750 resultados para N-2 Fixation
Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur
Resumo:
Recently the National Patient Safety Agency in the United Kingdom published a report entitled "Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur". A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.
Resumo:
Online technological advances are pioneering the wider distribution of geospatial information for general mapping purposes. The use of popular web-based applications, such as Google Maps, is ensuring that mapping based applications are becoming commonplace amongst Internet users which has facilitated the rapid growth of geo-mashups. These user generated creations enable Internet users to aggregate and publish information over specific geographical points. This article identifies privacy invasive geo-mashups that involve the unauthorized use of personal information, the inadvertent disclosure of personal information and invasion of privacy issues. Building on Zittrain’s Privacy 2.0, the author contends that first generation information privacy laws, founded on the notions of fair information practices or information privacy principles, may have a limited impact regarding the resolution of privacy problems arising from privacy invasive geo-mashups. Principally because geo-mashups have different patterns of personal information provision, collection, storage and use that reflect fundamental changes in the Web 2.0 environment. The author concludes by recommending embedded technical and social solutions to minimize the risks arising from privacy invasive geo-mashups that could lead to the establishment of guidelines for the general protection of privacy in geo-mashups.
Resumo:
This report is for one of the four Tasks of the CRC project ‘Regenerating Construction to Enhance Sustainability’. The report specifically addresses Task 2 ‘Design guidelines for delivering high quality indoor environments’.
Resumo:
In the title compound, [Al(C8H4F3O2S)3]3[Fe(C8H4F3O2S)3], the metal centre is statistically occupied by AlIII and FeIII cations in a 3:1 ratio. The metal centre is within an octahedral O6 donor set defined by three chelating substituted acetoacetonate anions. The ligands are arranged around the periphery of the molecule with a mer geometry of the S atoms.
Resumo:
Top screw pullout occurs when the screw is under too much axial force to remain secure in the vertebral body. In vitro biomechanical pullout tests are commonly done to find the maximum fixation strength of anterior vertebral body screws. Typically, pullout tests are done instantaneously where the screw is inserted and then pulled out immediately after insertion. However, bone is a viscoelastic material so it shows a time dependent stress and strain response. Because of this property, it was hypothesised that creep occurs in the vertebral trabecular bone due to the stress caused by the screw. The objective of this study was therefore to determine whether the axial pullout strength of anterior vertebral body screws used for scoliosis correction surgery changes with time after insertion. This study found that there is a possible relationship between pullout strength and time; however more testing is required as the sample numbers were quite small. The design of the screw is made with the knowledge of the strength it must obtain. This is important to prevent such occurrences as top screw pullout. If the pullout strength is indeed decreased due to creep, the design of the screw may need to be changed to withstand greater forces.