493 resultados para Cross-layer optimization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Particle Swarm Optimization (PSO) is a biologically inspired computational search and optimization method based on the social behaviors of birds flocking or fish schooling. Although, PSO is represented in solving many well-known numerical test problems, but it suffers from the premature convergence. A number of basic variations have been developed due to solve the premature convergence problem and improve quality of solution founded by the PSO. This study presents a comprehensive survey of the various PSO-based algorithms. As part of this survey, the authors have included a classification of the approaches and they have identify the main features of each proposal. In the last part of the study, some of the topics within this field that are considered as promising areas of future research are listed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study empirically examines the motivators that influence a consumer’s intentions to use mobile banking. A web-based survey was employed to collect data from 348 respondents, split across Thailand and Australia. Data were analysed by employing exploratory and confirmatory factor analyses, path and invariance analyses. The findings indicate that for Australian consumers, perceived ease of use, perceived usefulness and perceived risk were the primary determinants of mobile banking adoption. For Thai consumers, the main factors were perceived usefulness, perceived risk and social influence. National culture was found to impact key antecedents that lead to adoption of m-banking. Interestingly, the actual variance explained by this study’s model was higher in Australia than for Thailand, suggesting future research of m-banking adoption in emerging Asian cultures. The findings of this research give banking organisations a foundational model that can be used to support m-banking implementation. This study is perhaps the first to examine and compare the intention to adopt m-banking across Thai and Australian consumers, and responds to calls for additional research that generalises m-banking and m-services acceptance across cultures. This study has proposed and validated additional constructs that are not present in the original SST Intention to Use model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The purpose of this study was to adapt and validate the Foot Function Index to the Spanish (FFI-Sp) following the guidelines of the American Academy of Orthopaedic Surgeons. Methods A cross-sectional study 80 participants with some foot pathology. A statistical analysis was made, including a correlation study with other questionnaires (the Foot Health Status Questionnaire, EuroQol 5-D, Visual Analogue Pain Scale, and the Short Form SF-12 Health Survey). Data analysis included reliability, construct and criterion-related validity and factor analyses. Results The principal components analysis with varimax rotation produced 3 principal factors that explained 80% of the variance. The confirmatory factor analysis showed an acceptable fit with a comparative fit index of 0.78. The FFI-Sp demonstrated excellent internal consistency on the three subscales: pain 0.95; disability 0.96; and activity limitation 0.69, the subscale that scored lowest. The correlation between the FFI-Sp and the other questionnaires was high to moderate. Conclusions The Spanish version of the Foot Function Index (FFI-Sp) is a tool that is a valid and reliable tool with a very good internal consistency for use in the assessment of pain, disability and limitation of the function of the foot, for use both in clinic and research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Foot dorsiflexion plays an essential role in both controlling balance and human gait. Electromyography (EMG) and sonomyography (SMG) can provide information on several aspects of muscle function. The aim was to establish the relationship between the EMG and SMG variables during isotonic contractions of foot dorsiflexors. Methods Twenty-seven healthy young adults performed the foot dorsiflexion test on a device designed ad hoc. EMG variables were maximum peak and area under the curve. Muscular architecture variables were muscle thickness and pennation angle. Descriptive statistical analysis, inferential analysis and a multivariate linear regression model were carried out. The confidence level was established with a statistically significant p-value of less than 0.05. Results The correlation between EMG variables and SMG variables was r = 0.462 (p < 0.05). The linear regression model to the dependent variable “peak normalized tibialis anterior (TA)” from the independent variables “pennation angle and thickness”, was significant (p = 0.002) with an explained variance of R2 = 0.693 and SEE = 0.16. Conclusions There is a significant relationship and degree of contribution between EMG and SMG variables during isotonic contractions of the TA muscle. Our results suggest that EMG and SMG can be feasible tools for monitoring and assessment of foot dorsiflexors. TA muscle parameterization and assessment is relevant in order to know that increased strength accelerates the recovery of lower limb injuries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Index tracking is an investment approach where the primary objective is to keep portfolio return as close as possible to a target index without purchasing all index components. The main purpose is to minimize the tracking error between the returns of the selected portfolio and a benchmark. In this paper, quadratic as well as linear models are presented for minimizing the tracking error. The uncertainty is considered in the input data using a tractable robust framework that controls the level of conservatism while maintaining linearity. The linearity