend data ever a longer period of time can be established.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Design Delphi panel and cohort study. Objective To develop and refine a condition-specific, patient-reported outcome measure, the Ankle Fracture Outcome of Rehabilitation Measure (A-FORM), and to examine its psychometric properties, including factor structure, reliability, and validity, by assessing item fit with the Rasch model. Background To our knowledge, there is no patient-reported outcome measure specific to ankle fracture with a robust content foundation. Methods A 2-stage research design was implemented. First, a Delphi panel that included patients and health professionals developed the items and refined the item wording. Second, a cohort study (n = 45) with 2 assessment points was conducted to permit preliminary maximum-likelihood exploratory factor analysis and Rasch analysis. Results The Delphi panel reached consensus on 53 potential items that were carried forward to the cohort phase. From the 2 time points, 81 questionnaires were completed and analyzed; 38 potential items were eliminated on account of greater than 10% missing data, factor loadings, and uniqueness. The 15 unidimensional items retained in the scale demonstrated appropriate person and item reliability after (and before) removal of 1 item (anxious about footwear) that had a higher-than-ideal outfit statistic (1.75). The “anxious about footwear” item was retained in the instrument, but only the 14 items with acceptable infit and outfit statistics (range, 0.5–1.5) were included in the summary score. Conclusion This investigation developed and refined the A-FORM (Version 1.0). The A-FORM items demonstrated favorable psychometric properties and are suitable for conversion to a single summary score. Further studies utilizing the A-FORM instrument are warranted. J Orthop Sports Phys Ther 2014;44(7):488–499. Epub 22 May 2014. doi:10.2519/jospt.2014.4980

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis represents a significant step forward in developing a validated measure for diabetic peripheral neuropathy – a debilitating and prevalent complication of diabetes. The candidate investigated corneal nerve structure in healthy people as well as in type 1 diabetic individuals in a 4-year longitudinal study. The outcomes of stability of the corneal small nerve fibre in healthy people and evidence of significant decline in diabetic individuals with peripheral neuropathy over time provide justification for the ongoing efforts to establish corneal nerve structure as an objective and appropriate adjunct to conventional measures of peripheral neuropathy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Self-report measures are typically used to assess the effectiveness of road safety advertisements. However, psychophysiological measures of persuasive processing (i.e., skin conductance response [SCR]) and objective driving measures of persuasive outcomes (i.e., in-vehicle GPS devices) may provide further insights into the effectiveness of these advertisements. This study aimed to explore the persuasive processing and outcomes of two anti-speeding advertisements by incorporating both self-report and objective measures of speeding behaviour. In addition, this study aimed to compare the findings derived from these different measurement approaches. Methods Young drivers (N = 20, Mage = 21.01 years) viewed either a positive or negative emotion-based anti-speeding television advertisement. Whilst viewing the advertisement, SCR activity was measured to assess ad-evoked arousal responses. The RoadScout® GPS device was then installed into participants’ vehicles for one week to measure on-road speed-related driving behaviour. Self-report measures assessed persuasive processing (emotional and arousal responses) and actual driving behaviour. Results There was general correspondence between the self-report measures of arousal and the SCR and between the self-report measure of actual driving behaviour and the objective driving data (as assessed via the GPS devices). Conclusions This study provides insights into how psychophysiological and GPS devices could be used as objective measures in conjunction with self-report measures to further understand the persuasive processes and outcomes of emotion-based anti-speeding advertisements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation of psychomotor skills is undertaken in a number of broad contexts. This includes testing of health professional populations as a measure of innate ability, to evaluate skill acquisition, or to compare professions. However, the use of psychomotor tests is frequently confounded by a lack of understanding of a particular tool's psychometric properties, strengths, and weaknesses. To identify and appraise the most commonly used tests on health professional populations, 86 articles were reviewed and the top nine tests identified. Few tests have had sufficient validity or reliability testing on health professionals. Based on the evidence available, use of the Grooved Pegboard Test, the Purdue Pegboard Test, or the Finger Tapping Test is recommended for the evaluation of dexterity in a health professional population; however, this choice may be dependent on the task(s) to which findings are generalised. More rigorous evaluation of validity and other psychometric properties is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction and Aims Wastewater analysis (WWA) is intended to be a direct and objective method of measuring substance use in large urban populations. It has also been used to measure prison substance use in two previous studies. The application of WWA in this context has raised questions as to how best it might be used to measure illicit drug use in prisons, and whether it can also be used to measure prescription misuse. We applied WWA to a small regional prison to measure the use of 12 licit and illicit substances. We attempted