128 resultados para Fluorescent conjugation
Resumo:
Cellular response to radiation damage is made by a complex network of pathways and feedback loops whose spatiotemporal organisation is still unclear despite its decisive role in determining the fate of the damaged cell. Revealing the dynamic sequence of the repair proteins is therefore critical in understanding how the DNA repair mechanisms work. There are also still open questions regarding the possible movement of damaged chromatin domains and its role as trigger for lesion recognition and signalling in the DNA repair context. The single-cell approach and the high spatial resolution offered by microbeams provide the perfect tool to study and quantify the dynamic processes associated with the induction and repair of DNA damage. We have followed the development of radiation-induced foci for three DNA damage markers (i.e. γ-H2AX, 53BP1 and hSSB1) using normal fibroblasts (AG01522), human breast adenocarcinoma cells (MCF7) and human fibrosarcoma cells (HT1080) stably transfected with yellow fluorescent protein fusion proteins following irradiation with the QUB X-ray microbeam (carbon X-rays <2 µm spot). The size and intensity of the foci has been analysed as a function of dose and time post-irradiation to investigate the dynamics of the above-mentioned DNA repair processes and monitor the remodelling of chromatin structure that the cell undergoes to deal with DNA damage.
Resumo:
Azobenzenes (1,2-diaryldiazenes) are very important organic pigments, and they have a unique place in the field of photoresponsive conjugated molecules due to their (usually) reversible E/Z photoisomerisation. The current intense interest in molecular analogues of mechanical components and information storage and processing elements has stimulated research into conjugated molecules whose shape and/or optical properties can be switched electro- or photochemically. Among the classes of conjugated pigments being explored in these contexts are the porphyrinoids, which offer advantages of intense light absorption, a variety of accessible oxidation states, and synthetic control of properties through peripheral or central substitution. Extension of porphyrinoid conjugation can be achieved by linking the peripheral carbons either by three direct bonds (as in the “porphyrin tapes” of Osuka et al.) or through potentially conjugating bridges such as alkenes or, even better, alkynes.
Resumo:
It is likely that effective application of cell-laden implants for cartilage defects depends on retention of implanted cells and interaction between implanted and host cells. The objectives of this study were to characterize stratified cartilaginous constructs seeded sequentially with superficial (S) and middle (M) chondrocyte subpopulations labelled with fluorescent cell tracking dye PKH26 (*) and determine the degree to which these stratified cartilaginous constructs maintain their architecture in vivo after implantation in mini-pigs for 1 week. Alginate-recovered cells were seeded sequentially to form stratified S*/M (only S cells labelled) and S*/M* (both S and M cells labelled) constructs. Full-thickness defects (4 mm diameter) were created in the patellofemoral groove of adult Yucatan mini-pigs and filled with portions of constructs or left empty. Constructs were characterized biochemically, histologically, and biomechanically, and stratification visualized and quantified, before and after implant. After 1 week, animals were sacrificed and implants retrieved. After 1 week in vivo, glycosaminoglycan and collagen content of constructs remained similar to that at implant, whereas DNA content increased. Histological analyses revealed features of an early repair response, with defects filled with tissues containing little matrix and abundant cells. Some implanted (PKH26-labeled) cells persisted in the defects, although constructs did not maintain a stratified organization. Of the labelled cells, 126 +/- 38% and 32 +/- 8% in S*/M and S*/M* constructs, respectively, were recovered. Distribution of labelled cells indicated interactions between implanted and host cells. Longer-term in vivo studies will be useful in determining whether implanted cells are sufficient to have a positive effect in repair.
Resumo:
Activated protein C resistance (APCR), the most common risk factor for venous thrombosis, is the result of a G to A base substitution at nucleotide 1691 (R506Q) in the factor V gene. Current techniques to detect the factor V Leiden mutation, such as determination of restriction length polymorphisms, do not have the capacity to screen large numbers of samples in a rapid, cost- effective test. The aim of this study was to apply the first nucleotide change (FNC) technology, to the detection of the factor V Leiden mutation. After preliminary amplification of genomic DNA by polymerase chain reaction (PCR), an allele-specific primer was hybridised to the PCR product and extended using fluorescent terminating dideoxynucleotides which were detected by colorimetric assay. Using this ELISA-based assay, the prevalence of the factor V Leiden mutation was determined in an Australian blood donor population (n = 500). A total of 18 heterozygotes were identified (3.6%) and all of these were confirmed with conventional MnlI restriction digest. No homozygotes for the variant allele were detected. We conclude from this study that the frequency of 3.6% is compatible with others published for Caucasian populations. In addition, the FNC technology shows promise as the basis for a rapid, automated DNA based test for factor V Leiden.