of the proposed robust optimization models allows a simple implementation of an ordinary optimization software package to find the optimal robust solution. The proposed model of this paper employs Morgan Stanley Capital International Index as the target index and the results are reported for six national indices including Japan, the USA, the UK, Germany, Switzerland and France. The performance of the proposed models is evaluated using several financial criteria e.g. information ratio, market ratio, Sharpe ratio and Treynor ratio. The preliminary results demonstrate that the proposed model lowers the amount of tracking error while raising values of portfolio performance measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visual information in the form of lip movements of the speaker has been shown to improve the performance of speech recognition and search applications. In our previous work, we proposed cross database training of synchronous hidden Markov models (SHMMs) to make use of external large and publicly available audio databases in addition to the relatively small given audio visual database. In this work, the cross database training approach is improved by performing an additional audio adaptation step, which enables audio visual SHMMs to benefit from audio observations of the external audio models before adding visual modality to them. The proposed approach outperforms the baseline cross database training approach in clean and noisy environments in terms of phone recognition accuracy as well as spoken term detection (STD) accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Speech recognition can be improved by using visual information in the form of lip movements of the speaker in addition to audio information. To date, state-of-the-art techniques for audio-visual speech recognition continue to use audio and visual data of the same database for training their models. In this paper, we present a new approach to make use of one modality of an external dataset in addition to a given audio-visual dataset. By so doing, it is possible to create more powerful models from other extensive audio-only databases and adapt them on our comparatively smaller multi-stream databases. Results show that the presented approach outperforms the widely adopted synchronous hidden Markov models (HMM) trained jointly on audio and visual data of a given audio-visual database for phone recognition by 29% relative. It also outperforms the external audio models trained on extensive external audio datasets and also internal audio models by 5.5% and 46% relative respectively. We also show that the proposed approach is beneficial in noisy environments where the audio source is affected by the environmental noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study we present a combinatorial optimization method based on particle swarm optimization and local search algorithm on the multi-robot search system. Under this method, in order to create a balance between exploration and exploitation and guarantee the global convergence, at each iteration step if the distance between target and the robot become less than specific measure then a local search algorithm is performed. The local search encourages the particle to explore the local region beyond to reach the target in lesser search time. Experimental results obtained in a simulated environment show that biological and sociological inspiration could be useful to meet the challenges of robotic applications that can be described as optimization problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The co-curing process for advanced grid-stiffened (AGS) composite structure is a promising manufacturing process, which could reduce the manufacturing cost, augment the advantages and improve the performance of AGS composite structure. An improved method named soft-mold aided co-curing process which replaces the expansion molds by a whole rubber mold is adopted in this paper. This co-curing process is capable to co-cure a typical AGS composite structure with the manufacturer’s recommended cure cycle (MRCC). Numerical models are developed to evaluate the variation of temperature and the degree of cure in AGS composite structure during the soft-mold aided co-curing process. The simulation results were validated by experimental results obtained from embedded temperature sensors. Based on the validated modeling framework, the cycle of cure can be optimized by reducing more than half the time of MRCC while obtaining a reliable degree of cure. The shape and size effects of AGS composite structure on the distribution of temperature and degree of cure are also investigated to provide insights for the optimization of soft-mold aided co-curing process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis explores The Virtues Project's ontological, educational and cross-cultural dimensions taking Charles Taylor's philosophical perspective of an anthropological account of the self and a phenomenological account of moral life and engagement. The experience of Mongolian schoolteachers implementing this moral education program is analyzed using a narrative inquiry method. The globally attractive project appears in moral education and virtues ethics research and surveys, yet no critical evaluation has been undertaken. Its conceptual features are appraised from a Taylorean perspective. The Listening Guide analysis of teacher experiences is presented in two narratives. The first is about the teachers' implementation experiences of moral flourishing as selves, in relationships and in community. The second is about their experience of becoming Mongolian in their modern day context. In conclusion, the project is coherent, constructive and potentially suitable cross-culturally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The use of compression