to measure the non-medical use of methadone and buprenorphine and to compare our findings with the results of the prison's mandatory drug testing (MDT). Design and Methods Representative daily composite samples were collected for two periods of 12 consecutive days in May to July 2013 and analysed for 18 drug metabolites. Prescription data and MDT results were obtained from the prison and compared with the substance use estimates calculated from WWA data. Results Daily use of methamphetamine, methadone, buprenorphine and codeine was detected, while sporadic detection of ketamine and methylone was also observed. Overall buprenorphine misuse appeared to be greater than methadone misuse. Discussion and Conclusions Compared with MDT, WWA provides a more comprehensive picture of prison substance use. WWA also has the potential to measure the misuse of medically prescribed substances. However, a great deal of care must be exercised in quantifying the usage of any substance in small populations, such as in prisons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article focusses upon multi-modal transportation systems (MMTS) and the issues surrounding the determination of system capacity. For that purpose a multi-objective framework is advocated that integrates all the different modes and many different competing capacity objectives. This framework is analytical in nature and facilitates a variety of capacity querying and capacity expansion planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To develop a short and easy to use questionnaire to measure use and usability of custom-made orthopaedic shoes, and to investigate its reproducibility. DESIGN Development of the questionnaire (Monitor Orthopaedic Shoes) was based on a literature search, expert interviews, 2 expert meetings, and exploration and testing of reproducibility. The questionnaire comprises 2 parts: a pre part, measuring expectations; and a post part, measuring experiences. Patients The pre part of the final version was completed twice by 37 first-time users before delivery of their orthopaedic shoes. The post part of the final version was completed twice by 39 first-time users who had worn their orthopaedic shoes for 2–4 months. RESULTS High reproducibility scores (Cohen’s kappa > 0.60 or intra class correlation > 0.70) were found in all but one question of both parts of the final version of the Monitor Orthopaedic Shoes questionnaire. The smallest real difference on a visual analogue scale (100 mm) ranged from 21 to 50 mm. It took patients approximately 15 minutes to complete one part. CONCLUSION Monitor Orthopaedic Shoes is a practical and reproducible questionnaire that can measure relevant aspects of use and usability of orthopaedic shoes from a patient’s perspective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Orgasm is a subjective experience accompanied by involuntary muscle contractions. We hypothesized that orgasm in women would be distinguishable by frequency analysis of a perineal muscle-derived signal. Rectal pressure, an index of perineal muscle activity, was measured continuously in 23 healthy women during different sexual tasks: receiving clitoral stimulation, imitation of orgasm, and attempt to reach orgasm, in which case the women were asked to report whether orgasm had been reached ("orgasm") or not ("failed orgasm attempt"). We performed spectral analysis on the rectal pressure data and calculated the spectral power in the frequency bands delta (0.5-4 Hz), theta (4-8 Hz), alpha (8-13 Hz), and beta (13-25 Hz). The most significant and most important difference in spectral power between orgasm and both control motor tasks (imitation of orgasm and failed orgasm attempt) was found in the alpha band. An objective rule based on spectral power in the alpha band recognized 94% (29/31) of orgasms and correctly labeled 69% (44/64) of all orgasm attempts as either successful or failed. Because outbursts of alpha fluctuations in rectal pressure only occurred during orgasm and not during voluntary imitation of orgasm or failed attempts, we propose that they represent involuntary contractions of muscles in the rectal vicinity. This is the first objective and quantitative measure that has a strong correspondence with the subjective experience of orgasm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the scored Patient-generated Subjective Global Assessment (PG-SGA) tool as an outcome measure in clinical nutrition practice and determine its association with quality of life (QoL). DESIGN: A prospective 4 week study assessing the nutritional status and QoL of ambulatory patients receiving radiation therapy to the head, neck, rectal or abdominal area. SETTING: Australian radiation oncology facilities. SUBJECTS: Sixty cancer patients aged 24-85 y. INTERVENTION: Scored PG-SGA questionnaire, subjective global assessment (SGA), QoL (EORTC QLQ-C30 version 3). RESULTS: According to SGA, 65.0% (39) of subjects were well-nourished, 28.3% (17) moderately or suspected of being malnourished and 6.7% (4) severely malnourished. PG-SGA score and global QoL were correlated (r=-0.66, P<0.001) at baseline. There was a decrease in nutritional status according to PG-SGA score (P<0.001) and SGA (P<0.001); and a decrease in global QoL (P<0.001) after 4 weeks of radiotherapy. There was a linear trend for change in PG-SGA score (P<0.001) and change in global QoL (P=0.003) between those patients who improved (5%) maintained (56.7%) or deteriorated (33.3%) in nutritional status according to SGA. There was a correlation between change in PG-SGA score and change in QoL after 4 weeks of radiotherapy (r=-0.55, P<0.001). Regression analysis determined that 26% of the variation of change in QoL was explained by change in PG-SGA (P=0.001). CONCLUSION: The scored PG-SGA is a nutrition assessment tool that identifies malnutrition in ambulatory oncology patients receiving radiotherapy and can be used to predict the magnitude of change in QoL.