Resumo:
Endocytosis is the process by which cells internalise molecules including nutrient proteins from the extracellular media. In one form, macropinocytosis, the membrane at the cell surface ruffles and folds over to give rise to an internalised vesicle. Negatively charged phospholipids within the membrane called phosphoinositides then undergo a series of transformations that are critical for the correct trafficking of the vesicle within the cell, and which are often pirated by pathogens such as Salmonella. Advanced fluorescent video microscopy imaging now allows the detailed observation and quantification of these events in live cells over time. Here we use these observations as a basis for building differential equation models of the transformations. An initial investigation of these interactions was modelled with reaction rates proportional to the sum of the concentrations of the individual constituents. A first order linear system for the concentrations results. The structure of the system enables analytical expressions to be obtained and the problem becomes one of determining the reaction rates which generate the observed data plots. We present results with reaction rates which capture the general behaviour of the reactions so that we now have a complete mathematical model of phosphoinositide transformations that fits the experimental observations. Some excellent fits are obtained with modulated exponential functions; however, these are not solutions of the linear system. The question arises as to how the model may be modified to obtain a system whose solution provides a more accurate fit.
Resumo:
This paper presents a review on the use of tethered nitroxide–fluorophore molecules as probes of oxidative change and free radical generation and reaction. The proximity of the nitroxide free radical to the fluorophore suppresses the normal fluorescence emission process. Nitroxide free radical scavenging, metabolism or redox chemistry return the system to its natural fluorescent state and so these tethered nitroxide–fluorophore molecules are described as being profluorescent. A survey of profluorescent nitroxides found in the literature is provided as well as background on the mechanism of action and applications of these compounds as fluorometric probes within the fields of biological, materials and environmental sciences.
Resumo:
This project focused on the first application of the copper catalyzed azide alkyne cycloaddition reaction for the generation of novel profluorescent systems. Through this approach four novel profluorescent nitroxides were prepared both rapidly and in good yield from coumarin and nitroxide CuAAC coupling partners. Specifically, 7-hydroxy, 7-diethylamino, 6-bromo and unsubstituted coumarin analogues bearing an azide group in the 3-position were prepared and conjugatively joined to an alkyne isoindoline nitroxide previously reported by our group. To explore the impact of the nitroxide moiety on the fluorescence of these systems, methoxyamine analogues of the corresponding nitroxide analogues were prepared. Spectrophotometric analysis of these methoxyamine analogues revealed that the aromatic systems possessed high quantum yields. However, the quantum yield efficiency was found to be dependent on the presence of electron donating substituents in the 7-position of the coumarin motif, which enhanced the charge-transfer character of the system. Furthermore, spectrophotometric analysis of nitroxide analogues demonstrated that the triazole effectively mediated fluorophore-nitroxide communication, as evidenced by the low quantum yield values of the nitroxide analogues. These results suggest that this technique can be used to conjugatively join any azide bearing fluorescent system with the key alkyne isoindoline coupling partner allowing for the rapid generation of diverse profluorescent systems.
Resumo:
A time-resolved inverse spatially offset Raman spectrometer was constructed for depth profiling of Raman-active substances under both the lab and the field environments. The system operating principles and performance are discussed along with its advantages relative to traditional continuous wave spatially offset Raman spectrometer. The developed spectrometer uses a combination of space- and time-resolved detection in order to obtain high-quality Raman spectra from substances hidden behind coloured opaque surface layers, such as plastic and garments, with a single measurement. The time-gated spatially offset Raman spectrometer was successfully used to detect concealed explosives and drug precursors under incandescent and fluorescent background light as well as under daylight. The average screening time was 50 s per measurement. The excitation energy requirements were relatively low (20 mW) which makes the probe safe for screening hazardous substances. The unit has been designed with nanosecond laser excitation and gated detection, making it of lower cost and complexity than previous picosecond-based systems, to provide a functional platform for in-line or in-field sensing of chemical substances.
Resumo:
Regulatory sequences with endosperm specificity are essential for foreign gene expression in the desired tissue for both grain quality improvement and molecular pharming. In this study, promoters of seed storage α-kafirin genes coupled with signal sequence (ss) were isolated from Sorghum bicolor L. Moench genomic DNA by PCR. The α-kafirin promoter (α-kaf) contains endosperm specificity-determining motifs, prolamin-box, the O2-box 1, CATC, and TATA boxes required for α-kafirin gene expression in sorghum seeds. The constructs pMB-Ubi-gfp and pMB-kaf-gfp were microprojectile bombarded into various sorghum and sweet corn explants. GFP expression was detected on all explants using the Ubi promoter but only in seeds for the α-kaf promoter. This shows that the α-kaf promoter isolated was functional and demonstrated seed-specific GFP expression. The constructs pMB-Ubi-ss-gfp and pMB-kaf-ss-gfp were also bombarded into the same explants. Detection of GFP expression showed that the signal peptide (SP)::GFP fusion can assemble and fold properly, preserving the fluorescent properties of GFP.