garments during exercise is recommended for women with breast cancer-related lymphoedema, but the evidence behind this clinical recommendation is unclear. The aim of this randomised, cross-over trial was to compare the acute effects of wearing versus not wearing compression during a single bout of moderate-load resistance exercise on lymphoedema status and its associated symptoms in women with breast cancer-related lymphoedema. Methods Twenty-five women with clinically diagnosed, stable unilateral breast cancer-related lymphoedema completed two resistance exercise sessions, one with compression and one without, in a randomised order separated by a 14 day wash-out period. The resistance exercise session consisted of six upper-body exercises, with each exercise performed for three sets at a moderate-load (10-12 repetition maximum). Primary outcome was lymphoedema, assessed using bioimpedance spectroscopy (L-Dex score). Secondary outcomes were lymphoedema as assessed by arm circumferences (percent inter-limb difference and sum-of-circumferences), and symptom severity for pain, heaviness and tightness, measured using visual analogue scales. Measurements were taken pre-, immediately post- and 24 hours post-exercise. Results There was no difference in lymphoedema status (i.e., L-Dex scores) pre- and post-exercise sessions or between the compression and non-compression condition [Mean (SD) for compression pre-, immediately post- and 24 hours post-exercise: 17.7 (21.5), 12.7 (16.2) and 14.1 (16.7), respectively; no compression: 15.3 (18.3), 15.3 (17.8), and 13.4 (16.1), respectively]. Circumference values and symptom severity were stable across time and treatment condition. Conclusions An acute bout of moderate-load, upper-body resistance exercise performed in the absence of compression does not exacerbate lymphoedema in women with breast cancer-related lymphoedema.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The critical care context presents important opportunities for nurses to deliver skilled, comprehensive care to patients at the end of life and their families. Limited research has identified the actual end-of-life care practices of critical care nurses. Objective: To identify the end-of-life care practices of critical care nurses. Design: A national cross-sectional online survey. Methods: The survey was distributed to members of an Australian critical care nursing association and 392 critical care nurses (response rate 25%) completed the survey. Exploratory factor analysis using principal axis factoring with oblique rotation was undertaken on survey responses to identify the domains of end-of-life care practice. Descriptive statistics were calculated for individual survey items. Results: Exploratory factor analysis identified six domains of end-of-life care practice: information sharing, environmental modification, emotional support, patient and family centred decision-making, symptom management and spiritual support. Descriptive statistics identified a high level of engagement in information sharing and environmental modification practices and less frequent engagement in items from the emotional support and symptom management practice areas. Conclusions: The findings of this study identified domains of end-of-life care practice, and critical care nurse engagement in these practices. The findings highlight future training and practice development opportunities, including the need for experiential learning targeting the emotional support practice domain. Further research is needed to enhance knowledge of symptom management practices during the provision of end-of-life care to inform and improve practice in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We initially look at the changing energy environment and how that can have a dramatic change on the potential of alternative energies, in particular those of organic photovoltaicvs (OPV) cells. In looking at OPV's we also address the aspects of where we are with the current art and why we may not be getting the best from our materials. In doing so, we propose the idea of changing how we build organic photovoltaics by addressing the best method to contain light within the devices. Our initial effort is in addressing how these microscale optical concentrators work in the form of optical fibers in terms of absorption. We have derived a mathematical method which takes account of the input angle of light to achieve optimum absorption. However, in doing so we also address the complex issue how the changing refractive indices in a multilayer device can alter how we input the light. We have found that by knowing the materials refractive index our model takes into account the incident plane, meridonal plane, cross sectional are and path length to ensure optical angular input. Secondly, we also address the practicalities of making such vertical structures the greater issue of changing light intensity incident on a solar cell and how that aspects alters how we view the performance of organic solar cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical transmittance and conductivity for thin metallic films, such as Au, are two inversely related and extremely important parameters for its application in organic photovoltaics as the front electrode. We report our findings on how these parameters have been optimized to attain maximum possible efficiencies by fabricating organic solar cells with thin Au film anodes of differing optical transmittances and consequently due to scaling at the nanolevel, varying electrical conductivities. There was an extraordinary improvement in the overall solar cell efficiency (to the order of 49%) when the Au thin film transmittance was increased from 38% to 54%. Surface morphologies of these thin films also have an effect on the critical parameters including, Voc, Jsc and FF.