Resumo:
Spatially offset Raman spectroscopy (SORS) is demonstrated for the non-contact detection of energetic materials concealed within non-transparent, diffusely scattering containers. A modified design of an inverse SORS probe has been developed and tested. The SORS probe has been successfully used for the detection of various energetic substances inside different types of plastic containers. The tests have been successfully conducted under incandescent and fluorescent background lights as well as under daylight conditions, using a non-contact working distance of 6 cm. The interrogation times for the detection of the substances were less than 1 minute in each case, highlighting the suitability of the device for near real-time detection of concealed hazards in the field. The device has potential applications in forensic analysis and homeland security investigations.
Resumo:
Homo-and heteronuclear meso,meso-(E)-ethene-1,2-diyl-linked diporphyrins have been prepared by the Suzuki coupling of porphyrinylboronates and iodovinylporphyrins. Combinations comprising 5,10,15-triphenylporphyrin (TriPP) on both ends of the ethene-1,2-diyl bridge M 210 (M 2=H 2/Ni, Ni 2, Ni/Zn, H 4, H 2Zn, Zn 2) and 5,15-bis(3,5-di-tert-butylphenyl)porphyrinato-nickel(II) on one end and H 2, Ni, and ZnTriPP on the other (M 211), enable the first studies of this class of compounds possessing intrinsic polarity. The compounds were characterized by electronic absorption and steady state emission spectra, 1H NMR spectra, and for the Ni 2 bis(TriPP) complex Ni 210, single crystal X-ray structure determination. The crystal structure shows ruffled distortions of the porphyrin rings, typical of Ni II porphyrins, and the (E)-C 2H 2 bridge makes a dihedral angle of 50° with the mean planes of the macrocycles. The result is a stepped parallel arrangement of the porphyrin rings. The dihedral angles in the solid state reflect the interplay of steric and electronic effects of the bridge on interporphyrin communication. The emission spectra in particular, suggest energy transfer across the bridge is fast in conformations in which the bridge is nearly coplanar with the rings. Comparisons of the fluorescence behaviour of H 410 and H 2Ni10 show strong quenching of the free base fluorescence when the complex is excited at the lower energy component of the Soret band, a feature associated in the literature with more planar conformations. TDDFT calculations on the gas-phase optimized geometry of Ni 210 reproduce the features of the experimental electronic absorption spectrum within 0.1 eV. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Resumo:
Introduction Government promotion of active transport has renewed interest in cycling safety. Research has shown that bicyclists are up to 20 times more likely to be involved in serious injury crashes than drivers. On-road cycling injuries are under-reported in police data, and many non-serious injuries are not recorded in any official database. This study aims to explore the relationships between rider characteristics and environmental factors that influence per kilometre risk of bicycle-related crash and non-crash injuries. Method A survey of 2,532 Queensland adults who had ridden at least once in the past year was conducted from October 2009 to March 2010, with most responses received online (99.3%). Riders were asked where they rode (footpath, bike path, road etc.), average travel speed, purpose of riding, type of bike ridden, how far and how often they rode in. Measures of rider experience, skill, safety perceptions, safety behaviours, crash involvement and demographic characteristics were also collected. RESULTS Increasing exposure and having more expensive bicycles were shown to reduce the risk per km of crash and non-crash injury rates, and to reduce perceived risk. Never wearing bright coloured clothing related to increased crash risk, use of fluorescent and reflective clothing had no effect on crash risk. Riding in low-speed environments, never using a front light, and riding in low-speed environments were associated with reduced non-crash injury risk. Perceived risk was influenced by exposure, use of conspicuity aids and helmets, riding for utilitarian reasons, and group-riding behaviours. DISCUSSION Perceived risk does not appear to influence injury rates and injury rates do not appear to influence the perceived risk of cycling. Riders who perceive cycling to be risky tend not to be commuters, do not engage in group riding and always wear helmets. Not all measures of conspicuity were associated with risk, with rear lights found to have no relationship to injury. The risks of experiencing a crash or non-crash injury were similar, therefore injury prevention strategies should expand their scope to include other factors such as the importance of bicycle set-up.
Resumo:
Current concerns regarding terrorism and international crime highlight the need for new techniques for detecting unknown and hazardous substances. A novel Raman spectroscopy-based technique, spatially offset Raman spectroscopy (SORS), was recently devised for non-invasively probing the contents of diffusely scattering and opaque containers. Here, we demonstrate a modified portable SORS sensor for detecting concealed substances in-field under different background lighting conditions. Samples including explosive precursors, drugs and an organophosphate insecticide (chemical warfare agent surrogate) were concealed inside diffusely scattering packaging including plastic, paper and cloth. Measurements were carried out under incandescent and fluorescent light as well as under daylight to assess the suitability of the probe for different real-life conditions. In each case, it was possible to identify the substances against their reference Raman spectra in less than one minute. The developed sensor has potential for rapid detection of concealed hazardous substances in airports, mail distribution centers and customs checkpoints.